Experimental Investigation of Using Evaporative Air Cooler for Winter Air-Conditioning in Baghdad
دراسة عملية باستخدام مبردة الهواء التبخيرية لغرض تكييف الهواء شتاءاً في بغداد

Authors: Zainab Hasson Hassan زينب حسون حسن --- Zainab Hassan Hanash زينب حسن حنش
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2012 Volume: 8 Issue: 4 Pages: 62-73
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper presents an efficient methodology to design modified evaporative air-cooler for winter air-conditioning in Baghdad city as well as using it for summer air-conditioning by adding a heating process after the humidification process. Laboratory tests were performed on a direct evaporative cooler (DEC) followed by passing the air on hot water through heat exchanger placed in the coolers air duct exit. The tests were conducted on the 2nd of December /2011 when the ambient temperature was 8.1°C and the relative humidity was (68%). The air flow rate is assumed to vary between 0.069 to 0.209 kg/s with constant water flow rate of 0.03 kg/s in the heat exchanger. The performance is reported in terms of effectiveness of DEC, saturation efficiency of DEC, outlet temperature of air and cooling capacity. Heat transfer rate in heat exchanger mode is also estimated. The paper presents the mathematical development of the equations of thermal exchanges through DEC and HE. Prediction of air condition that exits o this system show that the present system could bring the air stream to a comfortable winter zone .

هذا البحث يقدّم نموذج بسيط وفعّال لتطوير مبردة هواء لغرض استخدامها للتدفئة في فصل الشتاء وبما يلائم المناخ في مدينة بغداد، ويتم ذلك بإضافة عملية تسخين بعد عملية الترطيب. تم تصميم وبناء منظومة لهذا الغرض واخذ القراءات المختبرية، حيث تتكون هذه المنظومة من مبردة هواء مرتبطة بمجرى للهواء مثّبت في نهايته مبادل حراري. تم أجراء التجارب في الثاني من شهر كانون الثاني لسنة 2011 حيث كانت درجة حرارة الهواء 8.1°C والرطوبة النسبية 68% ومعدل تدفق الهواء الداخل للمنظومة تتغير بين 0.069 to 0.209 kg/s مع ثبوت تدفق الماء للمبادل الحراري0.03 kg/s . تم الحصول على النتائج على هيئة فعالية مبردة الهواء، كفاءة مبردة الهواء، درجة حرارة الهواء الخارج من المنظومة وسعة التبريد وكذلك تم حساب انتقال الحرارة خلال المبادل الحراري . ان هذا البحث يقدم نموذج رياضي لمعادلات التبادل الحراري خلال مبردة الهواء والمبادل الحراري. على ضوء النتائج التي تم الحصول لظروف الهواء عند خروجه من المنظومة، فقد أثبتت هذه المنظومة فعاليتها وكفاءتها حيث تم الحصول على ظروف مريحة للهواء لفصل الشتاء.


Article
An Experimental Study on the Effect of Shape and Location of Vortex Generators Ahead of a Heat Exchanger
دراسة عملية عن تأثير شكل وموقع مولدات الدوامات عند مدخل المبادل الحراري

Author: Wisam Abed Kattea وسام عبد كاطع
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2012 Volume: 8 Issue: 2 Pages: 12-29
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental study is carried out on the effect of vortex generators (Circular and square) on the flow and heat transfer at variable locations at (X = 0.5, 1.5, 2.5 cm) ahead of a heat exchanger with Reynolds number ranging from 62000< Re < 125000 and heat flux from 3000 ≤ q ≤ 8000 W/m2 .In the experimental investigation, an apparatus is set up to measure the velocity and temperatures around the heat exchanger. The results show that there is an effect for using vortex generators on heat transfer. Also, heat transfer depends on the shape and location. The circular is found to be the best shape for enhancing heat transfer at location [Xm=0.5 cm] distance before heat exchanger is the best location for enhancing heat transfer. The square is the best shape for enhancing heat transfer at location [Xm=2.5 cm] distance before heat exchanger is the best location for enhancing heat transfer.The results of flow over heat exchanger with vortex generators are compared with the flow over heat exchanger without vortex generators. Heat transfer around heat exchanger is enhanced (56%, 50%, 36%) at location (X=0.5, 1.5, 2.5cm) respectively by using circular vortex generators without turbulator and heat transfer around heat exchanger is enhanced (39%, 42%, 51%) at location (X=0.5, 1.5, 2.5cm) respectively by using square shape vortex generators without turbulator.

