TY - JOUR ID - TI - OPTIMIZATION THE EFFECT OF COLUMN CROSS SECTION SHAPE AND DIMENSIONS ON THECRITICAL BUCKLING LOAD تحسين تأثير شكل مقطع العمود وأبعاده على حمل الانبعاج الحرج AU - Sabah Khammass Hussein د.صباح خماس حسين PY - 2017 VL - 30 IS - 1 SP - E1 EP - E14 JO - Journal of Techniques مجلة التقني SN - 27088383 AB - The critical buckling load of column for different cross section shapes is analyzed. The constant cross sectional area of all shapes is assumed constant. The theoretical equation of buckling load is compared with the finite element model using ANSYS11 program. A good resultsare obtained as comparing with the theoretical. The results indicate that the critical buckling load depends on the shape and dimensions of column section. It is observed that the higher values of critical buckling load are found in the U- section while the Z- section gave lower values. Increasing the thickness of cross section resulted in decreasingthe critical buckling load. Approximately, it has been observed that the increasing the width of column section resulted in increasing the critical buckling load.

تم تحليل حمل الانبعاج الحرج للعمود ذواشكال مساحة مقطع مختلفة . مساحة كل المقاطع أفترضت ثابتة. المعادلة النظرية لحمل الانبعاج قُورنت مع نموذج العناصر المحددة بأستخدام برنامج ال (ANSYS11). حصلنا على نتائج جيدة مقارنة مع النظري. النتائج أشارت بأن حمل الانبعاج الحرج يعتمد على شكل وأبعاد العمود. لوحظ أن القيم العالية للحمل الانبعاج الحرج وجدت في مقطع (U) بينما مقطع ال (Z) أعطى أقل القيم. زيادة سمك المقطع أعطى نقصان في حمل الانبعاج الحرج. وبشكل تقريبي لاحظنا أن الزيادة في عرض مقطع العمود اعطى زيادة في حمل الانبعاج الحرج. ER -