research centers


Search results: Found 22

Listing 1 - 10 of 22 << page
of 3
>>
Sort by

Article
Left Ventricular Function in Early Stages of Ischemia

Author: Nadiya Younis Mohammed
Journal: Iraqi Academic Scientific Journal المجلة العراقية للاختصاصات الطبية ISSN: 16088360 Year: 2008 Volume: 7 Issue: 1 Pages: 26-29
Publisher: The Iraqi Borad for Medical Specialization المجلس العراقي للاختصاصات الطبية

Loading...
Loading...
Abstract

ABSTRACT:BACKGROUND:Ischemic heart diseases are common diseases that influence the heart performance via the changesoccurring in cardiac muscles resulting from the disease. These changes can affect the left ventricular wall,septum thickness and an eventual effect on the cardiac performance.AIM OF THE STUDY:The merit of this work is to investigate the effects of left ventricular function on patients who suffer fromearly ischemic heart.METHODS:Twenty five patients complaining from chest pain and diagnosed as angina were subjected to ourinvestigation, they were free from other cardiac diseases and have no previous heart attack their averageage was (52.85±12.69 years old). Eighteen normal individuals (control) with average age (48.33±12.55years old) are chosen and are free from any disease. M-mode, 2- dimensional parasternal long axis viewwas used in the measurements of LV interdiameter, septum and posterior wall thicknesses. Dopplerechocardiography tracing of four chamber apical view was obtained to indicate the ejection time andmitral flow velocities at early diastole E and at atrial contraction (end of diastole) A.RESULTS:The effect of early IHD was found on the interventricular septum (decreased by 44.18%), posterior leftventricular wall (decreased by 47.62%), fractional shortening (decreased by 28.93%), and ejection fraction(decreased by 20.05%). There was no significant change observed on the A/E ratio but a significantchange was seen on E wave only.CONCLUSION:In early of IHD, ejection fraction and percentage changes of wall thickness indicate cardiac performance.In addition reduced early mitral flow velocity is more frequent than the change in early to late mitral flowvelocity ratio.


Article
Characteristic Performance of Deionized Columns

Authors: Mudhafar Y. Hussein --- Nahidh W. Kasser --- Matheel D. Al-Sabti
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2008 Volume: 9 Issue: 1 Pages: 35-43
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The reclamation of makeup water is studied in terms of breakthrough time (i.e., the leakage of the cations). Makeup water was subjected to lab-scale ion exchangers of two types: strong acid cation and weak base anion exchanger. The experimental investigation was directed to study the ion exchanger performance in terms of four different parameters (i.e., copper concentration, total dissolved solids (TDS), feed rate and bed depth). Box-Wilson composite rotatable design was adopted in designing the experiments. Breakthrough times of the effluent stream are measured in terms of copper concentration of 2 to 25 ppm, TDS concentration of 250 to 1250 ppm, feed rate of 0.38 to 5.34 l/h and bed depth of 5 to 70 cm. Simulation the effect of the studied variables through their pre-designed ranges in terms of breakthrough time was done by 2nd order polynomial equation. In general, the performance and characteristic of adopting two bed deionizers (cation and anion beds) was efficiently recommended to remove the ionic contaminants and not less than 95 % of wastewater is recycled.


Article
Quality Assessment of Performance of Health Workers in Health Facilities on District Level in Yemen
تقييم اداء العاملين الصحيين في المراكز الصحية في مناطق اليمن

