research centers


Search results: Found 11

Listing 1 - 10 of 11 << page
of 2
>>
Sort by

Article
Numerical Analysis of the Effect of Scanning Speed on the Temperature Field Distribution for Laser Heat Treatment Applications

Author: Furat I. Hussein Al-Najjar
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2018 Volume: 21 Issue: 2 Pages: 213-222
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

One of the unique properties of laser heating applications is its powerful ability for precise pouring of energy on the needed regions in heat treatment applications. The rapid rise in temperature at the irradiated region produces a high temperature gradient, which contributes in phase metallurgical changes, inside the volume of the irradiated material. This article presents a comprehensive numerical work for a model based on experimentally laser heated AISI 1110 steel samples. The numerical investigation is based on the finite element method (FEM) taking in consideration the temperature dependent material properties to predict the temperature distribution within the irradiated material volume. The finite element analysis (FEA) was carried out using the APDL scripting language (ANSYS Parametric Design Language) that is provided by the commercial code ANSYS. Infrared (IR) thermography technique was used to explore the workpiece surface and to validate the obtained results. The work takes into account the effect of different speeds of the laser beam and pulses overlap on the temperature pattern of the material surface and depth.


Article
Effect of High Temperature on Mechanical Properties of Rubberized Concrete Using Recycled Tire Rubber as Fine Aggregate Replacement

Authors: Wrya A. Abdullah --- Mohamed R. AbdulKadir --- Muhammad A. Muhammad
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 8 Part (A) Engineering Pages: 906-913
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Effects of various elevated heating temperatures on mechanical properties of normal concrete containing recycled tire rubber as a fine aggregate (RTRFA) has been investigated in this paper. Five different concrete mixes were prepared in the laboratory. In each mix Ordinary Portland Cement, natural coarse and fine aggregate, water and RTRFA are used with fine aggregate replacement ratios (0%, 6%, 12%, 18% and 24%) by weight. In the laboratory, 60 cylindrical specimens (100mm diameter × 200mm high) and 60 cubic specimens (150×150×150mm3) were prepared. The concrete specimens were exposed to four different heating temperatures: Control (Not heated), 200, 400, and 600°C, and tested according to British standards to observe the post-heating mechanical properties. These properties included density and mass loss, split tensile strength and compressive strength. The results showed a linear decrease in compressive strength with higher temperature degrees and percent replacement of fine aggregate by RTRFA. Moreover, the concrete’s tensile strength fluctuated as it increased at 6% of rubber replacement then linearly declined at further replacement rates. Finally, some crucial conclusions of heating rubberized concrete have been drawn.


Article
EXPERIMENTAL STUDY OF SOLAR CHIMNEY PERFORMANCE FOR PASSIVE HEATING
دراسة تجريبية لأداء المدخنة الشمسية للتدفئة السلبية

Loading...
Loading...
Abstract

An experimental investigation on solar chimney used for heating under climate of Iraq is carried out. Experiments were conducted on the chimney installed on vertical wall with absorber plate placed at the front side of the air gap. The solar chimney attached to room of dimensions (2.5×1.29×1.07) m. The chimney is studied to measure the effect of the air gap width with constant height of (1.07 m). Three widths are tested, namely, 0.2 m, 0.3 m and 0.4 m. The experimental results showed that the solar chimney can achieve about (13 °C) difference in temperature between indoor and outdoor as well as it gives acceptable difference in partial cloudy days. The results also indicated that the best performance of solar chimney is with 0.3m air gap width.

