Table of content

Al-Qadisiyah Journal for Engineering Sciences

مجلة القادسية للعلوم الهندسية

ISSN: 19984456
Publisher: Al-Qadisiyah University
Faculty: Engineering
Language: Arabic and English

This journal is Open Access

About

Al-Qadisiyah Journal for Engineering Sciences (QJES), ISSN: 1998-4456, was established in 2008. The Journal, in its current form, is intended to contribute to the state of the art in all fields of engineering research.
The Journal is a peer-reviewed journal and is published by the Faculty of Engineering, University of Al-Qadisiyah. The journal is now published Quarterly(March, June, September and December).

Loading...
Contact info

College of Engineering - Al-Qadisiyah university - Al-Diwaniya province - Rep. of Iraq box ( 1759 ) - fax (00964 (0) 36 652663) - Tel: +964(780)1432941
E-mail: engjou@qu.edu.iq

Table of content: 2010 volume:3 issue:3

Article
STUDY THE PERFORMANCE OF GLASS INSULATORS FOR (132KV, 33KV) LINES UNDER THE INFLUENCE OF ARTIFICIAL CONTAMINATION
دراسة اداء العوازل الزجاجية لخطوط (132KV,33KV) تحت تأثير التلوث المصطنع

Loading...
Loading...
Abstract

The phenomenon of broken glass insulators which imported recently and currently being used to work in Iraqi transmission and distribution (132KV, 33KV) lines have greatly increased in recent years, which raised the need to examine the performance of these insulators under the influence of artificial contamination by simulating the climatic prevailing in the country. In this paper we have study the performance of two types of glass insulator which recently imported, the first works in (132KV) transmission systems and the second works in (33KV) distribution system, we have calculated the a mount of sodium chloride equivalent to several levels of salt deposit density in the chemical laboratory of the Nasiriyah thermal power plant station, then we have contamination surfaces of elected insulators to examine with two a mount of sandy loam (25g, 50g) with addition of calculated a mount of sodium chloride equivalent to several levels of equivalent salt deposit density and for several levels of pollution ( light, moderate and high). We have studied the performance of glass insulator elected for examination under the influence of artificial pollution in the high voltage laboratory of shatra technical institute, the calculated result show a serious decline in the value of flashover voltage at moderate and high artificial contamination and relatively good performance at light artificial contamination and also show non-conformity the value of flashover voltage for clean ( new ) insulator with the specification of the manufacturer of insulator. The study recommended a number of recommendations which are necessary to work with to a void the risk of recurrence of the phenomenon of broken glass insulator. ازدادت في الاونة الاخيرة وبشكل مضطرد ظاهرة تهشم العوازل الزجاجية المستوردة مؤخرا" للعمل في انظمة النقل والتوزيع العراقية (132KV,33KV)، مما رفع الحاجة الى دراسة اداء هذه العوازل تحت تأثير التلوث المصطنع (Artificial Contamination) من خلال محاكاة الظروف المناخية السائدة.
تم في هذا البحث دراسة اداء نوعين من العوازل الزجاجية المستوردة مؤخرا"، الاول مستخدم في انظمة النقل (132KV) والثاني مستخدم في انظمة التوزيع (33KV)، حيث تم احتساب كمية كلوريد الصوديوم المكافئة لعدة مستويات من كثافة مكافئ الترسب الملحي (ESDD) في المختبر الكيماوي التابع لمحطة كهرباء الناصرية الحرارية، ليتم بعدها تلويث اسطح العوازل(132KV,33KV) المنتخبة للفحص بالتلوث المصطنع بكميتين من الرمل الغريني (Sandy Loam) ( 25g, 50g) مع اضافة كمية كلوريد الصوديوم المحتسبة مسبقا والمقابلة لمستوى مكافئ الترسب الملحي ولعدة مستويات من التلويث ( الخفيف، المتوسط، العالي). لقد تم دراسة اداء العوازل الزجاجية المنتخبة للفحص تحت تأثير التلوث المصطنع في مختبر الضغط العالي التابع للمعهد التقني الشطرة، حيث اظهرت النتائج انحدارا" خطيرا في قيمة فولتية الومضة العابرة (Flashover Voltage) عند التلوث المصطنع المعتدل والعالي واداء جيد نسبيا عند التلوث المصطنع الخفيف، كما اظهرت ايضا عدم مطابقة قيمة فولتية الومضة العابرة للعوازل الجديدة(النظيفة) مع مواصفات الشركة المصنعة للعوازل، اوصى البحث بعدة توصيات ضرورية للعمل بها بهدف تفادي مخاطر تكرار ظاهرة تهشم العوازل الزجاجية.


