Numerical Study of Heat Transfer Enhancement in Heat Exchanger Using AL2O3 Nanofluids
دراسة عددية لتحسين انتقال الحرارة داخل مبادل حراري باستخدام نانو اوكسيد الالمنيوم-الماء

Author: Hussein Talal Dhaiban حسين طلال ذيبان
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 4 Pages: 98-115
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this study, the flow and heat transfer characteristics of Al2O3-water nanofluids for a range of the Reynolds number of 3000, 4500, 6000 and 7500 with a range of volume concentration of 1%, 2%, 3% and 4% are studied numerically. The test rig consists of cold liquid loop, hot liquid loop and the test section which is counter flow double pipe heat exchanger with 1m length. The inner tube is made of smooth copper with diameter of 15mm. The outer tube is made of smooth copper with diameter of 50mm. The hot liquid flows through the outer tube and the cold liquid (or nanofluid) flow through the inner tube. The boundary condition of this study is thermally insulated the outer wall with uniform velocity at (0.2, 0.3, 0.4 and 0.5 m/s) at the cold loop and constant velocity at (0.5 m/s) at the hot loop.The results show that the heat transfer coefficient and Nusselt number increased by increasing Reynolds number and particle concentration. Numerical results indicate that the maximum enhancement in Nusselt number and heat transfer coefficient were 9.5% and 13.5% respectively at Reynolds number of 7100 and particles volume fraction of 4%. Results of nanofluids also showed a good agreement with the available empirical correlation at particles volume fractions of 1%, 2% and 3%, but at volume fractions of 4% a slight deviation is obtained.

تمت عددياً دراسة خواص الجريان وانتقال الحرارة لمائع نانو اوكسيد الالمنيوم-الماء لمدى من عدد رينولدز 3000, 4500, 6000 و 7500 مع مدى من التركيز الحجمي لللدقائق من 1%, 2%, 3% و 4%. يتألف جهاز الاختبار من دورة باردة ودورة حارة مع جريان متعاكس للمائع داخل انبوب مزدوج متحد المركز بطول متر واحد. الانبوب الداخلي مصنوع من النحاس الاملس بقطر يعادل 15 مليمتر. والأنبوب الخارجي مصنوع من النحاس الاملس بقطر يعادل 50 مليمتر. جريان المائع الساخن خلال الانبوب الخارجي وجريان المائع البارد (او النانوي) خلال الانبوب الداخلي. الشروط الحدودية لهذه الدراسة هي السطح الخارجي معزول مع سرع متغيرة (0.2, 0.3 , 0.4 و 0.5)مثا للدورة الباردة وسرعة ثابتة (0.5 )مثا للدورة الساخنة. النتائج تبين ان معامل انتقال الحرارة وعدد نسيلت تزداد بزيادة عدد رينولد ومعامل التركيز الحجمي . والنتائج العددية تمثلت بأعلى نسبة تحسين لعدد نسلت ومعامل انتقال الحرارة ب 9.5% و 13.5% على التوالي عند عدد رينولد 7100 ومعامل التركيز الحجمي للجزيئات 4%.كذلك النتائج بينت توافق جيد مع معادلة عددية عند معامل التركيزالحجمي للجزيئات 1%, 2% و 3% ولكن بمعامل الكسر الحجمي 4% حدث اختلاف بسيط .


Article
Experimental Study of heat Transfer between the Shallow Fluidized bed and a Tube Bundle Immersed in it
دراسة عملية لحساب انتقال الحرارة بين طبقة مميعة ضحلة و أسطح أنابيب مغمورة فيها

Author: معن سعد الدين الدباغ Maan S. Al- Dabbagh*
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2006 Volume: 14 Issue: 4 Pages: 24-33
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract:This paper presents an experimental study of heat transfer between a shallow fluidized bed and the surface of a single horizontal tube and a tube bundle, which is immersed in it.Carbon, which is prepared from the Date stones, is used as a solid to be fluidized and a compressed air as an external fluid.The results showed that the overall heat transfer coefficient of tubes bundle, which immersed in fluidized bed is lower than single tube.The modified correlations and analysis are offered by experimental work, which shows the relations between heat transfer coefficient and superficial mass velocity.Key word: heat transfer - heat exchangers - fluidized bed heat exchangers

المستخلص: يقدم هذا البحث دراسة عملية لانتقال الحرارة بين طبقة مميعة ضحلة وسطح أنبوب أفقي وكذلك حزمة من الأنابيب الأفقية المغمورة فيها.استخدم الكاربون المحضر من نوى التمر كمادة صلبة يراد تمييعها والهواء المضغوط كمميع خارجي.دلت النتائج على أن معامل انتقال الحرارة الكلي لمجموعة من الأنابيب المغمورة في طبقة مميعة اقل من أنبوب واحد مغمور في نفس الطبقة.يعرض البحث مجموعة من المعادلات التصحيحية والتي تم التوصل أليها من خلال الجزء العملي والتي تربط بين معامل انتقال الحرارة وسرعة الكتلة الظاهرية.


