Numerical Simulation of the Collector Angle Effect on the Performance of the Solar Chimney Power Plant
نمذجة رقمية لتاثير زاوية المجمع على سلوك الجريان في منظومة مدخنة شمسية لتوليد القدرة

Authors: Abbas J. Jubear عباس جاسم جبير --- Waheeds S. Mohammad وحيد شاتي محمد --- Arkan k. Al-Taaie اركان خلخال حسين
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2016 Volume: 12 Issue: 2 Pages: 79-89
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Sloped solar chimney system is a solar chimney power plant with a sloped collector. Practically, the sloped collector can function as a chimney, then the chimney height can be reduced and the construction cost would be reduced.The continuity, Naver-stockes, energy and radiation transfer equations have been solved and carried out by Fluent software. The governing equations are solved for incompressible, 3-D, steady, turbulent standard model with Boussiuesq approximation to develop for the sloped solar chimney system in this study and evaluate the performance of solar chimney power plant in Baghdad city of Iraq numerically by Fluent (14) software with orking conditions such as solar radiation intensity (300,450,600,750 and 900 W/m2), and collector which angle (0°, 15° and 30°).The results show that the change of collector angle has considerable effects on the performance of the system.The velocity increases when the collector angle increases and reach to the maximize value at a collector angle (30°). The temperature increase with the collector tile angle increase at solar intensity times (7:30,8:15,9,10 AM) but decrease at 12:30 PM) corresponding to solar intensitIes. The study show that Iraqi wather are suitable for this system.

ان نظام المدخنة الشمسية المائل عبارة عن مدخنة قدرة شمسية يكون فيها وضع المجمع الشمسي مائلا بزاوية والذي يمكن وصفه دالة للمدخنة,حيث بالامكان تخفيض كلفة انشاء المدخنة وذلك بسبب التخفيض الذي سوف يحصل في ارتفاع المدخنة.تم حل معادلات الاستمرارية والزخم والطاقة والاشعاع الشمسي باستخدام برنامج Fluent (14).في هذه الدراسة تم اختبار اداء المدخنة الشمسية المائلة خلال جريان لاانضغاطي ,ثلاثي الابعاد, مستقر واضطرابي حيث تم الاستعانة بالموديل الاضطرابي k-ε وذاك لحساب اداء المدخنة الشمسية تحليليا في اجواء بغداد- العراق,حيث كانت ابعاد المدخنة الشمسية الارتفاع 6 م ,قطر المجمع 6م,قطر المدخنة 0.3 م وارتفاع مدخل المجمع 0.1 م وذلك عند ظروف اختبار مختلفة ,شدة الاشعاع الشمسي (300 و 450 و 600 و 750 و900 ) واط/م2 وعند زويا ميل مختلفة للمجمع (30°, 15°, 0°) من ابرز النتائج التي توصل لها البحث هو التاثير الكبير لتغير زاوية المجمع الشمسي على اداء المدخنة الشمسية.حيث نلاحظ ازدياد سرعة الهواء داخل المدخنة بزيادة زاوية ميلان المجمع حث تصل الى اقصى قيمه عند زاوية °30 ,تم التوصل كذلك ان درجات الحرارة تزداد بزيادة زاوية المجمع الشمسي في الاوقات (7:30,8:15,9,10 ق ظ) والمناظرة لشدة الاشعاع الشمسي وتقل عند (12:30) ب ظ. بينت هذه الدراسة ايضا ان اجواء العراق ملائمة لهذا النوع من الانظمة.


Article
Basement Kind Effects on Air Temperature of a Solar Chimney in Baghdad - Iraq Weather
تأثير نوع القاعدة على درجات حرارة مدخنة هوائية في أجواء مدينة بغداد- العراق

Author: Miqdam Tariq Chaichan مقدام طارق جيجان
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2011 Volume: 7 Issue: 1 Pages: 30-38
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A solar updraft tower power plant (solar tower) is a solar thermal power plant that utilizes a combination of solar
air collector and central updraft tube to generate an induced convective flow which drives pressure staged turbines to generate electricity.