Authors: Abdul-Munem Al-Dabagh أ.م.د. عبد المنعم يونس الدباغ --- Najat MF Al-Bayatti أ.د. نجاة البياتي --- Hadi Al-Hamzi د. هادي الحمزي
Journal: IRAQI JOURNALOF COMMUNITY MEDICINE المجلة العراقية لطب المجتمع ISSN: 16845382 Year: 2008 Volume: 21 Issue: 3 Pages: 169-175
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Objective: To evaluate the performance of health workers in respect to the acute respiratory infections (ARI) & acute diarrhea in <5 children.Setting: Rural health centers in 11 districts in the reform project in Republic of Yemen.Method: Across sectional study involving 312 cases of ARI & diarrhea. Data were collected through direct observation using WHO algorithm for integrated management of child illness. Performance score was considered as: well done mean ± ISD or poor mean – ISD fair in between sides of SD according to correct element performed Results: The mean score of workers had fair performance 30.4 ± 3.5, 89.4% of workers had fair performance 6.1% well done & 4.5% poor. The performance was better among in workers who received training courses in ARI/ Ad management. There was a decline in performance skills with time lapse after training. There was a high percentage of irrational use of drugs irrespective of the. H workers categoryConclusion: There is a need for promoting health workers efficiency in ARI/ diarrhea management through basic training, refreshing courses & supportive supervisionKeywords: Quality, assessment, performance, health workers

الهدف تقييم اداء العاملين الصحية فيما يتعلق بمعاملة الاطفال تحت سن الخامسة المصابين بالالتهاب الرئوية والاسهال.مكان العمل:- المراكز الصحية الريفية في 11 منطقة المشمولة بمشروع الاصلاح في جمهورية اليمنطريقة العمل:- دراسة مقطعية شملت 312 طفل مريض بالالتهاب الرئوية والاسهال. واعتمدت طريقة الملاحظة المباشرة لاداء الطبيب او المساعدين الطبيين اثناء فحص المريض وتسجيل الملاحظات وحسب الجدول المعتمد من قبل منظمة الصحة العاملية للرعاية الشاملة للطفل المريض وقد قسمت جودة الاداء الى ثلاث فئات جيدة, مقبولة, وسيئة حسب النقاط الصحية التي تؤديها العامل الصحي في تعامله مع الطفل.النتائج:- كان متوسط الاداء الحسابي(3,04± 3,5 ) وكان الاداء عموما لا ئقا في ( 89,4%) مع نسبه اداء جيدة عند (1,6%) وضعيفة عند(5,4%) من العاملين, وقد كان الاداء احسن بين من تلقوا دورات تدريبية في مجال معالجة حالات التهاب الجهاز التنفسي والاسهال بين الاطفال. وكان هناك تدهور في مستوى الاداء بمرور الوقت بين العامـلين.اظهرت الدراسة ان نسبة كبيرة من الادوية وصفت بطريقة غير رشيدة مثلا (91%) للمضادات الحيوية و (90,3%) من الادوية المرضية الاخرى.الاستنتاج:- هناك حاجة لرفع مستوى اداء العاملين الصحيين في كيفية معالجة الامراض التنفسية الحادة والاسهال من خلال التدريب الاساس , الدورات التنشيطية والاشراف العام الفاعل.


Article
High performance organization
منظمات الاداء العالي بحث أستطلاعي في الشركة العامة للصناعات الجلدية والشركة العامة لتصنيع الحبوب

Author: علي حسون الطائي
Journal: journal of Economics And Administrative Sciences مجلة العلوم الاقتصادية والإدارية ISSN: 2227 703X / 2518 5764 Year: 2008 Volume: 14 Issue: 50 Pages: 98-122
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study discussed modern variable in the organizational thought that is the high performance organizations in the two of Iraqi public organizations. The aim of study determines to know the level of the performance in this organizations (high or not). The data was Collected by questionnaire which contain (8) characteristics, the organizational design, strategy, process, technology, leadership, the roles, culture, and external environment). The sample contain from (76) employees;Results points that the two organizations didn’t reach to the high level of performance, and there are significance's difference among them.

