research centers


Search results: Found 61

Listing 1 - 10 of 61 << page
of 7
>>
Sort by

Article
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger

Loading...
Loading...
Abstract

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as column height, Freon R11 mass flow rate and initial temperature of water on the average percentage holdup, heat transfer rate, volumetric heat transfer coefficient and effectiveness. The obtained experimental results showed that the average percentage holdup increased with increasing in the process variables. The heat transfer rate increased clearly with increasing in mass flow rate of Freon R11 while it increased very little when column height and initial temperature of water increased, it increased two times when increase the mass flow rate from 1.8 to 5.4 kg/hr. The volumetric heat transfer coefficient was found to decrease with increasing in column height and initial temperature of water, while it was increased with increasing in mass flow rate of Freon R11. The effectiveness was found to increase (maximum 90%) with increasing in column height and decreasing in the mass flow rate of Freon R11 and initial temperature of water. A statistical analysis was performed to get general correlations for the average percentage holdup, heat transfer rate, volumetric heat transfer coefficient and effectiveness as a function of the studied parameters


Article
Experimental and Numerical Investigation to Evaluate the Performance of Helical Coiled Tube Heat Exchanger
تحقيق عملي وعددي لتقييم أداء مبادل حراري حلزوني الأنبوب

Authors: Qasim Saleh Mahdi قاسم صالح مهدي --- Sahar Abdul Fattah سحر عبد الفتاح عبود --- Firas juma Abd فراس جمعة
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 4 Pages: 89-110
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Experimental and Numerical investigation of heat transfer enhancement in shell and helical coil tube heat exchanger is carried out in the present work. Experimental work included design of helical coil heat exchanger with different curvature ratio and coil pitch. Three helical coil tube heat exchangers with different curvature ratio (D/d) 12/1, 15/1, 17/1, 20/1 and 24/1 are studied to choose the optimum one. Four helical coils with different coil pitch 1.8d, 2d, 3d, and 5d has been chosen to study the effect of coil pitch on heat transfer coefficient. From experimental results the curvature ratio 17/1 gives optimum helical coil. Experimental results show increases of coil pitch lead to increasing in heat transfer coefficient of the shell side and indicate that convective heat transfer is increased by Reynolds number as well as Dean Number.Numerical geometry has been built using ansys fluent package 14.1 commercial copy with solid work and gambit software program depends on the optimum design . Numerical results show that the temperature decreases along the coil and the temperature difference effect on heat flow along helical coiled. Also there is different in temperature between each turn. Empirical correlation has been developed to predict Nusselt number at helical coil. The comparison between numerical and experimental results show good agreement.

التحقيق التجريبي والعددي لتحسين انتقال الحرارة لمبادل حراري مكون من أسطوانة (القشرة) وأنبوب حلزوني نفذت في هذا العمل .تضمن العمل التجريبي تصميم مبادل حراري حلزوني مع أفضل نسبة تقوس ودرجة حلزنة. خمسه مبادلات حرارية حلزونية مع نسب تقوس مختلفة24/1, 20/1, 17/1, 15/1, 12/1 درست لاختيار أفضل مبادل حراري حلزوني. أربعة مبادلات حرارية مع درجات حلزنة مختلفة (1.8d, 2d, 3d, 5d) صممت لدراسة تأثير درجة الحلزنة على معامل انتقال الحرارة. الملف الحلزوني الذي له نسبة تقوس17/1 اختير كأفضل ملف حلزوني طبقا للنتائج العملية. زيادة درجة الحلزنة تؤدي إلى زيادة معامل انتقال الحرارة في (القشرة). النتائج العملية تشير إلى إن انتقال الحرارة يزداد بزيادة رقم رينولد بالإضافة إلى رقم ديان.أما الجانب العددي فقد تم استخدام برنامج ansys fluent في رسم الشكل باستخدام برنامج solid workو gambit في التحليل وبالاعتماد على أفضل تصميم. وأظهرت الدراسة العددية ان درجات الحرارة تقل على طول الملف وفرق درجات الحرارة له تأثير على انتقال الحرارة وهناك فرق في درجة الحرارة بين لفة واخرى .تم تطوير معادلة تجريبية لتوقع عدد ناسلت لأنبوب محلزن كما بينت المقارنة بين النتائج العملية والعددية بينت توافق جيد.