This paper presents practical results of a prototype of a solar chimney with thermal mass, where the glass surface is replaced by transparence plastic cover. The study focused on chimney's basements kind effect on collected air temperatures. Three basements were used: concrete, black concrete and black pebbles basements. The study was conducted in Baghdad from August to November 2009.
The results show that the best chimney efficiency attained was 49.7% for pebbles base. The highest collected air temperature reached was 49ºC when using the black pebbles basement also.also, the maximum basement temperature measured was 59ºC for black pebbles. High increaments in collected air temperatures were achieved in comparison with the ambient air temperatures for the three basement kinds. The highest temperature difference reached was 22ºC with the pebble ground.

تستخدم مدخنة الهواء أو البرج الشمسي تركيبة من مجمعات الهواء الشمسية وأنبوب سحب مركزي لتوليد تدفق هواء مسخن شمسيا" مستحث بالحمل، والذي يمكنة تحريك توربينات متعددة المراحل لتوليد الكهرباء.الهدف من هذا البحث هو تقديم نتائج عملية لنموذج مدخنة شمسية ذو كتلة حرارية، إذ تم استبدال السطح الزجاجي بغطاء بلاستيكي شفاف، تركزت الدراسة على تأثير نوع قاعدة المدخنة على درجات حرارة الهواء، ولقد استخدمت ثلاثة أنواع من القواعد، قاعدة كونكريتية، قاعدة كونكريتية سوداءاللون وقاعدة من الحصى الاسود اللون، وتمت الدراسة في أجواء بغداد من شهر أيلول لغاية نوفمبر 2009.تبين الدراسة أن أفضل كفاءة للمدخنة وأعلى درجة حرارة تم الوصول لها كانت 49.7% عند استخدام قاعدة من الحصى الأسود. وأعلى درجة حرارة للهواء المجمع أمكن الوصول لها كانت 49ºC باستخدام قاعدة الحصى الأسود أيضا، كما كانت أقصى درجة حرارة قيست لهذة القاعدة هي 59ºC، لقد تم الوصول لزيادة كبيرة في درجات حرارة الهواء المجمع مقارنة مع درجات حرارة الهواء الجوي للقواعد الثلاثة المدروسة، وأعلى فرق في درجات الحرارة أمكن الوصول له كان 22ºC بأرضية من الحصى الأسود.


Article
Experimental and Numerical Study of Collector Geometry Effect on Solar Chimney Performance
دراسة عملية وعددية لتأثير شكل المجمع على إداء المدخنة الشمسية

Loading...
Loading...
Abstract

There have been many advances in the solar chimney power plant since 1930 and the first pilot work was built in Spain (Manzanares) that produced 50 KW. The solar chimney power plant is considered of a clean power generation that needs to be investigated to enhance the performance by studying the effect of changing the area of passage of air to enhance the velocity towards the chimney to maximize design velocity. In this experimental and numerical study, the reduction area of solar collector was investigated. The reduction area that mean changing the height of glass cover from the absorbing plate (h1=3.8cm, h2=2.6cm and h3=1.28cm). The numerical study was performed using ANSYS Fluent software package (version 14.0) to solve governing equations. The aim of this work was to study the effect of change the height of reduction area to the design velocity (velocity move the blade of turbine at inlet in the chimney). The results showed that the third height (h3=1.28cm) gives the best result because when decreasing the height between the glass cover and absorbing plate, the area between them decreased and the design velocity increased then the efficiency of solar chimney model was increased.

تطورت محطات التوليد الكهربائية بوساطة المدخنه الشمسيه منذ سنه 1930م .محطة الطاقة الشمسية تعد مولدا للطاقة النظيفة. الدراسة الحالية هي عملية وعددية عن منطقة الانخفاض في المجمع الشمسي.منطقة الانخفاض تعني تغير الارتفاع بين سقف المجمع الشمسي وبين صفيحة الامتصاص (قاع المجمع الشمسي) التي تكون ذات بعد معين عن مركز المجمع وهذا البعد يعتمد على حجم النوذج المستعمل.دُرِسٓ تغير ارتفاعات منطقة الانخفاض عمليا وعدديا حيث تم استخدم ثلاثة ارتفاعات ( 3.8، 2.6، 1.28) سم على التوالي.الهدف من هذا البحث هو دراسه تأثير ارتفاعات منطقة الانخفاض على السرعه التصميمية (السرع الذي تقوم بتحريك ريش التوربين الموجودة عند مدخل المدخنة). بينت النتائج ان استخدام الارتفاع 1.28سم هوالافضل والسبب في ذاك عند تقليل الارتفاع بين السقف والقاع تعني تقليل من مساحه الجريان داخل المجمع الشمسي مما يؤدي الى زياده في سرعة الجريان تؤدي الى زياده كفاءة المدخنة الشمسية.


