Experimental Study of Heat Transfer Coefficients of Shell and Helically Coiled Tube Heat Exchangers
دراسة عملية لمعامل انتقال الحرارة لمبادل حراري مكون من ملف حلزوني واسطوانة

Authors: Sattar Jaber Habeeb Al-Jabair --- Ammar.A.Hussain.A.AL-taee
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 1 Part (A) Engineering Pages: 172-196
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This work presents an experimental study of the heat transfer coefficients of shell and helically coiled tube heat exchangers. Three heat exchangers with different coil pitches were tested for both parallel-flow and counter-flow arrangement. Water is used as working fluids in shell side and tube side. The study is conducted at the hot water mass flow rates ranging between (0.02 - 0.12) kg/s while cold water is kept constant at (0.055 kg/s). The range of inlet temperatures of cold and hot water are (19 - 28 °C), and (50 - 80 °C), respectively. All experiments were performed at the Dean Number for coiled side range of (3803 - 12117). The work is performed to evaluate the influence of the tube diameter, coil pitch, shell-side and tube-side mass flow rate, and inlet temperatures of tube-side over the axial temperature distribution of heat exchanger, effectiveness, modified effectiveness and heat transfer coefficient. The evaluating has been performed for the steady-state . The results indicate that the major effect on the axial temperature distribution of heat exchanger was the mass flow rate ratio (mr). Also the modified effectiveness decreased with increasing mass flow rate ratio. The main influence on the shell-side heat transfer coefficient was coil pitch. Develop an equation to correlate Nusselt Number as function of Reynolds Number, Prandtl Number, Dean Number and helical coil Number.

يقدم هذا العمل دراسة عملية لمعاملات انتقال الحرارة بالحمل القسري لمبادل حراري مكون من اسطوانة (الصدفة) وانبوب ملفوف بشكل حلزوني. تم اختيار ثلاث ملفات وبدرجات حلزون مختلفة (coil pitches) لمقطع الأختبار وللجريان المتوازي والمتعاكس. تم استعمال الماء البارد والحار كسوائل تشغيل من جانب الأسطوانة والملف الحلزوني على التوالي. جرت الدراسة بنسب تدفق للماء الحار تتراوح بين (0.02 - 0.12 kg/s) بينما الماء البارد يبقى ثابت عند .(0.055 kg/s) ان مدى درجات الحرارة لدخول الماء البارد والحارتتراوح بين (19 - 28 °C) و(50 - 80 °C) على التوالي. كل التجارب اديت للأعداد دين تترواح بين .(3803 - 12117) ان الغرض من هذا العمل هو تقييم تأثير كل من قطر الانبوب ، درجة الحلزون (coil pitches) ومعدل التدفق من جانب الملف ومن جانب الصدفة ودرجة حرارة الدخول من جانب الملف على كل من شكل توزيع درجات الحرارة المحورية داخل المبادل، الفعالية،الفعالية المُعَدلّة ومعامل انتقال الحرارة لكل من الجريان المتوازي والمتعاكس. اخذت جميع القراءات للحالة المستقرة فقط. تشير النتائج أن التأثير الرئيسي على شكل توزيع درجات الحرارة المحورية داخل المبادل الحراري كانت نسبة التدفق (mr). تشير النتائج ايضاً ان الفعالية المعدلة تقل مع زيادة نسبة التدفق (mr) . التأثير الرئيسي على معامل انتقال الحرارة الخارجي ( ho ) كان درجة الحلزون (coil pitches) . تطوير معادلات لربط عدد نسلت بعدد رينولد وعدد برانتل وعدد دين.


