research centers


Search results: Found 72

Listing 11 - 20 of 72 << page
of 8
>>
Sort by

Article
Effect of Chromium on Growth of green ALGA SCENEDESMUS QUADR ICAUDA (TURP.) DE BERB. With increase of nitrogen concentration
تأثير عنصر الكروم في نمو الطحلب الاخضرScenedesmus quadricauda (Turp.) de Breb.عند زيادة تركيز النيتروجين

Author: Altaf Abid alwhed Al- Rawi ألطاف عبد الواحد عيسى الراوي
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2010 Volume: 7 Issue: 2 Pages: 910-917
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The study was conducted to identify the toxicity of chromium on scenedesmus quadricauda algae alone and in the presence of nutrient metal (Nitrogen). Different concentrations of chromium (0.5, 1.5 , 2.5, 3.5 , 4.5mg/L) were used and the presence nitrogen is (5 ,10 ,50 ,100mg/L) on cultur media(chu-10) with used for cultivation of the algae in controlled conditions(25oC , light intensity 380 –E/m2 /s. The results showed increasing in the toxicity of the metal when is alone , excess of concentrations an time of exposure. The growth rate decreased from 0.44 to 0.06 cell/ hour after 12 day of the biging of the experiment and of concentrate 4.5 mg/L of chromium. The intermediate active concentrations of the chromium(EC50) was increased after 96 hours from the exposure, which it reached alevel at 3mg/L, which the increase of rate of inhibition which became 64, 80, 87 and 90% respectively with above mentioned concentrations of chromium. While after increasing the nitrogen concentrations in the culture media , an decrease was detected in the toxicity of the chromium at 3mg/L . Level through the increase in growth rate reached 0.30 cell /hour after the addition of 5mg/L of Nitrogen to the culture media which contain 3mg/L of chromium. This increase was also a companied by a decrease in rate of inhibition at a level of 74%, 69%, 78%, 70% respectively with the above mentioned treatment concentrations. From the above results it could be concluded that the toxicity of chromium may be declined under the effect of the Nitrogen

تضمنت الدراسة التعرف على سمية عنصر الكروم في الطحلب S. quadricauda بصورة منفردة واخرى بوجود تراكيز مضافة من العنصر المغذي (النتروجين) . استخدمت تراكيز مختلفة من الكروم (0.5, 1.5, 2.5, 3.5, 4.5 ملغم / لتر) والنتروجين (5, 10, 50, 100 ملغم / لتر) اضيفت الى الوسط الزرعي Chu – 10 الذي استخدم لاستزراع الطحلب في ظروف مسيطر عليها (درجة الحرارة 25ºم وشدة الإضاءة 380 مايكرواينشتاين / م2 / ثا). وقد أظهرت النتائج ان سمية عنصر الكروم تزداد بزيادة تركيزه وطول المدة التي يتعرض الطحلب لها ، فعند تركيز 4.5 ملغم / لتر من الكروم انخفض معدل نمو الطحلب من 0.44 الى 0.06 خلية/ ساعة وبعد 12 يوماً من بداية التجربة . وبعد (96) ساعة من التعريض للعنصر ازداد تركيز المتوسط الفعال للعنصر (EC50) وبلغ 3 ملغرام/ لتر رافقته زيادة في معدلات التثبيط التي بلغت 64% و 80% و 87% و 90% على التوالي مع التراكيز المذكورة سابقاً في عنصر الكروم . اما عند زيادة تراكيز العنصر المغذي (النتروجين) في الوسط الزرعي فقد لوحظ انخفاض في سمية عنصر الكروم عند التركيز 3 ملغم / لتر من الكروم إذ كانت هنالك زيادة في معدل نمو الطحلب عند اضافة النتروجين بتركيز 5 ملغم/ لتر الى الوسط الزرعي الذي يحتوي عنصر الكروم بتركيز 3ملغم/ لتر ، فقد بلغ معدل النمو 0.30خلية / ساعة رافق هذه الزيادة انخفاض في معدلات التثبيط إذ سجلت بعد 96 ساعة من التعريض للتراكيز المختلفة من النتروجين والمذكورة سابقاً 74% و 69% و 78% و 70% و 69% على التوالي وقد رافق هذا كله زيادة كثافة الخلايا وبشكل ملحوظ مما يعطي مؤشراً على تقليل سمية عنصر الكروم بوجود النتروجين .