Article
Experimental Study Using the Passive Solar Chimney for Evaporative Cooling With PCM and CFM as a Thermal Energy Storage
دراسة عملية لاستخدام المدخنة الشمسية السلبية في التبريد ألتبخير مع مادة ثنائية الطور ومصفوفة رغوة النحاس كخزان حراري

Authors: Ali D. Salman علي داود سلمان --- Hussien M. Salih حسين مجيد صالح --- Talib K. Murtadha طالب كشاش مرتضى
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2016 Volume: 12 Issue: 3 Pages: 80-98
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this work, a test room was built in Baghdad city, with (2*1.5*1.5) m3 in dimensions, while the solar chimneys (SC) were designed with aspect ratio (ar) bigger than 12. Test room was supplied by many solar collectors; vertical single side of air pass with ar equals 25, and tilted 45o double side of air passes with ar equals 50 for each pass, both collectors consist of flat thermal energy storage box collector (TESB) that covered by transparent clear acrylic sheet, third type of collector is array of evacuated tubular collectors with thermosyphon in 45o instelled in the bottom of TESB of vertical SC. The TESB was made from metallic iron sheets as a shell and fuelled by paraffin wax as phase change material (PCM). The PCM supported by copper foam matrix (CFM) to enhance thermal conductivity of wax. When heat is released from TESB to the air, a buoyancy force will be generated in chimney gaps. Then a difference in pressure between inside and outside test room leads to induce the air flow to test room through wet corrugated cellulose pad, where evaporative cooling (EC) occurs. Results of experimental work, that achieved in June, for 12 to24 hour in the test day, refer to effectiveness using EC to decrease the room temperature comparing. The system reduces test room temperature of up to 8.5~9.2 oC in 11:00 am to 3:00 pm and at highest effectiveness of EC, while minimum reduces in temperature of up to 3.5 oC in 8:00pm to 3:00 am. Also, the results showed the affectivity to using the TESB, during the night time for ventilation and EC, with lower effectiveness than from day time. The range of EC effectiveness equals 30.5-37.5 with a natural vent, while The maximum air change per hour (ACH) equals (3.8-6.187), and the maximum mass flow rate is equal to (36.651 kg.hr-1) at experimental evaluation of the system’s discharge coefficient value 0.371.

