research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
Hardness Removal from Drinking Water

Authors: Ahmed A. M. Ali --- Nawar O. A. Nasser
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2006 Volume: 12 Issue: 2 Pages: 405-413
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study included three trials that were made during December 2003 by using lime, of 98% w/w calcium hydroxide to find the relation between lime doses to be added and the hardness removed .The trials were performed by adding various doses of lime and measuring the hardness, electrical conductivity and pH in water produce by three plants, Nissan in the north of Baghdad, Al-Karama and Al-Wathba water treatment plant in Baghdad center. The objective of this study is to find the optimum lime dose that gives the minimum hardness content.The results indicate a non linear relation between lime dose added and the hardness removed . The results represented a 36% removal in hardness when using an optimum dose of lime 200 ppm in Nissan water treatment plant, while a percentage removal of 34% was obtained in both Al-Karama and Wathba water treatment plants with 300 ppm dose of lime.The low percentage removal indicates the presence of non-carbonate hardness which could not be removed by lime alone.

تضمنت هذه الدر اسه ثلاث محاولات أجريت خلال كانون الأول 2003باستخدام هيدروكسيد الكالسيوم 98% نسبه وزنيه لإيجاد العلاقة بين جرعة هيدروكسيد الكالسيوم وإزالة العسرة ,المحاولات تمت بإضافة جرع مختلفة من هيدروكسيد الكالسيوم وقياس العسرة والتوصيل الكهربائي وقوة أيون الهيدروجين للماء المسحوب من ثلاث محطات لتصفية ماء الشرب وهي مشروع نيسان شمال مدينة بغداد ,مشروع الكرامة ومشروع الوثبة مركز مدينة بغداد ,الهدف من هذه الدر اسه هو إيجاد الجرعة القصوى من هيدروكسيد الكالسيوم التي تعطي اقل تركيز للعسره. النتائج أظهرت أن هناك علاقة لا خطيه بين جرع هيدروكسيد الكالسيوم المضافة والعسره المزالة ,النتائج تمثلت بإزالة 36% من العسره عند إضافة أقصى جرعه من هيدروكسيد الكالسيوم 200 ملغملتر في مشروع نيسان بينما نسبة أزاله 34% تم الحصول عليها في مشروعي الكرامة والوثبة لجرع 300 ملغملتر النسبة القليلة للازاله أشارت إلى وجود عسره لا كاربونيه والتي لا يمكن أزالتها باستخدام هيدروكسيد الكالسيوم لوحده


Article
Evaluation of a Number of Water Treatment Plants in Kirkuk Governorate using the Water Quality Index

Authors: AbdulRazaq Khader Abdul Wahid --- Idan I. Ghdhban --- Rodhan Abdullah Salih
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2018 Volume: 25 Issue: 1 Pages: 49-59
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

A study was conducted on sixteen water purification plants in Kirkuk governorate to evaluate the treatment of water in them, where physical and chemical tests were conducted for raw water and treated water for a period of (6) months from December until May. Temperature, turbidity, pH, Total Dissolved Solid (TDS), Electric Conductivity (EC), alkali, Total Hardness (TH) and calcium (Ca+2) were measured. Water quality index Canadian method (CCME) was used to classify raw water quality and treated water. The results showed that the raw water for all stations was classified as category (4) (bad) during the study period. The treated water was different for the treatment plants. Two of the treatment plants recorded good efficiency in water treatment (AL-Shallalah plant and Sin AL-Thiban) the treated water remained in category (2) (good). While the water quality of AL-Mosanaa plant indicated that there was a problem in the treatment of water in this plant, the treated water remained in category (4) bad during the study period. Water quality index fluctuated for other plants during the study period. The study also showed that alkali values of all stations were higher than the allowable limit for raw water and treated water.