يعد موضوع منظمات الاداء العالي (High performance organization) (H.P.O) من الموضوعات المعاصرة في الفكر التنظيمي، وقد بدأت المنظمات المختلفة في تطبيقه وذلك لتعزيز ميزتها التنافسية المستدامة ولهذا ظهرت الحاجة الى دراسة هذا المفهوم في المنظمات العامة العراقية. هدف البحث إلى معرفة مستوى الاداء في أثنين من المنظمات العامة العراقية وهي (الشركة العامة للصناعات الجلدية والشركة العامة لتجارة الحبوب) فيما اذا كان مستوى الاداء ينسجم مع المنطلقات الفلسفية للأداء العالي.
تكونت عينة البحث من مجموعة العاملين فيهما وبمستويات وظيفية مختلفة وتم استخدام الاستبانة كأداة لجمع المعلومات وبلغ عدد الاستمارات المسترجعة(76) استبانه. وقد توصل البحث الى عدم وصول المنظمتين الى مستوى الاداء العالي بالاضافة الى وجود فروق معنوية بينهما في مستوى الاداء الموجود حالياً.


Article
THERMAL DESIGN OF TUBE BANKS IN CROSS FLOW BASED ON MINIMUM THERMODYNAMIC LOSSES
التصميم الحراري لحزمة أنابيب في جريان متقاطع بالاعتماد على اقل الخسائر الثرموديناميكية

Author: Abbas A. S. Al- Jeebori
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2008 Volume: 1 Issue: 2 Pages: 133-143
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Tube banks are widely used in crossflow heat exchangers. Usually, the methods for its design are the NTU or LMTD methods, while in this research the Entropy Generation Method is used. By assuming constant tube wall temperature, a general dimensionless expression for the entropy generation rate is obtained by considering a control volume around a tube bank and applying the conservation equations for mass and energy with the entropy balance. A comparison of the design is accomplished for a tube banks of different stream velocity, lengths and diameters. The heat transferred rate, ambient and tube wall temperatures are 20kW, 300K, and 365K, respectively. From the comparison of the design with the entropy generation rates, the optimal design is obtained. A single objective function is used which is the dimensionless entropy generation rate Ns subjected to the constraints of diameters and pitch ratio. This method of optimization can be applied for any constraints on the system which is the Lagrange optimization method. The effects of tube diameter, tube length, dimensionless pitch ratios, front cross-sectional area of the tube bank, and heat load are examined with respect to its role in influencing optimum design conditions and the overall performance of the tube banks. It is demonstrated that the performance is better for higher air velocities and larger dimensionless pitch ratios. Compact tube banks perform better performance for smaller tube diameters.

إن حزم الأنابيب واسعة الاستخدام في المبادلات الحرارية ذات الجريان المتقاطع . كما إن الطرق الشائعة لتصميها هي طريقة NTU وطريقة LMTD اما في هذا البحث نستخدم طريقة جديدة وهي طريقة تولد الأنتروبي Entropy Generation Method . تم افتراض إن درجة حرارة جدران الأنابيب ثابتة حيث تم الحصول على تعبير رياضي عام لمعدل تولد الأنتروبي بشكل لابعدي dimensionless من خلال تطبيق معادلات حفظ الكتلة والطاقة مع موازنة للطاقة والأنتروبي على حجم التحكم C.V المأخوذ حول حزمة الأنابيب. في هذا البحث تم مقارنة تولد الأنتروبي لحزمة أنابيب ذات أقطار و أطوال وسرع جريان خارجي مختلفة يكون معدل انتقال الحرارة فيها 20kWودرجة حرارة جو 300K ودرجة حرارة جدران الأنابيب 365Kومن مقارنة معدلات تولد الأنتروبي تم اختيار التصميم الأمثل. تمت الأمثلية لدالة هدف واحدة وهي معدل تولد الأنتروبي اللابعديةNs وليقود على الأقطار ونسب الخطوة اللابعدية حيث إن هذه الطريقة ممكن ان تطبق أية قيودconstraints تضاف للنظام وهي طريقة لاكرانج للأمثلية. كذلك تم دراسة تأثير كل من قطر الأنبوب, مساحة مقطع حزمة الأنابيب بالإضافة إلى نسب الخطوة اللابعدية Pitch Ratio على التصميم والأداء الأمثل لمنظومة حزمة الأنابيب. تم التوصل إلى إن الأداء الأمثل يكون عند سرعة جريان خارجي عالية ونسب خطوة لابعدية عالية. إن حزمة الأنابيب المتراصة يكون الأداء الأمثل لكلا النظامين لأقطار أنابيب صغيرة.