Article
Study of Heat Storage in Shallow Fluidized Beds
دراسة الخزن الحراري في الطبقات المميعة الضحلة

Author: Burhan Mahmood Ahmad Al-Ali الدكتور برهان محمود احمد العلي
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2011 Volume: 19 Issue: 3 Pages: 69-75
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThis paper presents the theoretical analysis and experimental study of the performance of a shallow fluidized bed as a storage system for thermal energy.River sand is used as a bed with different height values and compressed heated air as an external fluidizing.A bundle of finned tubes is used as a heat exchanger immersed in the bed for the extraction of stored energy from the bed.Empirical correlations are offered by experimental work, which show the relations between the instantaneous local temperature within the bed and time as a function of both bed height and inlet air velocity. Keywords: Heat, Transfer, Fluidized Beds, Heat Storage,.

المستخلصيقدم هذا البحث دراسة عملية وتحليل نظري لأداء مبادل حراري يعمل بالطبقات المميعة الضحلة عند خزن الحرارة فيه.استخدم الرمل النهري وبارتفاعات مختلفة كطبقة مميعة ، والهواء المضغوط الساخن كمميع خارجي.استخدمت في البحث حزمة من الأنابيب المزعنفة كمبادل حراري مغمور داخل الطبقة من اجل حساب كمية الحرارة المخزونة في الطبقة. كما يعرض البحث مجموعة من المعادلات التجريبية والتي تم التوصل أليها من خلال الجزء العملي والتي تربط بين درجة الحرارة الموضعية والوقت اللازم لشحن المنظومة بدلالة ارتفاع الطبقة وسرعة الهواء.


Article
Prevention of Scale Formation in Heat Exchanger Pipesby Using Magnetic Field

Authors: Jassim M. Al-Kyayyat --- Abbas H. Sulaymon عباس حميد
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2007 Volume: 8 Issue: 4 Pages: 39-44
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The possibility of using the magnetic field technique in prevention of forming scales in heat exchangers pipes using hard water in heat transfer processes, also the studying the effective and controllable parameters on the mechanism of scale formation.The new designed heat exchanger experimental system was used after carrying out the basic process designs of the system. This system was used to study the effect of the temperature (40-90 °C) and water flow rate (0.6-1.2 L/min) on the total hardness with time as a function of precipitation of hardness salts from water and scale formation.Different magnetic field designs in the heat exchanger experimental system were used to study the effect of magnetic field design and strength (200-500 Gauss) on the total hardness with time as a function of precipitation of hardness saltsfrom water and scale formation.


Article
Steady Laminar Natural Convection Heat Transfer inside Air-Filled Horizontal Triangular Enclosure Containing Three Cylindrical Rods

Authors: Muneer A. Ismael منير عبد الجليل اسماعيل --- Falah Assi Abood فلاح عاصي عبود
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2011 Volume: 11 Issue: 1 Pages: 57-71
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

The natural convection heat transfer from horizontal isothermal three cylindrical rods inside equilateral triangular enclosure has been studied numerically. The enclosure is filled with air, and the heated rods are located at equal distances (E) from triangle center. A finite element software package (FLEXPDE) is used in the present study to solve the set of non-linear equations governing the process. Solutions are obtained for aspect ratio D/H=1/6 and range of distance E=0.2-0.6 and Rayleigh (Ra) number changes from 103 to 106. The effect of Ra and E were examined. Results are presented by streamlines, isotherms and Nusselt number and it indicates that the Nusselt number is significantly increase with increasing both Ra and E. A comparison of the Nusselt number was made with that obtained by [7], and showed substantial improvement to about 65% in some cases


Article
Evaluation of Correlations for Mixed Convective Heat Transfer in a Porous Vertical Cylindrical Annulus
دراسة عددية في انتقال الحرارة بالحمل المختلط خلال حلقة عمودية مملوءة بوسط مسامي

Authors: Kifah H. Hilal كفاح حامد هلال --- Eman A. Salih ايمان عبود صالح
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2011 Issue: 17 Pages: 212-229
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

This paper presents a numerical investigation of mixed convection heat transfer in vertical packed annulus with air as the working fluid . The inner cylinder is at constant temperature and the outer cylinder is insulated . The flow in the packed annulus is governed by the usual Darcy model . The analyses were carried out in the range of 10 < Ra* < 100 , 1 < Pe < 10 and 0.2 < A < 1 . The effect of each parameter on Nusselt number was explained and shown that it is increased as (Ra*) increased and (A) increased . The best analysis correlation obtained for average Nusselt number was as follows :