Article
A Heat Pipe Performance With Heptane as aWorking Fluid
دراسة عملية لأداء أنبوب حراري باستخدام الهيبتان كمائع تشغيلي

Authors: Hussain H.Ahmad --- Raqeeb H. Rajab
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 4 Part (A) Engineering Pages: 646-660
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The heat pipe is a device that efficiently transfers heat from one end to another. It has been widely applied in electronic system cooling and heat spreading applications due to its superior heat conductivity. Many parameters affect the performance of the heat pipe which are worthwise to be investigated. For this reason an experimental rig was designed and constructed to study the important parameters such as the heat load, the working fluid charge and the angle of inclination. Calibrated thermocouples were inserted into the heat pipe outside surface, along and around it, to measure and to show the temperature distribution profile. Heptane was used as a working fluid. Results show that the maximum conductivity obtained was more than one thousand times that of stainless steel solid bar which is the material of the heat pipe container. Also, results of the experimental work show a good agreement with that obtained from theoretical and empirical correlations derived by other researchers especially when the power input is lower than (1000)W where after a dry out condition can be clearly seen.

أنبوب الحرارة جهاز كفوء وفعال جداً لنقل الحرارة من طرف إلى أخر، يستخدم في الوقت الحاضر بصورة واسعة في تبريد المنظومات الإلكترونية وانتشرت تطبيقاته الحرارية بسبب موصليته الفائقة. العديد من العوامل تؤثر على أداء أنبوب الحرارة التي تستحق ذلك الجهد في البحث والتحقق فيها. لهذا السبب تم تصميم الجهاز المختبري وتصنيعه لدراسة تأثير العوامل الحاكمة المختلفة, كالطاقة المجهزة لمبخر الأنبوب الحراري,كمية شحن السائل التشغيلي وزوايا الميل المختلفة. ثبتت متحسسات حرارية معيّرة على طول وحول سطح أنبوب الحرارة لقياس وبيان توزيع درجات الحرارة. أستخدم الهيبتان في هذا البحث كسائل تشغيلي .أظهرت النتائج التجريبية أن الموصلية الحرارية عالية وهي بحدود أكثر من ألف مره بقدر توصيلية قطعه صلدة من الفولاذ التي صنع منها الأنبوب الحراري. كانت النَتائج التجريبية للعمل الحالي متفقة بصوره جيدة مع نتائج معادلات عملية ونظرية لباحثين آخرين، خاصة عند الطاقة المجهزة الاقل من (1000W) بعدها يمكن ملاحظة ظاهرة الجفاف بوضوح .

Keywords

heat pipe --- wick --- filling ratio


Article
Evaluation of the effect of addition of polyester fiber on some mechanical properties of heat cure acrylic resin

Authors: Thikra M. Hachim ذكرى هاشم --- Zainab S. Abullah زينب عبد الله --- Yasamin T. Alausi ياسمين الالوسي
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2013 Volume: 25 Issue: special issue 1 Pages: 23-29
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: This study aimed to evaluate the effect addition of polyester fibers on the some mechanical propertiesof heat cured acrylic resin (implant strength, flexural strength and hardness)Materials and methods: Ninety specimens were used in the study. Thirty specimens were used for impact strengthmeasurements (80mm X 10mm X 4mm) length, width and thickness respectively. The specimens divided into threetest groups (n=10), first group formed from heat cure acrylic resin without fiber reinforcement. Second group wasformed from heat cure acrylic resin was reinforced with 2 mm length polyester fiber and third group was formed fromheat cure acrylic resin reinforced with 4mm length polyester fiber, impact strength measured by impact testingdevice. 30 specimens with (65 mm X 10mm 2.5mm) length, width and thickness respectively were used in 3 groups(n=10) flexural strength test. The flexural strength was measured by using flexural testing device. 30 specimens with(65mm X 10m X 2.5mm) length width and thickness respectively were used for hardness test. The specimens weredivided into 3 group (n=10) as in impact strength and flexural strength.Hardness measured by using (shore D hardness tester TH210).Results: revealed statistically significant increase on impact strength especially on 4mm length when compared tocontrol group. Significant decreases in flexural strength of PMMP. When compared to control group with 4mm lengthfiber reinforcement. Non significant decrease when compared control group with 2mm length fiber reinforcedPMMA. Significant decrease in hardness of PMMA resin after reinforcement with 2mm, 4mm lengths polyester fibers.Conclusions: Strengthening with the polyester fiber decreased the flexural strength and hardness of the resin, butincreased impact strength. Thus when high impact acrylic resins are needed, fiber reinforced resins may be thematerial of choice