Article
IRAQI WATER TREATMENT PLANTS PROCESS CONTROL BY MEASURING EFFLUENT TURBIDITY
السيطرة على وحدات معالجة مياة الشرب في العراق بقياس كمية العكورة الناتجة

Authors: Jwad Khadhum. Ghaziy م.م. جواد كاظم غازي --- Ali H. GHAWI1 د.علي هادي غاوي
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2010 Volume: 3 Issue: 4 Pages: 373-381
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The Al-Dewanyia Water General Authority (DWGA) operates and maintains four water treatment plants to produce potable water for 300,000 inhabitations in Al-Dewanyia city. Surface water from Al-Dewanyia river is treated by aluminum sulphate (alum) coagulation, flocculation, sedimentation, filtration, and chlorine disinfection (clearwell). DWGA has set goals for turbidity for clarified and filtered water. These goals pertain to water inside the Water Treatment Plant (WTP), outside the water treatment plant, and in the distribution system, DWGA continues to meet the Iraqi Ministry of Health Standard of 5 NTU. Each day at DWGA WTPs, chemists measure the turbidity of water from each individual clarifier and from each individual filter. The WTP Manager reviews this data and uses it to make process control decisions about chemical dosage and filter backwash. This paper explains DWGA’s Turbidity Goal for filtered water, presents recent data, and describes how WTP managers use this data for process control. Any water treatment plant in Iraq can use these procedures. The results can be better process control and higher quality water

مديرية ماء الديوانية تشغل و تصين اربعة محطات لمعالجة مياه الشرب في مدينة الديوانية و التي تخدم 300,000 ألف نسمة. ان مصدر المياه المعالج هو نهر الديوانية و تستخدم وسائل التلبيد (إضافة الشب) و التخثير و الترسيب و الترشيح و التعقيم في تصفية المياه. مديرية ماء الديوانية و ضعت أهداف لإزالة العكورة من حوضي الترسيب و الترشيح. هذة الأهداف تتمثل بالحصول على ماء صالح للشرب و مطابق للمواصفات العراقية و البالغة NTU 5 . تم قياس تركيز العكورة يوميا من أحواض الترسيب و أحواض الترشيح. المهندسين المسئولين عن تشغيل المشروع قاموا بتحليل تلك القياسات لاتخاذ قرار حول مقدار الشب المضاف و عملية غسل الفلاتر. من خلال هذا البحث تم توضيح وسيلة فعالة من خلال القياسات اليومية لتركيز العكورة للحصول على ماء مطابق للمواصفات العراقية.ان هذة التقنية يمكن استخدامها في أي محطة معالجة لمياه الشرب في العراق.


Article
PERFORMANCE EVALUATION OF AL-DEWANYIA WATER TREATMENT PLANT IN IRAQ
تقيم أداء محطة معالجة مياه الشرب في مدينة الديوانية

Author: د . علي هادي غاوي,د. عباس عليوي الجبوري
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2009 Volume: 2 Issue: 4 Pages: 664-677
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

In order to design and operate an effective water treatment system, a thorough understanding of the process of coagulation-flocculation and filtration is essential in the delivery of water of the greatest clarity and lowest possible turbidity in the finished water. This research outlines the finding of investigation of the treatment plant in Al-Dewanyia in Iraq. Performance of Al-Dewanyia Water Treatment Plant in Iraq is an essential parameter to be monitored and evaluated to better understanding of design and operating difficulties in water treatment plants. The conclusions of these evaluations may determine required recommendations and highlight modification requirements for continuous design and operating schemes. The evaluation conducted in this research was carried out by reviewing the engineering design to assure matching of standards and codes. Also, physical (turbidity and TSS) , and biological, analysis were conducted to investigate water quality. The conclusions drawn from this research outlines the importance of accurate engineering design and need for continuous monitoring and analysis of each unit performance. Finished water is not conforming to World Health Organization (WHO) Standard for Drinking water.