Article
WATER QUALITY MONITORING OF AL-HAWIZEH MARSH
مراقبة نوعية مياه هور الحويزة

Authors: Eman Abd Mohammed
Pages: 222-233
Loading...
Loading...
Abstract

The Mesopotamian marshlands faced a massive destruction from the year 1990 till 2003. This destruction leads to displace the marsh dwellers and decrease the numbers of flora and fauna in the region. After the war in 2003 in Iraq the rehabitation and restoration of the devastated marshland ecosystem started. In this study a survey was made on the physical and chemical characteristics of Al-Hawizeh marsh for an interval and creates comparison among these characteristics during the four season’s then format a relationships between water salinity and electrical conductivity and another relationship between turbidity and total suspended solid. It was found that the water quality of Al- Hawizeh marsh for most of the properties was good in summer time because of the flood water from Tigris and the other feeders of the marsh. Some properties of Al-Hawizeh marsh was coincide with the maximum allowable values of the Iraqi drinking standards (1986). The equation between the salinity and electric conductivity was exponential equation while between the turbidity and the total suspended solid was power equationان الاهوار في بلاد مابين النهرين قد تعرضت الى تدمير كبير من عام 1990 الى 2003. هذا التدمير ادى الى هجرة ساكني الاهوار والى نقصان نباتات وحيوانات المنطقة. بعد حرب 2003 بدأت عملية اعادة تأهيل وأحياء الاهوار المدمرة . تم في هذه الدراسة اجراء مسح على الخواص الفيزياوية والكيمياوية لهور الحويزة خلال فترة معينة ومقارنة هذه الخواص خلال فصول السنة الاربعة ومن ثم تكوين علاقة رياضيه تربط بين ملوحة الماء والتوصيل الكهربائي وعلاقة اخرى بين العكورة وتركيز المواد الصلبة الكلية. وقد تم التوصل في هذه الدراسة الى التالي: -- نوعية مياه هور الحويزة ,بالنسبة لأغلب الخواص, كانت جيدة خلال فصل الصيف بسبب كمية المياه الكبيرة القادمة الى الهور من نهر دجلة وبقية مغذيات الهور.بعض خواص مياه الهور كانت متطابقة مع القيم العليا المسموحة لمياه الشرب حسب المواصفة العراقية لعام 1986. توجدعلاقة تربط الملوحة بالتوصيل الكهربائي وهي علاقة اسية اسية exponential equation وعلاقة بين العكورة وتركيز المواد الصلبة وهي علاقة اسية power equation.


Article
STRENGTH OF REACTIVE SILICA SAND POWDER CONCRETEMADE OF LOCAL POWDERS
مقاومة خرسانات المساحيق الفعالة المصنعة من مساحيق محلية

Loading...
Loading...
Abstract

The main purpose of this research is to study the strength of the RPC incorporating local powders (reactive silica sand powder) and compare it with RPC incorporating condensed silica fume. Original RPC- in form of superplasticized cement mixture with powder (reactive silica sand or silica fume ), steel fiber ,and fine sand (<600 mµ)- was studied in comparison with modified reactive powder concrete (MRPC) where a natural aggregate (max size 8mm)was used to replace the fine sand of the cementitious binder. In the present research work compressive strength, (incorporating local reactive silica sand powder) of reactive powder concrete and modified reactive powder concrete were studied. High 28-day compressive strengths (101-115 MPa) were gained when using local powders.الغرض الرئيسي من هذا البحث هو لدراسة مقاومة الخرسانة ذات المساحيق الفعالة المنتجة من مساحيق محلية (مساحيق الرمال السلكية الفعالة) و مقارنتها مع الخرسانة ذات المساحيق الفعالة المنتجة من أبخرة السليكا المكثفة. الخرسانة ذات المساحيق الفعالة الأصلية – والتي تكون بشكل خليط من السمنت والملدن المتفوق مع مساحيق الرمل السليكي أو الأبخرة السلكية المكثفة , ألياف الحديد, الرمل الناعم (بمقاس اقل من 600 مايكروميتر) قد تم دراستها ومقارنتها مع الخرسانة ذات المساحيق الفعالة المطورة والتي بها يتم استبدال جزء من الرمل الناعم في الخلطة الإسمنتية الرابطة بالركام الطبيعي ( بمقاس 8 ملم كحد أقصى). في هذا البحث فان مقاومة الانضغاط قد تمت دراستها والفحوصات بينت انه الخرسانة ذات المساحيق الفعالة و الخرسانة ذات المساحيق الفعالة المطورة و المصنعة من المسحوق الرمل الزجاجي المحلي أظهرت قيما عالية في مقاومة الانضغاط (101-115 ميكاباسكال).

