@Article{, title={EXPERIMENTAL STUDY FOR TRANSIENT HEAT TRANSFER FROM A FLAT PLATE UNDER AIR IMPINGEMENT دراسة عملية لانتقال الحرارة الانتقالي من صفيحة مستوية تحت تبريد الهواء التصادمي}, author={Adnan A. Abdul Rasool and Dhamyaa Saad Khudhur and Sarah Ahmed Oudah}, journal={Journal of Engineering and Sustainable Development (JEASD) مجلة الهندسة والتنمية المستدامة}, volume={21}, number={2}, pages={62-79}, year={2017}, abstract={The present work represent an experimental study to verify the transient heat transfer characteristics of a target plate under air impingement from different orifice sizes (D=5, 10, 15 and 20mm), with orifice to plate distance ratio (H/D=2, 4, 6 and 8). Air jet velocities is varied in the range (Uj=18-40m/s) representing (Re=7100-11900). The heat transfer coefficient on the target plate are calculated on the basis of two dimensional infinite case. The local variation of Nusselt number in the transient period is measured. The values are compared to that at the steady state condition. Results show that the Nusselt values are maximum at state of impingement process and decays with time on proceeding of the cooling process and also with space reaching the plate edge.

يتمثل العمل الحالي دراسة تجريبية للتحقق من خصائص الانتقال الحراري الانتقالي لصفيحة الهدف في ظل اصطدام الهواء من احجام اقطار مختلفة (D=5,10,15,20mm), مع المسافة النسبية بين القطر و الصفيحة (H/D=2,4,6,8). تتنوع سرعات الهواء الخارجة من فوهة القطر ضمن فترة (Uj=18-40 م/ث) تمثل (Re=7100-11900). يتم احتساب معامل انتقال الحرارة على الصفيحة الهدف على أساس حالة لانهائية الأبعاد الثنائية. يتم قياس تباين عدد نسلت الموضعي في الفترة الانتقالية τ_o. تتم مقارنة القيم مع الحالة مستقرة. وأظهرت النتائج أن قيم نسلت هي الحد الأقصى في حالة عملية اصطدام و يضمحل مع مرور الوقت على إجراء عملية التبريد و أيضا مع المسافة إلى حافة الصفيحة.} }