دراسة عملية أجريت لفحص تأثير مولد الدوامات ( الشبكة الدائرية ، الشبكة المربعة ) على الجريان و انتقال الحرارة عند مواقع (X = 0.5, 1.5, 2.5 cm) قبل مبادل حراري ضمن مدى لرقم رينولد 62000< Re < 125000 و فيض حراري 3000 ≤ q ≤ 8000 W/m2.في الدراسة العملية تم نصب و صيانة جهاز مختبري لقياس السرعة و درجة الحرارة حول المبادل الحراري.أظهرت النتائج أن لوجود مولد الدوامات اثر كبير على تحسين انتقال الحرارة ويعتمد هذا على شكل المولد وموقعهِ. الشبكة الدائرية هي الأفضل لعملية نقل الحرارة عند موقع [Xm=0.5 cm] قبل المبادل الحراري. الشبكة المربعة هي الأفضل لعملية نقل الحرارة عند موقع [Xm=2.5 cm]قبل المبادل الحراري. قورنت النتائج العملية في حالة وجود مولد الدوامات مع عدم وجود مولد الدوامات. أظهرت هذه المقارنة تحسن في انتقال الحرارة حول المبادل الحراري بنسب (56%, 50%, 36%)عند مواقع (X=0.5, 1.5, 2.5cm )على التوالي بأسنخدام مولد الدوامات الدائري الشكل نسبةً الى عدم وجود عوائق جريان،وانتقال الحرارة حول المبادل الحراري يتحسن بنسب (39%, 42%, 51%)عند مواقع (X=0.5, 1.5, 2.5cm ) على التوالي بأسنخدام مولد الدوامات المربع الشكل نسبةً الى عدم وجود عوائق جريان.


Article
Power Plant Waste Heat Utilization for Soil Heating using Subsurface Pipes
استخدام الحرارة الفائضة المشاريع الطاقة في تسخين التربة بأستخدام الانابيب تحت السطحية

Author: Salah Sabeeh Abed-Alkareem صلاح صبيح عبد الكريم
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2012 Volume: 16 Issue: 1 Pages: 273-286
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Warm water is circulated through the soil medium in order to maintain the plant root zone above same critical temperature. In power plants reject heat from steam through the condenser, the waste heat, could be a suitable resource for soil heating. This work presents theoretical and numerical models. Two methods are applied with water temperature (20°C, 30°C, and .50°C) to give the temperature distribution in the soil around buried pipes carrying hot water. The Models used to calculate the required heated land area using the heat from power plants of Daura Steam Power Plant where the discharge 85000m3/hr at Tw = 20°C which is cover the land area (44.7Km2) with piping of (4cm) diameter and length of(10714m). The theoretical results are compared with experimental published work (Johnsion 1976) and showed good agreements.