Article
Evaluation of the effect of sodium fluoride addition on some mechanical properties of heat cure acrylic denture base materials

Author: Ali AM
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2014 Volume: 26 Issue: 4 Pages: 9-13
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: The geriatric patients wearing removable partial dentures are increasing in proportion. At the sametime, the root caries prevalence accompanied by gingival recession is increasing. A variety of vehicles can deliverfluoride into the oral cavity, including fluoride mouth-rinse, fluoride dentifrice, topical fluoride, and fluoride-releasingrestorative materials, all of which effectively prevent root caries and suppress recurrent caries. This study aimed toevaluate the effect of sodium fluoride addition on some mechanical properties of heat cure acrylic denture basematerial.Material and method: A total of 90 samples were prepared in this study, then divided into three main groupsaccording to the type of test used (hardness, tensile and transverse strength tests). Each main group was subdividedinto three main subdivisions according to percentage of sodium fluoride addition to the heat cure acrylic denturebase material (control no addition, 2%NaF ,and 5%NaF sodium fluoride groups)Results: The sodium fluoride addition to acrylic denture base materials showed slight but non significant increase intransverse strength and tensile strength tests while the results showed significant and highly significant differences for2%NaF and for 5%NaF shore D hardness groups respectively.Conclusions: Addition of 2% and 5% sodium fluoride to heat cure acrylic resin is considered advantageous as themechanical properties of resin denture base materials in respect to hardness tensile and transverse strength were notadversely affected.

خلفیّة : نسبة المرضى المسنین الذین یرتدون اطقم أسنان متحركة في ازدیاد مستمر. في الوقت نفسھ, نسبة تسوس الجذر المرافقة بفترة ركود لثویّة في ازدیاد ایضأ.عدة مصادر استخدمت لغرض نقل مادة الفلوراید الى تجویف الفم, بما في ذلك المضمضة الفمویة الحاویة على الفلورید, معجون الأسنان ,الفلورید المضاف لاسطحالاسنان, و حشوات الاسنان الباعثة للفلوراید, كل من ھذه المصادر یمنع بشكل فعّال تسوس جذر الاسنان ویوقف معاودة التسوس. ھذه الدراسة تھدف إلى تقییم تأثیرإضافة صودیوم فلورید على بعضالخواصالمیكانیكیة والفیزیائیة لاطقم الاسنان المصنوعة من الراتنج الاكریلي الحراريطرق ومواد: أعدّت مجموعة من 90 عینة في ھذا الدراسة, بعد ذلك قسمت الى ثلاثة مجامیع رئیسیّة وفقا لنوع الإختبار المستعمل (الصلادة ,الشد و الشدالعرضي). قسمت كلّ مجموعة رئیسیّة الى ثلاث مجامیع جزئیة وفقا للنسبة المئویّة من مادة صودیوم فلورید المضافة إلى مادة الراتنج الاكریلي الحراري (ما منإضافة, 2بالمئة, و 5 بالمئة صودیوم فلورید)النتائج :أبدت نتائج إضافة الصودیوم فلورید إلى مادة الراتنج الاكریلي الحراري فروقات غیر ھامة لإختبارات الشد والشد العرضي بینما كانت الفروقات ھامةوھامّة جدّا لاختبار الصلادة وللمجامیع 2بالمئة ول 5 بالمئة على التّوالي .استنتاج :اعتبرت إضافة من 2% و 5% صودیوم فلورید إلى مادة الراتنج الاكریلي الحراري اضافة مفیدة بما أنّ الخواص المدروسة (الصلادة ,الشد و الشدالعرضي) لم تتأثر بشكل سلبي.


