research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Simulation of Free Convection from an Inclined HeatedThin Plate in a Square Enclosure
محاكاة انتقال الحرارة بالحمل الحر من صفيحة مسخنة نحيفة مائلة داخل تجويف مربع

Authors: Nora M. Sahib نورا محمد صاحب --- Ahmed N. Mehdy أحمد نعمة مهدي --- Qahtan Abdul Zahra قحطان عبدالزهرة فليح
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2009 Volume: 5 Issue: 2 Pages: 32-43
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Simulation of free convection heat transfer in a square enclosure induced by heated thin plate is represented numerically. All the enclosure walls have constant temperature lower than the plate’s temperature. The flow is assumed to be two-dimensional. The discretized equations were solved stream function, vorticity, and energy equations by finite difference method using explicit technique and Successive Over- Relaxation method. The study was performed for different values of Rayleigh number ranging from 103 to 105 for different angle position of heated thin plate(0°, 45°, 90°). Air was chosen as a working fluid (Pr = 0.71). Aspect ratio of center of plate to the parallel left wall A2 take a constant and is equal to 0.5. The effect of the angle position of the heated thin plate on heat transfer and flow were addressed. With the increase of Rayleigh number heat transfer rate increased in both vertical and horizontal position of the plate. For the vertical situation (γ=90°) of thin plate, heat transfer becomes more enhanced than for the horizontal situation (γ=0°) and the inclined situation (γ=45°) especially when the value of aspect ratio A1 is equal to 0.25.

محاكاة لانتقال الحرارة بالحمل الحر داخل تجويف مربع من صفيحة مسخنة مائلة قد تم دراستها عدديا. كل جدران التجويف محفوظة عند درجات حرارة ثابتة أقل بكثير من درجة حرارة الصفيحة. الجريان فرض على أنه ثنائي البعد. الحل العددي للمعادلات أنجز بواسطة حل معادلات كل من دالة الجريان والدوامية والطاقة بإستخدام الفروق المحددة وتقنية الطريقة الواضحة مع إستخدام طريقة فوق التراخي. الدراسة أنجزت لقيم مختلفة من رقم رايلي (من 103إلى 105) ولأوضاع مختلفة لموقع الصفيحة ولثلاث زوايا(γ =0°, 45°, 90°). الهواء قد تم اختياره كمائع عمل في الدراسة. النسبة الباعية لمركز الصفيحة للجدار الموازي الأيسر قد أخذت بقيمة ثابتة ومساوية 0.5. تأثير زاوية الوضع للصفيحة المسخنة على انتقال الحرارة والجريان قد تم دراسته. خلال النتائج تم التوصل إلى أنه الوضع العمودي للصفيحة المسخنة يكون أفضل من الوضع الأفقي والوضع المائل وخاصة عندما تكون النسبة الباعية A1 مساوية إلى 0.25.


Article
Utilization of exhaust waste heat from power plants for sea water desalination
تسخين حراره النفايات الغازية (العوادم)من محطات توليد الطاقة في تحلية مياة البحر

Authors: Lina Ismail Jassim لينا اسماعيل جاسم --- Ghanim Kadhem Sada غانم كاظم عبد السادة
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2009 Volume: 13 Issue: 4 Pages: 58-68
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The international demand of water increased compared to the available water resources due torecent development water resources for different uses. In many areas especially in Arabian GulfAreas, a shortage of portable water. This study deals with design a model to combine the multi effect desalination water (MED) with the steam power plant. Using the exhaust waste heat of the power plant to heat the sea water. The model has been based upon various heat and mass transfer equations. Taking in consideration all requirements of making available safe drinking water for requirement. The waste heat of the exhaust gases of power plant is captured before exhausting it to the atmosphere and transferred to salty water. The temperature of salty water rise to level 90C to130C. This is ideal temperature for desalination in multiple effect distillation MED plant. The hot salty water then passes through a flash into the evaporator then condenses on the condenser tube bank, and internal heat recovery is achieved by transferring its heat of condensation to the sea water feed that is thus being preheated.In this study selective an exist steam power plants, combine with MED to produce 1000 m3/day to15000 m3/day drinking water from salty water.The cost of combine MED desalination with power plant was compared with the exist desalination methods, the study show that this system less cost than the other methods of desalination.The model is useful in sizing various components, power plant chimney heat exchanger, evaporation and condensation chambers of desalination plant and useful to find out plant output for various combinations of design parameters. The basic motivation for this research and development is to propose a choice of technical options, based on the use of power plant energy, which could be sustainable and at same time economically. The lowest costs with the multi effect desalination (MED) plants are obtained by utilizing virtually free waste heat of power plant.