Article
Hard Chromium Electroplating and Improvement the Properties by the Thermo Chemical Treatments (Solid Carburizing) of Low Carbon Steel
الطلاء الكهربائي بالكروم الصلد وتحسين الخواص بالمعاملات الحرارية الكيمياوية (الكربنه الصلبة) لفولاذ منخفض الكاربون

Authors: Ahmed Salloum Abbas أحمد سلوم عباس --- Amin Dway Thamir أمين دواي ثامر --- Muna Khedier Abbas منى خضير عباس
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2009 Volume: 5 Issue: 4 Pages: 99-114
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research the hard chromium electroplating process, which is one of the common methods of overlay coating was used, by using chromium acid as source of chromium and sulphuric acid as catalyst since the ratio between chromic acid and sulphuric acid is (100 : 1) consequently. Plating process was made by applying current of density (40 Amp / dm2) and the range of solution temperature was (50 – 55oC) with different time periods (1-5 hr). A low carbon steel type (Ck15) was used as substrate for hard chromium electroplating. Solid carburization was carried out for hard chromium plating specimen at temperature (925oC) with time duration (2 hr) to be followed with quenching and tempering. The phase analysis was conducted by using X– ray diffraction. The examination results show that the chromium carbides in plating layer were (Cr23C6, Cr7C3). The microhardness of hard chromium plating specimen was measured, and the results show that the high hardness was about (907HV). After solid carburization the hardness values increase and the results show that the higher hardness for chromium plating layer on low carbon steel surface was (1276 HV). Wear apparatus type (Pin on Disc) was used to study dry sliding wear properties of low carbon steel (As received) and hard chromium plating specimens and solid carburized. The effect of applied normal load on wear rate was studied with weighting method using five normal loads (5, 10, 15, 20, 25 N) at constant sliding speed (2.198 m / sec). The results reveal that the wear rate increases with the increasing of applied normal load. A good improvement in wear resistance was noticed for hard chromium plating specimens as compared with substrate specimen. It was also seen that, the improvement in wear resistance was (94%) as compared with substrate metal when carburizing treatment is carried out on hard chromium plating specimens.

في هذا البحث استخدمت طريقة الطلاء الكهربائي بالكروم الصلد، وهي إحدى طرائق الطلاء بتكوين غطاء على السطح، باستخدام حامض الكروميك كمصدر الكروم وكذلك حامض الكبريتيك كعامل محفز اذ أن نسبة حامض الكروميك إلى حامض الكبريتيك كانت (1:100) على التوالي. تمت عملية الطلاء بتسليط كثافة تيار مقدارها (40 Amp / dm2) ودرجة حرارة محلول الطلاء 55 – 50)ºC) ولفترات زمنية مختلفة (1 – 5 hr). استخدم الفولاذ منخفض الكاربون نوع ((CK15 كسبيكة أساس (Substrate) لغرض طلاءها بالكروم الصلد. تم أجراء المعاملة الحرارية الكيمياوية ( الكربنة الصلبة) للعينات المطلية بالكروم الصلد عند درجة حرارة (925ºC) ولفترة زمنية (2hr) للحصول على طبقة من كاربيدات الكروم. إذ تم تحديد الأطوار البلورية المكونة لطبقة الطلاء بعد أجراء الكربنة الصلبة والمتبوعة بالتقسية والمراجعة بجهاز حيود الأشعة السينية فقد تم الحصول على كاربيدات الكروم من نوع (Cr23C6, Cr7C3). وتم قياس الصلادة الدقيقة للعينات المطلية بالكروم اذ تم الحصول عل صلادة عالية تقدر (907HV). أما بعد أجراء الكربنة الصلبة لعينات الطلاء فقد ارتفعت قيم الصلادة وبشكل ملحوظ حيث أظهرت النتائج أن أعلى صلادة كانت لطبقة طلاء الكروم على سطح الفولاذ منخفض الكاربون كانت (1276HV) ويعزى سبب ارتفاع قيم الصلادة إلى وجود كاربيدات الكروم ضمن طبقة الطلاء.استخدم جهازالبلى نوع المسمار – القرص (Pin on Disc) لدراسة خواص البلى الانزلاقي الجاف لعينات الفولاذ منخفض الكاربون (كما استلمت) والعينات المطلية بالكروم الصلد والمكربنة كربنة صلبة. ولقد تم دراسة تأثير الحمل المسلط على معدل البلى بطريقة الفقدان بالوزن باستخدام أحمال عمودية مختلفة هي 25 , 20 , 15 , 10 , 5) N) وسرعة انزلاقية (Sliding speed) (2.198 m / sec). وقد أظهرت النتائج ان معدل البلى يزداد مع زيادة الحمل المسلط للعينات المطلية بالكروم, وأن أعلى مقاومة للبلى تم الحصول عليها بعد أجراء الكربنة الصلبة للعينات المطلية بالكروم حيث لوحظ التحسن الكبير في مقاومة البلى وبما يعادل (%94 ) مقارنة بالفولاذ منخفض الكاربون بحالته المستلمه.