خلال هذه الدراسة العملية, تم بناء غرفة اختبار معزولة بحجم (2*1.5*1.5) متر لكل من الطول والعرض وارتفاع الغرفة المبنية في في مدينة بغداد . بينما صمم كلا المداخن الشمسية ضمن نسبة طول الى عرض الفجوة الهوائية بمقدار اكبر من القيمة الحرجة 12. جهزت غرفة الاختبار بعدة أنواع من المجمعات الشمسية, فهنالك المدخنة العمودية الثابتة ذات الخزان الحراري المسطح والمدهون بدهان اسود غير لماع ومغلفة بسطح نفاذ للضوء وعازل حراريا, وهنالك المدخنة المائلة بزاوية 45 درجة والموصولة بالتوالي مع المدخنة الثابتة لزيادة ارتفاع المدخنة الكلي وتحسين توليد قوة الطفو, في هذه المدخنة ثلاثة خزانات حرارية على طول المدخنة مع وجود فجوتي هواء على طرفي المجمع لجريان الهواء خلالهما من خلال توليد قوة الطفو الازمة عن طريق زيادة انتقال الحرارة الى الهواء مع تامين منع حدوث جريان هواء خلفي. كما تم زراعة مجموعة من الانابيب الزجاجية المزدوجة والمفرغة من الهواء والتي في داخل كل واحده منها انبوب حراري وبدون حشوة (ثرموسايفون) حيث توصل هذه الانابيب المميلة بزاوية 45o الى النصف السفلي من الخزان الحراري للمدخنة الشمسية العمودية الثابتة. تم خزن حرارة الإشعاع الشمسي في المدخنة الشمسية باستخدام خزانات معدنية مغلونة تحتوي على مواد متغيرة الطور لها قابلية على خزن الحرارة ومدعمة برغوة معدنية لتحسين الموصلية الحرارية لمادة الخزن. تستخدم الحرارة المخزونة لتوليد قوة الطفو ومن ثم حث الهواء خلال المدخنة الشمسية وعمل تخلل ضغط داخل الغرفة, للسماح للهواء الخارجي النقي بالدخول عبر فتحات تحتوي على حشوه سليلوزية لها القابلية على امتصاص الماء, وبمرور الهواء فوق سطح الحشوة المبتلة مما يؤدي إلى حدوث التبريد ألتبخيري. أظهرت النتائج العملية والتي تم إجرائها في بداية ومنتصف الشهر السادس, إلى إمكانية خفض درجة حرارة حيز الاختبار ضمن فترة اختبار 24 ساعة متواصلة, حيث إن اقل فرق درجة حرارة بين حيز الاختبار وظرف الهواء الخارجي كانت ما يقارب 3.5 درجة مئوية عند الساعة 20:00 مساءا وكذلك بفرق مماثل يحدث عند الساعة 03:00 صباحا, اما اعلى فرق في درجة الحرارة بمقدار 9.2-8.5 درجة مئوية ويحدث خلال 11:00- 15:00 من عمر فترة الاختبار. كما أظهرت النتائج فعالية استخدام الخزن الحراري الشمسي, لفترة ما بعد المغيب مع ملاحظة انخفاض في فعالية التبريد التبخيري , بلغت مدى فعالية التبريد التبخيري 30.5- 37.5 ضمن جريان الهواء الطبيعي, اما تهوية الحيز فكان بمعدل (3.8-6.187) خلال الساعة ضمن معامل تدفق خلال المنظومة 0.371, واكبر معدل تدفق كتلي للهواء فكان بمقدار .(36.651 kg.hr-1)


Article
Transient Behavior Analysis for Solar Energy Storage in PCM-CFM Material Using Equivalent Heat Capacity Method as Storage Model
تحليل السلوك غير المستقر لطاقة الأشعة الشمسية المخزنة في المادة ثنائية الطور المدعمة برغوة النحاس باستخدام طريقة السعة الحرارية المكافئة كنموذج خزن

Authors: Ali D. Salman علي داود سلمان --- Hussien M. Salih حسين مجيد صالح --- Talib K. Murtadha طالب كشاش مرتضى
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2018 Volume: 14 Issue: 2 Pages: 40-57
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A paraffin wax and copper foam matrix were used as a thermal energy storage material in the double passes air solar chimney (SC) collector to get ventilation effect through daytime and after sunset. Air SC collector was installed in the south wall of an insulated test room and tested with different working angles (30o, 45o and 60o). Different SC types were used; single pass, double passes flat plate collector and double pass thermal energy storage box collector (TESB). A computational model based on the finite volume method for transient tw dimensional domains was carried out to describe the heat transfer and storage in the thermal energy storage material of collector. Also, equivalent specific heat method was employed to describe the heat storage and release in the mushy zone. Experimental results referred to an increase in thermal conductivity of paraffin wax that supported by copper foam matrix more than ten times. While the ventilation effect was still active for hours after the sun set, depending on the heat storage amount. Maximum ventilation mass flow rate with TESB collector was recorded with value equals to 36.651 kg/hr., when the overall discharge coefficient that was calculated for the system equals to 0.371. Experimental results showed that the best working angle range was 45~60o, and the highest air to the collector approaching temperature appeared to the double passes flat plate collector. Results gave greater heat storage efficiency of (47)% when the maximum solar radiation was 780 W/m2 at 12.00pm, while the energy summation through duration charge time was 18460 kJ. Computational results, depending on the equivalent heat capacity method for heat storage or release from phase change material that supported by copper foam matrix, showed the behavior of paraffin wax melting and solidification situation through periodic for charge and released heat from the solar collector. Also, these results gave agreement approaching the experimental results for the heat storage in the combined heat storage material, with standard error of 16.8%.