نتيجة لشحة المياه الصالحة للشرب في منطقة الشرق الاوسط وخاصة منطقة الخليج العربي. تضمن هذا البحث تصميم نموذج لتقطير مياه البحر المالحة للحصول على ماء صالح للشرب باستخدام الحرارة المطروحة من محطات الطاقة الكهربائية لتسخين المياه المالحة، وهذا النموذج يشمل تصميم مجموعة مبادلات حرارية اللازمة لعملية التقطير تتكون المنظومة من مدخنة محطة الطاقة الكهربائية والمبخر والمقطر ومجمعين للملح والماء المقطر، علما ان هذه المنظومة تنتج ما يقارب 1000 متر مكعب الى 15000 متر مكعب ماء صالح للشرب. وتعتبر تلك طريقة اقتصادية للحصول على ماء الشرب مقارنة بتكلفة محطات تحلية المياه.


Article
Immune response to heat shock protein 60 and its relations t enteric reactive arthritis

Authors: Abdal –Razak H. Ahmed --- Mohammed hadi --- Jabbar Salman Hussan
Journal: Karbala Journal of Medicine مجلة كربلاء الطبية ISSN: 19905483 Year: 2009 Volume: 2 no.8, 9 Issue: 5 Pages: 732-736
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

background: according to the molecular mimicry hypothesis, heat shockprotein 60 (hsp60) is among the most conserved proteins that have beenimplicated as triggering agents in the pathogenesis of enteric reactive arthritis(ReA).Objective: In the present work, we aimed to determine the prevalence of anti-hsp60antibodies in sera of patient with enteric reactive arthritis.Methods: Forty-five patients with Reactive arthritis were enrolled in this study. Theywere 22(48.89%) males and 23(51.11%) females, the age rang was 20 - 40 year withmean (33.6 ± 10.6). All patients were outpatient visitor or hospitalized in the medicalCity hospital in Baghdad. They were diagnosed clinically by consultant rheumatologistwith the aid of some laboratory tests such as RF, CRP, E.S.R.The patients should be sero-negative (RF-negative) and fulfill Amor andEuropean Criteria to be included in this study. Patients were classified according todisease activity into three groups: sever moderat and mild by using (DAREA score).Thirty age and sex matched apparently healthy individual, were considered in thisstudy as a control group. ELISA was used to detect immune response against hsp60 inthe sera of each patients and controls. Wells of the micro titter plates were coated withhsp60 in coating buffer and anti hsp60 antibodies were assayed.Results: the mean age of patients was (33.6± 10.6) years and they were 23 femalesand 22 males with females to male ratio 1.05:1, the majority of patients 19(42.22%)present with high disease activity (sever) and 15(33.33%) patients were moderate andthe remainder 11 (24.44%) were mild disease group.The result of anti-hsp60 Abs detection showed that there was highly significantdifference between ReA patients and control groups. Also there was significantdifference between sever, moderate and mild among ReA patients.Conclusion: we concluded that bacterial hsp60 seems to be a major target of T-cellresponse in enteric ReA. and cross reactivity against autologous hsp60 has beendocumented as a triggering of enteric ReA.


Article
Interactions of Breeding Systems and Productive Status of Females with the Month and Year of Breeding and their Effects on Conception Rate and Services per Conception in Holstein Cows
التداخلات بين نظام التلقيح والحالة الإنتاجية للإناث مع شهر وسنة التلقيح وتأثيراتها على نسبة الإخصاب وعدد التلقيحات اللازمة للإخصاب في أبقار الهولشتاين

Authors: S. S. Khalaf سعدي شعلان خلف --- N. N. AL-Anbari نصر نوري الانباري
Journal: Al-Anbar Journal of Veterinary Sciences مجلة الانبار للعلوم البيطرية ISSN: 19996527 Year: 2009 Volume: 2 Issue: 2 Pages: 106-115
Publisher: University of Fallujah جامعة الفلوجة