Article
A Comparison between cooking tea-waste and commercial activated carbon for removal of chromium from artificial wastewater
المقارنة بين استخدام مخلفات الشاي المطبوخ و الكاربون المنشط التجاري في إزالة الكروم السداسي من المياه المتخلفة المصنعة

Author: Hadi Ghali Attia هادي غالي عطية
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2012 Volume: 16 Issue: 1 Pages: 307-325
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The compare Cr (VI) adsorption characteristics removing from artificial wastewater by using decolorized cooking tea waste (CTW) and commercial activated carbon (AC) were examined. Adsorption experiments were carried out in a batch process and various experimental Parameters such as effect of pH, rpm, temperature, adsorbent dosage, contact time, and initial chromium ion concentration on percentage removal have been studied. Adsorption process was found for two adsorbents to be highly pH dependent. The maximum removal took place at the pH 2. A significant fraction of the total Cr (VI) uptake was achieved within 180 min and initial concentration of 50 mg/L. The maximum efficiency of chromium removal was 99.5% and 99.4% for CTW and AC, respectively and maximum adsorption capacity of chromium ion by using AC and CTW were 42.42, 42.46 mg/g respectively. Studies showed that the Freundlich adsorption model better fitted with the results than Langmuir with R2 equal 0.991 and 0.974 for AC and CTW, respectively. The chromium uptake by the CTW and AC was best described by pseudo-second order rate model. This investigation verifies the possibility of using CTW as a low cost material for the removal of chromium from aqueous solution comparing with AC.

يهدف البحث الى المقارنة في خواص الامتزاز بين استخدام مخلفات اوراق الشاي المطبوخ والكاربون المنشط. حيث عملية الامتزاز اجريت في منظومة دفعية وتم فيها دراسة المعاملات التالية مثل الرقم الهيدروجيني, سرعة الخلط, درجة الحرارة, وزن المادة المازة, زمن الخلط و تركيز الاكروم الاولي على نسبة الازالة. حيث اثبتت عملية الامتزاز اعتماد كبير على الرقم الهيدروجيني حيث كانت اعلى نسبة امتزاز عند الرقم الهيدروجيني يساوي (2). وكان زمن الاتزان بالنسبة الى تركيز الاكروم السداسي البالغ (50) ملغرام/لتر هي 180 دقيقة. وكانت النسبة العظمى لإزالة الكروم باستخدام مخلفات أوراق الشاي المطبوخ هي 99.5% وبالنسبة الى الكاربون المنشط كانت 99.4% إما بالنسبة إلى قيمة الامتزاز العظمى لايون الكرم باستخدام الكاربون المنشط ومخلفات أوراق الشاي المطبوخ هي 42.42 و 42.46 ملغرام/غرام على التوالي. بينت الدراسة ان النتائج اكثر انطباقا مع موديل فريندلش منه مع موديل لانكماير. وكذلك انطباق البيانات مع الموديل من الدرجة الثانية من الناحية الكينماتيكية منه مع الموديل من الدرجة الاولى. ومن هذا البحث يتبين انه بامكان استخدام مخلفات الشاي المطبوخ كمادة رخيصة الثمن في عملية ازالة الكروم مقارنة مع الكاربون المنشط التجاري.


