TY - JOUR ID - TI - Power Generation By Utilizing The Compound Gases With Spilled Oil At Using Power Chimney Techniques AU - Dr. Rafid M. Hannun PY - 2011 VL - 278 IS - 4th SP - 45 EP - 71 JO - Journal of Petroleum Research & Studies مجلة البحوث والدراسات النفطية SN - 22205381 27101096 AB - The power chimney tower is one of modern promised energy which may be developed by low losses, simple and has high facilities. In this paper, many parameters were studied exactly which influenced the prediction of system operation and fundamentally depend on the combustion of gases compound the spilled oil. Velocity distribution is the important parameter which gives the first prediction to put the position of erection of power turbine, made or not. The numerical analysis was presented by using GAMBIT and FLUENT 6.3 to predict that high velocity at the expansion of chimneynear the centre of burned gases cover collector. This position is very suitable for promoting andbuilding the power turbine since the velocity was more than (33 m/s) when the compounded gases is combusted (that there components are the methane gas with other friendly gases and waste. It is easy to erect steam or gaseous boiler in contact with furnace for utilize the heat generated in electrical power generation. So, the other factors, temperature and pressure were studied to coincide with previous papers in this field.

ER -