Keywords

cement --- mixture --- concrete --- powder


Article
USE OF COMBINED NONDESTRUCTIVE TEST METHODS TO PREDICT CONCRETE COMPRESSIVE STRENGTH CAST WITH AGGREGATE OBTAINED FROM SOUTHERN PARTS OF IRAQ
استخدام طرق الفحص الاإتلافي المشترك لتقييم مقاومة الانضغاط لخرسانة مصنعة من ركام من المنطقة الجنوبية للعراق

Loading...
Loading...
Abstract

Concrete compressive strength is one of the most important concrete requirements that can be used to decide if the concrete is structurally acceptable or not. In several cases there is a need to estimate the concrete compressive strength on the site during construction or later on during the life of concrete. There are several methods used for this purpose, among the mostly used methods are the Ultra sonic pulse velocity and the Schmidt hammer rebound number. In this work six different fine aggregate and two different coarse aggregate were obtained from different parts of southern Iraq. Using these different aggregate combinations, 120 different concrete mixes with mix proportions of 1:2:4 or 1:1.5:3 and W/C ratios ranging between 0.40 to 0.60 were cast into 152 mm cubes. The compressive strength, ultrasonic pulse velocity, Schmidt hammer’s rebound number and concrete density were measured. These results were introduced into nonlinear multiple variable regressions to obtain correlation relationships to predict the concrete compressive strength. Two groups of regressions were formulated, the first used only the Ultrasonic pulse velocity and rebound number in the regressions, and separate regressions were prepared for each single source of aggregate. The results of the predicted strength was in good agreement with the experimentally measured values, the value of the standard errors of these regressions were less than 10% of the lowest concrete strength investigated (20MPa). In the second group of regressions, the data from all concrete mixes with different aggregate sources were combined together to obtain the correlation regressions. These regressions were formulated because in many cases in practice the source of aggregate may not be known exactly. Two subgroups were developed, with different independent variables combinations. The standard error of this group was higher than for the first group, its best value was 16% of the minimum value of concrete strength investigated. This clearly proves the importance of the aggregate source on the predicted concrete compressive strength valuesتعتبر مقاومة انضغاط الخرسانة أحد أهم الخواص اللازمة لتحديد مدى قبولية الخرسانة من الناحية الإنشائية و الديمومة. في عدة حالات تظهر حاجة لتقييم مقاومة انضغاط الخرسانة في الموقع سواءً أثناء التنفيذ أو خلال عمر المنشأ بعد الانجاز. تستخدم عدة طرق لاأتلافية لتقييم مقاومة انضغاط الخرسانة و من أكثر هذه الطرق شيوعاً هي سرعة الأمواج فوق الصوتية ورقم ارتداد مطرقة شميت. في هذا البحث تم استخدام ستة أنواع مختلفة من الركام الناعم ونوعين من الركام الخشن من مصادر طبيعية مختلفة من المنطقة الجنوبية من العراق. استخدمت هذه الأنواع المختلفة من الركام في أعداد 120 خلطة خرسانية مختلفة بنسب خلط وزنية (1:2:4) أو (1:1.5:3) وبنسب ماء/سمنت تتراوح من 0.4 إلى 0.6 . استخدمت مكعبات قياسية بأبعاد 152 مم كنماذج للفحص . تم قياس سرعة الأمواج فوق الصوتية ورقم ارتداد مطرقة شميت وكثافة الخرسانة على هذه النماذج ثم بعد ذلك تم قياس مقاومة أنضغاطها أتلافيا لحين الفشل. استخدامت نتائج هذه الفحوصات في إجراء تحليل لاخطي متعدد المتغيرات لإيجاد علاقات ارتباط لتخمين مقاومة انضغاط الخرسانة بأستخدام الفحوصات اللاأتلافية. تم صياغة مجموعتين من عمليات التحليل, في المجموعة الأولى استخدم سرعة الأمواج فوق الصوتية ورقم ارتداد مطرقة شميت فقط لتحديد مقاومة أنضغاط الخرسانة. أجريت عمليات التحليل لكل نوع من أنواع الركام وكانت القيم المستنبطة لمقاومة انضغاط الخرسانة مقاربة للنتائج العملية وبنسبة خطأ قياسي لاتتجاوز 10% من أقل قيمة مسجلة لمقاومة انضغاط الخرسانة. أما في المجموعة الثانية من عمليات التحليل فقد تم أعتماد نتائج كافة الفحوصات و لجميع الخلطات بغض النظر عن نوع الركام والسبب في ذلك أن مصدر الركام في كثير من الاحيان قد يكون مجهولاً عند تقييم خرسانة المنشأ. أعطت نتائج المجموعة الثانية نسبة خطأ أعلى من المجموعة الأولى حيث كانت أفضل قيمها تساوي 16% من أقل قيمة مسجلة لمقاومة الانضغاط. هذه النتيجة تثبيت أن تحديد نوع و مصدر الركام المستخدم في الخلطة الخرسانية عامل مهم في عملية تحمين مقاومة انضغاط الخرسانة.


