@Article{, title={EFFECT OF CUTOFF FLOW ON THE ENERGY CONSUMPTION AT DESIRED POINT OF PNEUMATIC ACTUATOR تاثير قطع الجريان للمشغلات الهوائية على معدل استهلاك الطاقة في نقطة محددة مسبقا}, author={Dr.Hasasn Ali Jurmut}, journal={Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية}, volume={9}, number={3}, pages={302-315}, year={2016}, abstract={This paper presents a study the performance and to improve energy efficiency of the traditional pneumatic driver, three supply pressures used 4, 6 and 8 bar, by cutoff flow process occurs at stroke end of the actuator before execution position, in which pressure supply line cutoff and the exhaust line remains open in position specified previously. The piston stroke completes rest under the influence of air expansion , the inertia force of the piston exactly at execution position, that is saving in compressed air and energy, reduced in required air additional to reduce the cost. compared with the traditional control of motion of the asymmetric cylinder in which maximum energy saving obtained at 6 bar are 16.7%.

الخلاصة في هذا البحث تم دراسة تحسين اداء كفاءة المنظومة الهوائية وذلك من خلال قطع جريان هواء الضغط المجهز قبل نهاية شوط المشغل بمسافة تحدد بالاعتماد على ضغط التجهيز والحمل الكلي مع بقاء خط العادم مفتوحا ولضغوط تجهيز 6 , 8 و4 بار ولما لها من مردود في تقليل معدل صرف الطاقة وبالاستفادة من تمدد ضغط الهواء المحصور وقوة القصور الذاتي لوزن مكبس الاسطوانة في تكملة ماتبقى من الشوط ,كذلك توفير هواء مضغوط وطاقة بالاضافة الى تقليل الكلفه, مقارنة مع السيطرة التقليدية لحركة الاسطوانة غير المتماثلة للحصول على توفر طاقة قصوى 16.7٪ عند ضغط6 بار.} }