هذا البحث يبّين اجراء دراسة عددية، لانتقال الحرارة بالحمل المختلط للهواء المارخلال حلقة عمودية مملوءة بوسط مسامي ، الجدار الداخلي للحلقة ذو درجة حرارة ثابتة، بينما الجدار الخارجي للحلقة كان معزولاً .ان المعادلة المستخدمة في الجريان خلال الوسط المسامي هي معادلة دارسي . وقد تمت الدراسة لمدى رقم رالي المطور 10 < Ra* < 100 ورقم بكلت 1 < Pe < 10 ونسبة باعية 0.2 < A < 1 وبينت تأثير كل منها على رقم نسلت ، حيث انه يزداد بزيادة رقم رالي المطور (Ra*) والنسبة الباعية (A) . ان افضل علاقة تم الحصول عليها من التحليلات كانت كما يأتي :


Article
A comparative study between the Adomain decomposition method (ADM) and the variational iteration method (VIM)
دراسة مقارنة بين طريقة ADM و طريقة VIM

Author: Sabeeh Lafta Jasim صبيح لفتة جاسم
Journal: basrah journal of science البصرة للعلوم ISSN: 18140343 Year: 2011 Volume: 29 Issue: 1A english Pages: 85-91
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

In this paper, three cases are discussed. First, the comparison between Adomain decomposition method (ADM) and the variational iteration method (VIM). Second, the failure of ADM to solve some boundary value problems like one space-dimensional spatially homogeneous heat equation for some initial and boundary conditions. Third, using VIM when the ADM fails to be convergent

في هذا البحث تمت مناقشة ثلاثة حالات، الأولى هي مقارنة بين الطريقتين ADM و VIM ، الثانية هي فشل طريقة ADM لحل بعض مسائل القيم الحدودية مثل معادلة الحرارة ذات البعد الواحد لبعض الشروط الابتدائية والحدودية والثالثة هي استعمال طريقة VIM بديلا عنها في حل تلك المسائل.

Keywords

ADM --- VIM --- Heat equation.


Article
Two-pass heat-exchanger performance By programmable method

Author: Saosun Abd AL-Shaheed
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2012 Volume: 10 Issue: 1 Pages: 31-40
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The goal of heat exchanger design is to relate the inlet and outlet temperatures, the over all heat transfer coefficient, to the rate of heat transfer between the two fluids .The use of programming method can greatly aid in optimizing the design.In this study a programmable method [successive summation method] is developed, applied and presented here using Microsoft Visual Basic (version 6) to determine heat – transfer coefficients and the operating temperatures of a two pass heat exchanger [tube bundle permits a hot gas to pass in a-u- pattern through the exchanger with a shell side contains one – pass cooling water], has replaced the classical log-mean temperature difference , LMTD,method. As many plant heat exchanger operations are not accurately analyzed by this method, due to the correction factors associated with it, which must be obtained experimentally where complete sets of data are rare.

هدف تصميم المبادل الحراري هو إيجاد العلاقة بين درجات حرارة دخول وخروج المائع الساخن والبارد , والمعامل الإجمالي لانتقال الحرارة للمبادل مع معدل انتقال الحرارة بينهما , استخدام البرامج الحاسوبية له فائدة كبيرة في الحصول على التصميم الأمثل. تمت في هذه الدراسة إعداد واستخدام طريقة برمجية للجمع التعاقبي باستعمال برنامج مايكروسوفت البيسك المرئي (الإصدار 6) , لحساب المعامل الإجمالي لانتقال الحرارة ودرجات حرارة دخول وخروج الموائع لمبادل حراري (متقابل الانسياب) يحوي حزمة من الأنابيب ذو مسار على شكل حرف u يحوي الغاز الحار ومسار واحد للاسطوانة تحوي الماء البارد) , بدلاً من (استخدام طريقة المتوسط اللوغارتمي لفرق درجات الحرارة)حيث تعتمد الأخيرة على (معامل التصحيح) الذي يتم تعينيه تجريبياً , والتي تنقصها الدقة لاعتمادها على النتائج العملية .


Article
Effect of Heat Treatments on Sliding Wear Behavior of Medium Carbon Steel
تاثير المعاملات الحرارية على سلوك البلى الانزلاقي لفولاذ متوسط الكاربون

Author: Ahlam Abdalamir Mohamed احلام عبدالامير محمد علي
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 13 Pages: 318-328
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The aim of this work is to study the effect of heat treatments on the wear rate ofthe medium carbon steel which included normalizing and different quenchingmedia (air, oil, salt solution at concentration %25). Quenching Include heating toa temperature of 870Co and then rapid cooling. A Pin -on-Disc technique was usedto measure the wear rate under dry sliding conditions with applied and differentsliding times with constant sliding speed of disc (641 r.p.m) and hardness of thesteel disc (48 HRC).The results show that the wear rate increases with applied loads, and withincreasing sliding time for all heat treated specimens it was found that the hardnessvalues of the quench specimens at salt solution is higher than that of normalizedspecimens and quenched specimens in the oil.

