@Article{, title={Flow injection spectrophotometric determination of Tetracycline hydrochloride in pharmaceutical samples التقدير الطيفي الحقن الجرياني للتتراسايكلين هيدروكلورايد في النماذج الصيدلانية}, author={Mouyed Qassim Al-Abachi مؤيد قاسم العباجي and Hind Hadi هند هادي عبد الله}, journal={Iraqi National Journal Of Chemistry المجلة العراقية الوطنية لعلوم الكيمياء}, volume={}, number={55}, pages={243-251}, year={2014}, abstract={AbstractTetracycline hydrochloride (TCH) was determined spectrophoto-metrically in the pure form and in the pharmaceutical formulations using flow injection analysis (FIA). The automated method is based on the reaction between TCH, sodium nitroprusside and hydroxylamine hydrochloride in alkaline medium. The product absorbed maximally at 529 nm. The calibration graph of TCH is linear from 25-1000 µg mL-1 with detection limit (S/N=3) of 7.589 µg mL-1 and sample through put of 69 h-1. The various chemical and physical variables were optimized and the proposed procedure was applied successfully for estimation of drug in different commercial forms.

الخلاصةتم تقدير التتراسايكلين هيدروكلورايد بشكله النقي وفي المستحضرات الصيدلانية طيفيا باستخدام تقنية التحليل بالحقن الجرياني.تعتمد الطريقة المؤتمتة على التفاعل بين التتراسايكلين وهيدروكسيل امين هيدروكلورايد في الوسط القاعدي.الناتج اعطى اعلى امتصاص عند 529 نانومترا وبلغ مدى الخطية من 25-1000 مايكروغرام من التتراسايكلين هيدروكلورايد لكل مللتر من المحلول وبحد كشف 7.589 مايكروغرام مل-1 وبمعدل نمذجة 69 نموذج بالساعة.تمت دراسة جميع التغيرات الفيزيائية والكيميائية وتم تطبيق الطريقة وبنجاح لتقدير الدواء بمختلف اشكاله التجارية.} }