THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH3 – H2O SYSTEM

Authors: Ahmed Deaa Nasiaf --- Adel A. Al-Hemiri عادل احمد عوض
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2010 Volume: 11 Issue: 4 Pages: 13-21
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work was conducted to study the coefficient of performance for solar absorption refrigeration by using direct solar energy using aqueous ammonia 0.45 mass fraction (ammonia – water).The experiments were carried out in solar absorption system .The system consisted of solar collector generator (0.25 m × 0.25 m × 0.04m) and condenser cooled by a water bath followed by liquid receiver and evaporator. The results showed that the maximum generator temperature was (92° - 97°) during June 2009, and the minimum evaporator temperature was (5°C - 10°C) for aqua ammonia system.. It was, also, found that the coefficient of performance, cooling ratio and amount of cooling obtainable increased with increasing maximum generator temperature and pressure. While the minimum evaporator temperature and concentration decreased with increasing maximum generator temperature and pressure. The coefficient of performance was (0.1096 - 0.2396).


Article
Improvement of solar cell efficiency by using Two mirrors V-trough concentrator
تحسين أداء الخلايا الشمسية باستخدام تصاميم جديدة لمركز حوضي مركب نوع V ثنائي المرايا المغطى بعدسات فرينيل

Author: علي هادي الحمداني
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 3 Pages: 126-130
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

V-trough concentrator with four mirrors has been designed and constructed. Itseffects on the silicon solar cell performance were studied with and with out coolingsystem. It was shown that the cell efficiency was increased from 11.94 % to 15.46 %with out cooling and from 13.3 % to 16.4 % with cooling system. The effect of acombination between Fresnel lens and V-trough concentrator was studied also. The solarcell efficiency was improved to 24 % with out cooling and the best efficiencyimprovement was 26.6% with cooling system.

ائي المرايا وتمت ( V-trough connectivity ) V تم تصميم وبناء مركز حوضي جديد نوعدراسة تأثيره على كافة معلمات تقييم أداء الخلية الشمسية السيليكونية في حالة عدم وجود نظام تبريد ووجوده,لوحظ إن كفاءة أداء هذه الخلية قد ازدادت من 11.94 % إلى 15.46 % بدون تبريد أما مع التبريد فقد ازدادتكفاءة الأداء من 13.3 % إلى 16.40 %. كما تمت دراسة تأثير الجمع بين أنواع مختلفة من عدسات فرينيل معهذا المركز على أداء الخلية الشمسية حيث تم الحصول على افضل أداء للخلية وقدره 24 %. بدون تبريد وعلىأفضل أداء مقداره 26.6 % بوجود نظام تبريد.


Article
A House Solar Power Station
محطة طاقة شمسية للبيتِ

Author: Kareem A. Hamad1 كريم عباس حمد
Journal: Al-Rafidain University College For Sciences مجلة كلية الرافدين الجامعة للعلوم ISSN: 16816870 Year: 2011 Issue: 27 Pages: 5-18
Publisher: Rafidain University College كلية الرافدين الجامعة

Loading...
Loading...
Abstract

Solar energy is one of the main power sources of electricity in the world. It has become widespread as an attractive solution to provide low power consumption to human groups live in remote villages or areas away from the national electric grid, also when the electric power is underproduction such as in our country (Iraq). For this reasons we designed a system of photovoltaic generator with facilities to be built in houses. The system consists of three basic parts of equipment, 3KW peak solar panels, which could be spread easily at the housetop, a storage battery system and the electrical control system. The electrical control system was completely designed and tested using ORCAD simulator, it consists of 4KW battery charge regulator with 300V system, and 220V, 50Hz transformerless three – level square wave inverter.