Article
Thermo-Hydraulic Performance of Horizontal Circumferentially Ribbed Double Pipe Heat Exchanger
الأداء الحراري-الهيدروليكي لمبادل حراري أفقي مزدوج الأنبوب مضلع بشكل محيطي

Author: . Nawras Shareef Sabeeh . نورس شريف صبيح
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 3 Pages: 183-196
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Heat transfer coefficient and pressure drop for water flow inside circumferential ribbed tubes with different rib dimensions have been determined experimentally. The data of ribbed tubes were compared with that of a plain tube. The experimental test section is a horizontal counter flow concentric tube heat exchanger with circumferentially ribbed inner tube. The ribbed tubes tested in this investigation have the ranges: circumferential depth from 0.5 to 1.5 mm and axial pitch distance from 5 to 15 mm. Water was used as the working fluid, where hot water flows in the inner tube and cold water flows in the annulus. The test runs are done at water flow rates ranging between 0.1 and 1.0 m3/h. The inlet cold and hot water temperatures are between 20 and 30 °C and between 40 and 60 °C, respectively. Comparison of experimental data of circumferentially ribbed tubes with smooth tube have shown that the heat transfer coefficient and pressure drop, quantified by means of Nusselt number and friction factor, are around 1.92 to 5.61 and 1.25 to 3.41 times higher than smooth tube depending on the circumferential geometric parameters and mass velocity of the working fluid. New correlations based on the data gathered during this work for predicting Nusselt number and friction factor for the circumferential ribbed tube heat exchanger have been proposed. The proposed correlations can predict the experimental data with average relative error of ± 6% for Nusselt number and ± 5% for friction factor..

تم حساب معامل انتقال الحرارة و هبوط الضغط لتدفق الماء داخل الانابيب المضلعة بشكل محيطي وبأبعاد تضليع مختلفة تجريبيا. بيانات الانابيب المضلعة تم مقارنتها مع تلك الخاصة بالأنبوب الناعم. ان مقطع الاختبار التجريبي هو عبارة عن مبادل حراري افقي متمركز الانبوب ومتعاكس الجريان مع انبوب داخلي مضلع بشكل محيطي. الانابيب المضلعة التي تم اختبارها في هذا البحث لها المديات الآتية: عمق ضلع محيطي من 0,5 الى 1,5 ملم وبعد محوري من 5 الى 15 ملم. استعمل الماء كمائع تشغيل، حيث يتدفق الماء الحار في الانبوب الداخلي و يتدفق الماء البارد في الانبوب الحلقي. ان التجارب المختبرية تم اجراءها بنسب تدفق ماء تتراوح بين 0,1 و 1,0 م3/ساعة. درجة حرارة الماء البارد والساخن تتراوح بين 20 الى 30 و40 الى 60 °م، على التوالي. مقارنة البيانات التجريبية للأنابيب المضلعة بشكل محيطي مع الانبوب الناعم توضح بان معامل انتقال الحرارة وهبوط الضغط، حددت كميا بواسطة رقم نسلت ومعامل الاحتكاك، حوالي 1,92 الى 5,61 و 1,25 الى 3,41 مرة اعلى من الانبوب الناعم معتمدة على شكل التضليع المحيطي والسرعة الكتلوية لمائع التشغيل. تم اقتراح معادلة ارتباط جديدة مستندة على البيانات التي تم جمعها في هذا العمل لحساب رقم نسلت ومعامل الاحتكاك لمبادل حراري ذو انبوب مضلع بشكل محيطي. ان معادلة الارتباط المقترحة من الممكن ان تحسب البيانات التجريبية بمعدل خطأ نسبي ±6% بالنسبة لرقم نسلت و±5% بالنسبة لمعامل الاحتكاك.-