الھدف من ھذا البحث لتقییم تاثیر اضافة الیاف البولیستر للاكریلك الحراري على بعض الخواص المیكانیكیة للاكریلك الحراري (مقاومة الصدمة ,قوة الطي,صلادة السطح).استخدم في البحث 90 نموذج وقد قسمت الى 30 نموذج لكل خاصیة , 30 نموذج لقیاس قوة الصدمة بقیاسات ( 80 ملم* 10 ملم* 4ملم) الطول , العرض,السمك بالتتالي النماذج قسمتالى ثلاثة مجموعات (العدد= 10 ) للاختبار المجموعة الاولى شكلت من الاكریلك الحراري بدون اضافة الالیاف ,المجموعة الثانیة شكلت باضافة الالیاف بطول 2ملم,المجموعة الثالثةشكلت باضافة الالیاف بطول 4ملم. مقاومة الصدمة قیست بواسطة جھاز قیاس الصدمة .30 نموذج استخدمت لقیاس قوة الطي بقیاسات ( 65 ملم* 10 ملم* 2,5 ملم)الطول ,العرض,السمك بالتتالي ,قسمت الى ثلاثة مجامیع( العدد= 10 ) لكل مجموعة وتم قیاس قوة الطي بجھازقیاس قوة الطي. 30 نموذج استخدمت لقیاس صلادة السطح بنفس القیاسات المستخدمة لقیاس قوة الطي .عكست النتائج زیادة ملحوظة في مقاومة الصدمة وخاصة بعد اضافة الالیف بطول 4 ملم ونقصان ملحوظ في قوة الطي بعد اضافة الالیف بطول 4ملم مع نقصان غیر ملحوظ بعداضافة الالیاف بطول ال 2ملم. نقصان غیر ملحوظ لكلا الطولین على صلادة السطح. ھذه الدراسة استنتجت ان اضافة الیاف البولستر تقلل من قوة الطي والصلادة ولكن تزید من مقاومةالصدمة ولذلك عندما نرید ان نستخدم الاكریلك الحراري ذو المقاومة العالیة للصدمة نستخدم الاكریلك الحراري المدعم بالیاف البولیستر


Article
EVALUATION OF TELLOL AL-KIEND CLAY IN MOSUL CITY FOR THE PRODUCTION OF LIGHT WEIGHT AGGREGATES

Authors: Doaa M. Hammed --- Mayada S. Joodi --- Abdul Wahab AR. Al-Ajeel
Journal: Iraqi Bulletin of Geology and Mining مجلة الجيولوجيا والتعدين العراقية ISSN: 18114539 Year: 2013 Volume: 9 Issue: 2 Pages: 151-160
Publisher: Ministry of Industry and Minerals وزارة الصناعة والمعادن

Loading...
Loading...
Abstract

In this research a representative sample from Tellol Al-Kiend clay deposit (Injana Formation), Naenava Governorate, Iraq, was evaluated for lightweight aggregates preparation. Two methods of heat treatment were carried out. Iso-thermal treatment conducted at (1180 – 1200) °C range, for aggregates made from clay only, using different socking time. Whiles, rapid (or flush) firing, were carried out at 1200 °C, for aggregates made from clay with different types and amounts of additives (dolomite, waste engine oil, and straw). The iso-thermal tests reveal that bloating can occurs at 1180 °C only for 45 minutes holding time. The aggregates obtained, have a specific gravity of about 1.38 and 0.8% water absorption. In rapid firing, it was found that, the bloating of the clay can be significantly improved by the addition of dolomite. The results obtained indicated that aggregates having 1.35 specific gravity with about 1% water absorption value could be produced from aggregates made of clay and 5 wt.% dolomite. The firing time has been about 5 minutes. Thereupon, it can be suggested that, Tellol Al-Kiend clay can be used for the production of lightweight aggregates by rapid firing. Concrete made from these lightweight aggregates shows a compressive strength (28 days) of about 173 kg/cm2, which can be designated as structural and insulating concrete.