اجريت دراسة عملية على مدخنة شمسية تستخدم للتدفئة في المناخ العراقي. نفذت التجارب على مدخنة مثبتة على الجدار العمودي وتم وضع السطح الماص على الجانب الامامي لفجوة الهواء. المدخنة الشمسية مركبة لغرفة بابعاد (2.5م ×1.29م × 1.07م). من اجل دراسة تاثيرعرض فجوة هواء المدخنة مع ارتفاع ثابت لثلاثة اعراض تم اختبارها وهي 0.2 متر و0.3 متر و 0.4 متر اظهرت النتائج التجريبية ان المدخنة الشمسية يمكن ان تحقق 13 درجة مئوية فرق في الحرارة بين الداخل والخارج فضلآ عن انه تعطي فرق مقبولآ بالفرق في درجة الحرارة في الايام الغائمة جزئيآ واشارت النتائج ايضآ الى ان افضل اداء للمدخنة الشمسية هو مع 0.3 متر عرض فجوة هواء.


Article
Effect of Using External Packaging Materials for New Building Walls on Heating Load
دراسة تأثير استخدام مواد التغليف الخارجي للجدران الداخلية في الابنية الحديثة على حمل التدفئة

Authors: Hassan Kareem Abdullah حسن كريم --- Sajjad Shakir Ali سجاد شاكر
Journal: Wasit Journal of Engineering Sciences مجلة واسط للعلوم الهندسية ISSN: 23056932 Year: 2018 Volume: 6 Issue: 2 Pages: 28-37
Publisher: Wassit University جامعة واسط

Loading...
Loading...
Abstract

Experimental and theoretical investigation of three types of external packaging materials (Gypsum board, Alucobond, Ceramic) for the residential building were carried out in the present work, to reduce heating load in winter. Experiments were carried out at the university of Wasit (Al-Kut city, late 32.5N), winter season by building small room from sandwich panel. The room's dimensions were 2m width, 2m length and 2.4m height. The south wall was made two slots. The slot dimensions are 0.3m width and 1m height. Two types of walls were built in the two slots. The first wall was built from common bricks. The second wall was built from bricks covered with packaging material. The radiant time series (RTS) method was used for calculating the experimental heat losses through the walls. The ESP-R program from Energy Systems Research Unit (ESRU) - University of Strathclyde used to calculate the theoretical results[1]. It is the intensity of the radiation and temperature on the walls. The results of the experimental work show that the maximum values of percentage energy saving as follows: External packaging materials; 16.77% Gypsum board,2.73% Alucobond and 2.3% Ceramic

أجريت دراسة عملية ونظرية لثلاثة انواع من مواد التغليف لجدران الخارجية(الواح جبسية، الوكوبوند، سيراميك) للابنية السكنية الحديثة لتقليل حمل التدفئة. أجريت التجارب في جامعة واسط (مدينة الكوت خط عرض 32.5 شمال)، في فصل الشتاء ببناء غرفة صغيرة بقياس 2م طول * 2م عرض * 2.4م ارتفاع من السندويج بنل. شق في الجدار الجنوبي فتحتيين. ابعادها هي 1م ارتفاع* 0.3م عرض في كل فتحة بني جدار. الجدار الاول بني من الطابوق. الجدار الثاني بني من الطابوق تم تغليفة بأنواع مختلفة من مواد التغليف. برنامجESP-R من وحدة الطاقة نظم البحوث (ESRU) – جامعة ستراثكلايد تستخدم لحساب النتائج النظرية. هي شدة الإشعاع و درجة الحرارة على الجدران [1]. حسب فقدان الحرارة عمليا باستخدام السلاسل الزمنية (RTS) . اظهرت نتائج العمل التجريبي ان القيم القصوى من نسبة توفير الطاقة على النحو التالي: مواد التغليف الخارجي :16.77% الواح جبسية و 2.73% الوكوبوند و 2.3% سيراميك.