Article
Experimental and Numerical Investigation to Evaluate the Performance of U-Longitudinal Finned Tube Heat Exchanger
تحقيق عملي ونظري لتقييم أداء مبادل حراري من نوع الأنبوب المزعنف بزعانف طولية على شكل حرف U

Loading...
Loading...
Abstract

Experimental and numerical investigation has been performed in this work to evaluate the performance for U-longitudinal finned tube heat exchanger. Four pairs of U-shaped longitudinal fins were selected and manufactured from copper material and welded on the straight copper tube. The inner tube is inserted inside insulated galvanized tube, sheet and roll insulation (arm flux) and glass wool have been utilized to cover inner and outer surface of galvanized tube for reducing heat losses. Air at various mass flow rates (0.03 to 0.07)kg/sec flows through annuli and de-ionized water at Reynold's numbers ranging from (270 to 1900) flows through the inner tube. Performance of (smooth and finned) tube heat exchanger was investigated experimentally. Experimental results showed (1.744 to 2.534) enhancement ratio when using U-longitudinal fins. Empirical correlations for air, water were represented by Nusselt's number. Numerical simulation has been carried out on present heat exchanger to analyze flow field and heat transfer using FLUENT package 14. The comparison between experimental work and numerical results showed good agreement.

في هذه الدراسة, تم انجاز تحقيق عملي وعددي لمبادل حراري من نوع الانبوب المزعنف بزعانف طولية علئ شكل حرف (U) من اجل دراسة اداءه الحراري. اربعة ازواج من الزعانف الطولية ذات شكل (U) تم تصميمها وتصنيعها من مادة النحاس وثبتت علئ انبوب نحاس الذي اولج داخل انبوب مصنع من مادة الكلفنايز ومعزول بعوازل من الداخل والخارج لتقليل الحرارة المفقودة. هواء عند معدلات تدفق كتلية تتراوح بين (0.03 الئ0.07 ) كغم/ثانية يجري خلال الفراغ الحلقي وماء منزوع الايونات ذو ارقام رينولدز تتراوح بين (270 الئ 1900) يجري خلال الانبوب الداخلي. اداء المبادل الحراري بالحالتين ( الاملس والمزعنف ) تمت دراسته. النتائج العملية بينت ان نسبة التحسين كانت (1.744 الئ 2.534) في حال استخدام المبادل الحراري ذو الانبوب المزعنف. علاقات تجريبية لجانب الهواء والماء تم تقديمها بدلالة رقم نيسلت. محاكاة عددية تم انجازها للمبادل الحراري لتحليل جريان المائع وانتقال الحرارة باستخدام البرنامج المتخصص 14ANSYS FLUENT. بينت المقارنة بين النتائج العملية والعددية وجود تطابق مقبول.


Article
Predication of A Mathematical Model for A Hardness in Steel-52100
التنبأ بالنموذج (الموديل) الرياضي للصلادة في الفولاذ نوع 52100

Author: Abbas Khammas Hussein عباس خماس حسين
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 5 Pages: 134-148
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This paper reports a research in which an attempt was made to predict a mathematical model of hardness for steel-52100 . The primary objective was to investigate the effect of heat treatment parameters on the hardness of steel-52100, where the value of hardness is influenced by these parameters (Austenitizing temperature, tempering temperature and tempering time) . To determine the influence of these parameters , experiments were conducted using Taguchi's orthogonal array . The results of these experiments were used to plot response graph , Pareto diagram and to calculate S/N ratios . An empirical model for the hardness in terms of the parameters mentioned was also developed . Coefficient of determination was used to check the adequacy and accuracy of the model . The empirical model so developed was checked by conducting confirmation experiments . Contour plots were plotted to visualize the effect of those heat treatment parameters on the hardness. Those parameters were optimized to maximize the hardness using the larger-the-better concept of robust design and also compared with the optimized parameters obtained using the developed empirical model . Finally, this study show a good agreement between the mathematical model and experimental results .