Article
Reducing the Concentrations of Chromium and Cyanide from Industrial Wastewater By Chemical Treatments Substitutes
خفض تراكيز الكروم والسيانيد في المياه العادمة الصناعية باستخدام بدائل المعالجة الكيميائية

Authors: علي شهاب احمد علي --- أحمد جاسم مخلف
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 6 Pages: 271-276
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The attempt on Chromium and Cyanide removing from industrial wastewaterof chemical plotting was achieved by using the natural polymer ( animal gelatin 0and calcium salts . Among three treatments with non treated wastewater , we wereselected the treatment with calcium chloride and gelatin in which the chromium(Cr +6 ) reduced from 3.5 mg /l to 0.86 mg / l and the cyanide from 0.06 mg /l to0.03 mg / l . The treatment with gelatin alone reduced concentration of the cyanideto 0.015 mg / l. Chromium adsorption in three treatments after two hours ofstabling was ranged between 37 – 75 % and cyanide 30 – 75 % which becamewithin the limitation.


Article
Nickel & Chromium Ions Release from Fixed Orthodontic Appliances in Iraqi patients

Loading...
Loading...
Abstract

Nickel and chromium can cause hypersensitivity in some people , this study wasconducted to investigate the alteration in the nickel and chromium concentrations insaliva of patients with fixed orthodontic appliance.The investigation is comprised of 45 orthodontic patients .The selected sampledivided into 3 groups. The first group consisted of 15 patients with fixed appliancesin their upper & lower arches. The second group consisted of 15 patients with a fixedappliance placed only in the upper arch. The control group consisted of 15 patientswho were not undergoing orthodontic treatment.Nickel and chromium release was quantified with the use of an atomic absorptionspectrophotometr. The analysis of variance was used to determine if differencesexisted between the nickel and chromium release according to time interval. Foursamples of stimulated saliva were collected from each patient before insertion of fixedappliance, 1 week , 1month , and 2month after insertion of the appliance.A considerable variation in the concentrations of both nickel and chromium wasobserved. Significant differences were found between the no-appliance samples andthe samples obtained after insertion of the appliance.Nickel and chromium concentrations of saliva are significantly affected by fixedorthodontic appliances during the first 2 month of treatment.


Article
Nickel And Chromium Ions Levels In Saliva Of Patients With Fixed Orthodontic Appliances

Author: Zinah Tawfeeq Neamah
Journal: Medical Journal of Babylon مجلة بابل الطبية ISSN: 1812156X 23126760 Year: 2014 Volume: 11 Issue: 3 Pages: 557-566
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Objective :The aim of this study was to test the hypothesis that there is no difference in salivary metal ion content between subjects with fixed orthodontic appliances and their same-gender sister or brother without any orthodontic appliance.Materials and Methods: Fifty orthodontic patients were included in this study. The first group consisted of 25 patients (14 female, 11 male) with fixed appliances placed in their upper and lower arches. The second group consisted of 25 patients(13 female, 12 male) with a fixed appliance placed only in the upper arch. In order to limit the effects of dietary and hygiene habits on salivary metal ion concentration, a same-gender brother or sister (total of 50 subjects) was selected as a control (25 female, 25 male) who were not undergoing orthodontic treatment. Four samples of stimulated saliva were collected from each patient before insertion of the fixed appliance, 1 month after insertion of the appliance, 2 months after insertion of the appliance and 6 months after insertion of the appliance. The 4 samples of saliva were collected from each control patient at the same time intervals as for the fixed-appliance groups .Approximately 5 ml of saliva was collected from each subject. Saliva samples were analyzed for nickel, chromium, by electrothermal atomic absorption spectrophotometry. The detection limit of the method for sample solutions was 1 ng/ml. Statistical analysis was performed by nonparametric tests (Mann–Whitney U and Wilcoxon W).The Wilcoxon matched pairs signed ranks used to test differences between samples before and after insertion of the orthodontic appliances. A Kruskal Wallis 1-way analysis of variance was used to test differences in nickel and chromium concentration among the 3 test groups. A Kruskal Wallis 1-way analysis of variance (ANOVA) was used to test differences in nickel and chromium concentrations among the 3 test groups.Results: The mean salivary nickel (Ni) content in subjects with and without a fixed orthodontic appliance was 16.8 ± 12.2 ng/ml and 10.3 ± 11.7 ng/ml, respectively. A statistically significant difference (P < 0.041) was found between the two groups. The mean salivary chromium (Cr) ion level recorded was 2.4 ± 1.8 ng/ml in the study group and 2.1 ± 1.6 ng/ml in the control group. The difference, however, was statistically insignificant.Conclusion: Nickel and chromium ion concentrations increased immediately after placement of the appliance in the mouth for all study groups. There were no significant differences in the nickel ,chromium levels released by the three groups of appliances at all study periods.Within the limits of this in vivo study, it can be concluded that the presence of fixed orthodontic appliances leads to an increased concentration of metal ions in salivary secretions