لتصميم و تشغيل محطات معالجة مياه الشرب بكفاءة عالية, يتطلب أدراك شامل لعمليات و مراحل معالجة مياه الشرب من تخثير, تلبيد و ترشيح لغرض أنتاج مياه صالحة للشرب و تقليل العكورة إلى أدنى حدود مسموحه. يلخص هذا البحث تقيم أداء محطة معالجة مياه الشرب في مدينة الديوانية في العراق. يعتبر تقييم أداء محطة معالجة مياه الشرب في مدينة الديوانية عامل ضروري و مهم لمراقبة و تقيم و فهم صعوبات التصميم و التشغيل لمحطات معالجة مياه الشرب في العراق لان معظم محطات المعالجة في العراق لها نفس التصميم الهيدروليكي ومصدر المياه هو النهر (مياه سطحية) و لكن تختلف في مقدار التدفق. في هذا البحث تم تقييم التصميم الهندسي لمحطة المعالجة لغرض التأكد من مطابقته للمحددات التصميمية. و لغرض تقييم نوعية الماء الناتج من المحطة تم قياس العكورة, المواد الصلبة العالقة, و الملوثات الحيوية في مختبر محطة المعالجة. و من أهم نتائج هذه الدراسة هو وجوب الاهتمام بتصميم محطات المعالجة و المراقبة المستمرة لمراحل المعالجة و تحليل أداء كل مرحلة. ان نوعية الماء الناتج ن محطة المعالجة لا يتوافق مع معاير ومحددات منظمة الصحة العالمية لمياه الشرب.


Article
Upgrading of Alum Preparation and Dosing Unit for Sharq Dijla Water Treatment Plant by Using Programmable Logic Controller System
تطوير وحدة إضافة جرعة الشب لمشروع ماء شرق دجلة باستخدام منظومة السيطرة المنطقية PLC

Authors: Aumar Al-Nakeeb عمر نجدت النقيب --- Adnan A. Al-Samawi عدنان عباس السماوي --- Huda A. Al-Saffar هدى عدنان الصفار
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 2 Pages: 131-141
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

One of the important units in Sharq Dijla Water Treatment Plant (WTP) first and second extensions are the alum solution preparation and dosing unit. The existing operation of this unit accomplished manually starting from unloading the powder alum in the preparation basin and ending by controlling the alum dosage addition through the dosing pumps to the flash mix chambers. Because of the modern trend of monitoring and control the automatic operation of WTPs due to the great benefits that could be gain from optimum equipment operation, reducing the operating costs and human errors. This study deals with how to transform the conventional operation to an automatic monitoring and controlling system depending on a Programmable Logic Controller (PLC) and online sensors for alum preparation and dosing unit in Sharq Dijla WTP. PLC system will receive, analyze transmitting data, compare them with preset points then automatically orders the operational equipment (such as pumps, valves, and mixers) in a way that guarantees the safe and appropriate operation of the unit. As a result of Process and Instrumentation Diagrams (PID) that were prepared in this study, these units can be fully operating and manage by using Supervisory Control and Data Acquisition (SCADA) system.

تعد وحدة تحضير وأضافة الشب من الوحدات المهمة في مشروع ماء شرق دجلة بتوسعيه الأول والثاني. حيث تتم أدارة عمليات تحضير وأضافة الشب في احواض التحضير بصوره يدوية بدءاً من أضافة مسحوق الشب وانتهاءً بعملية تعديل جرع الشب المضافة عن طريق مضخات اضافة جرع الشب الى أحواض المزج السريع. وبالنظر للتوجه الحديث في السيطرة والمراقبة الاوتوماتيكية لمشاريع الماء لما يوفره من منافع متعددة سواء في التشغيل الامثل للمعدات، وتقليل كلف التشغيل والأخطاء البشرية. فهذه الدراسة تعنى بتحويل نظام التشغيل التقليدي لوحدة تحضير واضافة الشب للمشروع الى منظومة سيطرة ومراقبة أوتوماتيكية اعتمادا على جهاز سيطرة مبرمج (PLC) ومتحسسات. حيث تقوم هذه المنظومة باستلام وتحليل البيانات المنقولة ومقارنتها بعدد من القيم مسبقة الضبط وتوجيه الاوامر للمعدات التشغيل (مثل المضخات والصممات واجهزة المزج) بما يضمن التشغيل الامثل والأمن لهذه الوحدة. كنتيجة لمخططات أجهزة العمليات PID المعدة في هذه الدراسة، يمكن لهذه الوحدات ان تشغل وتدار بواسطة منظومة التحكم الاشرافي واستحصال البيانات SCADA.


