TY - JOUR ID - TI - The Effect of Magnetic Field on Helium Plasma Characteristics of Discharge Tube تأثير المجال المغناطيسي على خواص بلازما غاز الهيليوم في إنبوبة التفريغ الكهربائي AU - Mahdya A. Yeser مهدية أحمد يسر AU - Adel H. Omran عادل حبيب عمران AU - Nibras F. Ali نبراس فاضل علي AU - Einas R. Wadaa إيناس رياض وداعه PY - 2016 VL - 8 IS - 1 SP - 34 EP - 40 JO - Journal of Kufa - physics مجلة الكوفة للفيزياء SN - 20775830 23126671 AB - The effect of discharge voltage of a discharge tube were investigated.The discharge voltage (700,800,900,1000,1100,1200) volt were applied under pressure of helium gas was (7Pa) and the inter electrode distance was (130mm). The measurements were achieved without and with parallel magnetic field of (25 mT). The electron temperature calculated from Id – Vd characteristics curves of double Langmuir probe. Results of electron temperature indicated that the behavior of electron temperature decreased with increasing the discharge voltage with and without the magnetic field.But their values at (B=0) was smaller than the corresponding values at (B=25 mT).

أنجز في هذا البحث دراسة تأثير فولتية التفريغ للفولتياتV (700,800,900,1000,1100,1200) تحت ضغط غاز الهيليوم (Pa 7) و المسافة بين القطبين الكاثود والأنود ( mm130). القياسات أنجزت بعدم وجود و بوجود مجال مغناطيسي مواز ذو الشدة ( mT 25). حسبت درجة حرارة الألكترون من منحني الخصائص لمجس لانكمور الثنائي. وقد وجد أن درجة حرارة الألكترون تقل بزيادة فولتية التفريغ في حالتي وجود و عدم وجود المجال المغناطيسي الموازي. لكن قيمها بعدم وجود المجال هي أصغر من قيمها بوجود المجال الموازي Id-Vd. ER -