تضمن هذا البحث دراسة تاثير المعاملات الحرارية على معدل البلى الانزلاقي لفولاذمتوسط الكاربون وهي المعادلة والتقسية باوساط تقسية مختلفة (الزيت، محلول ملحيبتركيز 25 %). وتضمنت التقسية التسخين عند درجة حرارة ( 870 ) م° ثم التبريد السريع لكللقياس معدل البلى (Pin – on Disc) العينات المقساة ، وقد استخدمت تقنية المسمار على القرصتحت ظروف الانزلاق الجاف وعند تسليط احمال مختلفة وتثبيت زمن الانزلاق ، وفترات انزلاقHRC ) مختلفة مع تثبيت سرعة الدورانية للقرص( 641 ) دورة/دقيقة وصلادة القرص الفولاذي48 ). وقد اظهرت النتائج ان معدل البلى يزداد بزيادة الحمل المسلط والفترة الزمنية للانزلاقلجميع العينات المعاملة حراريا واظهرت النتائج ان قيم الصلادة للعينات المقساة بالمحلول الملحياعلى من العينات المقساة بالزيت والعينات المعاملة بالمعادلة.


Article
Using heat pipes in greenhouse heating
استخدام أنابيب الحرارة في تدفئة البيت البلاستيكي

Author: Raqeeb Hummadi Rajab رقيب حمادي رجب
Journal: Journal Of Kirkuk University For Agricultural Sciences مجلة جامعة كركوك للعلوم الزراعية ISSN: 22210482 Year: 2012 Volume: 3 Issue: 2 Pages: 1-11
Publisher: Kirkuk University جامعة كركوك

Loading...
Loading...
Abstract

In the present work an instrumented heat pipe is designed, constructed and inserted inside a greenhouse to be used as a heating source during night or cloudy days in the cold months. Transferring geothermal heat from underground to the surrounding inside the greenhouse without consumption of conventional energy is one of the latest applications of the heat pipe device to transfer heat. The heat pipe is made of a sealed metal tube containing water as a working fluid. It is divided into three sections; the evaporator, adiabatic section and condenser. The buried part of the heat pipe is the evaporator section which transfers heat from the underground soil to the working fluid, which is in turn, transfers heat to the condenser where it is rejected to the surrounding inside the greenhouse. This study was conducted on a greenhouse with an area of (3.75)m2. Two heat pipes inserted at different depths inside the greenhouse soil were used to investigate the performance of this device. Results show an increase, with stability, of the environment temperature inside the greenhouse when the heat pipe is implemented in the cold and cloudy days of the cold winter months. The temperature inside the greenhouse reached (20)oC when the heat pipe inserted inside the soil to a level of(3.5)m with heat transfer rate of (126)W, while the outside temperature was about(14)oC.

في هذا البحث صمم وصنع أنبوب حراري لاستخدامه داخل البيوت البلاستيكية كمصدر للتدفئة ليلا والأيام الغائمة في الأشهر الباردة، بالاستفادة من الحرارة المخزونة في باطن الأرض بدون استهلاك للطاقة التقليدية، وذلك بتطبيق التقنية الحديثة في انتقال الحرارة بواسطة الأنبوب الحراري والذي هو عبارة عن أنبوب معدني مفرغ محكم يحتوي على الماء كمائع تشغيل. يتكون الأنبوب الحراري من ثلاثة اجزاء: المبخر، جزء ثابت الحرارة والمكثف. يدفن المبخر داخل التربة فتتنقل الحرارة من باطن الأرض إلى السائل الموجود في المبخر ثم تنقل إلى المكثف الذي بدوره يطرح الحرارة لمحيطه داخل البيت البلاستيكي. أجريت هذه الدراسة على بيت بلاستيكي بمساحة (3.75)م2 ,واستخدم اثنان من انابيب الحرارة ودفنا في التربة لمستويات عمق مختلفة تحت الأرض لمعرفة أداء الأنبوب الحراري. النتائج أظهرت زيادة واستقراراً في درجة الحرارة داخل البيت البلاستيكي في الأيام الباردة والغائمة من أشهر الشتاء الباردة وصلت إلى(20)oم، عند مستوى عمق (3.5) متر وبمعدل انتقال حرارة (126) واط بينما كانت درجة الحرارة خارج البيت البلاستيكي حوالي (14) oم

Keywords

heat pipe --- greenhouse --- heating

Listing 1 - 10 of 701 << page
of 71
>>
Sort by
Narrow your search

Resource type

article (701)


Language

English (538)

Arabic and English (80)

Arabic (76)


Year
From To Submit

2019 (30)

2018 (87)

2017 (70)

2016 (57)

2015 (74)

More...