من الممكن استخدام الحرارة الناتجة (الضائعة) من محطات توليد الطاقة الكهربائية لتدفئة التربة. تتم هذه العملية باستخدام أنابيب مدفونة تحت سطح التربة ويجري بداخلها الماء الحار الخارج من مكثفات محطات توليد الطاقة الكهربائية. لقد تم عمل نموذجين رياضيين لحساب توزيع درجات الحرارة في التربة حول الأنابيب المدفونة تحت سطح التربة والتي يجري بداخلها الماء الحار باستخدام الحاسوب والنموذجــــان هـــما استخدام طريقة التحليل الرياضي (Analytical) والتي طبقت بدرجة حرارة محطة كهرباء الدورة البخارية في بغداد (Tw = 20 0C) ودرجات حرارة أخرى (Tw = 30 0C,50 0C) . وطريقة الفروق المحددة (Finite-Difference) والتي تعطي توزيع درجات الحرارة في التربة مع التغير الزمن وباستخدام الشروط الابتدائية (Initial Conditions) والشروط الحدية(Boundary Conditions) والتي تمثل درجة حرارة سطح التربة (Ts) ودرجة حرارة عمق التربة (Tso) على مسافة 1 متر وبواسطتها يتم ايجاد توزيع درجات الحرارة في التربة بدقة حول الأنابيب المدفونة . ويمكن استخدام هذا الموديل في الأراضي القريبة من محطات توليد الطاقة الكهربائية كأن تكون محطة كهرباء الدورة البخارية والتي يتم خلالها حساب المساحة المراد تدفئتها (44.7 Km2) علما ان درجة حرارة الماء الخارج من المكثفات (20 0C) وكمية الماء الداخل في الأنابيب هي (85000 m3/hr) وبأطوال (10714m) . قورنت النتائج المستحصلة مع النتائج المختبرية المنشورة وتبين بأن النتائج قريبة التطابق مع النتائج المنشورة .


Article
Numerical Study of Fluid Flow and Heat Transfer over a Bank of Oval-Tubes Heat Exchanger with Vortex Generators
دراسة عددية للجريان وانتقال الحرارة في مبادل حراري من صف من الأنابيب البيضوية بوجود مولدات الدوامة

Author: Abdulmajeed A. Ramadhan عبد المجيد عبد الحميد رمضان
Journal: Anbar Journal of Engineering Sciences مجلة الأنبار للعلوم الهندسية ISSN: 19979428 Year: 2012 Volume: 5 Issue: 1 Pages: 88-108
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

The present work represents a two-dimensional numerical investigation of forced laminar flow heat transfer over a 3-rows oval-tube bank in staggered arrangement with rectangular longitudinal vortex generators (LVGs) placed behind each tube. The effects of Reynolds number (from 250 to 1500), the positions (3 in x-axis and 2 in y-axis) and angles of attack (30o and 45o) of rectangular VGs are examined. The study focuses on the Influence of the different parameters of VGs on heat transfer and fluid flow characteristics of three rows oval-tube banks. The characteristics of average Nu number and skin friction coefficient are studied numerically by the aid of the computational fluid dynamics (CFD) commercial code of FLUENT 6.3. The results showed increasing in the heat transfer and skin friction coefficient with the increasing of Re number and decreasing the relative distance of positions of LVGs. It has been observed that the overall Nuav number of three oval-tubes increases by 10–20.4% and by 10.4–27.7% with angles of 30o and 45o respectively, with increasing in the overall average of skin friction coefficient of three oval-tubes reached to 53% and 72% with two angles used respectively, in comparison with the case without VGs.

يتناول البحث المقدم دراسة عددية ثنائية البعد لجريان طباقي لفحص خواص الجريان وانتقال الحرارة لثلاثة صفوف من أنابيب بيضوية الشكل (عند ثبوت درجة حرارة السطح) مرتبة بشكل متخالف بوجود زوج من مولدات الدوامة مستطيلة المقطع إلى الخلف من كل أنبوب. ركزت الدراسة التي أجريت ضمن مدى عدد رينولدز (1500-250) على تأثير مواقع وزوايا الهجوم لمولدات الدوامة على تحسين انتقال الحرارة وتأثيرها في معامل الاحتكاك السطحي للأنابيب. تم اختيار ستة مواقع (ثلاثة باتجاه الجريان واثنان باتجاه متقاطع معه) تمثلت في ست مسافات نسبة إلى نصفي قطري الشكل البيضوي، إضافة إلى اختيار زاويتي هجوم (30o) و (45o). تم حل المعادلات الحاكمة باستخدام البرنامج العددي المسمى (FLUENT 6.3) مع اعتبار الجريان انسيابي والحالة مستقرة. أظهرت الدراسة تحسناً في انتقال الحرارة ممثلاً بمعدل عدد نسلت للأنابيب بسبب وجود مولدات الدوامة مقارنة مع الحالة في عدم وجودها، وأن هذا التحسن يقل بزيادة المسافات النسبية لمواقع مولدات الدوامة. حيث بلغ أعلى تحسن نسبي في المعدل الإجمالي لعدد نسلت (20.4%) و (27.7%) عند المسافات النسبية الصغيرة مع زاويتي لهجوم (30o) و (45o) على التوالي. وأن الزيادة في المعدل الإجمالي لمعامل الاحتكاك السطحي للأنابيب الثلاثة المرافقة للتحسن في انتقال الحرارة بلغت (53%) و (72%) لزاويتي الهجوم أعلاه على التوالي.