هو اختبار الفرضية بانه لا يوجد فرق في محتوى ايون الفلز اللعابي بين الاشخاص الحاملين لجهاز التقويم الثابت بالمقارنة مع اشقائهم من نفس الجنس بدون أي جهاز تقويم.المواد والطرق: تم تضمين 50 مريض تقويم في الدراسة.المجموعة الولى تكونت من 25 مريض(14 اناث و 11 ذكور) مع جهاز التقويم الثابت في الفك العلوي والسفلي .المجموعة الثانية تكونت من 25 مريض (13 اناث و 12 ذكور) مع جهاز تقويم ثابت في الفك العلوي فقط.ولغرض تحديد تاثيرات الطعام والعادات الصحية على تركيز ايون الفلز اللعابي تم المقارنة مع 50 شخص قياسي (25 اناث و 25 ذكور) وهم اشقائهم من نفس الجنس بدون أي جهاز تقويم.تم جمع اربع عينات من اللعاب المحفز من كل مريض الاولى قبل ادراج الجهاز والثانية بعد شهر من ادراج الجهاز والثالثة بعد شهرين من ادراج الجهاز والرابعة بعد ستة اشهر من ادراج الجهاز.نفس الاربع عينات جمعت من كل مريض قياسي في نفس الفترات الزمنية لمرضى الجهاز الثابت.تم جمع تقريبا 5 مل من اللعاب من كل مريض تقريبا .تم تحليل عينات من اللعاب للنيكل والكروم بواسطة كهروحرارية المقياس الطيفي للامتصاص الذري.كان الحد من الكشف عن طريقة ايجاد حلول عينة 1 نانوغرام/مل.تم اجراء التحليل الاحصائي عن طريق اختبارات اللامعلمية.Wilcoxon matched pairs signed ranksاستعمل لاختبار الفروقات بين العينات قبل و بعد ادراج اجهزة التقويم.تحليل التباين A Kruskal Wallis 1-wayاستعمل لاختبار الفروقات في تركيز النيكل والكروم في المجاميع الثلاثة. النتائج:معدل محتوى النيكل اللعابي في الاشخاص مع وبدون جهاز التقويم الثابت 12.2±16.8 نانوغرام/مل و ±11.310.3 نانوغرام/مل تتابعيا.وجد هناك فرق احصائي هام بين المجموعتين.المستويات المسجلة لمعدل الكروم اللعابي كانت 1.8 ±2.4 نانوغرام/مل في مجموعة الدراسة و1.6± 2.1 نانوغرام/مل في مجموعة القياس.لكن الفرق احصائيا كان ضئيل.ضمن حدود هذه الدراسة الحية ممكن الاستنتاج بانه وجود اجهزة التقويم الثابتة تؤدي الى زيادة تركيز ايونات الفلز في الافراز اللعابي.


Article
Comparison of metal ions release and corrosion potential from different bracket archwire combinations (An in vitro study)

Authors: Asmaa M. Khamees اسماء خميس --- Sami K. Al-Joubori سامي كاظم الجبوري
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2014 Volume: 26 Issue: 1 Pages: 171-179
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study wasconducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combinationof monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate thecorrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and toevaluate the corrosion potential of each group of the orthodontic appliances.Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, fromthe central incisor to the first molar, for the maxillary arch, each set consisted of molar band, five brackets, half archwire and ligature elastic.These sets are divided into two groups: Group A: with monocrystalline brackets divided intofive subgroups (each subgroup has ten sets), but differ in arch wires, as numbered stainless steel, nickel-titanium,thermally activated, coated stainless steel and coated nickel-titanium arch wires respectively. Group B: with stainlesssteel brackets divided into three subgroups (also each subgroup has ten sets), but differ in arch wires, asnumberedstainless steel, nickel-titanium, and thermally activated arch wires respectively. Used optical microscope tocheck the corrosion points, and used potentiostat techniques to indicate corrosion rate and tendency.Results: The greatest concentration of Aluminum and nickel ions release during the 1st week in group A, then sharplydecreased in the 2nd week. The release of chromium ion released increase with increase intervals, while iron ionreleased decrease with increase time. Both nickel and chromium ions increase with increase intervals in group B,whileiron increase to the maximum at 3rd weeks, then began to degrease. Optical microscope displayed pitting, crevices,and intergranular corrosion. Potentiostat techniques indicated that increase corrosion when used stainless steel andcoated nickel titanium than others arch wires with group A, while corrosion increase with nickel titanium than stainlesssteel arch wires with group B.Conclusions: Non-significant difference in the total nickel, chromium and iron release in group B. Aluminum and ironincrease in A4 and A5, while nickel and chromium increase in A1 and A2.The total released amounts of metals ions inboth groups were less than the amounts of daily intake