Article
Experimental Study Of Fins Perforation Effect On Thermal Performance Of Helically Finned Tubes
دراسة عملية لتأثير تثقيب الزعانف على الأداء الحراري للأنابيب المزعنفة حلزونيا

Authors: Sahra Hassan Ibrahim --- Hanna Abdul Hadi --- IhsanY.Hussain --- Ikhlase M.Fayed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2008 Volume: 14 Issue: 2 Pages: 339-355
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present research includes an experimental study for the effect of fins perforation on the performance of helically finned tubes. The experiments were made on five models of (18 mm) diameter tubes finned spirally with (12mm) high fins perforated with a circular holes , the number of holes was (3-3-6&2 hole /fin) and their diameters were (3,4,2&3mm) respectively .Each tube was tests horizontally by forcing air with(1.5-7.5 m/s) maximum velocity and Reynolds number range ( ) on the tube .The effect of number and diameter of holes were studied.The experimental results showed that the fins perforation increase the overall heat transfer coefficient for all perforated fins tubes, but the percentage increase differs from tube to another. From the comparison of overall heat transfer coefficient for perforated finned tube ((3 hole/fin), (3mm) hole diameter) with unperforated finned tube found that it is increased to (12.3%) at air velocity (4.5m/s), this percentage continue with increasing until to reach (36%) at (7.5 m/s). It is found that for two tubes with same fins dimensions and same number of holes (3 hole/fin), the tube with smaller hole (2mm) is better than that of the larger hole (3mm) by (28%) at (7.5 m/s) maximum air velocity, the increase of the number of holes from (2) to (3) for constant hole diameter (3mm) improves the overall heat transfer coefficient by (7.8%) at (7.5 m/s) maximum air velocity .So the increasing of holes number increase the overall heat transfer coefficient more than the increasing of holes diameter for constant fins surface area (for research case).

تناول البحث دراسة عملية لتأثير تثقيب الزعانف على الأداء ولقد تمت الدراسة على خمسة نماذج من الأنابيب بقطر(18mm) ومزعنفة حلزونيا بزعانف بارتفاع (12mm) مثقبة من منتصفها بثقوب دائرية بعدد(3,3,6,2 hole /fin) وقطر (3,4,2,3mm) على التوالي حيث تم اختبار كل أنبوب أفقيا عند تعرضه لهواء بسرع قصوى تتراوح بين( (1.5-7.5 m/s ولمدى من أعداد رينولد يتراوح بيــن ( ) وقد درس تأثير تغير قطر الثقوب لعدد ثابت من الثـــقوب (3 hole/fin) في كل زعنفة و تأثير تغيير عدد الثقوب لقطر ثابت (3mm) على الأداء.وأظهرت النتائج العملية أن عملية تثقيب الزعانف تؤدي إلى زيادة معامل انتقال الحرارة الإجمالي ولجميع الأنابيب المثقبة ولكن نسبة الزيادة تختلف من أنبوب إلى آخر ،و من مقارنة معامل انتقال الحرارة الإجمالي لأنبوب مثقب )بقطر ثقب ((3 hole/fin),(3mm) مع أنبوب غير مثقب الزعانف وجد انه يزداد بنسبة (12.3%) عند السرعة (4.5m/s) وهذه النسبة تستمـر بالزيادة لتصــل إلى ( 36%) عند السرعة (7.5 m/s) وعند مقارنة أنبوبين متماثلين بأبعاد الزعانف وبعدد الثقوب في كل زعنفة (3 hole/fin) أن الأنبوب المثقب بقطر صغير (2mm) افضل من الآخر المثقب بقطر (3mm) بنسبة(28%) عند السرعة (7.5 m/s) وانه لقطر ثابت للثقوب (3mm) تؤدي زيادة عدد الثقوب من (2) إلى (3) الى تحسين معامل انتقال الحرارة الإجمالي بنسبة (7.8%) لسرعة (7.5 m/s)كذلك زيادة عدد الثقوب تزيد من معامل انتقال الحرارة الإجمالي اكثر من زيادة قطر الثقوب لمساحة سطحية ثابتة للزعانف (لحالة البحث).