جرى في هذا البحث تقييم نموذج ممثل لترسبات أطيان تلول الكند (تكوين إنجانة) في محافظة نينوى لإنتاج الركام الخفيف، وجربت طريقتان للمعالجة الحرارية. جرى في الطريقة ألأولى معالجة الركام المحضر من الطين فقط في درجات حرارة تتراوح مابين (1180 ـ 1200) °م وزمن استبقاء مختلف. أما الركام المحضر من الطين مع كميات وأنواع مختلفة من المواد المضافة (دولومايت، مخلفات زيت المحركات والقش) فقد تم معالجتها بالحرق السريع (أو المفاجئ) عند درجة حرارة 1200 °م مع زمن استبقاء 2 أو 3 دقائق. بينت نتائج حرق الركام المحضر من الأطيان فقط بأن الانتفاخ يمكن أن يحصل فقط عند حرارة 1180 °م وبزمن استبقاء 45 دقيقة، وإن الركام الناتج من هذه العملية أعطى كثافة نوعية بحدود 1.38 ونسبة امتصاص للماء 0.8%. ولكن وجد أنه باستخدام الحرق المفاجئ فإن انتفاخ ركام الطين يتحسن بشكل ملحوظ عند إضافة الدولومايت وبينت النتائج المستحصلة من هذه العملية إمكانية إنتاج ركام يمتلك كثافة نوعية بحدود 1.35 ونسبة امتصاص للماء 1% عند إضافة 5% وزناً من الدولومايت للطين وإن الزمن اللازم للحرق هو بحدود 5 دقائق. وعليه يمكن استخدام أطيان تلول الكند في إنتاج الركام الخفيف بإتباع الحرق السريع. كما بينت نتائج فحص الكونكريت المحضر من الركام الخفيف بأن مقاومة الانضغاط بعد 28 يوم بحدود 173 كغم/ سم2 والذي يمكن أن يستخدم في تحضير الخرسانة الإنشائية العازلة.


Article
Twist parameter Influence on Heat Transfer Coefficient Augmentation for a square Twisted Tube
تأثير عامل الالتواء على زيادة معامل انتقال الحرارة لأنبوب ملتوي مربع المقطع

Author: Abdulkareem Abbas KhudhairAl-Musawi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 9 Part (A) Engineering Pages: 1802-1816
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Heat transfer augmentation due to twisting parameter was investigated in atwisted tube of square cross sectional area. Twisting parameter is defined as the ratio of the length of the tube where it completed twisting of360 degrees to its hydraulic diameter.Four twist parameters were chosen;5, 10, 25 and 50, and a comparison is made with a straight untwisted duct.Two sets of Reynolds numbers were considered for laminar and transient flow. The laminar flow is performed at Re=500,1000,1500 and 2000. While for transient flow the range of Reynolds number are Re=5000,6000,7000,8000 and 9000.Theinfluence of twist parameter on convective heat transfer coefficient in laminar and transient flow was investigated.Numerical simulations were performed for three-dimensional, steady state incompressible flow in body-fitted coordinate using finite volume method and standard k-ε turbulence model. For the heat transfer problem the uniform wall temperature (UWT) boundary condition at tube wall is considered.It was observed that the heat transfer coefficient increases with decreasing twist parameter. This is interpreted to the nature of span wise swirling flow generated. The swirling increases cross flow velocity vectors as it becomes far from tube center towards walls. At tube wall the thickness of boundary layer becomes thinner as near wall velocity become larger which leads to a boundary layer of good thermal characteristics. Also swirling increases internal mixing process which enhances internal thermal equilibrium. The heat transfer coefficient also increases as Reynolds number increased as velocity components are increased

