TY - JOUR ID - TI - Chlorine Removal with Activated Carbon Using Bubble Column ازالة الكلورین في عمود كاربون منشط AU - Naseer A. Al Habobi AU - Natheer Nori Ismail AU - Moayad Fadhel Hamad PY - 2012 VL - 30 IS - 9 SP - 1528 EP - 1537 JO - Engineering and Technology Journal مجلة الهندسة والتكنولوجيا SN - 16816900 24120758 AB - Bubble column slurry reactor was used for the measurements of gas adsorptionand ion-exchange in this work. Adsorption of chorine (dissolved in water) onactivated carbon was carried out in the same reactor. The effect of gas flowrates uG0.016 m s–1-0.027 m s–1 which covers the boundaries of the following four regimes:bubbly flow, first transition, second transition, and coalesced bubble and solidconcentrations were investigated. In addition of studying the pH which gives anindication for Hypochlorous Acid HOCl, the most active sanitizer form of FreeChlorine. These design guidelines provide a good starting point for system ofremoving chlorine from water at activated carbon concentration 20 gm/L, gasvelocity 0.023 m/s and contact period of time more 17 minutes.

استخدم العمود الفقاعي الثلاثي الاطوار لحساب امتزاز الغاز وكذلك تحول الايونات. وفيه يتمامتصاص الكلور المذاب بالماء بواسطة الكاربون المنشط المحمل داخل الانبوب. حسب كل منتأثير سرعة جريان الغاز (الهواء) والتي تغطي اطوار الجريان الفقاعي والانتقالي 1,2 وتكسر0.027 م/ثا وتأثير كمية الصلب لكل لتر ماء بالاضافة الى حساب التغيير في - الفقاعات 0.016. HOCl الى OCl– قيمة الاس الهيدروجيني والذي يعتبر مؤشر لتحول ايوناتمن خلال التجارب تقدم نقطة البداية لتصميم منظومة ازالة الكلور من المياه وذلك عند تركيزالكاربون المنشط 20 غم/لتر ، سرعة غاز 0,023 م/ثا وفترة زمنية اكثر من 17 دقيقة.الكلمات المفتاحية: كاربون المنشط، ازاله الكلور، العمود الفقاعي ذو الحبيبات الصلبة المعلقة. ER -