تم استخدام الشمع البرافيني المدعم برغوة النحاس بوصفه مادة خزن حراري وتوظيفه ضمن المدخنة الشمسية ثنائية المجرى للحصول على تأثير التهوية او التهوية مع التبريد ألترطيبي خلال وبعد غياب الشمس. المدخنة الشمسية تم تنصيبها ضمن الجدار المواجه الى الجنوب لغرفة الاختبار المعزولة حراريا والتي تم فيها اختبار المدخنة الشمسية ضمن زاوية عمل مختلفة (60o, 45o and 30o) ولثلاثة انواع من المداخن الشمسية وهي المدخنة ذات الممر الهوائي الأحادي والمزدوج فضلا عن المدخنة ذات الممر الهوائي المزدوج ذي ماص حراري بشكل صندوق خزن حراري يحوي مادة الشمع البرافيني المدعم برغوة النحاس. تم بناء برنامج محاكاة لحل النموذج الحسابي للجزء غير المستقر (العابر) وذلك باستخدام طريقة الحجوم المحددة، حيث ان انتقال الحرارة وخزنها تم تمثيله عن طريق المعادلات الحاكمة (معادلة) الطاقة والتي تم استخدامها بشكل دالة لدرجة الحرارة، كذلك تم توظيف طريقة الحرارة النوعية المكافئة لوصف خزن الحرارة في المنطقة الثنائية الطور الانتقالية والتي تعد من أسهل الطرائق وادقها المستخدمة في وصف انتقال الحرارة وخزنها في المادة ثنائية الطور والمتحوله من الصلب الى السائل وبالعكس وبفعل كسب او فقدان الحرارة. النتائج العملية أشارت الى زيادة الموصلية الحرارية بعشرة اضعاف للمادة ثنائية الطور بعد تدعيمها برغوة النحاس، بينما تأثير التهوية يبقى فعالا ولمدة ساعات مع تأثير اقل بعد غياب المصدر الحراري (الشمس) وبالاعتماد على السعة الحرارية المخزونة. بينت النتائج العملية ان اكبر معدل تدفق كتلي للهواء تم تسجيله بمقدار36.651 kJ/hr. والتي عندها قيمة معامل التدفق المحسوب لهذه المنظومة بمقدار 0.371. كذلك اظهرت النتائج العملية أفضل زاوية عمل 45o-60o، وان نسبة اقتراب درجة حرارة الهواء من درجة حرارة السطح الماص والتي اظهرت اعلى قيمة عند المدخنة الشمسية ثنائية المجرى, اظهرت النتائج العملية ان المدخنة الشمسية ذات مواد الخزن الحرارية تظهر تأثير لفترة طويلة حتى بعد غياب الشمس لكن مع تأثير حراري اقل نتيجة الحفاظ على درجة حرارة مستقرة تمثل درجة الانصهار للمادة الثنائية والتي تحدد فيها درجة الحرارة بالثبات على الرغم من اكتساب الحرارة، النتائج أشارت الى اعلى كفاءة لخزن الحرارة ضمن مادة الخزن المركبة وبمقدار 47% عند اعلى مقدار للإشعاع الشمسي 780W/m2 ضمن ظروف الاختبار عند وقت الاختبار 12:00 pmوالسبب في ذلك يعود الى اكتساب الهواء المار في المدخنة جزء من الحرارة المخزنة لدوام استمرارية عمل المنظومة وهذا يحدث بسبب فرق درجات الحرارة , بينما سجل مجموع الطاقة خلال مدة الشحن الحراري بمقدار18460 kJ . النتائج الحسابية أظهرت سلوكا منطقيا لذوبان الشمع وتصلده خلال مدة شحن الحرارة واطلاقها بوجود الرغوة المعدنية، مع تقارب منطقي للنتائج النظرية من العملية وبمعدل خطا يصل الى 16.8% حيث تم اعتماد طريقة الحرارة النوعية المكافئة لحساب الحرارة المخزونة في المادة ثنائية الطور المدعمة برغوة النحاس.