تمت دراسة زيادة انتقال الحرارة بسبب عامل الالتواء لأنبوب ملتوي ذو مقطع مربع. يعرف عامل الالتواء بانه النسبة بين طول الانبوب الذي يلتوي بزاوية قدرها 360 درجة الى قطره الهيدروليكي.وقد تم اختيار اربعة معاملات التواء و هي 5، 10، 25، 50 واجريت المقارنة مع انبوب غير ملتوي.تمت دراسة مجموعتان من اعدادرينولدز للجريان الطباقي و الانتقالي. حيث تم اختيار اعدادرينولدز 500، 1000، 1500، 2000 للجريان الطباقي. اما بالنسبة للجريان الانتقالي فقد تم اختيار اعدادرينولدز 5000، 6000، 7000، 8000 و 9000. لقد تمت دراسة تأثير عامل الالتواء على معامل انتقال الحرارة بالحمل في الجريان الطباقي و الانتقالي.تم اجراء المحاكات العددية لجريان ثلاثي الابعاد، مستقر، غير انضغاطي بالإحداثيات المطابقة للجسم بطريقة الحجم المحدد باستخدام نموذج الاضطراب k-ϵ القياسي. و تم افتراض انتظام درجة حرارة الجدران كشرط حدي عند دراسة انتقال الحرارة. لوحظ ان معامل انتقال الحرارة يزداد مع ازدياد عامل الاتواء. وهذا ينسب الى طبيعة الجريان الدوامي المستعرض المتولد. حيث يزيد التدويم متجهات سرعة الجريان العرضية كلما ابتعدت عن مركز الانبوب باتجاه الجدران. ان معامل انتقال الحرارة يزداد مع ازدياد عامل الاتواء. وهذا ينسب الى طبيعة الجريان الدوامي المستعرض المتولد. حيث يزيد التدويم متجهات سرعة الجريان العرضية كلما ابتعدت عن مركز الانبوب باتجاه الجدران. عند الجدران تصبح سماكة الطبقة المتاخمة انحف كلما اصبحت السرعة قرب الجدار اعلى وهذا يحسن الخواص الحرارية للطبقة المتاخمة. كذلك التدويم يزيد من الخلط الداخلي الذي بدوره يعزز الاتزان الحراري. كذلك يزداد معامل انتقال الحرارة بزيادة رقم رينولدز كنتيجة لازدياد مركبات السرعة.


Article
Surface properties of heat treated with different durations of titanium alloy dental implants

Author: Shorouq M. Abass
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2013 Volume: 25 Issue: 3 Pages: 49-56
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: The surface properties of the titanium alloy plays a significant role in the bond of the dental implant withliving bone and modification of the implant surface could enhance osseointegration. This study was aimed toinvestigate the effect of different durations of heat treatment on the surface properties of titanium alloy for dentalimplants.Materials and methods: Twenty disks of (Ti-6Al-4V) alloy were prepared. The sample was divided into four test groupsto study the effect of different duration of heat treatment to the surface topography; surface chemistry, titaniumoxide layer thickness, blood contact angle, & blood drop diameter of titanium alloy samples were investigated toevaluate the effect of different durations of heat treatment at a temperature of 750°C.Results: The surface topography, surface chemistry, titanium oxide layer thickness, blood contact angle, & blood dropdiameter of titanium alloy samples improved highly significantly as the duration of heat treatment increased.Conclusions: The heat treatment of 750°C for 90 minutes showed the highest improvement in the surface propertieswhich in turn will lead to enhancement in the osseointegration of the dental implant


Article
Effect of the Axial Heat Conduction in Parallel Flow Rectangular Microchannel Heat Exchanger

Author: Hayder Mohammed Hasan
Journal: University of Thi-Qar Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 26645564/26645572 Year: 2013 Volume: 4 Issue: 1 Pages: 113-137
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

The axial heat conduction in parallel flow microchannel heat exchanger with rectangular ducts was numerically investigated, for laminar, 3-D, incompressible, and steady state flow of water. The governing equations, continuity, Navier-Stokes equations (momentum equations), and the energy equations for the hot and cold fluids were solved by using SIMPLE algorithm with finite volume method and FORTRAN code to obtain the temperature distribution for the two fluids and the separating wall between them. The results play an important role of the axial heat conduction on the effectiveness in parallel flow microchannel heat exchanger and the factors affecting the axial heat conduction are; Reynolds number Re, thermal conductivity ratio , aspect ratio α and channel volume. Increasing of Re, , α and channel volume each separately leads to increase the axial heat conduction and vice versa.