Article
Experimental Investigation into the Heat and Mass Transfer in an Indirect Contact Closed Circuit Cooling Tower
التحقق العملي من انتقال الحرارة والكتلة في برج تبريد نوع مغلق و ذي اتصال غير مباشر

Authors: Najim Abid Jassim نجم عبد جاسم --- Mohammed A. Al-Tayyar محمد عبد الخالق الطيار
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 11 Pages: 1255-1265
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The heat and mass transfer coefficients of the indirect contact closed circuit cooling tower, ICCCCT, were investigated experimentally. Different experiments were conducted involving the controlling parameters such as air velocity, spray water to air mass flow rate ratio, spray water flow rate, ambient air wet bulb temperature and the provided heat load to investigate their effects on the performance of the ICCCCT. Also the effect of using packing on the performance of the ICCCCT was investigated. It was noticed that these parameters affect the tower performance and the use of packing materials is a good approach to enhance the performance for different operational conditions. Correlations for mass and heat transfer coefficients are presented. The results showed a good agreement with other published works. Correlations are showed that the spray heat transfer coefficient is a function flow rates of spray water and air as well as spray water temperature while mass transfer coefficient is a function of spray water and air flow rates only.

تضمن هذا البحث دراسة معاملي إنتقال الحرارة والكتلة لبرج تبريد من النوع المغلق ذي الإتصال غير المباشر عملياً. حيث تم إجراء عدد من التجارب بتغيير العوامل الحاكمة في أداء برج التبريد كسرعة الهواء، نسبة معدل التدفق الكتلي بين ماء الرش والهواء، معدل تدفق ماء الرش، درجة حرارة البصلة الرطبة للهواء الخارجي و الحمل الحراري المجهز من أجل تحري تأثيرات هذه العوامل على أداء البرج. كذلك فقد تم أيضاً تحري تأثير إستخدام الحشوات على الأداء الحراري للبرج. لقد بينت النتائج أن لهذه العوامل تأثيرات واضحة على أداء البرج وإن استخدام الحشوات طريقة جيدة لتحسين الأداء ولظروف تشغيلية مختلفة. تم تقديم معادلات تجريبية لمعاملي إنتقال الكتلة والحرارة وأظهرت هذه المعادلات توافقاً جيداً مع الأعمال المنشورة في الأدبيات. بينت المعادلات التجريبية أن معامل إنتقال الحرارة يعتمد على معدل تدفق كل من ماء الرش والهواء إضافةً إلى درجة حرارة ماء الرش في حين إن معامل إنتقال الكتلة يعتمد على معدل تدفق ماء الرش والهواء فقط.