Keywords

ions release --- aluminum --- nickel --- chromium --- iron


Article
Removal of Lead and Chromium From Industrial Wastewater by LocallyCitrobacter spp.Isolates
ازالة عنصري الرصاص والكروم من مياه الفضلة الصناعية بوساطة عزلات محلية من بكتريا Citrobacter spp.

Authors: Maiada K. H. Aloosh ميادة خزعل حسن علوش --- Mohammad. N. A. Al- Azzawi محمد نافع علي العزاوي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 2A Pages: 983-997
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Biosorption is an effective method to remove toxic metals from wastewaters. In this study biosorption of lead and chromium ions from solution was studied using Citrobacter freundii and Citrobacter kosari isolated from industrial wastewater. The experimental results showed that optimum grwoth temperature for both bacteria is 30oC and the optimum pH is 7 &6 for C. freundii and C. kosari respectively. While the optimum incubation period to remove Pb and Cr for C. freundii and C. kosari is 4 days and 3days respectively. Also the biosorption of Pb and Cr in mixed culture of bacteria and mixed culture of Pb and Cr was investigated. Result indicate that uptake of Cr and Pb for C.freundii, C. kosari and in mixes culture of both bacteria is 58%, 53% and 82% respectively for chromium in solution containing 1000ppm of Cr and 59%, 63% and 78% respectively for lead in solution containing 1000ppm of lead. But the uptake decreases in solution containing both heavy metals lead and chromium.

الامتزاز عملية فعالة لازالة المعادن السامة من المياه الملوثة. لقد تم دراسة امتزاز كل من عنصري الرصاص و الكروم باستعمال سلالات من بكتريا Citrobacterfreundiiو Citrobacterkosariالمعزولة من مياه الفضلة الصناعية. لقد بينت النتائج ان درجة الحرارة 30°م هي الفضلى لنمو كلا العزلتين, والرقم الهيدروجيني الامثل لنمو العزلتين هو 6 و7 لبكتريا C.freundiiوC. kosari على التوالي. اما فترة الحضانة الملائمة لبكترياC.freundii و C. kosari فقد كانت 4 ايام و 3 ايام على التوالي. وايضا تم دراسة امتزاز عنصري الكروم والرصاص في وسط يحتوي على كلا العزلتين وايضا على وسط يحتوي على خليط من عنصري الرصاص والكروم. لقد بينت النتائج ان النسبة المئوية لازالة عنصري الكروم و الرصاص لبكترياC. freundiiو C. kosariوخليط العزلتين كانت 58%, 53%, 82% على التوالي بالنسبة لعنصر الكروم في وسط حاوي على 1000جزء بالمليون من الكروم اما بالنسبة للرصاص فقد كانت نسب الازالة 59%, 63%, 78% على التوالي في وسط حاوي على 1000جزء بالمليون من الرصاص اما الوسط الحاوي على خليط من الرصاص والكروم فقد كان الامتزاز اقل من الوسط الحاوي على احد العنصرين.

Keywords

Biosorption --- Lead --- Chromium --- C. freundii --- C. kosari.


Article
Spectrophotometric Determination of Chromium Using Indigo Carmine -Application in Various Samples
التقدير الطيفي للكروم باستخدام صبغة الانديكوكارمين - التطبيق في نماذج مختلفة