Article
INFLUENCE OF DEGREE OF CRUSHING OF COARSE AGGREGATE ON PROPERTIES OF ASPHALT PAVING MIXTURES USED FOR SURFACE COURSES
تأثير نسبة التكسير للحصى الخشن على خواص الخلطات الإسفلتية المستخدمة للطبقات السطحية

Loading...
Loading...
Abstract

Using unsuitable material will often result in premature failure of pavement surface and reduction in the ability of pavement to carry the design traffic load.
The use of locally natural materials of gypseous soils is necessary to minimize the construction cost. The chemicals and physical tests carried out on this gypsies soil brought from western region of Iraq indicates clayey sand particles with 63% gypsum content. The chemical and physical effects on behavior of gypseous soil is studied by leaching using modifying the standard odometer apparatus to be able for testing a large cell of CBR mold under loading values ( 44.5;178;311 )N with different hydraulic gradient values (2;6;10 ) for sixty days. For this purpose, fifty four CBR samples are prepared at a 95% relative to modified AASHTO compaction. The geotechnical properties of wetting gypseous soils due to the large damages that affect the structures founded and constructed on it. It is observed that the total leaching strain increases, as the surcharge load and hydraulic gradient increase. The results show that the value of CBR increasing with increasing compactive effort (dry density) after leaching gypseous sub grade soil. Decreasing voids particles by compactive effort, cause increase cementing materials which bond the soil particles together and increasing the stiffness. This can has an economic effect in pavement design as this increase in CBR% can transfer unsuitable material into suitable sub-grade gypsum soil.

توجد خواص كثيرة للحصى الخشن المستعمل في الخلطات الإسفلتية الممزوجة بدرجات الحرارة العالية والمفروشة بدرجات حرارة عالية مثل نوعية سطح الحبيبات, نسبة التكسير, قيمة صقل الحجر, التقشر, ونسبة التآكل وكل هذه الخواص تؤثر على سلوك الأداء لخلطات التبليط الإسفلتية. في هذه الدراسة تم دراسة تأثير نسبة التكسير للحصى المستخدم للخلطات الإسفلتية المحضرة للطبقات السطحية حسب المواصفات القياسية للطرق والجسور العراقية. تم اختيار أربع نسب مختلفة لدرجة تكسير الحصى ( 0%, 40%, 70% و 100%) لتحديد تأثير نسبة التكسير على الخواص الفيزيائية للخلطات الإسفلتية (الوزن النوعي للخلطة, نسبة الفجوات الهوائية, نسبة الفراغات بالركام, ثبات مارشال, جريان مارشال, ومقاومة الشد الغير مباشر ونسبة المقاومة المسترجعة). وبحسب هذه الدراسة وجد بان الخلطات الإسفلتية التي تحتوي على ركام خشن بنسبة تكسير تساوي40% تستوفي متطلبات المواصفات القياسية العراقية للطرق والجسور (SCRB) للطبقة السطحية.