الطاقة الشمسيةِ هي إحدى المصادر الرئيسية للكهرباء في العالم. أَصْبَحَ استخدامها واسع الانتشار كحَل جذاب لتزويد كهربائيَ منخفضَ في القُرى أَو المناطقِ البعيدةِ عن الشبكةِ الكهربائيةِ الوطنيةِ أو عندما يكون إنتاج الطاقة الكهربائية غير كاف للطلب كما هو الحال في بلدنا (العراق). ولهذا السبب صمّمنَا نظام توليد للكهرباء يعتمد على الطاقة ألشمسيه بوسائل يمكن أن تبنى في البيوت. تتكون المنظومة من ثلاثة أجزاء أساسيه, ألواح شمسيه بقدرة3KW يمكن نشرها على سطح المنزل, بطاريات خزن ونظام سيطرة كهربائي.نظام السيطرة الكهربائي صمم بالكامل واختبر باستعمال محاكي ORCAD. يستعمل هذا النظام منظم فولية لشحن البطاريات بقدرة 4KW بفولتية 300V, وعاكس لا يحتوي على محولة مربع الموجة بفولتية 220V وتردد 50Hz


Article
The Effect of Adding Carbon (soot) to the Paint of an Absorbing Surface in Homemade Solar Systems
تأثير إضافة الكربون على الطلاء للسطح الماص في المجمعات الشمسية الحرارية

Author: Hala K. Saleh هالة قيدار محمد صالح
Journal: Rafidain journal of science مجلة علوم الرافدين ISSN: 16089391 Year: 2012 Volume: 23 Issue: 3E Pages: 137-143
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Absorbing materials are key components of any solar water heater device. Silicon solar cells are very efficient but are highly expensive. An alternative is to use absorbing materials that are cheaper than silicon to produce. The use of carbon (soot) in the preparation of the coating layer of a homemade solar water heater has been investigated. When added in different proportions to oil-based white paint, marked increases in water temperatures were obtained. The increase in water temperature was directly proportional with the increase in the percentage of carbon in the coating layer. The maximum achieved outlet water temperature was 90° C in July and 70° C in November.Due to its non-toxic nature and very low cost, carbon in the form of smoke suspension or soot, can provide a good and reliable alternative in the fabrication of domestic solar water heaters.

تعد المواد الماصة جزءا مهما لأي نظام سخان حراري شمسي. تكون خلايا السليكا الشمسية ذات كفاءة عالية جدا لكنها مرتفعة الكلفة أيضا. إن البديل هو استخدام مواد ماصة أرخص كلفة من السليكا عند الإنتاج. إن استخدام الكربون في تحضير طبقة الطلاء لسخان ماء شمسي قد تم اختباره. فعندما يضاف الكربون بنسب مختلفة إلى طلاء زيتي أبيض، نحصل على درجة حرارة ماء مرتفعة. يتناسب ازدياد درجة حرارة الماء طرديا مع زيادة نسبة الكربون المضاف إلى طبقة الطلاء. كانت أعلى درجة حرارة للماء °90 سليزية في تموز و°70 سليزية في تشرين الثاني.وبالنظر إلى طبيعة الكربون غير السامة ورخص كلفته، فإنه يوفر بديلا جيدا يمكن اعتماده في عمل سخانات الماء الحرارية المحلية الصنع.

Keywords

carbon --- coating --- solar heater


Article
The solar eclipse and its relation with higree months
كسوف الشمس وعلاقته بالأشهر الهجرية

Author: Abdul Rahman H. S. عبد الرحمن حســين صالح
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2013 Volume: 11 Issue: 22 Pages: 72-81
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The solar eclipse occurs at short time before the crescent birth moment when the moon near any one of moon orbit nodes It is important to determine the synchronic month which is used to find Higree date. The 'rules' of eclipses are: Y= ± 0.997 of Earth radius , the solar eclipse is central and 0.997 < |Y| < 1.026 the umbra cone touch the surface of the Earth, where Y is the least distance from the axis of the moon's shadow to the center of the Earth in units of the equatorial radius of the Earth.A new model have been designed, depend on the horizontal coordinates of the sun, moon, the distances Earth-Moon (rm), Earth-sun (rs) and |Y| to determine the date and times of total solar eclipse and the geographical coordinates of spot shadow as well as the shadow diameter and the variations with time.The results are compared with Almanac and others programs are gets a good agreements and the results show the area of eclipse shadow inversely proportional with rm /rs .The Higree month which must be begin after the solar eclipse and the relation were discussed hear.