Article
Utilizing a cooled Roof to Increase Thermal Performance of The building
استخدام السطح المبرد لتحسين الاداء الحراري للمبنى

Authors: Yahya A. Ebraheem يحيى عادل ابراهيم --- Dr Sahar N. Kharrufa د.سهر نجيب خروفه
Journal: Iraqi Journal of Architecture & Planning المجلة العراقية لهندسة العمارة والتخطيط ISSN: 26179547 / 26179555 Year: 2008 Volume: 4 Issue: 12-13 Pages: 92-104
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The purpose of this paper is to test the use of an evaporative air cooler to cool the roof of a building. It was hoped that this would reduce the temperature inside the building and the cooling load as well when a compressor air conditioning unit is installed.Evaporative cooling is cheap and only uses a fraction of the power that compressor units do. Furthermore its cooling effect increases with the rise in temperature and drop in humidity, conditions that prevail in large parts of Iraq including Baghdad.The test included setting up a thermally insulated compartment above a room inside the campus of the University of Technology. The compartment was cooled by an evaporative cooler. The walls of the room were insulated by adding a 2cm layer of Styrofoam as well as a 10cm air cavity. The readings were taken after three days of operation. The results showed that the combination of roof cooling and wall insulation resulted in a 5.5oC drop in inside temperature. Further calculations showed that this would reduce the cooling load on a compressor air condition by around 38%.

يحاول البحث تجربة حل مقترح لتقليل صرف الطاقة لحمل التبريد بالاستفادة من التبريد التبخيري. التبريد التبخيري يستهلك كمية بسيطة نسبيا من الطاقة وتزداد كفائته في التبريد في الحرارة العالية والرطوبة الواطئة مما يجعله مثاليا للظروف التي تعاني منها بعض المحافظات العراقية بضمنها بغداد.الطريقة المقترحة تشمل تبريد حجرة صغيرة فوق السطح لتنتقل البرودة منها الى داخل الفضاء الداخلي بواسطة السقف. الى هذا الهدف تم استخدام مبنى من غرفة واحدة في الجامعة التكنولوجية وتم تشييد حجرة صغيرة فوقه مغلفة بمادة الفلين العازل سمك 5 سم فوق هيكل من الحديد والخشب. كما تم بناء جدار داخلي اضافي سمك 12سم مع ترك فراغ عازل سمك 10سم وتم كذلك وضع عازل اضافي سمك 2سم من الفلين. في جانب من حجرة السطح وضعت مبردة تبخيرية وتم تشغيلها لمدة ثلاثة ايام ثم اخذ القراءات الحرارية. نتائج القياسات بينت ان هذه الطريقة بامكانها تخفيض درجة الحرارة الداخلية بمقدار 5.5 درجة مئوية بدون ادخال اي رطوبة الى داخل الفضاء وبطريقة تسمح بتشغيل مكيف ضاغط اضافي ايضا. كما بينت الحسابات ان مزيج التبريد السطحي والعازل الجداري بامكانه تخفيض حمل التبريد للمكيف بمقدار 38% تقريبا.


