TY - JOUR ID - TI - Thermal Performance of a Heat Pipe with Sintered Powder Metal Wick Using Ethanol and Water as Working Fluids الأداء الحراري لأنبوب حراري مبطن بفتيل من مسحوق معدني عندما يكون الايثانول أو الماء مائعا التشغيل. AU - Ahmed A.M.Saleh أحمد عبد محمد صالح AU - Obaid T.Fadhil عبيد طلك فاضل PY - 2010 VL - 3 IS - 2 SP - 62 EP - 71 JO - Anbar Journal of Engineering Sciences مجلة الأنبار للعلوم الهندسية SN - 19979428 27067440 AB - An experimental study is carried out to compare the thermal performance of a sintered powder metal wick heat pipe. Pure water and absolute ethanol are used as two different working fluids. The pipe is made of copper with 300 mm length, 14 mm diameter, and 1.0 mm wall thickness. The wick is made of copper powder. All the experiments are accomplished and the heat pipe is at the horizontal position (è=0o). The heat flux changed within the range (2.8 -13.13) kW/m2, while all other conditions remained constant.
The results show that the thermal performance of the heat pipe is better when water is the working fluid, where the operating temperature and the thermal resistance of the heat pipe are lower when the water is the working fluid.

لقد أجريت دراسة تجريبية على أنبوب حراري مبطن بفتيل مسامي لمقارنة الأداء الحراري للأنبوب عند استخدام كل من الماء النقي والايثانول المطلق كمائع تشغيل. الأنبوب من النحاس وهو بطول (300 mm) وقطر داخلي (14mm) وسمك جدار الأنبوب (1.0 mm), أما الفتيل فهو من مسحوق النحاس.أجريت جميع التجارب والأنبوب الحراري بوضع أفقي (θ=0o). تم تغيير الفيض الحراري ضمن مدى تراوح بين kW/m2(2.8 – 13.13) وتثبيت الظروف الأخرى كافة.أظهرت النتائج أن الأداء الحراري للأنبوب يكون أفضل عند استخدام الماء مائعا للتشغيل, حيث لوحظ أن درجة حرارة الاشتغال وكذلك المقاومة الحرارية للأنبوب تكونان أوطأ عندما يكون الماء مائعا للتشغيل ER -