Article
Heat-Intolerance Syndrome subsequent Foot-and-Mouth Disease in Cattle; ThiQar –Iraq
متزامنة عدم تحمل الحرارة المرافقة للإصابة بالحمى القلاعية في الأبقار: ذي قار العراق

Loading...
Loading...
Abstract

The investigation on Heat-Intolerance Syndrome following foot and mouth disease (FMD) infection in cattle in ThiQar–Iraq, used 3ABC FMD ELISA kit, and Radio- immunoassay (RIA) to detect the cortisol level. From 105 there were 65(62%) infected cattle with FMD, which was high at 5- less 8 years old, while the cortrisol level showed three levels; normal (13-21 nmol⁄L), high and low levels were; 6(5.6%), 44(42%) and 55(52%) subsequently. More over the combined result of ELISA and RIA had divided cattle into six groups. First group of 40(38%) cattle infected with FMD and had low level of cortisol, this group containing 21(20%) with clinical signs of heat intolerance. Second group contain 22(21%) FMD infected cattle with high level of cortisol. Third group of 3(2.8%) FMD Infected cattle but normal cortisol level. Fourth group included 3(2.8%) not infected by FMD with normal cortisol level. Fifth group contain 22(21%) not infected with FMD but had high level of cortisol may related to stress. Sixth group consisted 15 (14%) cattle not infected with FMD and had low level of cortisol due to un known cause. Clinical signs of heat intolerance that showed in 21 head of cattle in the first group were: panting, overgrowth of hair coat, emaciation and seeking for shad. The diseased cow known locally as ”Mahrorah” meaning heat-intolerance.

عدت هذه الدراسة للتحري عن متزامنة عدم تحمل الحرارة بعد الإصابة بمرض الحمى القلاعية في الأبقار في محافظة ذي قار , وذلك باستخدام عدة الاليزا (3ABC FMD ELISA kit ) وفحص هرمون الكورتيزول بالتحليل الاستشعاعي الممنع لمصل الدم من خلال فحص (105) رأسا من الأبقار وجد 65(62%) مصابا بالحمى القلاعية وكانت الإصابة في أوجها بعمر من 5-اقل من 8 سنوات بينما كان مستوى هرمون الكورتيزول الطبيعي 13-21 مل مول وظهر في الأبقار بمستويات من الأعلى إلى الأقل على التوالي: 6(5و6%) و 44(42%) و 55(52%) علاوة على ذلك إن ربط علاقة نتائج الكشف بالا ليزا مع مستوى الكورتيزول وزعت الأبقار إلى ستة مجاميع:المجموعة الاولى من 40(38%) أبقار مصابة بالحمى القلاعية وتحمل مستوى واطئ من هرمون الكورتيزول وقد اشتملت هذه المجموعة على 22(21%) رأسا يعاني من علامات سريرية لعدم تحمل الحرارة ∙ والمجموعة الثانية من 22(21%) أبقار مصابة بالحمى القلاعية وتحمل مستوى عال من الكورتيزول∙ والمجموعة الثالثة من 3(2,8%) أبقار مصابة بالحمى القلاعية ولكنها تحمل مستوى طبيعي للكورتيزول , والمجموعة الرابعة شملت 3(2,8%) أبقار غير مصابة بالحمى القلاعية وكذلك ذات كورتيزول بمستوى طبيعي , والمجموعة الخامسة تألفت من 22(21%) أبقار غير مصابة بالحمى القلاعية ولكنها تحمل مستويات عالية من الكورتيزول ربما بسببالإجهاد, والمجموعة السادسة كانت من 15(14%) أبقار غير مصابة بالحمى القلاعية مع ذلك تحمل مستوى واطئ للكورتيزول لأسباب غير معرفة∙ وتميزت العلامات السريرية لعدم تحمل الحرارة في 21 رأسا من الأبقار ضمن المجموعة الاولي باللهاث وزيادة نمو شعر الجسم والهزال والبحث عن الظل وعرفت البقرة المصابة بالمرض بين القرويين في تلك المناطق بالمحرورة وتعني عدم تحمل الحرارة .