Authors: Najih H.Shekho ناجح حسن شيخو --- Hind A. Mahmoud هند أحمد محمود
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2016 Volume: 13 Issue: 3 Pages: 556-567
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium is studied. The method is based on the interaction of chromium with indigo carmine dye in acidic medium and the presence of oxalates as a catalyst for interaction, and after studying the absorption spectrum of the solution resulting observed decrease in the intensity of the absorption. As happened (Bleaching) for color dye, this palace and directly proportional to the chromium (VI) amount was measured intensity of the absorption versus solution was figurehead at a wavelength of 610 nm. A plot of absorbance with chromium (VI) concentration gives a straight line indicating that Beer’s law has been obeyed over the range of 0.5 -70 µg /25 ml, i.e., 0.02- 2.8 ppm with a molar absorptivity of chromium (VI) 1.71 104 l.mol-1.cm-1, Sandell’s sensitivity index of 0.0030 µg.cm-2 .The detection limit of chromium was (DL) 0.0012 µg.mL-1 and a relative standard deviation of  (0.70 -1.86)% depended on the concentration level. The method is developed for the determination of chromium(III) and has been successfully applied to the determination of chromium in various water samples, Pharmaceutical preparations ,standard rock sample of (MRG-1).

تم تطوير طريقة طيفية بسيطة وسريعة وحساسة لتقدير كميات متناهية في الصغر من الكروم .تعتمد الطريقة على تفاعل الكروم مع صبغة الانديكوكارمين في الوسط الحامضي بوجود الاوكزالات كمحفز للتفاعل ولوحظ انخفاض في شدة الامتصاص بسبب قصر (Bleaching) لون الصبغة وهذا القصر يتناسب طرديا مع كمية الكروم (VI) عند طول موجي 610 نانومتر. اظهر منحني الامتصاص مقابل التركيز خطا مستقيما والذي يؤكد على انه يتبع قانون بير 0.5- 70 مايكروغرام من الكروم في حجم نهائي 25 مللتر (0.02 -2.8 جزء/مليون) وكانت الامتصاصية المولارية 1.71 104 لتر.مول-1.سم-1 ودلالة ساندل للحساسية 0.0030 مايكروغرام .سم-2 وحد الكشف 0.0012 مايكروغرام .مللتر-1, والانحراف القياسي النسبي بين (0.70) و 1.86)) % اعتمادا على مستوى التركيز. وقد طورت الطريقة المقترحة لتقدير الكروم الثلاثي وتم تطبيق الطريقة بنجاح لتقدير الكروم في نماذج مائية مختلفة ومستحضرات دوائية وكذلك في نموذج من الصخور القياسية (MRG-1) .


Article
Determination of Chromium in blood serum using Atomic Absorption Spectrophotometric (AAS)

Authors: Mohammed T. Khathi --- Abeer Q. Abdulwahab --- Zainab M. Kareem
Journal: Univesity of Thi-Qar Journal مجلة جامعة ذي قار العلمية ISSN: 66291818 Year: 2016 Volume: 11 Issue: 2 Pages: 1-14
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

A new approach for the direct determination of chromium by Electrothermal Atomic Absorption spectrometry (ETAAS) is proposed, the method employs a 1.0 cm X 0.3 cm Tantalum metal coil placed in graphite tube. The experimental conditions for the determination of chromium via this method have been optimized. Pyrolysis and atomization curves are constructed using uncoated graphite tube without and with coil. The calibration curves were linear over the rang 10- 50 ng/ml of chromium concentration, with relative standard deviation values, at 0.013, 0.018 and 0.024µg/ml. the accuracy and precision of the method was evaluated by determining recoveries percentage between (99.7-101) and standard deviation and using different concentrations of standard solutions of this method was applied successfully for the determination of chromium in human blood serum.

تضمنت الدراسة تطوير طريقة جديدة لتقدير عنصر الكروم مباشرة باستخدام مطيافية الامتصاص الذري الكهروحراري بوجود منصة معدنية من عنصر التنتاليوم بابعاد 1سم طول وعرض 0.3 سم يتم وضعها داخل الفرن الكرافيتي بشكل ملف. تم دراسة الظروف الالية لتقدير عنص الكروم باستخدام الطريقة الجديدة ورسم منحني الترميد والتذرية باستخدام الفرن الكرافيتي بوجود وبعدم وجود الملف ووجد تطور كبير في المعطيات التحليلية بوجود الملف وكان منحني المعايرة خطيا لعنصر الكروم مع انحراف قياسي نسبي مئوي قليل لمحاليل قياسية معلومة وطبقت الطريقة بنجاح لتقدير عنصر الكروم في نماذج من مصل الدم

Listing 11 - 20 of 72 << page
of 8
>>
Sort by
Narrow your search

Resource type

article (72)


Language

English (63)

Arabic (5)

Arabic and English (3)


Year
From To Submit

2019 (5)

2018 (13)

2017 (3)

2016 (17)

2015 (1)

More...