يتضمن هذا البحث محاولة للتنبأ بالموديل الرياضي لصلادة الفولاذ 52100 ، أما الهدف الرئيسي فإنه يتضمن دراسة تأثير عوامل المعاملة الحرارية على صلادة الفولاذ 52100 . حيث أن قيمة الصلادة يمكن أن تتأثر بهذه العوامل (درجة حرارة تكون الأوستينايت، درجة حرارة المراجعة ، و زمن المراجعة) . و لغرض تحديد تأثير هذه العوامل ، أجريت مجموعة من التجارب باستخدام مصفوفة تاكوجي . و قد استخدمت نتائج هذه التجارب لرسم مخطط الاستجابة، مخطط باريتو، و حساب نسبة الإشارة/الضبابية S/N ratio . كما تم الحصول على الموديل التجريبي الذي يعبّر عن العلاقة مابين الصلادة و عوامل المعاملة الحرارية . و تم استخدام معامل التحديد و للتحقق من كفاية و دقة الموديل الرياضي ، ومن ثم التحقق من ذلك الموديل التجريبي من خلال إجراء مجموعة من تجارب الإثبات (التأكيد) . و تم رسم الرسومات الكفافية (الكنتورية) لملاحظة تأثير عوامل المعاملة الحرارية على الصلادة . ومن ثم تم الحصول على العوامل المثلى التي يمكن من خلالها الحصول على القيمة القصوى للصلادة وفقاً لمفهوم جودة التصميم "الأكبر-الأفضل" و تم مقارنتها مع العوامل المثلى التي تم الحصول عليها من الموديل الرياضي . و أخيراً، أظهرت هذه الدراسة التطابق الجيد مابين نتائج الموديل الرياضي و النتائج التجريبية .


Article
USING OF GEOTHERMALENERGY (WELLWATER) FOR COOLING PURPOSE IN NAJAF TECHNICAL INSTITUTE (PART 1)
استخدام طاقة باطن الارض (مياه الابار) لاغراض التبريد في المعهد التقني / نجف (الجزء الاول )

Authors: Montadher A.Muhammed منتظر عبودي محمد --- AbdulkadhumJ.K.AL-Yasiri عبد الكاظم جعفر الياسري
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2014 Volume: 5 Issue: 2 Pages: 139-154
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

The industrial using of wells water in Iraq for buildings air conditioning are unknown or limited. So to state the benefits of this natural source an experimental and theoretical study in this field was established inorder to be funded by ministry of higher education to do larger cooling systems. The study concern on the ground water found in Najaf Institute which locate at Najaf sea south of Iraq. As a starting step the climate conditions was studied to determine the temperatures in a different periods of the year. The results proofed the benefits of temperature difference between the well water and the studying halls. Two studying halls were chosen, one of them used an air conditioner (capacity 2 ton) ,the other used well water cooling system. The temperature difference between two halls were taken ,as well as, the electricity consuming. A theoretical –experimental procedure was used to make design of cooling system. The heat load for the hall ,temperatures and velocity of water and air were measured.

ان الاستخدام الصناعي للمياه الجوفيه في العراق لاغراض تكييف البنايات لاتزال جدا محدودة الاستخدام,ولبيان اهميه هذا المصدر الطبيعي في باطن الارض اجريت دراسه تحضيريه وتجريبية لتوضيح فائدة هذه المياه في مجال التبريد وتمهيدا لتمويلها من قبل دائرة البحث والتطوير في وزارة التعليم العالي والبحث العلمي لعمل منظومات اكبر.تركز البحث على دراسه المياه الجوفيه في المعهد التقني/نجف الواقع على منطقه بحر النجف جنوب العراق حيث تم دراسه الظروف المناخيه كبدايه شملت قياس درجات الحراره في اوقات مختلفه من السنة.اظهرت النتائج امكانية الاستفادة من فروقات درجات الحرارة بين مياه البئر والتي تعد ثابتة على مدار العام وبين القاعات الدراسية المراد تبريدها,حيث تم استهداف قاعتين بهذا البحث احدهما تم وضع منظومة تبريد باستخدام مياه الابار والاخرى تم وضع اجهزة تكييف باستخدام طاقة الكهرباء حيث سيتم اخذ الفروقات في درجات الحرارة بين القاعتين اضافة الى استهلاك الطاقة. تم استخدام اسلوب نظري وعملي لغرض تصميم المنظومة حيث تم حساب الحمل الحراري الاساسي للقاعة اضافة الى اجراء قياسات عملية لدرجات حرارة وسرعة جريان الماء والهواء .