Loading...
Loading...
Abstract

Breeding records totaling 68844 inseminations at AL-Nasir dairy farm (50 Km South-East of Baghdad) were analyzed to study the interactions between breeding systems and productive status of females with the month and year of breeding and their effects on conception rate (CR) and services per conception (SPC). Data were collected for 10 years from January 1, 1997 to December 31, 2006. Total number of services for lactating (M), dry (D) and virgin heifers (H) and overall means of CR and SPC were 52236, 4503, 12105, 41.65% and 2.61 respectively. In general, CR were not affected significantly (P < 0.01) by the interactions of the month x breeding system except for the month of November and December which differed significantly (P < 0.01) than artificial insemination (AI) of June and September and both AI and natural service (NS) for August. Highest values of CR for AI and NS were in December and November and lowest values were in August, but CR of AI in August (14.85%) differed significantly (P < 0.01) than CR of NS (34.25%) in the same month which indicate a choice of breeding for the hot months of the year. Interactions of productive status of female x month of the year showed that hot months had pronounced effects on CR of M cows but lesser and no effects on CR of D and H respectively. Calculated average CR of hot months (June to September) for M, D, and H were 21.09%, 30.17%, and 56.38%, respectively. Interactions of breeding system x year of breeding revealed overall improvements of CR with successive years for both AI and NS. However, this appeared to be related to improvements in CR of M and D but not in CR of H due to increasing rate of culling of multiparous females. Interactions of breeding system x year of breeding and their effects on SPC indicated general improvements with successive years for both AI and NS. Additionally, interactions of productive status x year of breeding also showed improvement in SPC of M and D but not in SPC of H which again confirm that increasing culling rate of older cows with lower reproductive efficiency led to improvements in SPC with successive years.

تم تحليل سجلات التناسل المتضمنة 68844 تلقيحة العائدة إلى محطة أبقار النصر (50 كم جنوب شرق بغداد) لدراسة التداخل بين نظام التلقيح (اصطناعي أو طبيعي) والحالة الإنتاجية للإناث (حلوب، جافة أو بكر) مع شهر وسنة التلقيح وتأثيراتها على نسبة الإخصاب وعدد التلقيحات اللازمة للإخصاب في أبقار الهولشتاين للفترة من الأول من كانون الثاني 1997 إلى الواحد والثلاثون من كانون الأول 2006. بلغ مجموع التلقيحات في ألأبقار الحلوب والجافة والأباكير والمعدل العام لنسبة الإخصاب وعدد التلقيحات اللازمة للإخصاب 52236، 4503, 12105, 41.65% و2.61 على التوالي. بشكل عام فان نسبة الإخصاب لم تتأثر معنويا (P < 0.01) من التداخل بين شهر التلقيح x نظام التلقيح ماعدا شهري تشرين الثاني وكانون الأول التي اختلفت معنويا (P < 0.01 ) قياسا إلى التلقيح الاصطناعي لشهر حزيران وأيلول وكلا التلقيح الاصطناعي والطبيعي لشهر آب. إن أعلى قيم لنسبة الإخصاب من التلقيح الاصطناعي والطبيعي كانت في شهري كانون الأول وتشرين الثاني وإن أوطأ القيم كانت في شهر آب, لكن نسبة الإخصاب من التلقيح الاصطناعي لشهر آب (14.85%) اختلفت معنويا (P< 0.01) عن نسبة الإخصاب من التلقيح الطبيعي (34.25%) لنفس الشهر مما يدلل على وجود خيارأفضل للتلقيح في اشهر السنة الحارة. التداخل بين الحالة الإنتاجية للإناث x اشهر التلقيح أشارت إلى أن الأشهر الحارة كان لها تأثيرات واضحة على نسبة الإخصاب في الأبقار الحلوب ولكن بدرجة أقل أو بعدم وجود تأثير على كل من الأبقار الجافة والاباكير على التوالي. عند حساب معدل نسبة الإخصاب للأشهر الحارة (حزيران إلى أيلول) للأبقار الحلوب والجافة والاباكير فقد كانت 21.09%, 30.17% و56.38% على التوالي. التداخل بين نظام التلقيح x سنة التلقيح أظهر تحسنا عاما في نسبة الإخصاب مع تقدم سنين التلقيح لكلا نوعي التلقيح, إلا أن ذلك يبدو أن له علاقة بالتحسن في نسبة الإخصاب للأبقار الحلوب والجافة وليس للأباكير وهذا يعزى إلى زيادة نسبة الاستبعاد في الإناث الوالدة سابقا. التداخل بين نظام التلقيح x سنة التلقيح وتأثيراته على عدد التلقيحات اللازمة للإخصاب أشار إلى وجود تحسينات عامة مع تقدم سنين التلقيح لكلا نظامي التلقيح. إضافة لذلك فإن التداخل بين الحالة الإنتاجية x سنة التلقيح أظهر أيضا تحسنا في عدد التلقيحات اللازمة للإخصاب للأبقار الحلوب والجافة ولكن ليس في الاباكير مما يعزز مرة أخرى زيادة نسبة الاستبعاد في الأبقار الكبيرة ذات الكفاءة التناسلية المنخفضة أدى إلى التحسن في عدد التلقيحات اللازمة للإخصاب مع ثقدم سنين التلقيح.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

Arabic and English (4)


Year
From To Submit

2009 (4)