Article
CHEMICAL AND PHYSICAL EFFECTS ON ENGINEERING PROPERTIES OF GYPSEOUS SUB-GRADE SOIL
التأثير الكيمياوي و الفيزياوي على الخصائص الهندسية لتربة أساس الطريق

Loading...
Loading...
Abstract

Using unsuitable material will often result in premature failure of pavement surface and reduction in the ability of pavement to carry the design traffic load.
The use of locally natural materials of gypseous soils is necessary to minimize the construction cost. The chemicals and physical tests carried out on this gypsies soil brought from western region of Iraq indicates clayey sand particles with 63% gypsum content. The chemical and physical effects on behavior of gypseous soil is studied by leaching using modifying the standard odometer apparatus to be able for testing a large cell of CBR mold under loading values ( 44.5;178;311 )N with different hydraulic gradient values (2;6;10 ) for sixty days. For this purpose, fifty four CBR samples are prepared at a 95% relative to modified AASHTO compaction. The geotechnical properties of wetting gypseous soils due to the large damages that affect the structures founded and constructed on it. It is observed that the total leaching strain increases, as the surcharge load and hydraulic gradient increase. The results show that the value of CBR increasing with increasing compactive effort (dry density) after leaching gypseous sub grade soil. Decreasing voids particles by compactive effort, cause increase cementing materials which bond the soil particles together and increasing the stiffness. This can has an economic effect in pavement design as this increase in CBR% can transfer unsuitable material into suitable sub-grade gypsum soil.
استخدام مواد غير ملائمة ضمن طبقات الطريق في التصميم تؤدي إلى عدم تحمل الأثقال المسلطة عليه و بالتالي حصول فشل في الطريق. استخدام التربة الطبيعية ضمن موقع التنفيذ ( التربة الجبسية) يقلل من كلفة المشروع. لذا تم إجراء الفحوصات الفيزيائية و الكيميائية لتربة موقع المشروع حسب نظام التصنيف الموحد فكانت من نوع تربة رملية طينية و تحتوي على جبس بنسبة 63% في المنطقة الغربية من العراق. تناولت هذه الدراسة تأثير الخواص الفيزيائية و الكيميائية من خلال غسل التربة الجبسية باستخدام قالب فحص نسبة التحمل الكاليفورني تم تحويره لتسليط الأحمال التصميمية المناظرة لإنشاء طريق وهي ( 44.5: 178 :311.5 ) نيوتن و بتسليط انحدار مائي قدره (2و6 و10 ) . و لهذا الغرض تم تحضير 54 نموذج و كانت نسبة الرص 95% و الفترة الزمنية لغسل التربة الجبسية بحسب الانحدار المائي المذكور هو لغاية 60 يوم. أظهرت التجارب ضعف التربة الجبسية حين تتعرض للماء و حصول الانهيار فيها خصوصا بزيادة الانحدار الهيدروليكي و الأحمال المسلطة . أجريت مقارنة لنسبة التحمل الكاليفورني للتربة الجبسية بعد الغسل مع مقدار كثافتها الجافة بنسبة رص 95% أظهرت النتائج زيادة نسبة التحمل الكاليفورني مع زيادة نسب الرص و الكثافة الجافة للتربة الجبسية بعد الغسل. و بذلك بالإمكان استخدام التربة الطبيعية في الموقع كأساس لطبقات الطريق بدلا من استبدالها.


Article
IMPROVEMENT OF THE MECHANICAL PROPERTIES OF GYPSEOUS SOIL BY ADDITIVES
تحسين الخواص الميكانيكية للتربة الجبسيه بواسطة إضافات