Article
Analysis of Heat Transfer on Peristaltic Transport of Powell- Eyring Fluid in an Inclined Tapered Symmetric Channel with Hall and Ohm's Heating Influences
تحليل انتقال الحرارة للانتقال الموجي لمائع باول- ايرنك خلال قناة متناضرة مائلة ومدببة مع تأثيرات هول وأوم الحرارية

Authors: Hayat A. Ali حياة عادل علي --- Ahmed M. Abdulhadi احمد مولود عبدالهادي
Journal: Journal of Al-Qadisiyah for Computer Science and Mathematics مجلة القادسية لعلوم الحاسوب والرياضيات ISSN: 20740204 / 25213504 Year: 2018 Volume: 10 Issue: 2 Pages: 26-41 Math
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

In this paper, we present an analysis of heat transfer on peristaltic flow for Powell- Eyring fluid in an inclined symmetric tapered channel is discussed. Hall effect, velocity, thermal slip conditions, and Ohm's heating are taken into consideration. The governing equations for the balance of mass, momentum and energy are modeled, and then simplified by holding the consideration of long wavelength and low Renolds number approximation. Graphical results are given to analyze the behavior of the parameters emerging in the problem. Effect of Hall parameter and Hartman number on velocity axial have opposite characteristics.

في هذا البحث, ناقشنا مبدأ انتقال الحرارة في الجريان الموجي لمائع باول- ايرنك ضمن قناة مدبب متماثل ومائل. اخذا بنظر الاعتبار تاثير هول, وشرطي الانزلاق للسرعة والحرارة وكذلك تاثير اوم. معادلات الحاكمة لموازنة الكتلة ,الحركة والطاقة تم صياغتها ومن ثم تبسيطها اعتمادا على تقريب كبر طول الموجة وصغر عدد رينولد. اخيرا النتائج الصورية اعطيت لتحليل سلوك المتغيرات الوسطية المستجدة في المسالة وقد لوحظ ان تاثير متغير هول وعدد هارتمن يمتلكان خصائص متعارضة على محور السرعة.


Article
Calculation of Daily Cooling Degree for Selected Stations in Iraq
حساب درجة التبريد اليومية لمحطات مختارة في العراق

Authors: Mohammed M. Ahmed محمد مجيد احمد --- Omar L. Khaleed عمر ليث خالد --- Nagham T. Ibraheem نغم ذاري ابراهيم
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2018 Volume: 14 Issue: 4 Pages: 26-39
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Cooling degree days (heating) are most important and simplest coefficients that are used in assessment of energy consumption process in buildings and residential complexes through heating and cooling processes. In this study, cooling degree days were calculated in (33) stations in Iraq by using of daily temperature data from National Aeronautics and Space Administration (NASA) through Surface Meteorology and Solar Energy Project (SMSE) from (1983-2005). This study used hourly cooling degrees method; the results show that there are real values for this parameter during nine months in Iraq from March to November and at an annual rate between (513) degrees in northern Iraq Amadiyah station and (3278) degrees in southwestern Iraq Samawah station. The highest values of this parameter were found during July while the lowest values were found during March, as the results showed that the highest values are in the southern regions of western and southern Iraq while the lowest values are in the northern and north-eastern regions of Iraq in all months of the year.

تعتبر معاملات ايام درجة التبريد (التدفئة) Cooling Degree-Days من اهم وابسط المعاملات المستخدمة في تقييم عملية استهلاك الطاقة في البنايات والمجمعات السكنية من خلال عمليتي التبريد او التدفئة. تم في هذه الدراسة حساب ايام درجة التبريد في (33) محطة في العراق باستخدام بيانات درجة الحرارة اليومية وللفترة الزمنية (1983-2005) والمتوفرة في الموقع الرسمي لوكالة ناسا الفضائية من خلال مشروع (SMSE). اذ تم استخدام طريقة ساعات درجات التبريد، حيث اظهرت النتائج وجود معدلات حقيقية لهذه المعامل خلال تسعة اشهر من السنة في العراق تمتد من شهر اذار الى تشرين الثاني وبمعدل سنوي يتراوح مابين (513) درجة في محطة العمادية شمال العراق و (3278) درجة في محطة السماوة جنوب غرب العراق. وقد كانت اعلى القيم خلال شهر تموز في حين ظهرت اقل القيم خلال شهر اذار، كما اظهرت النتائج ان اعلى القيم تكون في المناطق الجنوبية والجنوبية الغربية من العراق بينما اقل القيم تكون في المناطق الشمالية والشمالية الشرقية من العراق ولجميع اشهر السنة.