يحصل كسوف الشمس قبل ولادة الهلال بوقت قصير عندما يكون القمر قريب جدا من إحدى العقدتين لمداره لذلك فهو مهم لتحديد بدايات الأشهر القمرية الاقترانية التي تستخدم لتحديد بدايات الأشهر الهجرية, ويكون كسوف الشمس مركزيا عندما المسافة بين محور الظل ومركز الأرض± 0.997 = Y بوحدات نصف قطر الأرض ويسقط ظل الكسوف على سطح الأرض عندما .0.997 < |Y| < 1.026تم تصميم نموذج جديد يعتمد على الإحداثيات الأفقية للشمس والقمر (الاتجاه والارتفاع الزاوي) كذلك يعتمد على المسافتين أرض - قمر وأرض – شمس التي حسبت بدقة وعلى بعد مخروط الظل عن مركز الأرض Y لنحصل على تواريخ وأوقات الكسوف الكلي للشمس و حساب الإحداثيات الجغرافية لمسقط الظل على سطح الأرض إضافة إلى حساب قطر الظل وتغير كل هذه المعلومات مع الزمن. تم مقارنة النتائج مع المناخ الفلكي وبرامج أخرى وبينت توافق جيد, كذلك استنتجنا من هذا البحث أن مساحة ظل الكسوف تتناسب عكسيا مع rm / rs , ولوحظ الكسوف دائما قبل بداية الأشهر الهجرية وتمت مناقشة ذلك.


Article
Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
تأثير ادخال شرائط ملتوية على اداء مجمعات الماء الشمسية المسطحة

Authors: Jafar M. Hassan جعغر مهدي حسن --- Qussai J. Abdul-Ghafour قصي جهاد عبد الغفور --- Mohammed F. Mohammed محمد فوزي محمد
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2015 Volume: 11 Issue: 3 Pages: 37-46
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5). The collectors are connected in parallel mode (Z-Configuration) and are exposed to the same conditions (solar radiation and ambient temperature) .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3) .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at different flow rate used (60,100 and 150) ℓ /hr. were 49 %, 57% and 63% respectively.

لغرض تحسين كفاءة مجمعات الماء الشمسية المسطحة بدون احداث تغيير في الشكل الاصلي مع اضافة بسيطة للتكلفة، تم اقحام شرائط ملتوية داخل انابيب رفع الماء. تم استخدام ثلاثة مجمعات شمسية مسطحة لغرض الدراسة. حيث وضعت مجموعة من الشرائط الملتوية مختلفة في نسبة الالتواء (TR=3,4,5) داخل انابيب رفع الماء لكل مجمع . تم ربط المجمعات على التوازي (شكل –Z ) وتعريضها للضروف نفسها (شدة الاشعاع الشمسي و درجة حرارة المحيط). اوضحت النتائج العملية ان اعلى معدل لانتقال الحرارة حصل عند نسبة التواء (3). ونتيجة لذلك و لنسبة الالتواء نفسها كانت قيمة الكفاءة اليومية للمجمع الشمسي لعدد من قيم معدل الجريان (60,100,150) لتر/ ساعة بلغت 49% ،57% و63% على التوالي .


