@Article{, title={Determination of Atomic Number Exponent for Elemental Absorber at Am– 241 Energy in X–Ray Attenuation Experiments}, author={Laith Ahmed Najim and Sabeeh Karyakos Shamoon and Shiama Talal Atalah}, journal={Al-Nahrain Journal of Science مجلة النهرين للعلوم}, volume={15}, number={3}, pages={95-100}, year={2012}, abstract={In X-ray absorption experiment, the dependence of the photoelectric absorption cross-section varied with atomic number Z. In this paper, the dependence on Z of the cross – section or coefficient of photoelectric absorption is first evaluated from published data for (20) elements ranging from Al–Sn, and then the cross–section for Fe is obtained experimentally by measuring the X-ray intensity with and without the Fe absorber and compared with the theoretical value, the variation of the photoelectric absorption coefficient (µ/ρm) showed less dependence on Z for the two tested of Z regions. This is because of the inclusion of mass density (ρm) of the absorber in the coefficient. The values of m obtained in the present work increases linearly with energy for both ranges of elements

يتغير اعتماد المقطع العرضي للامتصاص الكهروضوئي في تجارب امتصاص الأشعة على العدد الذري Z. تم في هذا البحث تضمن اعتماد المقطع العرضي أو معامل الامتصاص الكهروضوئي على العدد الذري من البيانات المنشورة أولا لعشرين عنصر تتراوح A l – Sn حيث تم الحصول على المقطع العرضي للحديد تجريبيا بقياس شدة الأشعة السينية بدون وبوجود الحديد ومقارنة مع القيم النظرية، مقدار التغير في معامل الامتصاص الكهروضوئي(µ/ρm) يظهر أقل اعتمادا علىZ بالنسبة لمنطقتيZ التي تم اختبارهما. هذا بسبب الأخذ بنظر الاعتبار الكثافة الكتلية(ρm) للمادة الماصة في المعامل وتزداد قيمm التي حصلنا عليها خطيا مع الطاقة لكلا مديات العناصر المستخدمة.} }