Article
Thermal changes and their effect along the heating and cooling periods in the cities of Dohuk governorate
التغيرات الحرارية واثرها على طول فترات التدفئة والتبريد في مدن محافظة دهوك دراسة في المناخ التطبيقي

Author: Faten Khalid Abdulbaqi فاتن خالد عبد الباقي
Journal: Journal of Research Diyala humanity مجلة ديالى للبحوث الانسانية ISSN: 1998104x Year: 2018 Issue: 75-1 Pages: 420-449
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Climate change is one of the most environmental phenomena affecting human activity through its effect on the deviation of climatic elements from their natural course, especially temperature in time and place, The increase in temperature rise in urban centers and urban gatherings such as Dohuk, Akri, Amadi, Zakho and Simil, Due to industrial, technological and urban development contributed to the increase in consumption of electric power significantly, They vary between urban centers, Where the length of periods of need for electricity for heating or cooling purposes varies depending on the location of latitude and according to the city elevation, since the elevated cities in which the temperature drops in winter which contributes to increased the consumption of electricity for heating purposes compared to the summer season in these areas, As it differs from low-lying areas where temperatures rise in summer which required increase in electricity consumption.These cases need to be studied and researched in order to rationalize electricity consumption in cities and urban communities and to rebalance energy consumption, development and sustainability.

تعد التغيرات المناخية من اكثر الظواهر البيئية تاثيرا على نشاط الانسان وذلك من خلال تأثيرها على انحراف العناصر المناخية عن مسارها الطبيعي وخصوصا درجات الحرارة زمنيا ومكانيا،فالتزايد بارتفاع درجات الحرارة في مراكز المدن والتجمعات الحضرية كمدينة دهوك وئاكري والعمادية و زاخو وسيميل وبه رده رش بسبب التطور الصناعي والتكنلوجي والعمراني اسهم في ازدياد استهلاك الطاقة الكهربائية بشكل كبير، وهي متباينة بين المراكز الحضرية،حيث يتباين طول فترات الحاجة للطاقة الكهربائية لأغراض التدفئة او التبريد حسب الموقع من دوائر العرض وحسب ارتفاع المدينة عن مستوى سطح البحر،فالمدن المرتفعة تنخفض فيها درجات الحرارة شتاءا مما يسهم بإزدياد استهلاك الطاقة الكهربائية لأغراض التدفئة مقارنة بموسم الصيف لهذه المناطق ،كما انها تختلف عن المناطق المنخفضة والتي ترتفع فيها درجات الحرارة صيفا مما يستدعي ازدياد استهلاك الطاقة الكهربائية، فاستوجبت هذه الحالات الدراسة والبحث لغرض ترشيد استهلاك الطاقة الكهربائية في المدن والتجمعات الحضرية واعادة التوازن في استهلاك الطاقة وتنميتها واستدامتها.


Article
Bending , Heating and Pressure Effects of He-Ne Laser in Single Mode Fiber

Authors: Nizar Salim Shnan --- Lubna Abbas Muhammad
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 1 Pages: 209-219
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper a single mode fiber have been chosen with a refractive index (1.50) to the core, and (1.485) to the cladding, with length of (2 m). It was exposed this optical fiber to a bending with different diameters, and to a different temperatures as well as pressure due to putting different weights to study dispersion phenomenon which affects on a pulse shape that travels in optical fiber. Experimental results explain when a bending diameter for an optical fiber increases it will decrease the dispersion and pulse shape will approximate from a Gaussian shape , and the increasing in temperature will increasing the attenuation in the pulse transfer through the optical fiber . But when increasing pressure, the dispersion will increases and the pulse shape will be distorted.