Article
Investigation on an Intermittent Absorption Refrigeration prototype powered by Solar Irradiation

Authors: Haroun A.K. Shahad --- Dhafer A. Hamzah
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2015 Volume: 8 Issue: 4 Pages: 513-525
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

In this study, a design and fabrication of intermittent solar absorption refrigeration unit wasperformed at Hillah city in Iraq)32.4o, 44.4o). The absorption solar unit consists of parabolic troughconcentrator (PTC) was used as solar rays mirror reflector with aperture area of 2 m2 , carbon steelpipe inside a vacuum glass envelop with a diameter of 1.5 in as tubular receiver, condenser, storagetank, evaporator. The aqua ammonia solution) NH4OH)is used as working fluid with differentconcentration (25%, 30%, 35%, 40%). The validity and visibility of the unit were evaluated bymeasurements of pressures and temperatures at different parts of the unit during a year from Maymonth 2014 to July month 2015. The maximum pressure and temperature is found to be 12 bar and120oC respectively. The coefficient of performance was in the range of 0.01-0.09.

في هذه الدراسة ,تم انجاز تصميم وبناء منظومة تبريد امتصاصية تعاقبية في مدينة الحلة في العراق, الشمسية الامتصاصية تتكون من مركز على شكل حوض قطع مكافئ يستخدم كمرآة عاكسة للأشعة الشمسية بمساحة فتحة 2 م 2انبوب من الحديد الكربوني داخل غلاف زجاجي مفرغ من الهواء بقطر 5.1 انج يعمل كمستلم انبوبي. يستخدم محلول هيدروكسيد03 %(. تحقيق ووضوح الوحدة قيم من خلال قياسات للضغوط ,%01,%03,% الامونيوم كمائع تشغيل بتركيز مختلف ) 21ودرجات الحرارة خلال سنة من شهر ايار 2350 الى شهر تموز 2351 . اقصى ضغط ودرجة حرارة وصل ال 51 بار و 513. درجة سيليليزية. معامل الاداء كان يتراوح من 3.35 الى 3.3

Keywords

Solar --- Refrigeration --- Absorption


Article
Design and fabrication of Solar dish array and study it characterization
تصميم وتصنيع مركز شمسي طبقي بشكل مصفوفة ودراسة خصائص

Authors: Yaseen. H. Mahmood ياسين حميد محمود --- Auatf S. Jassim عواطف صابر جاسم --- Farah N. Hamed فرح ناصر حمد
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2017 Volume: 22 Issue: 11 Pages: 87-91
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Designed and fabricated a (3.25m) solar dish array ,by using (52) plane mirror. These mirrors are level and fixed to reflect the radiation in one area (focus) and after distance (1.5 m). In addition, it was found that the heat concentration (217.79 W) the useful energy (1416.125W) and the center efficiency were55% at (400-700W/m2). The solar dish array is relatively suitable for solar thermal applications.

تم تصميم وتصنيع مركز شمسي طبقي بمساحة (3.25 متر) على شكل قطع من المرايا بعدد (52) وهذه المرايا مستوية وثبتت بحيث تعكس الاشعاع في منطقة واحدة (البؤرة). وعلى بعد (1.5) متر. كما تم استخدام مستلم اشعاع اسطواني (كمسخن) ووضع بالبؤرة , حيث وجد عامل ان التركيز(58), اما عمليا فقد وجد ان خسائر الحرارة تقريبا (17.79 W) والطاقة المفيدة (1416.125W) وكفاءة المركز55% عند (400-700W/m^2). المركز المصنع مناسب نسبيا للتطبيقات الشمسية الحرارية.


Article
COMPARISON BETWEEN SIMULATED AND CALCULATED POWER OF THE SOLAR CHIMNEY WITH BLACK CONCRETE BASE USING ANSYS PROGRAM
مقارنة بين القدرة النظرية والمحسوبة لمدخنة شمسية ذات قاعدة كونكريتية سوداء بأستخدام برنامج ANSYS

Loading...
Loading...
Abstract

A solar chimney has been analyzed by solving its governing equations and compare with the simulated results. The solar absorbent of the chimney is selected as a black painted concrete, which is useful as an energy saver at night. The numerical simulation using ANSYS, based on solving the governing equations with suitable assumptions and boundary conditions for many variables such as the collector area, the chimney height, the ambient temperature, and the exit area of the chimney. The results shows that the chimney height and base area are very important parameters for improving the gained power, and it is also important to choose the region with suitable mean ambient temperature. And economically there are limitations to collector and chimney sizes to get suitable profit output power and any increment in system size becomes a small percentage increment in profit output power. The results compared with some experimental data from other results researchers and there is a good agreement between simulated and calculated results