Article
Investigation of the Thermal Performance of A cross-Flow Water Cooling Tower with Different Packings

Authors: Basim A. Rasheed --- A. N. S. Kassim
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2008 Volume: 14 Issue: 1 Pages: 2290-2300
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present research involves experimental and theoretical work to study the performance of three kinds of packing (PVC, corrugated and flat plate asbestos) in a cross-flow water cooling tower under different atmospheric conditions and then comparing the performance of them with each other. The experimental work included the design, constructions and installation of a cross-flow cooling tower test rig suitable for measuring the individual coefficients (kGa) and (k'a). The experimental results were found by varying the inlet air flow rate and inlet water flow rate which are used as an input data to the computer program for finding the available performance coefficient (NTU) using the method of Webb with some modifications. Least square method was then used to correlate the experimental results of (NTU) in terms of water to air ratio (L/G).

يتضمن البحث الحالي دراسة نظرية وعملية لاداء ثلاث انواع من الحشوات (بلاستيكية PVC ، الواح اسبست متموجة و مستوية ) في برج تبريد متعامد الجريان تحت ظروف جوية متغيرة و ظروف تشغيلية مختلفة، ثم مقارنة اداء هذه الحشوات مع بعضها. و قد تطلب العمل تهيئة منظومة برج التبريد و حساب معامل انتقال المادة و الحرارة للبرج بتحليل القياسات العملية. و قد تم في التجارب تغيير كمية الهواء و الماء الداخل و التي اصبحت بيانات دخول الى برنامج حسابي للحصول على معامل الاداء باستعمال طريقة الباحث ( Webb ) مع اجراء بعض التحويرات. و قد استعملت طريقة المربعات الصغرى للحصول على علاقات بين معامل الاداء و نسبة معدل جريان الماء الى الهواء.


Article
Evaluation of the Performance of the Dora Refinery Wastewater Treatment Plant

Authors: Muwafaq A. Abed --- Rafa H. Al-Suhaili
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2008 Volume: 14 Issue: 4 Pages: 3020-3035
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Oil refineries are major contributors to local environmental problems .The main pollutants are oil , dissolved components , spent acids , suspended solids, sludge . Technically it is possible to remove all these pollutants by Physical , chemical and biological means .Oil is initially removed in the (API) separators , by skimming, while the heavy particles by scrapping . Further removal of discrete particles is done by gravity settlement in the primary settlement tank .The remaining suspended matter is removed by chemicals , that are added in the flocculation tank , while further flocs are removed in the air flotation tank . The biological treatment follows to remove the biological pollutants , usually followed by secondary settlement to reduce the flux of suspended particles carried with the effluent water. This thesis deals with the Dora refinery wastewater treatment plant , its present performance in comparison with the designed treatment performance and its final effluents compared with the Iraqi discharged water quality limitations .In order to identify the characteristics of the refinery effluents and to evaluate the performance of the refinery wastewater treatment plant , wastewater from different treatment stages were analyzed for various physical and chemical parameters . Using these parameters as the criteria of performance , comparisons were made between the actual and the designed performance for various potential pollutants. The sampling was conducted during 6 months from May to October 2006 , with two samples in each month for each of the units, one before , and one after.The results showed that the wastewater treatment plant in Al-Dora Refinery performed significantly, where high removal efficiencies , were obtained. For T.S.S , Oil , COD , BOD , Sulfide and Phenol which were 95% , 88% , 86% , 81% , 85% and 97% respectively . And the plant was not very efficient in NH3 , SO4 and PO4 removal .