عدديا تمت دراسة تأثير التوصيل الحراري المحوري في مبادل حراري مايكروي ذي قنوات مستطيلة الشكل لجريان متوازي طباقي ثلاثي الأبعاد للماء وفي حالة الاستقرار ولا انضغاطي. تم حل المعادلات الحاكمة للجريان وهي معادلة الاستمرارية continuity) (equation ومعادلات الزخم (momentum equations) و معادلة الطاقة ((energy equations باستخدام طريقة ((SIMPLE method وقد تم تحويل المعادلات الحاكمة إلى الشكل العددي باستخدام طريقة الحجوم المحددة (finite-volume method) وباستخدام لغة فورتران (FORTRAN). بهذه الطريقة تم إيجاد التوزيع لدرجتي حرارة المائعين والجدار الذي يفصل بينهما. من خلال ملاحظة النتائج المستحصلة من الحل العددي, تبين بأن هنالك تأثير مهم للتوصيل الحراري المحوري على الفعالية في المبادل المايكروي كما إن هنالك مجموعة من العوامل التي تؤثر عليه وهي, عدد رينولدز(Reynolds number Re) ونسبة الموصلية الحرارية (thermal conductivity ratio Kr ) والنسبة الباعية (aspect ratio α) وحجم القنوات. عند زيادة Re و Krوα وحجم القنوات كل على حدة يزداد التوصيل الحراري المحوري, والعكس صحيح.


Article
NUMERICAL INVESTIGATION OF HEAT TRANSFER THROUGH POROUS MEDIA

Author: Rafel Hekmat Hameed
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2013 Volume: 13 Issue: 3 Pages: 551-564
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Heat transfer mechanism model was predicted in order to simulate the temperature distribution of the two phases (glass-air) through the macrostructure of porous media sample in depth 20 mm at local equilibrium. It has been heating the sample from left side through x-axis with different values of heat flux. The model contain two stages: firstly, predict the temperature distribution in solid phase by transient 2-dimensional conduction heat equation; secondly, switching was happened in the program to simulate the temperature distribution in fluid phase of sample by energy balance. It has been found the temperature distribution in glass and air through the first two layers of series configuration of the sample. It showed very small values of heat transfer coefficient between these layers. That means high insulation property was observed from this structure of porous media sample. Due to the heating process, it has been noted the air inside the first layer was accelerated a very little bit as marks the onset of convection. This is due to the pressure gradient was produced between the outside and inside layers of sample through heating process with time. Darcy law was used to calculate this air velocity. Heat transfer coefficient inside porous media, effective Nusslet number and Nusslet number of fluid phase were calculated.

تم عمل أنموذج رياضي لتوضيح توزيع درجات الحرارة خلال البنية الداخلية لنموذج مادة مسامية مكونة من الزجاج والهواء وبسمك 20 ملم بافتراض حالة الاتزان بين الطورين (زجاج-هواء). تم تسخين نموذج المادة المسامية من الجهة اليسرى للمحور السيني لاتجاه النموذج المسامي بقيم مختلفة من الفيض الحراري. تمت النمذجة على مرحلتين المرحلة الأولى هو حساب حساب درجة الحرارة في الطور الصلب (الزجاج) بواسطة استخدام معادلة التوصيل الحراري ثنائية البعد بتغير الزمن والمرحلة الثانية حساب التوزيع الحراري لطور المائع (الهواء) باستخدام معادلة الطاقة بافتراض اتزان الطاقة بين الطورين.تم إيجاد التوزيع الحراري لدرجات الطور الصلب (الزجاج) وطور المائع (الهواء) خلال الطبقتين الأوليتين للبنية الداخلية لتركيب المادة المسامية، وقد اتضح إن معامل انتقال الحرارة قليل جدا بين طبقة الزجاج وطبقة الهواء وهذا يعني ان المادة المسامية لديها قابلية على العزل الحراري.بسبب عملية التسخين لوحظ ان الهواء الموجود داخل طبقات البنية التركيبية للنموذج المسامي وخاصة في الطبقة الأولى يتحرك بسرعة بطيئة جدا نتيجة حدوث عملية انتقال حرارة بالحمل اللحظي وهذا يرجع بسبب حدوث فرق بقيم الضغط بين سطح الطبقة الخارجية المسخنة للنموذج المسامي والطبقة الداخلية التي تحتوي على الهواء خلال عملية التسخين بتغير الزمن، استخدم قانون دارسي لحساب قيمة سرعة الهواء اعتمادا على قيم تغير الضغط. تم حساب معامل انتقال الحرارة ورقم نسلت المؤثر للمادة المتسامية ولطور المائع (الهواء) في المادة المتسامية أيضا.