Keywords

Geothermal --- Heat Load --- Cooling --- Water Well


Article
The Effect of Different Types of Separating Medium On The Hardness of Different Types of Heat-Cure Acrylic Resin Materials

Author: Nihad Hasan Mohammed
Journal: Medical Journal of Babylon مجلة بابل الطبية ISSN: 1812156X 23126760 Year: 2014 Volume: 11 Issue: 3 Pages: 590-598
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In the present study evaluation of the effect of different types of separating medium on the hardness of hot-cure acrylic resin material cured by water path conventional method and microwave curing method .Forty specimens of hot-cure acrylic resin were fabricated in order to provide an standardized dimensions of tested specimens (65mmx50mmx2.5 ±0.03mm) length, width and depth respectively∙ these specimens were invested by either cold mold seal or glycerin separating medium ∙(40) specimens were used in this study, divided into four main groups according to the type of separating medium and curing technique used (ten specimen for each group);were as follows:Group A: Specimens lining with cold mold seal separating medium (C∙M∙S)(control group) cured by water bath device∙Group B: Specimens lining with glycerin separating medium (G) cured by water bath device∙Group C: Specimen lining with cold mold seal separating medium (C∙M∙S) cured by microwave device∙ Group D: Specimens lining with glycerin separating medium (G) cured by microwave device∙ The result of this study indicated a significant difference between groups(p<0.05) in ANOVA test and heat-cure acrylic cured by water bath that lining with glycerin have a high mean value in comparison to another tested groups and heat-cure acrylic cured by microwave that lining with glycerin have a lower mean value in comparison to another tested groups .From this study we can concluded that glycerin is safely separating medium that can be used in dental laboratory because it is less cost and gives good mechanical properties when used with acrylic denture base materials.Also we can conclude that the type of packing or curing method affects the hardness of heat-cure acrylic resin.

في الدراسة الحالية تم استخدام نوعين مختلفين من الوسيط العازل لتأثير قوة الصلادة لمادة (الاكريلك الحار ) المعالج في طريقتي طبخ مختلفتين وهي بخار الماء التقليدي والطبخ بالمايكروويف الحراري . تم جمع أربعون عينة مربعة الشكل من الاكريلك الحار المعالج لغرض توفير أبعاد قياسية لأنواع(مفحوصة ذات طول وعرض وسمك ) 65mmx50mmx2.5±0.03mm)) هذه المربعات يتم تغميسها إما في الوسيط العازل(C.M.S) أو (G.) هذه الأنواع الأربعون تم تقسيمها إلى اربع مجموعات رئيسية حسب نوع الوسيط العازل المستخدم و حسب نوع جهاز الطبخ المستخدم (10عينات لكل مجموعة رئيسية ) كما يلي : المجموعة الأولى (A): أنواع مبطنة بوسيط عازل (Cold mold seal ) طبخت العينات الاكريليكة باستخدام بخار الماء و المجموعة الثانيةB)): أنواع مبطنة بوسيط عازل (Glycerin) طبخت العينات الاكريليكة باستخدام بخار الماء والمجموعة الثالثة (C): أنواع مبطنة بوسيط عازل (Cold mold seal ) طبخت العينات الاكريليكة باستخدام المايكروويف اما المجموعة الرابعة (D): أنواع مبطنة بوسيط عازل (Glycerin )طبخت العينات الاكريليكة باستخدام المايكروويف.أظهرت النتائج في هذه الدراسة بان الكليسيرين هو أفضل مادة عازلة مستخدمة نتيجة لأفضل النتائج في فحص الصلادة التي تم الحصول عليها عند استخدام صوديوم ختم القالب كمادة عازلة للمجموعة القياسية علاوة على ذلك ليس هناك أي تغير في التركيب الكيميائي لعينات الراتنج الاكريلي المبلمر الحار بطريقتي الطبخ نتيجة لاستعمال الكليسيرين كمادة عازلة ولان مادة الكليسيرين سهلة الحصول والاستخدام ومتوفرة ورخيصة فأن استعمالها الراتنج الاكريلي المبلمر الحار كمادة عازلة يعطي نتائج افضل .


