research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Concentration of Residual Chlorine in Tikrit University Water Supply Network
تراكيز الكلور المتبقي في شبكة ماء جامعة تكريت

Author: عفاف جدعان عبيد
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2011 Volume: 7 Issue: 1 Pages: 18-29
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Chlorine is considered as one of the most important disinfectants because of its availabilityin a wide form and in acceptable cost. Measurements of residual chlorine are very essential toassure the presence of disinfection at various locations of the water distribution system. Theaim of the present work is to find the residual chlorine concentrations in potable water whichleaves Tikrit University water supply plants. pH-, water temperature and water turbidity arealso measured. Sixty samples of tap water are tested during November 2009 till April 2010.The results show that range of residual chlorine is 0.2-4mg/l) and most of the measured valuesare higher than the maximum permissible limit according to Iraqi standards( 417/1974 )The data indicated that pH is within the range of (7-8.2) and there is no clear relationshipbetween pH and residual chlorine concentration. It is found that there an inverseproportionality between residual chlorinean and temperature . Same trend is found between residual chlorine and turbitiy. The Conductivity and total dissolved solid of drinking water waswithin the permitted level by the Iraqi standers

يعتبر الكلور من أهم المعقمات لتوفره بصورة واسعة وبكلفة معتدلة في اغلب مناطق العالم. ان وجود الكلور في مختلف مناطق شبكات الاسالة مهمجدا للتاكد من وجود التعقيم للمياه. يهدف البحث إلى إيجاد تركيز الكلور المتبقي في الماء الخارج من محطة إسالة ماء جامعة تكريت وبعض المناطق التابعة لهاضمن جامعة تكريت وملحقاتها.اختيرت هذه المناطق على مسافات مختلفة من المحطة وذلك لمعرفة وجود الكلور المتبقي في مياه الشرب ضمن الحدود المسموحة.ودرجة حرارة الماء والعكورة لستين عينة من ماء الشرب pH تم قياس تركيز الكلور المتبقي وكذلك قيم بعض العوامل المؤثرة ع ليه مثل الدالة الحامضية. خلال فترة الدراسة التي امتدت بين شهري تشرين الثاني ٢٠٠٩ الى نيسان ٢٠١٠٤ ملغرام/ لتر. ان معظم تراكيز - تم استعمال نماذج إحصائية لتحليل البيانات حيث بينت النتائج ان تركيز الكلور المتبقي تراوح بين ٠٫٢- فقد تراوحت بين ٧ pH الكلور المتبقي كانت اعلى من القيم المسموح بها وفق المعايير القياسية لمياه الشرب العراقية. اما بالنسبة لقيم الدالة الحامضية٨٫٢ واظهرت ا لنتائج عدم وجود علاقة واضحة بين هذه القيم وتركيز الكلور المتبقي. كذلك اشارت النتائج ان هناك تناسبا عكسيا بين درجة الحرارة وترك يزالكلور المتبقي وكذلك تناسب تركيز الكلور عكسيا مع الكدرة. أما بالنسبة للتوصيلية الكهربائية والاملاح الذائبة الكلية فقد كانت ضمن حدودالمواصفات القياسية العراقية.


Article
Construction and Operation of Two Chamber Fuel Cell under Synthetic and Real Wastewater with Different Operation Conditions
تصميم وتنفيذ خلية الوقود ذات وعائين باستخدام مياه الصرف الصحي المصنعة والحقيقة بمختلف الظروف التشغيلية

Author: Afaf Jadaan obeid عفاف جدعان عبيد
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2018 Volume: 12 Issue: 1 Pages: 67-74
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Constructing and testing a microbial fuel cell, (MFC) was accomplished in this research. Two chambers MFC connected with salt bridge was operated and studied using synthetic and real wastewater as anode chamber solution. Operating temperature and pH value were investigated by changing temperature from 25 OC to 30 OC and varying pH from 6.7 to 6.5. The results reveled that increasing operation temperature had a significant effect on reducing operation time while decreasing pH improved the measured voltage and current besides reducing operation time to just five days. The cell was tested with the presence of real wastewater under the optimal temperature and pH and the results proved the capability of the manufactured cell in treating such contaminate in relatively short operation time. The COD reduction rate was above 60% indicated the ability of living microorganisms in digesting the wastewater producing electrical power with maximum values of 0.443 mV and 8.3 μ A for voltage and current, respectively.

تم في هذا البحث انشاء واختبار خلية وقود مايكروبية. تم تشغيل واختبار الخلية ذات الوعائين المربوطين بجسر ملحي بوجود مياه مخلفات مصنعة ومياه مخلفات حقيقية كمحلول لوعاء الانود. تمت دراسة تاثيرات درجة حرارة التشغيل والدالة الحامضية لمحلول الانود عن طريق رفع درجة الحرارة من 25 الى 30 درجة سيليزية وتغيير الدالة الحامضية من 6.7 الى 6.5. اظهرت النتائج ان رفع درجة الحرارة كان له تأثير ملحوظ في تقليل زمن التشغيل بينما خفض الدالة الحامضية كان سببا في رفع قيم التيار وفرق الجهد للخلية اضافة الى تقليل زمن التشغيل الى خمسة ايام فقط. تم اختبار الخلية تحت درجة الحرارة والدالة الحامضية الامثل بوجود مياه مخلفات حقيقية واظهرت النتائج قدرة الخلية المصنعة على معالجة هذه الملوثات خلال وقت تشغيل قصير نسبيا. بينت قياسات مستويات الاوكسجين المتطلبة كيمياويا انخفاضا وصل الى أكثر من 60 % مما يعزز قدرة الاحياء المجهرية الميكروبية في هضم مياه المخلفات وتحويلها الى طاقة كهربائية بمقدار فرق جهد 0.443 ملي فولت وتيار 8.3 مايكروامبير.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (1)


Year
From To Submit

2018 (1)

2011 (1)