TY - JOUR ID - TI - Numerical Investigation of the Effect of Wire Screen Mesh Specification and Evaporator Length on Thermal Performance of Cylindrical Heat Pipe AU - Hassanain Ghani Hameed AU - Abudl-Muhsin A. Rageb PY - 2014 VL - 14 IS - 2 SP - 240 EP - 254 JO - Basrah Journal for Engineering Sciences مجلة البصرة للعلوم الهندسية SN - 18146120 23118385 AB - A numerical model has been developed to determine the effect of the wire screen mesh (wick) type on the heat transfer performance of copper–water wicked heat pipe. This model represented as steady-state incompressible flow. The governing equations in cylindrical coordinates have been solved in vapor region, wick structure and wall region, using finite difference with forward-backward upwind scheme. The results show that increasing the mesh number led to decreasing the maximum heat transfer limit and increasing the capillary pressure. While, for the same heat input the operating temperature of the heat pipe increase when the mesh number increase. Also, it was found that increasing the evaporation length, with constant condensation length, decrease the operating temperature and increase the maximum heat transfer limit. For verification of the current model, the results of liquid pressure drop for a heat pipe have been compared with the previous study for the same problem and a good agreement has been achieved.