Article
Experimental and Numerical Investigation to Enhance the Performance of Helical Coiled Tube Heat Exchanger by Using Turbulators
دراسة عملية وعددية لتحسين أداء مبادل الحراري ذو أنبوب ملتف حلزوني باستخدام العوائق

Loading...
Loading...
Abstract

In the present work, numerical and experimental investigation is carried out to evaluate the performance of helical coiled tube heat exchanger with wire coil insert. Experimental work included design of wire coiled and inserted into a vertically positioned plain copper helical tube heat exchanger. The effects of wire coil insert with different parameters on heat transfer and friction loss in the helical tube were examined with Dean number ranging from 700 to 2000.The experiments of coiled wire were performed, firstly with three different pitches (P= 15, 20 and 30)mm with constant circular cross section(a=1mm), secondly with different cross section (circular and square) at constant pitch 15mm, and thirdly with two different square wire thickness (a =1, 2) mm at constant pitch 15mm. The numerical analysis was carried out to simulate the flow and heat transfer in a helical coil tube with wire coil insert at pitch (15mm) with different flow rates by using ANSYS FLUENT package 14.0. The experimental results showed that the use of tubular leads to a considerable increase in heat transfer and friction loss over those of a smooth coiled tube. The Nusselt number increases with the increasing of Dean number and the reduction in pitch for wire coils. The coiled square wire provides higher heat transfer than the circular one under the same conditions. A new empirical correlations have been developed to predict Nusselt number of the helical coil heat exchanger. Also the comparisons between numerical and experimental results show good agreement.

في البحث الحالي دراسة عددية وعملية لتقييم اداء مبادل حراري ذو انبوب حلزوني بداخله سلك حلزوني شبيهه بالنابض كأداة محسنة لانتقال الحرارة ومقارنة أداؤها في الأنابيب مع الأنابيب الملساء. شمل العمل التجريبي تصميم سلك ملفوف وضع داخل أنبوب حلزوني موضوع بشكل عمودي تم دراسة تأثير أبعاد مولد الدوامات على انتقال الحرارة ومعامل الاحتكاك ضمن رقم دين (700 -2000) .تم اجراء الاختبارات عند متغيرات عديدة للسلك الحلزوني(مولد الدوامات),اولا عند استخدام سلك ذو مقطع دائري بثلاثة ابعاد مختلفة من الخطوة (15و20و30 p=)ملم, ثانيا عند استخدام سلك بمقطعين (دائري ومربع)لخطوة ثابتة(p=15mm)وثالثا عند استخدام سلك ذو مفطع مربع بطول ضلع a=1,2mm))لخطوة ثابتة قدرها((p=15mm.تضمن الجانب العددي نمذجة لسلوك الجريان وانتقال الحرارة للمبادل الحراري باستخدام برنامج حاسوبيANSYS FLUENT 14))لتحديد تأثير السلك الحلزوني بخطوة ثابتة ((P=15mm أظهرت النتائج التجريبية أن استخدام مولدات الدوامة يؤدي إلى زيادة كبيرة في نقل الحرارة وفقدان الاحتكاك اكثر من تلك أنبوب الحلزوني الاملس . يزداد عدد نسلت مع زيادة عدد دين ونقصان الخطوة للسلك الحلزوني. لقد بينت المقارنة بين النتائج العملية والنظرية حصول تطابق جيد بينهما. طورت معادلة تجريبية لتوقع عدد ناسلت لأنبوب حلزوني مع إضافة السلك الحلزوني بالداخل.


