research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Water Pressure Equalization in Pipe Network Case Study : Al- Karada Area in Baghdad

Authors: Hameed Mirza Mita´b --- Awatif Soaded Abdul-Hameed --- Rafa Hashim Al-Suhaily
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2006 Volume: 12 Issue: 2 Pages: 277-293
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In order to make a balance between the increasing of potable water demand and the available quantity, a pipe network should be managed in an optimal hydraulic operation state. The optimal operation of a water supply network leads to minimize the effect of the variance in pressure between the available and minimum required pressure head. It simulates the hydraulic model and puts the optimized project with the constraints (minimum design head=20 m, and the available commercial pipe diameter, (1600> D> 250 mm). The objective function is to minimize the cost for the suggested hydraulic solution to a minimum value. Pressure uniformity coefficient (UC), Standard deviation (σ) and coefficient of variance (Cv) are used to show that the pressure head at the nodes of the network is uniformly distributed. The optimal design of the case study (R9 water supply network) has an actual cost of 561,169,310 ID and the uniformity indices of UC=99.565, σ=3.6508 and Cv=0.1543 while the existing design has cost of 856,617,170 ID with the uniformity indices of UC=97.909, σ=3.5977 and Cv=0.7906. Hence there is a benefit of 34.5% in the cost of the optimal design used in this study, with high uniformity coefficient. The effect of Hazen-William coefficient (C) on total cost showed an inversely linear effect. For the value of C=130, the actual cost was 600,898,300 ID, i.e., the penalty cost approached to zero and has no effect on the total cost.

لغرض عمل موازنة بين ازدياد الاحتياج والكمية المتوفرة للمتطلب المائي وجب إدارة شبكة المياه بالشكل الأمثل للأداء الهيدروليكي.إن أفضل و أمثل ادارة هيدروليكية لشبكات المياه تقود إلى تقليل الفارق بين الضغط المتوفر من قبل الشبكة واقل ضغط مطلوب بالشبكة إلى اقل حد ممكن. عمل محاكاة إلى النموذج الهيدروليكي ووضع المشروع الأمثل مع المحددات وهي ( اقل ضغط تصميمي هو 20 m و الأقطار التجارية المتوفرة (D<1600,D>250 mm). إن دالة الهدف تعمل على جعل كلفة الحل المقترح إلى اقل قيمة ممكنة. معامل انتظام الضغظ ,UC الانحراف المعياري σ والتباين Cv تستخدم كمؤشر إلى أن الضغط بالعقد للحل الأمثل للمشكلة يمتلك انتظاماً توزيعياً. أفضل تصميم لشبكة الدراسة الحقلية (شبكة ماء الكرادة R9) يمتلك كلفة هي 561,169,310 ID ومعامل الانتظام UC=99.565 , الانحراف المعياري σ=3.6508 والتباينCv=0.1543 , بينما التصميم الحالي للشبكة بكلفة 856,617,170 ID ومعامل الانتظام UC=97.909 , الانحراف المعياري σ=3.5977 والتباينCv=0.7906 و بذلك التصميم الأمثل في هذه الدراسة اقل كلفة بنسبة 34.5% من التصميم الحالي وكل معاملات الانتظام تدل على إن الشبكة ذات توازن وانتظام عالي. إن تأثير معامل الاحتكاك Hazen-William على الكلفة الكلية يظهر تأثيراً عكسياً, ولقيمة C=130 تكون الكلفة الكلية وهي 600,898,300 ID. بذلك تكون ال((Penalty cost صفراً ولايوجد لها تأثيراً على الكلفة الكلية.


Article
Use Of Bentonite Clay As A Coagulant Or A Coagulant Aid With Ferrous Sulfate For Synthetic Turbidity Removal
استخدام طين البنتونايت كمخثر أو كمساعد للتخثير مع كبريتات الحديدوز في إزالة العكورة المصطنعة من الماء

Authors: Mohammad S. Hassan محمد سليمان حسن --- Musa’b A. Al- Tamir مصعب عبدالجبار التمر
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2006 Volume: 14 Issue: 4 Pages: 46-58
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractIn this study the bentonite clay has been used as a coagulant and coagulant aid with ferrous sulfate in turbidity removal for different initial synthetic turbidity of Tigris River samples of (10- 500) ntu, The study revealed the efficiency of using bentonite clay as a coagulant alone in removing turbidity with a dose not more than 30 mg/l, Also the study reveled the improvement of ferrous sulfate efficiency for removing water turbidity when bentonite clay used with it in a dose of 7.5 mg/l of bentonite and 5 mg/l of ferrous sulfate. The regression analysis showed that the most important variables affecting on turbidity removal were initial turbidity followed by settling time and bentonite clay dose then finally ferrous sulfate dose. Key Words: Ferrous Sulfate, Iron Salts, Bentonite Clay, Coagulation, flocculation, Coagulant aids, Turbidity removal, Water Supply

