TY - JOUR ID - TI - Experimental investigation of the effect of hot finnedtube position on the heat transfer coefficient AU - Musa M. Wais AU - Murad S. Sedeeq AU - Ehsan F. Abbas PY - 2017 VL - 25 IS - 2 SP - 685 EP - 692 JO - Journal of University of Babylon مجلة جامعة بابل SN - 19920652 23128135 AB - In the present study, an experimental investigation is carried out to calculate heat transfer coefficient from the change in position of a finned tube in the cross-flow heat exchanger in two different conditions, which are a constant temperature at 90oC and constant heat flux at 45W/m2. A standard laboratory device (crossflow heat exchanger) was used in experiment process, that which manufactured by EDIBON company. The air flow over finned tubes inside heat exchanger was studied at Reynolds number ranging from 3600 to 11600. The comparative of experiments results between two cases shows that the Nu number in four positions at the constant temperature condition are higher than symmetrical positions in constant heat flux. The results indicated that the position3 gives higher values of Nu number in both cases

تشمل الدراسة الحالية تحليل نتائج اختبارات التي اجريت لحساب قيمة معامل انتقال الحرارة و ثاثيرها بتغير موقع انبوب مزعنف في مبادل حراري متعامد وفي حالتين من التسخين ( ثبوت درجة حرارة 90 مئوية و فيض حراري ثابت 45 واط/م2). حيث اجريت الدراسة في مدى لجريان الهواء تتراوح من 3600 الى 11600 رقم رينولد وذلك من خلال استخدام مبادل حراري مختبري نوع متعامد مجهز من قبل شركة EDIBON المتخصصة في صناعة الاجهزة المختبرية. من خلال مقارنة نتائج للحالتين، تبين بان رقم نسلت عند المواضع الاربعة في حالة ثبوت درجات الحرارة اعلى من مواضع مماثلة عندحالة ثبوت الفيض الحراري ومن مجمل النتائج الاختبارات تبين بان الموضع رقم 3 تعطي اعلى قيم لرقم نسلت للحالتين. ER -