ان المصافي تعتبر عالميا مساهم رئيسي في مشاكل البيئة الموقعية . اهم الملوثات الناتجة من المصافي والتي تنصرف مع المياه هي النفط ومركباته ,المواد المذابة والعالقة , الحوامض , الحمأة وغيرها . فنيا بالامكان ازالتها جميعا باساليب فيزياوية , كيمياوية وبايلوجية .حيث يتم ازالة النفط اولا في محطة المعالجة في خزانات خاصة للعزل وذلك بترك المياه فيها وقشط النفط الطافي على السطح وكذلك قشط المواد المترسبة في القعر . وتكون عملية الفصل في هذه الخزانات بفعل الجاذبية الارضية . تلي هذه المرحلة عملية فصل للمواد العالقة وذلك بخلط مواد كيمياوية مخثرة مع المياه في خزانات التخثير والدمج ومن ثم يتم تطويف المواد العالقة والمتكتلة في خزانات التطويف حيث يتم قشطها من السطح ومن قعر الخزان باستخدام القاشطات الخاصة لذلك . تتبع هذه العمليات عملية المعالجة البايلوجية , والتي يتم فيها معالجة المواد الذائبة بفعل الاحياء المجهرية (البكتريا ) ومن ثم يتم فصل هذه الملوثات وترسيبها في احواض الترسيب النهائي لفصل ما تبقى من المواد العالقة والمتجمعة والاحياء الحية المجهرية لتقليل جريانها مع المواد المنصرفة الى النهر. المعالجة البايلوجية في مصفى الدورة تستخدم التهوية الممتدة ووحدات الحمأة المنشطة . يتوفر في وحدات المشروع الاجهزة اللازمة للقشط والخلط والتهوية , وأحياء مجهرية حية تتغذى على الملوثات المجهرية . تستخدم هذه الدراسة أسلوب البحث والتحليل الاحصائي للبيانات المستحصلة من قراءات التحاليل الكيميائية للنماذج المأخوذة من مختلف المواقع في محطة المعالجة . وطريقة اخذ النماذج المتبعة كانت نموذج قبل وبعد كل وحدة من وحدات محطة المعالجة ولمدة ستة اشهر وللفترة من ايار وحتى تشرين الاول من عام 2006 وبواقع فحصين كل شهر وللملوثات:- (pH ,Oil , T.S.S , BOD5 ,COD ,N-NH3 ,Sulfide ,Sulfate , Phosphorous and Phenol ) النتائج اظهرت الاداء الكفوء لمحطة المعالجة في ازالة الملوثات (T.S.S ,OIL ,BOD , COD ,Sulfide , Phenol ) حيث سجلت اعلى نسبة ازالة لهذه الملوثات وهي 95% , 88% , 86% , 81% , 85% و97% على التوالي وكذلك النتائج اظهرت ان محطة المعالجة ليست كفوءة جدا في ازالة الملوثات NH3 , SO4 and PO4 .


Article
Using of Waste Materials for Production of High Performance Concrete

Authors: Mohammed Abdulla Baker --- Nadia Salim Ismael
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2008 Volume: 21 Issue: 4 Pages: 182-188
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

High performance concrete with compressive strength (40 – 120) MPa and other perfect properties is a new type of cementitious materials. The research deals with the use of industrial by-product waste material as partial replacement of sand to produce high performance concrete with compressive strength higher than 40 MPa. The result indicate that partial replacement of sand by industrial waste material (Brass) in addition of use of admixtures (Superplasticizer) and powder of pure silica gives high strength in comparative with reference mix.

الخرسانة عالية الاداء التي لها مقاومة انضغاط بين (40-120) ميكاباسكال بالاضافة الى خصائص اخرى تعتبر احد انواع الخرسانة الحديثة.يتضمن البحث استخدام بعض المخلفات الصناعية كاستبدال جزئي للركام الناعم ( الرمل) لانتاج خرسانة عالية الاداء ذات مقاومة انضغاط اكثر من (40) ميكاباسكال . النتائج المختبرية توضح ان الاستبدال الجزئي للرمل بمادة البراص (Brass) الذي يعتبر احد الفضلات الصناعية والتي تتخلف بكميات كبيرة بالاضافة الى استخدام عامل مقلل للماء (Superplasticizer) والسليكا النقية تعطي مقاومة انضغاط عالية مقارنة بالخلط المرجعية .

Listing 1 - 10 of 22 << page
of 3
>>
Sort by
Narrow your search

Resource type

article (22)


Language

English (13)

Arabic (6)

Arabic and English (3)


Year
From To Submit

2008 (22)