الملخصتم خلال هذه الدراسة استخدام طين البنتونايت كمخثر لوحده وكمساعد مخثر مع كبريتات الحديدوز في إزالة مستويات مختلفة من العكورة الابتدائية المصطنعة لنماذج من ماء نهر دجلة تتراوح بين (10 –500) وحدة عكورة، أثبتت الدراسة أن طين البنتونايت يعمل بكفاءة عند استخدامه كمخثر لوحده وبجرع لاتزيد عن (30) ملغملتر لمستويات العكورة ضمن الدراسة، كذلك أظهرت الدراسة تحسن قابلية كبريتات الحديدوز في إزالة العكورة عند استخدام طين البنتونايت معه وبجرع مقدارها (5) ملغملتر و(5.7) ملغملتر لكل من البنتونايت وكبريتات الحديدوز على الترتيب، وكانت فاعلية طين البنتونايت عند استخدامه مع كبريتات الحديدوز أكثر عند المستويات الواطئة من العكورة الابتدائية وعند الجرع الواطئة من كبريتات الحديدوز. كما بين التحليل الإحصائي أن العوامل الأكثر تأثيراً على العكورة المتبقية هي على الترتيب: العكورة الابتدائية، زمن الترسيب، جرعة طين البنتونايت وأخيراً جرعة كبريتات الحديدوز وبمعامل إرتباط مقداره (70%).الكلمات الدالة: كبريتات الحديدوز، أملاح الحديد، طين البنتونايت، التخثير، التلبيد، مساعدات التخثير، إزالة العكورة، إسالة الماء.


Article
INVASION OF ZEBRA MUSSEL DREISSENA POLYMORPHA( PALLAS,1771) INTO THE COOLING SYSTEM WATER SUPPLY OF AL-MUSAYAB THERMAL POWER PLANT / IRAQ
اجتياح المحار المخطط Dreissena polymorpha(Pallas, 1771) في ماء تجهيز منظومة التبريد لمحطة كهرباء المسيب الحرارية / عراق

Loading...
Loading...
Abstract

Zebra mussels Dreissena polymorpha are tiny bivalve mollusca , invade water supply of cooling system unit in Al-Musayab power plant, 60 km south-west Baghdad and grow to dense clusters. Its ability to rapidly colonize intake structures, such as pipes and screens causing reduction in water pumping capabilities .Some biological aspects of zebra mussel Dreissena polymorpha have been studied and some physical & chemical parameters were examined as alimenting factors for the species Samples collecting was done monthly from two sites within the water system , the first was the traveling band screen (TBS ) and the other site was small canal collecting excess water passing from TBS .Biological studies revealed that the samples collected from the canal includes five size groups with average length of 5.7 ; 11.3 ; 16.7 ; 21.9 & 27.3 mm. In TBS , the individuals found all over the year with highest number of 135 individuals recorded in August . Individuals of a length of 11.3 & 16.7mm were the dominant.In general, from total number of 799 individuals collected from TBS, 388 individuals were of size of 11.3mm and 239 individual were of size 16.7mm while no large specimens of large size group of 27.3mm were recorded in TBS.To study the settlement rate of larvae, several concreat tiles of (25X25cm) were suspended at depths of 2,4& 6 m. in the sedimentation pond (12m depth). The number of juveniles were counted monthly . The result showed that there were two peaks of settlement , one in June and the other in September and October .Depth of 6m was the most suitable for settlement.The average length of settled juveniles ranged between 3.5-6.1mm. Water temperature in the site ranged between 11-32o C , Dissolved oxygen was 4.8-8.3ml/L . The highest value of turbidity was 49NTU.Ca++ was 68-136mg/l and Mg++ was 34-72mg/l

