Numerical Study of Solar Chimney with Absorber at Different Locations
دراسة نظرية لمدخنة شمسية لمواقع مختلفة للسطح الماص

Authors: Karima E. Amori كريمة أسماعيل عموري --- Khawla Naeem Hmood خولة نعيم حمود
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 4 Pages: 485-499
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Heat transfer process and fluid flow in a solar chimney used for natural ventilation are investigated numerically in the present work. Solar chimney was tested by selecting different positions of absorber namely: at the back side, front side, and at the middle of the air gap. CFD analysis based on finite volume method is used to predict the thermal performance, and air flow in two dimensional solar chimney under unsteady state condition, to identify the effect of different parameters such as solar radiation. Results show that a solar chimney with absorber at the middle of the air gap gives better ventilation performance. A comparison between the numerical and previous experimental results shows fair agreement.

تم إجراء درسة عددية لعملية انتقال الحرارة وجريان المائع في المدخنة الشمسية. اختبرت المدخنة الشمسية بأختيار مواقع مختلفة للسطح الماص وتحديدا" بوضع السطح الماص على الجانب الخلفي ، الجانب الأمامي ، وفي منتصف فجوة الهواء. تم استخدام تحليل ديناميك الموائع الحسابية وبأعتماد طريقة الحجوم المحددة لتحديد الأداء الحراري وجريان الهواء في مدخنة شمسية ببعدين ولظروف غير مستقرة لبيان تأثير عوامل مختلفة مثل الأشعاع الشمسي. بينت النتائج ان المدخنة الشمسية بسطح ماص في منتصف الفجوة الهوائية يؤدي افضل تهوية . بينت المقارنة بين النتائج الحالية والنتائج التجريبية السابقة توافقا مقبولا".

Listing 1 - 1 of 1
Sort by
Narrow your search

Resource type

article (1)


Language

English (1)


Year
From To Submit

2013 (1)