Article
Optimization of the Horizontal Sedimentation Tank to Predict Turbidity Removal Efficiency in Water Treatment Plant in Iraq

Authors: Ali. Hadi . Ghawi --- Yaser. Ibrahim. Jasem ياسر ابراهيم جاسم
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2018 Volume: 11 Issue: 1 Pages: 33-37
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The goal of this research was to design and evaluate the efficiency of horizontal sedimentation tank for water treatment using different position of baffles. Turbid water was treated using alum in the condition with and without baffle in the settling unit. Turbidity was the main determinant in assessing the effectiveness of the settling tank processes. Visualization and profiling research was done using a dye tracer. Samples were collection at different baffle horizontal and vertical height, different flow rates and turbidity with respect to time. Baffle position was found to be capable of increasing turbidity removal efficiency considerably in the settling tank by diminishing the surface loading rate and increasing the retention time. Simulation displayed that turbidity can be eliminated higher than 95%. The type of water purified using optimum position of baffle was well below the WHO guideline for drinking water of <5 NTU.


Article
Performance Assessment of AL-Hussein City Water Treatment Plant In Holly Karbala Governorate (HCWTP) By Statistical Program

Author: Fatin Abdulkadhium M. alnasrawi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 4 Pages: 1151-1168
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This study aimed of a assessment performance al- Hussein City water treatment(HCWTP) that located in the northeastern part of the holy Karbala city. the evaluation of performance and comparison the result with standard limits were achieved After a development of statistical models that have been modeled by non-linear regression for the raw water quality parameter data of al-husayniyah river influent to the plant and the water effluent data from the plant for the same parameter but after treatment by using ,(Datafit) program version 9.1 software Such as these models approved that its very efficient and fast, and its can using at any time in the future especially at emergency condition to estimate the efficiency of plant, but it does not take some of the external conditions into account affecting the quality of the water, in general its very good application when you used in estimating the efficiency of plant. The results of this study showed after comparison with the Iraqi standard that all the properties of water of al-husayniyah river matching to the standard limits except Electrical conductivity recorded 1159.79 mhos/cm, 1183.4mhos/cm for hot and cold season respectively, its value higher than limitation. while the efficiency of al (HCWTP) is57.103%, 62.11% for hot and cold season respectively from the multi-regression efficiency model while the efficiency from single-regression is 44.25%,48.18% also for two season. so, the discharge of the plant has a evident effect in the estimation of the removal efficiency of each parameters as well as the overall efficiency of plant, But it is not the only element affecting in the estimation of the overall efficiency , for this reason the efficiency from multi-regression considered more accurate than from single- regression