المحار المخطط Dreissena polymorpha هو نوع صغير من النواعم ذات المصراعين , اجتاح ماء تجهيز منظومة التبريد التابعة لمحطة كهرباء المسيب الحرارية /60 كم جنوب غرب بغداد . لهذه الاحياء القدرة على التكاثر السريع مكونة تجمعات كبيرة تلتصق افرادها بعضها ببعض وتتجمع داخل انابيب الماء وعلى مشبكات الترشيح فتقلل من كفائتها في الترشيح اضافة الى انخفاض سرعة جريان الماء في الانابيب . درست بعض الجوانب الحياتية لهذا المحار , اضافة لبعض العوامل الكيمياوية والفيزياوية المحدده لنموه . جمعت عينات النوع شهرياً من موقعينن ضمن منظومة تجهيز الماء في هذه المحطة , الموقع الاول , الغربال الثالث او غربال الاحزمة المتحركة(TBS).اما الموقع الثاني فهو قناة لجمع الماء الزائد المتساقط من الغربال الثالث .اشارت نتائج الدراسة الحياتية الى ان العينات التي تم جمعها من القناة تضم خمس فئات حجمية بمعدل اطوال 5.7 و 11.3 و 16.7 و 21.9 و 27.3 ملم اما في الغربال الثالث فقد لوحظ تواجد الافراد على مدار السنة وسجل اعلى عدد للافراد 135 فرد خلال شهر اب , وكانت الافراد من فئة 11.3 و 16.7 ملم هي السائدة , وعموماً فان من مجموع 799 فرد تم جمعها من الغربال الثالث , 388 فرد من الفئة الحجمية 11.3 ملم و239 فرد من الفئة الحجمية 16.7 ملم , بينما لم تسجل الفئة الحجمية الكبيرة (27.3 ملم ) أي تواجد لها في الغربال الثالث . ولغرض دراسة كفاءة رسوخ اليرقات علقت عدد من البلاطات الكونكريتية (25 x25) ملم على اعماق 2 و4 و 6 متر داخل احواض الترسيب ( عمق 12 متر ) وسجل عدد اليرقات المترسخة على البلاطات شهرياً .اشارت النتائج الى وجود قمتين للرسوخ , واحدة في شهر حزيران والثانية في شهر ايلول وتشرين اول كما سجلت البلاطات في العمق 6 متر اعلى معدل لرسوخ اليرقات . تراوح معدل طول اليافعات الراسخة على البلطات خلال فترة الدراسة بين 3.5 – 6.1 ملم .تراوحت درجة حرارة الماء خلال الدراسة بين 11-32 0 م وقيم الاوكسجين بين 4.8 – 8 مل / لتر . وسجل اعلى قيمة للعكورة 49 وحدة عكورة . اما قيم تركيز الكلسيوم فتراوحت بين 86 – 136 ملغم /لتر , والمغنسيوم 34 – 72 ملغم / لتر .


Article
Evaluation of Drinking Water Quality in Group of Schools at Mosul City
التقييم النوعي لمياه الشرب في بعض مدارس مدينة الموصل

Authors: Musa’b A. Al-Tamir مصعب عبد الجبار التمر --- Mazin nazzar Al-Sanjari مازن نزار السنجري
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2006 Volume: 14 Issue: 3 Pages: 53-62
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

ABSTRACTThe monitoring of water quality produced for drinking is one of the mostimportant study in order to evaluate the suitability of water for humanconsumption also to evaluate efficiencies of treatment water plants and waterdistribution system especially in the present situation of the country. This studyfocusing on the quality of drinking water used by student in some schools atMosul city. Where 17 schools had been selected through the city. mainchemical and physical analysis had been done on these samples in addition tothe total bacteria count, the study revealed that the water quality of the studiedschools was within the standards of drinking water. A negative result wereappeared for total bacteria count in one sample, only seem to be an indicationof a new case of pollution with bacteria, this might be due to the water supplynetwork, fortunately the result were within the Iraqi standards for drinkingwater.Key words: Water quality, Drinking water, Schools, Iraq, Mosul, Blockade,Water Supply.2005/

الملخصتمثل مراقبة نوعية الماء المنتج للشرب من الدراسات المهمة لتقييم صلاحية الماء للاستهلاك البشريوكفاءة عمليات المعاملة وشبكة التوزيع؛ خاصة في الظروف التي يمر بها القطر في الوقت الحاضر،تم في هذه الدراسة إلقاء الضوء على نوعية ماء شرب الطلبة في بعض مدارس مدينة الموصلبانتقاء 17 مدرسة موزعة ضمن المدينة وأجريت الفحوص الفيزيائية والكيميائية التقليدية على نماذجمن الماء مأخوذة من هذه المدارس فض ً لا عن فحص العدد الكلي للبكتريا؛ أظهرت الدراسة أن الحالةالنوعية لماء الشرب للمدارس المشمولة كانت ضمن حدود مواصفات مياه الشرب، غير أنه ظهرتنتيجة سلبية لعدد البكتريا الكلي في نموذج واحد فقط ليدل على التلوث الحديث بالبكتريا الذي ربمايكون سببه الشبكة الناقلة للماء ولحسن الحظ كان هذا العدد ضمن حدود المواصفة العراقية لمياهالشرب.الكلمات الدالة: نوعية الماء، مياه الشرب، المدارس، العراق، الموصل، الحصار، محطات الإسالة.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

Arabic (2)

English (2)


Year
From To Submit

2006 (4)