في هذا البحث تم استخدام ليف بصري احادي النمط بمعامل انكسار ( 1.50 ) للب و( 1.485 ) للغلاف وبطول (2m). تم تعريض هذا الليف البصري الى انحناءات بأقطار مختلفة وايضا درجات حرارة متغيرة, وكذلك ضغط من خلال وضع اوزان مختلفة, ودراسة ظاهرة التشتت التي تؤثر على شكل النبضة المنتقلة داخل الليف البصري, ومن خلال النتائج العملية تبين انه عند زيادة قطر الانحناء لليف البصري يقل التشتت ويقترب شكل النبضة من الشكل الكاوسي. وكذلك عند زيادة درجة الحرارة تحصل زيادة في توهين النبضة المنتقلة خلال الليف البصري , اما عند زيادة الضغط سوف يزداد التشتت ويحصل تشوه في شكل النبضة.


Article
An Experimental Study of the Thermal Performance of Solar Air Collector Inclined (75o) on the Horizontal Plane

Author: Hasasn Ali Jurmut
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 3 Pages: 228-235
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper, an experimental study of the thermal performance of the solar air collector manufactured of galvanized iron sheet with dimension 100×120cm, frame width 20cm, has holes 0.5cm arrangement on horizontal and vertical, the collector inclined at an angle (75o) on the horizontal plane. All author faces of the collector (four sides and background) are insulations in order to minimize the thermal losses .All the result recorded in winter season for two different days one of them sunny and the other was cloudy. The result shows the effect of the angle of collector gives more heat to the collector, hence higher outlet temperature, especially in sunny day. Maximum outlet temperature of the collector (35.5o when inlet temperature 18o) and maximum Nusselt number(Nu) at twelve o’clock of the sunny day more than the cloudy day. At the end its high system efficiency and good collector effectiveness.

تمت في هذا البحث دراسة عمليه للأداء الحراري لجهاز مجمع الهواء الشمسي المصنع من صفائح الحديد غبر المغلون وبأبعاد ) 100 × 120 سم ( ، وعرض الإطار 20 سم، وبثقوب 0.5 سم مرتبة افقيا ورأسيا، والمجمع يميل بزاوية (( 75o على المستوى الأفقي. جميع الجوانب الاخرى من الجامع (أربعة جوانب والخلفية) هي معزولة حراريا من أجل تقليل الخسائر الحرارية . جميع القراءات تمت في فصل الشتاء لمدة يومين مختلفين واحد منهم مشمس والآخر كان غائما. واظهرت النتائج تأثير زاوية ميل المجمع بامتصاصه مزيدا من الحرارة ، وبالتالي ارتفاع درجة الحرارة الخارجة، وخاصة في اليوم المشمس اعلى اعظم درجه خارجة من المجمع (35.5 درجه عندما تكون درجة حرارة المحيط 18 درجة مئوية), اعلى (Nu) في الساعة الثانية عشرة من اليوم المشمس أكثر من اليوم الغائم. واخيرا كفاءة عالية وفعالية جيدة للمجمع الشمسي.


Article
Carrier Temperature In Quantum Dot Optical Amplifiers

Authors: Kadhem A. Kadhem --- Ahmed H. Flayyih
Journal: Journal of Education for Pure Science مجلة التربية للعلوم الصرفة ISSN: 20736592 Year: 2018 Volume: 8 Issue: 3 Pages: 151-160
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

AbstractThe effect of increasing of carrier temperature in wetting layer of semiconductor optical amplifier hasbeen modeling. The occupation probability, carrier heating relaxation, spontaneous emission and freecarrier absorption have been included in our formalization. The numerical calculations showed theoccupation probability directly proportion with carrier heating time as a result of reduction of carrierdensity in wetting layer. Also, the reservoir carrier temperature is directly proportional with the fullwidth at half maximum of injected pulse and carrier heating lifetime. The numerical calculations thatare showed; the carrier heating in the rate equations satisfies the thermal equilibrium between thelattice and carriers.

Listing 1 - 10 of 11 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (11)


Language

English (9)

Arabic (1)

Arabic and English (1)


Year
From To Submit

2018 (11)