Authors: Huda N. T. AL-Numani
Pages: 287-296
Loading...
Loading...
Abstract

The presence of gypsum in soil as bond agent alters its behavior, in other words, there is a large influence of gypsum on the physical and mechanical properties of soil. This influence depends mainly on the amount and type of gypsum presented in the soil. The soils used in this study were brought from one locations at Al-Tar region west of Al-Najaf city. These soils had gypsum content of 35%. The classification tests indicate that the soil is poorly graded. In this paper an experimental study is carried out on the effect of three different additives to the gypseous soil in order to improve the compaction properties of the gypsum soil. The additives used in this study were cement, ceramic and mix of cement and ceramic. The percentages of ceramic was varied between 4-12% in the first series whereas percentage of cement was between 4-8% by weight in the second series. In the third series the percentage of cement was kept constant 4% by weight while the percentage of ceramic varied from 4 to 12% by weight. Control groub without any additive was also tested to determine the effect of additives. The results show that the best improvement in compaction characteristics test is achieved when the sample is treated with adding mix of cement and ceramic, the maximum dry density only increase with the increases in mixing content, while the opposite is true for the optimum water content. The results also show that the maximum dry density of treated gypsum soil with ceramic material increases with the increase in ceramic content up to 8% after which the density decreases. وجود الجبس في التربة كعامل ربط يغير سلوكها, بتعبير أخر, هناك تأثير كبير للجبس على الخواص الفيزيائية والميكانيكية للتربة. يعتمد هذا التأثير بشكل رئيسي على كمية ونوع الجبس الموجود في التربة. لتربة المستخدمة في هذه الدراسة أخذت من موقع واحد من منطقة الطار الواقعة غرب مدينة النجف .كانت التربة ذات محتوى جبسي (35%). أشار اختبار التصنيف بأن التربة رمليه ضعيفة التدرج. في هذا البحث أجريت دراسة تجريبية على تأثير ثلاث إضافات مختلفة إلى التربة الجبسيه لكي تحسن خواص الرص للتربة الجبسيه . الإضافات المستعملة في هذه الدراسة هي الخزف , الأسمنت وخليط الأسمنت والخزف. النسب المئوية لمادة الخزف كانت تتفاوت بين (4-12%) في السلسلة الأولى بينما نسبة الأسمنت كانت بين (4-8%) من وزن التربة في السلسلة الثانية. في السلسلة الثالثة كانت نسبة الأسمنت ثابتة (4%) بينما تتراوح نسبة السيراميك بين (4-12%) من وزن التربة. كذلك فحصت التربة بدون أي إضافات لإيجاد تأثير هذه الإضافات. بينت النتائج بأن أفضل تحسين في خصائص الرص ينجز عندما تعالج العينة بإضافة خليط الأسمنت والخزف, حيث وجد أن الكثافة الجافة العظمى تزداد بزيادة محتوى الخليط, بينما العكس صحيح لمحتوى الماء الأمثل. بينت النتائج أن الكثافة الجافة العظمى للتربة الجبسيه المعالجة بمادة الخزف تزداد بزيادة محتوى الخزف إلى حد 8% بعدها تتناقص الكثافة.

Keywords

Soil --- Gypsum --- Ceramic --- Cement --- Compaction


Article
THE EFFECT OF PROXIMITY OF EARTHING CABLE AND POWER CABLES ON THE OPERATION OF EARTH FAULT PROTECTION UNIT AND CATHODIC PROTECTION
تأثير تقارب الموصل الارضي وموصلات القدرة على عمل وحدة الحماية ضد الخطأ الارضي والحماية الكاثودية

Authors: داود مشير جاسم
Pages: 297-310
Loading...
Loading...
Abstract

This work discusses the effect of proximity between the grounding cable and power cables of high hp 3-ph induction motor, on the operation of the unit of protection against earth fault current and on the system of cathodic protection of the pipes in deep wells, due to high circulating current of grounded cable, induced by the magnetic flux of a 3-ph current of induction motor because of the proximity effect. The work contains practical beneficial experiments, in the work site, for measuring circulating currents, theoretical analysis, useful Conclusions and a very useful recommendation to the engineers deal with this field. It is shown that the reason of circulating current in the earthing cable and the cathodic protection cable is the neighboring of earthing cable to the power cables ان هذا العمل يتطرق الى تاثير التقارب بين الموصل الارضى وموصلات القدرة في المحركات الحثية الثلاثية الاطوار ذات القدرة الحصانية العالية على عمل منظومة الحماية ضد التوصيل الارضي وعلى عمل منظومة الحماية الكاثودية لانابيب الابار العميقة نتيجة التيار الدوار المتولد فى موصل التأريض بسبب الفيض المغناطيسى المتولد من التيار المار فى موصلات التغذية المسايرة للموصل الارضي. يتضمن البحث تجارب عملية مجدية في حقل العمل لقياس التيارات الدوارة وتحليلات نظرية واستنتاجات وتوصيات مفيدة جدا للمهندسين العاملين في هذا المجال. واثبت بأن سبب التيار الدوار في موصل التأريض وفي موصل الحماية الكاثودية هو مجاورة موصل التأريض الى موصلات القدرة.