تم تحليل المدخنة الشمسية عن طريق حل المعادلات الحاكمة ومقارنة النتائج مع نتائج المحاكاة. إن اللوح الماص للمدخنة الشمسية تم اختياره من الكونكريت المطلي باللون الاسود والذي يعتبر مفيدا لخزن الحرارة ليلا. إن المحاكاة العددية باستخدام برنامج ANSYS 11.0 تم بناءه على حل المعادلات الحاكمة مع الفرضيات والشروط الحدية المناسبة لعدة متغيرات مثل مساحة المجمع ارتفاع المدخنة ودرجة حرارة المحيط و مساحة مخرج المدخنة. أظهرت النتائج أن ارتفاع المدخنة ومساحة المجمع هي عوامل مهمة جدا لتحسين القدرة الناتجة، وكذلك من المهم اختيار المنطقة بمعدل درجة حرارة محيط مناسبة.وان هناك محددات اقتصادية لحجم المدخنة والمجمع الشمسي للحصول على قدرة خارجة مناسبة وان أي زيادة في الحجم يقلل من نسبة الزيادة في القدرة الخارجة المفيدة. ناظرت النتائج في هذا البحث مع بعض النتائج التجريبية لباحثين آخرين وان هناك تقاربا جيدا بين نتائج الحسابات والمحاكاة .


Article
The Effect of Tilt Angle on the Solar Panel Output
تأثير زاوية الميلان على قدرة أنتاج اللوح الشمسي

Authors: Emad.Jaleel.Mahdi --- Sahib.N.Abdul-wahid
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2010 Volume: 8 Issue: 4 Pages: 75-82
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

In this project we study how the effect of changing tilt angulations of the solar panel and (1) the variations in the incident sunlight affects the amount of electrical output from the (2) on the efficiency of solar panels in Baghdad location. The correct installation position will allow solar panels to be exposed to direct, unobstructed sunshine from 7am to 4pm every day ,this study determined that the optimum tilt angle for a PV panel changes throughout the year, we installed solar panels in four angles (20ْ,35ْ,45ْ,55ْ) as a fixed solar panel in august 2009 and in January 2010 . The results showed that the gains in the amount of solar radiation throughout the year received by the PV panel mounted at 350 for fixed solar panel to Baghdad location for all days year.

في هذا البحث تم ملاحظة كيف يكون تأثير تغير زاوية ميلان اللوح الشمسي وعلاقته مع تغير شدة الإشعاع الشمسي الساقط عليه وتأثيرها على كفاءة وكمية القدرة الخارجة من اللوح الشمسي في موقع بغداد , وعملية التنصيب الصحيحة للوح الشمسي تسمح له بان يكون بالاتجاه المقابل إلى ضوء الشمس من الساعة السابعة صباحا إلى الرابعة مساءا . في هذه الدراسة أفضل زاوية ميلان للوح الشمسي خلال وعلى طول أيام السنة وتم تنصيب ألواح بأربع زوايا (ْ20, 35ْ, ْ45, ُْ55 ) وبتقنية اللوح الثابت في شهري آب 2009 وفي كانون الثاني 2010 ومن النتائج كانت أفضل ربح لكمية الإشعاع الشمسي والواصل إلى اللوح الشمسي هو بزاوية 35 درجة للوح الثابت ولموقع بغداد وعلى مدار السنة

Listing 11 - 20 of 406 << page
of 41
>>
Sort by
Narrow your search

Resource type

article (406)


Language

English (321)

Arabic (47)

Arabic and English (31)


Year
From To Submit

2019 (29)

2018 (68)

2017 (44)

2016 (35)

2015 (41)

More...