research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Mixed Convection from Electronic Equipment Component at Different Position at Enclosure by Primitive Variables Method

Authors: Sattar J. Habeeb --- khalid A. Ismael --- Jalal M. Jalil
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2006 Volume: 12 Issue: 1 Pages: 37-52
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A numerical study of mixed convection cooling of heat dissipating electronic component, located in a rectangular enclosure, and cooled by an external through flow of air is carried out. A conjugate problem is solved by primitive variables method, describing the flow and thermal fields in air. The interaction between the components is of interest here, depending on their relative placement in the enclosure, and different configuration are considered. For Re=100 laminar, steady flow is predicted for up to Gr/Re2 =25 according to head source location in the enclosure. The mixed convection regime, where the buoyancy effects are comparable to the forced flow, occurs at values of Gr/Re2 between 0.01 and 25 . the results are of values in search for suitable placement of electronic components in an enclosed region for an effective heat removal. In general, it appears that the location of the source on the left vertical wall is the most favorable in terms of cooling. Laminar results are predicted up for up to Gr= 2.5 *105 for all configurations studied.

تم دراسة تشتيت الحرارة الناتجة من أداء الأجهزة الإلكترونية الموضوعة داخل تجويف مستطيل الشكل ، من اجل تبريدها بواسطة هواء خارجي يسلط عليها، مما يؤدي الى الاستفادة من انتقال الحرارة بالحمل المختلط الناتج عن ذلك. حيث تمت الدراسة باستخدام الحل العددي التقريبي لمعادلات الكتلة والزخم والطاقة عن طريق وصف الحركة الديناميكية والحرارية للمائع. أن عملية التداخل الناتجة من وجود اكثر من مصدر حراري داخل الحيز المدروس هي المسألة المهمة هنا، اعتمادا على موقع المصادر الحرارية نسبتا بعضها إلى البعض الأخر داخل التجويف المستطيل الشكل. كما تم أخذ تغير موقع المصادر الحرارية داخل الحيز بنظر الاعتبار،بالنسبة Re=100 ، جريان طباقي، مستقر، إلى رقم ريشاردسون Gr/Re2 بحدود 25 طبقا إلى موقع المصدر الحراري داخل الحيز. في منطقة الحمل المخلط فأن تأثير قوى الطفو قورنت نسبة إلى حالة الحمل القسري والتي تتكون لرقم ريشاردسون بين 25-0.01 . النتائج كانت لقيم البحث عن افضل موقع للمصدر الحراري داخل الحيز عن طريق تأثير إزالة الحرارة. بصورة عامة أتضح أن وضع المصدر الحراري على الجدار العلوي الأيسر للحيز المدروس يعطي أفضل أداة لعملية التبريد وإزالة الحرارة. كما كانت قيم رقم كراشوف بحدود Gr=2.5*105 لكل الحالات المدروسة.


Article
Numerical and Experimental Study on Heat Transfer Enhancement by Vortex Generation
دراسة عددية وتجريبية لتعزيز انتقال الحرارة بواسطة التوليد الدوامي

Authors: Sabah T. Ahmed صباح احمد --- Khalid A. Ismeal خالد اسماعيل --- Jalal M. Jalil جلال محمد جليل
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2006 Volume: 10 Issue: 1 Pages: 107-129
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Numerical and experimental study was carried out on heat transfer enhancement using a slender delta wing vortex generator to generate longitudinal vortices in a rectangular duct. Numerically, laminar with constant wall temperature was considered. Effect of angle of attack of the wing (from 0.0 to 56.5 degree) on the Spain-wise average Nusselt number and the span wise average skin friction coefficient were investigated. Numerical results demonstrate similar behavior to the published results of other investigators.
Experimentally, effect of angle of attack (from 0.0 to 56.5 degree) of the vortex
generator, wing aspect ratio of the vortex generator (from 0.5 to 2.0) and wing width to duct
width (from 0.25 to 0.5) on the heat transfer process for laminar flow (Re = 750 to 2700)
and turbulent flow (Re = 4100 to 7950) were investigated. Both numerical and experimental
results show the enhancement of heat transfer but experimental results show higher values
of Nusselt number compared with the numerical results.

تم في هذا البحث إجراء دراسة عددية و عملية حول تحسين انتقال الحرارة باستخدام مولد دوامات نحيف على شكل جنيح مثلث لتوليد دوامات طولية في مجرى مستطيل المقطع. عدديا استخدم مجرى طباقي مع جدران درجة حرارتها ثابتة. وقد تم دراسة تأثير زاوية الهجوم لمولد الدوامات من صفر إلى 56.5 إلى المتوسط العرضي لرقم نسلت وكذلك المتوسط العرضي لمعامل احتكاك السطح. وقد أوضحت الدراسة العددية تصرف مشابه لما نشره الباحثون الآخرون. عمليا تم دراسة تأثير زاوية الهجوم من صفر إلى 56.5 درجة ونسبة عرض الجنيح إلى عرض المجرى من 0.25 إلى 0.5 لجريان الطباقي (يتراوح عدد رينولدز بين 750 إلى 2700) ولجريان مضطرب (يتراوح عدد رينولدز بين 4100 و 7950). وقد أظهرت كلا النتائج العملية و النظرية زيادة في انتقال الحرارة ولكن النتائج العملية أظهرت قيم لنسلت أعلى من النتائج العددية.

Keywords

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (1)

English (1)


Year
From To Submit

2006 (2)