Article
SPEED CONTROL OF D.C SERIES MOTOR BY USING POWER MOSFET CHOPPER
السيطرة على سرعة محرك تيار مستمر باستخدام المقطعات

Loading...
Loading...
Abstract

The aim of this paper is to construct a system which can control the speed of d.c series motor by using power MOSFET chopper .The system contains close loop control which has a performance and characteristics in the operation.The close loop control system contains digital pulse width modulation circuit, driving circuit, over speed, and over current protection circuit. The power MOSFET devices are now available in production quantities and are already being utilized from switched power applications including motor control.HEXFET power MOSFET type IRFK4H350 is selected for this application due to its relative high current -handling ability up to 50A and a maximum drain -to- source voltage of 400v. All the theoretical transient responses of speed and current reveal fairly close agreement with practical response, the maximum deviation between them is (5%) . الهدف من هذا البحث هو السيطرة على سرعة محرك تيار مستمر توالي باستخدام مقطع ترانزستور تأثير المجال المعدني . النظام يعتمد السيطرة المغلقة والذي يحوي شكل وخواص العمل ، نظام السيطرة المغلقة يحوي دائرة التحميل العرضي للنبضة ودائرة السوق وحماية من السرعة الفائقة والتيار العالي ودائرة قياس التيار وجهاز قياس السرعة . ترانسستور تأثير المجال المعدني يستعمل في المحركات كمفاتيح سيطرة وفي بحثنا هذا استخدام ترانزستور تأثير المجال نوع (HEXFET power MOSFET type IRFK4H350) وذلك للقابلية العالية لتحمل تيار عالي50A)) وفولتية بين المصدر والساحب (400V).

Keywords

: mosfet --- chopper --- motor --- drain --- source --- thyristor --- transistor


Article
EFFECT OF CYLINDER SHAPE ON HEAT TRANSFER AND FLUID FLOW
تأثير شكل الاسطوانة على انتقال الحرارة وجريان المائع

Loading...
Loading...
Abstract

Two dimensional flow over single cylinder with different shapes in the free stream are numerically investigated. Consideration is given to the effect of cylinder seven shapes with the same area, and Reynolds number (Re) on heat transfer and flow phenomena. The study has been carried out for Reynolds number between (200-2000). The study discloses that the heat transfer and pressure drop are effected by cylinder shape. The relationship between Nuselt number (Nu) and angle from stagnation point (θ) also pressure coefficient (Cp) and angle from stagnation point (θ) are determined, the new shapes are compared with circular cylinder and the results show that maximum heat transfer be with the shape ( 7 ). جريان ثنائي البعد حول اسطوانة مفردة بأشكال مختلفة في جريان حر تم فحصه عدديا. تم الاخذ بنظر الاعتبار تاثير سبعة اشكال بنفس مساحة المقطع وعدد رينولز (Re) على انتقال الحرارة وشكل الجريان. تمت الدراسة ضمن مدى لرقم رينولز (200-2000). بينت الدراسة ان انتقال الحرارة والهبوط بالضغط يتاثر بشكل الاسطوانة. تم تحديد العلاقة بين رقم نسلت (Nu) مع الزاوية حول السطوانة المقاسة من نقطة الركود (θ) كذلك العلاقة بين معامل الضغط (Cp) مع الزاوية حول السطوانة المقاسة من نقطة الركود (θ). الاشكال الجديدة للاسطوانة تم مقارنتها مع الشكل الاسطواني واوضحت النتائج ان اعلى انتقال للحرارة يتم بواسطة الشكل ( نوع 7).