Article
Effect of Quenching Media on the Mechanical Properties and Abrasive Wear Resistance of (34Cr4) Steel Blade with Soil Texture Used in Agricultural Equipments
تأثير وسط التقسية على الخواص الميكانيكية ومقاومة البلى الحكي لريش فولاذ (34Cr4) مع نسجة التربة والمستخدمة في المعدات الزراعية

Author: Abbas S. Alwan
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 9 Part (A) Engineering Pages: 2205-2215
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this paper, a study the effect of quenching media on the mechanical properties and abrasive wear has been done on steel blade (34Cr4) for agriculture equipment with soil texture. It has found that heat treatment technique is promising to improve the quality of agriculture equipments and components working in soil under dry conditions. Abrasive wear resistance is very important in many applications and it is directly correlated with hardness of metal surface. The heat treatments have large role to alter the mechanical properties and wear resistance of steel type (34Cr4). It was found that the wear resistance increases with increase hardness which increases with varying quenching media as follows; 38HRC, 56.6 HRC, 58.3 HRC and 60.6 HRC for as – received sample, caustic Soda (10%), engine oil and flaxseed oil respectively. It was found also that the wear resistance increases with decreasing toughness to values 48.3 J, 45 J, 40.2 J and 27J respectively. Wear was presented on the worn surfaces of the steels which were used in this work. All mechanical properties depended on microstructure which consists of martensitic structure and some amount of carbide particles.

في هذا البحث, تم دراسة تأثير وسط التقسية على الخواص الميكانيكية ومقاومة البلى الحكي لريش فولاذ ( 34Cr4 ) المعدات الزراعية المستخدمة مع نسجة التربة. وجد ان تقنية المعاملات الحرارية هي المسؤولة في تحسين نوعية الاجزاء والالات الزراعية في العمل بالترب في ظروف جافة. وتكون مقاومة البلى الحكي مهمة في تطبيقات كثيرة وهي ذات علاقة مباشرة مع صلادة سطح المعدن. ان المعاملات الحرارية لها دور كبير في تغيير الخواص الميكانيكية ومقاومة البلى لفولاذ نوع ( 34Cr4 ) . حيث وجد ان مقاومة البلى تزداد مع زيادة الصلادة باختلاف وسط التبريد مثل:, 60.6 HRC, 58.3 HRC, 56.6 HRC, 38HRCلاوساط تمثل بدون معاملات, لصودا 10%, زيت المحركات و زيت الكتان على التوالي. وجد كذلك ان مقاومة البلى تزداد عند نقصان قيم العساوة للمعدن عند قيم48.3 J , 40.2 J, 45 J 27J, وهي قيم طاقة الصدمة بمقياس شاربي تمثل عينات بدون معاملات , لصودا 10% , زيت المحركات و زيت الكتان على التوالي. ظهور البلى على سطوح الفولاذ البالية (التالفة) المستخدم في هذا العمل. كل الخواص الميكانيكية تعتمد على البنية المجهرية والتي تتكون من البنية المارتنسايتية وقليلا من حبيبات كاربيدية.

Listing 1 - 10 of 61 << page
of 7
>>
Sort by
Narrow your search

Resource type

article (61)


Language

English (44)

Arabic (8)

Arabic and English (8)


Year
From To Submit

2014 (61)