Keywords

Heat-Intolerance --- FMD --- Cattle --- ABC- ELISA --- RIA --- cortisol --- ThiQar --- Iraq


Article
Heat Transfer and Pressure Drop in Turbulent Flow through an Eccentric Converging-Diverging Tube with Twisted Tape Inserts

Author: Mohammed Najm Abdullah
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2012 Volume: 16 Issue: 2 Pages: 178-192
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The aim of this study is to investigate the heat transfer and pressure drop characteristics in an Eccentric Converging-Diverging Tube (ECDT) with twisted tape inserts. Experiments were conducted with tape inserts of three different twist ratios. Cold and hot water are used as working fluids in shell and tube sides, respectively. The effect of the twist ratio and other parameters on heat transfer characteristics and pressure drop are considered. The experimental data for the plain tube and (ECDT) without inserts are compared with (ECDT) with twist tape insert. The results show that the twist tape insert has significant effect on the enhancement of heat transfer. The Nusselt numbers for the (ECDT) are found to be 15% to 45% higher than of the plain tube while for the (ECDT) combined with twisted tape insert is found 52% to 280% higher and pressure drop is found 6.8 times the plain tube. Moreover, (ECDT) combined with a twisted tape insert gives higher heat transfer rate and pressure drop than the (ECDT) alone around 23% to 35% and 98% to 125%, respectively.

هدف هذه الدراسةِ التحقق من خصائص انتقال الحرارةَ وهبوط الضغط ِ في Eccentric Converging-Diverging Tube (ECDT) بوجود الشريط الملتويِ. أجريت التجارب ِ بنسب ليّ مختلفة وبعدد ثلاث.تم استخدام الماء البارد والحار في المبادل الحراري نوع Double Pipe Heat Exchanger،. تم الأخذ بعين الاعتبار تأثير نسبة الليّ والعوامل الأخرى على خصائص انتقال الحرارة و وهبوط الضغط . تم إجراء التجارب للأنبوب الدائري و (ECDT)بدون وجود الشريط الملتويِ و مقَارنتها مع (ECDT) بوجود الشريط الملتوي وقد أظهرت النتائج تأثير الشريط الملتوي على تحسينِ انتقالِ الحرارة. ان رقم نسلت ل(ECDT) كَانَ % 15 إلى 45% أعلى من ذلك للأنابيب الدائرية بينما ل(ECDT) وبوجود الشريطِ الملتويِ كانت52% الى 280%وهبوط الضغط كان أعلى بـ 6.8 مرةِ من التي للأنابيب الدائرية. علاوة على ذلك، (ECDT) بوجود الشريط الملتوي حقق زيادة في معدل انتقال الحرارة والهبوط في الضغط أعلى من (ECDT) بدون الشريط الملتوي حوالي % 23 إلى 35% و% 98 الى %125 على التوالي.


Article
Compound Heat Transfer Enhancement in Dimpled and Sinusoidal Metal Solar Wall Ducts Fitted with Wired Inserts

Authors: Abeer H. Faleh --- Fouad A. Saleh --- Mohammed H. Mahmoud
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 5 Pages: 591-610
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An improved Metal Solar Wall (MSW) with integrated thermal energy storage is presented in this research. The proposed MSW makes use of two, combined, enhanced heat transfer methods. One of the methods is characterized by filling the tested ducts with a commercially available copper Wired Inserts (WI), while the other one uses dimpled or sinusoidal shaped duct walls instead of plane walls. Ducts having square or semi-circular cross sectional areas are tested in this work. A developed numerical model for simulating the transported thermal energy in MSW is solved by finite difference method. The model is described by system of three governing energy equations. An experimental test rig has been built and six new duct configurations have been fabricated and tested. Air is passed through the six ducts with Reynolds numbers from 1825 to 7300. Six, new, correlations for Nusselt number and friction factor are developed to assess the benefits that are gained from using the WI and the dimpled and sine-wave duct walls. It is found that higher heat transfer rates are achieved using the Dimpled, semi–circular duct with Wired Inserts (DCWI). Also, it is found that Nusselt number and the pressure drop in the DCWI are respectively (44.2% -100%) and (101.27% - 172.8%) greater than those of the flat duct with WI. The improvement in Nusselt number for flat duct with WI is found to be (1.4 – 2) times the values for flat duct with no WI. The results demonstrated that DCWI provides enhancements efficiency value that is higher than those obtained from other types of ducts. The developed MSW ducts have added to local knowledge a better understanding of the compound heat transfer enhancement.