Article
GENETIC ALGORITHMS BASED OPTIMIZATION DESIGN OF TUNNING A PID CONTROLLER
تمثيل أنظمة السيطرة ذات الدرجة الخماسية باستخدام برنامج الماتلاب وتحسين ادائها باستخدام المسيطر الثلاثي المنغم بالخوارزميات الجينية

Loading...
Loading...
Abstract

The main aim of this paper is to tune a PID controller to enhance the out put response of fifth order modal with sensor in feedback control system . This controller tuned by genetic algorithms, because the fifth order system is notoriously difficult to control optimally using conventional PID controller. Genetic Algorithms (GA) are effective at finding high performance areas in large domains and the ideal choice to tune the PID controller can be achieved. Genetic Algorithms were examined in detail, it was decided to create an objective function which evaluates the optimum PID gains based on the controlled systems overall error. GA’s outperformed standard tuning practices, e.g. Ziegler Nichols, at designing of PID controllers, in the tests carried out. Experimentally, it can be determined that the Integral Square Error (ISE) performance criterion produces the most effective PID controllers compared with other performance criterionالهدف الرئيسي في هذا البحث هو انشاء مسيطر ثلاثي (PID)منغم بطرق ذكية لتحسين اداء انظمه من الدرحة الخماسية تحوي على متحسس في الاشارة الراجعه من الاخراج , هذا المسيطر تم تنغيمه باستخدام الخوارزميات الجينية GA . حيث ان يصعب السيطره على هكذا نوع من الانظمة عليها باستخدام المسيطر الثلاثي المنغم بالطرق التقليدية مثل طريقة (Ziegler Nichols) الخوارزميات الجينية ذات تاثير كبير في ايجاد المتغيرات للمسيطر الثلاثي وقد اختبرت الطريقة واستخدم عامل (ISE) لايجاد الاستجابة الجيده .تم الحصول على نتائج جيده ذات معامل خط قليل أي استجابه جيده وقورنت النتائج مع الطرق السابقة للتنغيم واوضحت بان هذه الطريقه الذكيه بالتنغيم جيده جدا .


Article
COMPARISON BETWEEN SIMULATED AND CALCULATED POWER OF THE SOLAR CHIMNEY WITH BLACK CONCRETE BASE USING ANSYS PROGRAM
مقارنة بين القدرة النظرية والمحسوبة لمدخنة شمسية ذات قاعدة كونكريتية سوداء بأستخدام برنامج ANSYS

Loading...
Loading...
Abstract

A solar chimney has been analyzed by solving its governing equations and compare with the simulated results. The solar absorbent of the chimney is selected as a black painted concrete, which is useful as an energy saver at night. The numerical simulation using ANSYS, based on solving the governing equations with suitable assumptions and boundary conditions for many variables such as the collector area, the chimney height, the ambient temperature, and the exit area of the chimney. The results shows that the chimney height and base area are very important parameters for improving the gained power, and it is also important to choose the region with suitable mean ambient temperature. And economically there are limitations to collector and chimney sizes to get suitable profit output power and any increment in system size becomes a small percentage increment in profit output power. The results compared with some experimental data from other results researchers and there is a good agreement between simulated and calculated resultsتم تحليل المدخنة الشمسية عن طريق حل المعادلات الحاكمة ومقارنة النتائج مع نتائج المحاكاة. إن اللوح الماص للمدخنة الشمسية تم اختياره من الكونكريت المطلي باللون الاسود والذي يعتبر مفيدا لخزن الحرارة ليلا. إن المحاكاة العددية باستخدام برنامج ANSYS 11.0 تم بناءه على حل المعادلات الحاكمة مع الفرضيات والشروط الحدية المناسبة لعدة متغيرات مثل مساحة المجمع ارتفاع المدخنة ودرجة حرارة المحيط و مساحة مخرج المدخنة. أظهرت النتائج أن ارتفاع المدخنة ومساحة المجمع هي عوامل مهمة جدا لتحسين القدرة الناتجة، وكذلك من المهم اختيار المنطقة بمعدل درجة حرارة محيط مناسبة.وان هناك محددات اقتصادية لحجم المدخنة والمجمع الشمسي للحصول على قدرة خارجة مناسبة وان أي زيادة في الحجم يقلل من نسبة الزيادة في القدرة الخارجة المفيدة. ناظرت النتائج في هذا البحث مع بعض النتائج التجريبية لباحثين آخرين وان هناك تقاربا جيدا بين نتائج الحسابات والمحاكاة .

Table of content: volume:3 issue:3