TY - JOUR ID - TI - Treatment of Oily Wastewater by Induced Air Flotation معالجه المياه الملوثه بالنفط بطريقه التطويف AU - Thamer .J.Mohammed AU - Shahad .S. Mohammed AU - Zaidoon khalaf PY - 2013 VL - 31 IS - 18 Part (A) Engineering SP - 88 EP - 99 JO - Engineering and Technology Journal مجلة الهندسة والتكنولوجيا SN - 16816900 24120758 AB - In this study induced air flotation (IAF) through Perspex glass column (ID 10cm and 150 cm heights) has been studied experimentally to treat the oily wastewater of Iraqi North Oil Company. The column operated in a semi-batch mode (batch wastewater, continuous air injection). Different samples of oily wastewater (30,100,800ppm) were used. Air introduced at different superficial gas velocity through porous (pore size 120µm) distributor which located at the bottom of column. Different speed of the stirrer (50 to 250) rpm was used to indicate it effect on the removal efficiency of oil from water.The study showed that the removal efficiency of oil was increased with increasing initial oil concentration, it reached up to 76 %. While it became 89% when using stirrer.The experimental results were translated to a computer program to predicate empirical correlation.

في دراسه عمليه التطويف المستحث من خلال عمود التطويف (القطر الداخلي 10 سم وبارتفاع 150 سم) تمت عمليه معالجه الماء الملوث بالنفط لشركه نفط الشمال العراقيه. العمود يعمل بنظام شبه وجبه (وجبه من الماء الملوث وضخ للهواء مستمر). تم اخذ عينات مختلفه من الماء الملوث بالنفط بتراكيز(30,100,800) جزء بالمليون. الهواء الداخل بسرع مختلفه من خلال الثقوب (حجم الثقب 120 مايكرومتر) حيث ان الموزع يقع في نهايه العمود. سرع مختلفه من الخلاط المستعمل تتراوح من (50الى 150)دوره بالدقيقه لمعرفه مدى تاثير هذه السرع على كفاءه ازاله النفط من الماء. الدراسه بينت ان كفاءه الفصل للنفط تزداد بزياده التركيز الابنتدائي للنفط , وقفزن من 76% الى 89% باستخدام الخلاط. النتائج العمليه ترجمت بواسطه انظمه الحاسوب لاسناد الارتباط التجريبي. ER -