Article
Numerical Investigation of Heat Transfer in Parallel Rectangular Microchannel Heat Exchanger
دراسة عددية لإنتقال الحرارة في مبادل حراري مايكروي متوازي ذي قنوات مستطيلة الشكل

Author: Hayder Mohammed Hasan حيدر محمد حسن
Journal: University of Thi-Qar Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 26645564/26645572 Year: 2013 Volume: 4 Issue: 3 Pages: 1-29
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

The axial heat conduction in parallel flow microchannel heat exchanger with rectangular ducts was numerically investigated, for laminar, 3-D, incompressible, and steady state flow of water. The governing equations, continuity, Navier-Stokes equations (momentum equations), and the energy equations for the hot and cold fluids were solved by using SIMPLE algorithm with finite volume method and FORTRAN code to obtain the temperature distribution for the two fluids and the separating wall between them. The results play an important role of the axial heat conduction on the effectiveness in parallel flow microchannel heat exchanger and the factors affecting the axial heat conduction are; Reynolds number Re, thermal conductivity ratio , aspect ratio α and channel volume. Increasing of Re, , α and channel volume each separately leads to increase the axial heat conduction and vice versa.

عدديا تمت دراسة تأثير التوصيل الحراري المحوري في مبادل حراري مايكروي ذي قنوات مستطيلة الشكل لجريان متوازي طباقي ثلاثي الأبعاد للماء وفي حالة الاستقرار ولا انضغاطي. تم حل المعادلات الحاكمة للجريان وهي معادلة الاستمرارية continuity) (equation ومعادلات الزخم (momentum equations) و معادلة الطاقة ((energy equations باستخدام طريقة ((SIMPLE method وقد تم تحويل المعادلات الحاكمة إلى الشكل العددي باستخدام طريقة الحجوم المحددة (finite-volume method) وباستخدام لغة فورتران (FORTRAN). بهذه الطريقة تم إيجاد التوزيع لدرجتي حرارة المائعين والجدار الذي يفصل بينهما. من خلال ملاحظة النتائج المستحصلة من الحل العددي, تبين بأن هنالك تأثير مهم للتوصيل الحراري المحوري على الفعالية في المبادل المايكروي كما إن هنالك مجموعة من العوامل التي تؤثر عليه وهي, عدد رينولدز(Reynolds number Re) ونسبة الموصلية الحرارية (thermal conductivity ratio Kr ) والنسبة الباعية (aspect ratio α) وحجم القنوات. عند زيادة Re و Krوα وحجم القنوات كل على حدة يزداد التوصيل الحراري المحوري, والعكس صحيح.


Article
Effect of Heat Treatment on the Optical Properties of ZnO Thin Films Prepared by Chemical Spray Method

Author: G.Y. Nasser
Journal: Iraqi Journal of Applied Physics المجلة العراقية للفيزياء التطبيقية ISSN: 18132065 23091673 Year: 2013 Volume: 9 Issue: 1 Pages: 23-26
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

In this research, thin films of ZnO of thickness 5200ű30 prepared using chemical spray method. The films deposited on Crown glass substrates Optical studies show that in these films the electronic transition is of the direct transition type. The optical energy gap for the films of as deposited and for those heat treated for an hour at different temperatures is estimated to be in the range 3.05-3.2 eV. Results analysis exhibits the dependence of optical energy gap on the temperature of heat treatment.

Listing 1 - 10 of 39 << page
of 4
>>
Sort by
Narrow your search

Resource type

article (39)


Language

English (39)


Year
From To Submit

2013 (39)