في هذاالبحث تم تقديم جدار معدني شمسي (MSW) مطور ذو قابلية خزن حرارية ضمنية. ان الجدار المقترح يستخدم طريقتين لتحسين انتقال الحرارة. الطريقة الاولى تتضمن إملاء قنوات الجريان بحشوات نحاسية من الأسلاك (WI) المتوفرة تجاريا اما الطريقة الثانية فتستخدم مجاري الهواء ذات الجدران المتموجة جيبيا او المقعرة بدلا من المجاري ذات الجدران المستوية. لقد تم اجراء البحث على مجاري ذات مقاطع مربعة و نصف دائرية . تم اجراء الحل للموديل العددي المطور الخاص بمحاكاة الطاقة الحرارية المنقولة باستخدام طريقة الفروقات المحددة. ان هذا الموديل العددي مكون من منظومه من ثلاثة معادلات حاكمه للطاقه. تم في هذا البحث بناء جهاز أختبار عملي وتم تصنيع وأختبار ستة مجاري هواء وإمرار الهواء خلال المجاري ضمن مدى لرقم رينولدز من 1825 الى 7300. من النتائج المستحصلة من هذا البحث تم استحداث ستة معادلات جديدة خاصة برقم ناسلت و معامل الاحتكاك لتخمين الفوائد المكتسبة من الأستعمال المركب لكل منWI و مجاري الهواء ذات الجدران المتموجة جيبيا او المقعرة. لقد وجد ان اعلى معدل لانتقال الحرارة هو للمجرى المدمل ذو المقطع نصف الدائري المحشو (DCWI). النتائج بينت ان نسب رقم ناسلت ومقدار الانخفاض بالضغط للمجرى نوع DCWI هي على التوالي (44.2%-100% ) و (101.27%-172.8% ) اعلى من تلك العائدة الى المجرى المسطح مع WI . وجد ان التحسينات في رقم ناسلت قد بلغت ( 1.4 - 2 ) مرة بالنسبة للمجرى المزود ب WI بالمقارنة مع تلك غير المزودة ب WI.بينت النتائج الخاصة بالبحث الحالي ان الموديل المطور لمقترح DCWI يعطي كفاءة تحسين اعلى من الموديلات الاخرى. النتائج المستخلصة في هذا البحث أضافت للمعرفة المحلية فهم أفضل لتحسين انتقال الحرارة المركب.


Article
Simulation of Heat Storage and Heat Regeneration in Phase Change Material

Authors: Khalid Ahmed Joudi --- Ahmed Kasim Taha
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 9 Pages: 1055-1072
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present study explores numerically the energy storage and energy regeneration during Melting and Solidification processes in Phase Change Materials (PCM) used in Latent Heat Thermal Energy Storage (LHTES) systems. Transient two-dimensional (2-D) conduction heat transfer equations with phase change have been solved utilizing the Explicit Finite Difference Method (FDM) and Grid Generation technique. A Fortran computer program was built to solve the problem. The study included four different Paraffin's. The effects of container geometrical shape, which included cylindrical and square sections of the same volume and heat transfer area, the container volume or mass of PCM, variation of mass flow rate of heat transfer fluid (HTF), and temperatures difference between PCM and HTF were all investigated. Results showed that the PCMs in a cylindrical container melt and solidify quicker than the square container. The increase in mass flow rate and/or temperature difference decreases the time required for complete phase change. Paraffin's solidify quicker than they melt and store more energy than they release.

