TY - JOUR ID - TI - Study the Effect of Scattering and Disperse Radiation on Equivalent Dose Rate for Al & Pb Shields دراسة تاثير الاستطارة والتشتيت على معدل الجرعة المكافئة لدروع الالمنيوم والرصاص AU - Nabil Janan Bahnam نبيل جنان بهنام PY - 2011 VL - 8 IS - 2 SP - 261 EP - 268 JO - Baghdad Science Journal مجلة بغداد للعلوم SN - 20788665 24117986 AB - The effects of scattering and secondary radiation generated inside the material on dose equivalent rate where studied using Co60 and Cs137 sources of activity (199.8 , 177.6) MBq , respectively for different thicknesses of Al , Pb and Pb- glass . The results showed that the equivalent rate increases when the effect of scattering was included for Al and Pb shields with cobalt-60 source of energy 1.25 MeV ; and decreases for Pb shield with Cs-137 source of energy 0.662MeV .The results showed also that the atomic number of The material effects the dose equivalent rate . The Pb-glass shield was found to be more efficient in absorption than other shields.

تم دراسة تاثير الاستطارة و للاشعة الثانوية المتولدة داخل المادة على معدل مكافئ الجرعة الاشعاعية باستعمال مصدري و بفعالية) MBq 199.8, 177.6) على التوالي لاسماك مختلفة لدروع (Al , Pb, Pb- glass) اظهرت النتائج ارتفاع معدل الجرعة عند ادخال تاثير الاستطارة بأستخدام دروع Al , Pb عند طاقة 1.25MeV لمصدر الكوبلت -60 .ويقل هذا التاثير لدرع الرصاص عند طاقة 0.662 MeV لمصدر السيزيوم -137. وبينت النتائج ان معدل الجرعة يتاثر بالعدد الذري لمادة الدرع فكان درع الرصاص المزجج الافضل حيث ابدى امتصاصية اكبر من بقية الدروع . ER -