تم اجراء هذه الدراسة من خلال تقييم أداء محطة مدينه الحسين لتنقيه المياه الواقعة في الجزء الشمالي الشرقي في محافظه كربلاء المقدسة وتم التقييم والمقارنة مع المواصفات القياسية بعد تطبيق الموديلات الإحصائية التي تم نمذجتها من عملية الانحدار اللاخطي لبيانات معاملات المياه الخام لنهر الحسينية الداخلة للمحطة والخارجة منها بعد المعالجة باستخدام البرنامج الإحصائي data fit نسخة 9.1 , هذا واثبت أن مثل هذه الموديلات يمكن استخدامها في أي وقت بالمستقبل وأنها كفوءة وسريعة في حاله الطوارئ لكنها لا تأخذ بنظر الاعتبار بعض الظروف الخارجية المؤثرة على نوعية الماء لكن على العموم تعتبر جيد جدا في حالة الاستعانة بها في تقدير كفاءة محطة المحطة. وأظهرت النتائج بعد المقارنة مع المواصفة العراقية إن جميع مواصفات الماء الخام لنهر الحسينية مطابقة للمواصفات القياسية ماعدا التوصيل الكهربائي سجل قيم 1159.79( S/cm) و 1183.4( S/cm) للموسم الحار والبارد على التوالي وهي قيم أعلى من المحددات. أما فيما يخص كفاءة محطة مدينة الحسين لتنقية الماء سجلت قيم57.103% و 62.11% للموسم الحار والبارد على التوالي من نموذج الانحدار اللاخطي المتعدد للكفاءة حيث إنها تعطي نتائج أكثر دقة من نموذج الانحدار اللاخطي المنفرد حيث سجلت الكفاءة 48.18% و44.25, ومن هذا تبين أن تصريف المحطة له تأثير واضح في تقدير كفاءة الإزالة لكل عنصر وأيضا الكفاءة الكلية لها , إلا انه ليس العنصر الوحيد المؤثر في تقدير الكفاءة الكلية ولهذا السبب يعزى دقة نتائج تقدير الكفاءة من نموذج الانحدار اللاخطي المتعدد.


Article
Application of Artificial Neural Network for Predicting Iron Concentration in the Location of Al-Wahda Water Treatment Plant in Baghdad City
استخدام شبكة الخلايا العصبية لتوقع تركيز ايون الحديد في محطة الوحدة لمعالجة المياة في مدينة بغداد

Author: Nawar Omran Ali Al-Musawi نوار عمران علي الموسوي
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 9 Pages: 72-82
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Iron is one of the abundant elements on earth that is an essential element for humans and may be a troublesome element in water supplies. In this research an AAN model was developed to predict iron concentrations in the location of Al- Wahda water treatment plant in Baghdad city by water quality assessment of iron concentrations at seven WTPs up stream Tigris River. SPSS software was used to build the ANN model. The input data were iron concentrations in the raw water for the period 2004-2011. The results indicated the best model predicted Iron concentrations at Al-Wahda WTP with a coefficient of determination 0.9142. The model used one hidden layer with two nodes and the testing error was 0.834. The ANN model could be used to predict future iron concentrations as the results from the verification of the ANN model for years 2012 and 2013 indicated good accuracy with a coefficient of determination R2 = 0.8965.

يعتبر الحديد احد العناصر المهمة على الارض وذو اهمية اساسية للانسان وقد يسبب مشاكل كيمياوية في مياة الشرب, في هذا البحث تم بناء نموذج رياضي بالاعتماد على مبدا الخلايا العصبية في تقدير تركيز الحديد في موقع محطة الوحدة لمعالجة مياة الشرب وذلك عن طريق تقييم نوعية مياة نهر دجلة بالاعتماد على عنصر الحديد في مواقع المحطات السبعة لمعالجة مياة الشرب في مدينة بغداد وقد استخدم البرنامج الاحصائي SPSS في بناء النموذج الرياضي. تراكيز الحديد المستخدمة في النموذج كانت للفترة بين 2004-2011 وقد اظهرت النتائج من النموذج ان معامل التحديد هو 0.9142 وقد استخدم النموذج طبقة مخفية واحدة مع خليتين ونسبة خطا قيمتها 0.834.اظهرت النتائج دقة النموذج الرياضي من حيث التقارب بين القيم الحقيقية والقيم المتوقعة في المستقبل وعند استخدام تراكيز الحديد للعامين 2012 و 2013 كانت النتائج ذات تقارب جيد وبمعامل تحديد0.8965.

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (8)


Year
From To Submit

2018 (3)

2017 (1)

2016 (1)

2010 (1)

2009 (1)

More...