تتحرى الدراسة الحالية عددياً الطاقة المخزونة والطاقة المتحررة أثناء عمليتي الذوبان والانجماد في مادة متغيرة الطور تستخدم في منظومات خزن الحرارة الكامنة. حلت معادلة انتقال الحرارة الانتقالية باتجاهين باستخدام طريقة الفروق المحددة الصريحة وبتقنية التوليد الشبكي. تم بناء برنامج حاسوبي بلغة فورتران لحل المسألة. تتضمن الدراسة أربعة برافينات متغيرة الطور, تأثير الشكل الهندسي لوحدة الخزن الذي تضمن المقطعين الدائري والمربع للحجم نفسه و مساحة انتقال الحرارة نفسها, حجم الخزان أو كتلة المادة المتغيرة الطور, تغيير نسبة التدفق لسائل نقل الحرارة, وفرق درجات الحرارة بين المادة متغيرة الطور وسائل نقل الحرارة. بينت النتائج إن المادة متغيرة الطور في وحدات الخزن الحراري الاسطوانية تذوب وتتجمد أسرع مما في وحدات الخزن الحراري المربعة. زيادة نسبة التدفق و فرق درجات الحرارة يقلل الزمن اللازم لتغير الطور التام. البرافينات تتجمد أسرع مما تذوب وتخزن طاقة أكثر مما تحرر.


Article
Experimental Study on the Impact of External Geometrical Shape on Free and Forced Convection Time Dependent Average Heat Transfer Coefficient during Cooling Process
دراسة عملية لتاثير تغيير الشكل الخارجي للجسم على المعدل الزمني لمعامل انتقال حرارة للحمل الحر والقصري خلال عملية التبريد

Author: Sundus Hussein Abd سندس حسين عبد
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2012 Volume: 8 Issue: 4 Pages: 74-89
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research, an experimental study was conducted to high light the impact of the exterior shape of a cylindrical body on the forced and free convection heat transfer coefficients when the body is hold in the entrance of an air duct. The impact of changing the body location within the air duct and the air speed are also demonstrated. The cylinders were manufactured with circular, triangular and square sections of copper for its high thermal conductivity with appropriate dimensions, while maintaining the surface area of all shapes to be the same. Each cylinder was heated to a certain temperature and put inside the duct at certain locations. The temperature of the cylinder was then monitored. The heat transfer coefficient were then calculated for forced convection for several Reynolds number (4555-18222).The study covered free convection impact for values of Rayleigh number ranging between (1069-3321). Imperical relationships were obtained for all cases of forced and free convection and compared with equations of circular cylindrical shapes found in literature. These imperical equations were found to be in good comparison with that of other sources.

تم في هذا البحث اجراء دراسة عملية عن تأثير الشكل الخارجي لجسم اسطواني على معامل انتقال الحرارة الناتج عن الحمل القسري والحمل الحر عند وضع هذا الجسم داخل مجرى هوائي وكذلك لبيان تاثير تغير موقع الجسم داخل مجرى الهواء وسرعة الهواء على قيم معامل انتقال الحرارة بالحمل القسري والحمل الحر مع تغير الشكل الخارجي . حيث تم تصنيع اسطوانات (دائرية ومثلثة و مربعة المقطع ) من معدن النحاس لموصليته الحرارية العالية بابعاد مناسبة مع المحافظة على ثبوت المساحة السطحية لجميع الاشكال وتسخينها الى درجة حرارة معينة ووضعها داخل مجرى الهواء بمواقع محددة ومراقبة انخفاض درجة حرارة الاسطوانة وتم حساب معامل انتقال الحرارة بالحمل القسري لقيم عدد رينولدز تتراوح بين (18222-4555) وبيان تاثير تغير السرعة غلى معامل انتقال الحرارة بالحمل القسري واجريت كذلك دراسة الحمل الحر وبيان تاثيره غلى معامل انتقال الحرارة لقيم عدد رايلي تتراوح بين (1069.320-3321.682). وتم الحصول على علاقة تجريبية في حالة الحمل القسري لجميع اشكال الاسطوانة وتم مقارنتها مغ المعادلات التجريبية الموجودة في مصادر الاشكال الاسطوانية الدائرية وكانت قيم الثوابت مقاربة بشكل جيد للقيم الموجودة في المعادلات التجريبية في المصادر الاخرى.

Listing 1 - 10 of 13 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (13)


Language

Arabic and English (13)


Year
From To Submit

2012 (13)