research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
The development of normal air cooler to air cooler with four doors
دراسة تطوير المبردة الحالية إلى مبردة ذات أربعة أبواب

Author: مناضل عباس حسن
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2018 Volume: 16 Issue: 1 Pages: 152-165
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

In this research, an experimental study is conducted to design a proposed air cooler with four doors to suit the weather conditions in Iraq and especially in Karbala city. This is due to the inability of normal air cooler to reduce the weather’s temperature degree. The proposed air cooler is designed to increase the cooling effectiveness and to obtain temperature degrees within the comfort chart of human beings. For this purpose, two air coolers of the same size and type (Barfab) are configured and one of these air coolers is adjusted to become an air cooler with four doors, where the cold air is pushed from the bottom side. Study and experiment are conducted on both the proposed and the normal air coolers at the same time and within the same weather conditions, for comparison purposes. The experimental results of the performance of the air coolers show that the effectiveness of the proposed air cooler (30.3% - 75.4%) is higher than the effectiveness of the normal air cooler (15.2% - 70.4%) from 33oC to 42oC. However, the cooling effectiveness of both air coolers is the same at 42oC and 43oC. Accordingly, the high cooling effectiveness of the proposed air cooler compared with the normal one, in addition to its reduction in the temperature degrees of the air coming out of the air cooler, confirms the priority of utilising the proposed air cooler under most of the weather conditions of Iraq

في هذا البحث تم إجراء دراسة عملية لتصميم مقترح لمبردة هواء ذات أربعة أبواب بما يتلائم مع الظروف الجوية للعراق وخاصة في مدينة كربلاء وذلك بسبب عدم كفاية المبردة الاعتيادية في خفض درجة حرارة الهواء. تم تصميم المبردة المقترحة من أجل زيادة الفعالية التبريدية والحصول على درجات حرارة ضمن لوحة الراحة للإنسان. ولهذا تم تهيئة مبردتان من نفس النوع (برفاب) ومن نفس الحجم، وتم تحوير إحدهما إلى مبردة ذات أربعة أبواب لدخول الهواء ويتم دفع الهواء البارد من الأسفل. تم إجراء دراسة واختبار عملي لأداء المبردة المقترحة والاعتيادية في وقت واحد وضمن نفس الظروف جوية لغرض المقارنة. بينت النتائج العملية لأداء المبردتين بأن فاعلية المبردة المقترحة (75.4% - 30.3%) أعلى من فاعلية المبردة الاعتيادية (15.2% - 70.4%) عند درجات حرارة من 33oC إلى 42oC. إلا أن فاعلية المبردتين تتطابق عند درجات حرارة 42oC و43oC. لذلك فإن الفاعلية التبريدية العالية للمبردة المقترحة مقارنة مع المبردة الاعتيادية وخفضها الأكبر لدرجة حرارة الهواء الخارج من المبردة تؤكد أفضلية استخدام المبردة المقترحة في أغلب الظروف الجوية بالعراق.

Keywords


Article
دراسة تأثير تدفق الماء على الفاعلية التبريدية في المبردة المقترحة ذات الأبواب الأربعة

Author: مناضل عباس حسن
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 8 Pages: 188-205
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Previous research on the development of normal air cooler has been conducted into a proposed four-door air cooler. The results indicated that the effectiveness of the proposed air cooler (75.4% - 30.3%) was higher than the effectiveness of the normal air cooler (70.4% - 15.2%) at temperatures of (42oC - 33oC) but the effectiveness of both air coolers corresponded to the high temperature (42oC - 43oC). As well as the relative humidity of the air coming out of the proposed air cooler was higher than the normal air cooler at times of high temperature degrees (42oC - 33oC). However, the case is reversed at times of temperature degrees higher than (42oC). This means that the relative humidity of the air coming out of the proposed air cooler was lower. Therefore, it was necessary to study the effect of water flow on the cooling effectiveness in the proposed air cooler.A four-door air cooler with variable flow rate was designed and manufactured. A practical study and test was carried out and the optimal flow of water in the air cooler was determined to be 1800 L/hr. Another practical study and test was carried out to compare the performance of the normal air cooler against the proposed one with optimum water flow. The results showed that the proposed air cooler with the optimal water flow was the most effective and the most reduction of the temperature of the air inside the air cooler at various times of the day. It was noticeable that the difference between them increased in hot weather hours. The air coming out of the proposed air cooler with optimal water flow was more humid than the normal air cooler at different times of the day. The results indicate that the performance of the proposed air cooler with optimal flow is better than normal air cooler performance in most weather conditions in Iraq.

لقد تم إجراء بحث سابق حول تطوير المبردة الاعتيادية إلى مبردة مقترحة ذات اربعة أبواب وكانت النتائج إن فاعلية المبردة المقترحة (75.4% - 30.3%) أعلى من فاعلية المبردة الاعتيادية (70.4% - 15.2%)عند درجات حرارة (42oC - 33oC)، إلا إن فاعلية المبردتين تتطابق عند درجاتالحرارة العالية(43oC - 42oC) وكذلك الرطوبة النسبية للهواء الخارج من المبردة المقترحة كانتأعلى من المبردة الاعتيادية في الاوقات التي تكون فيها درجات الحرارة عالية (42oC - 33oC).أما في الأوقات التي تكون فيها درجات الحرارة أعلى من (42oC) فتكونالحالة معكوسة، أي الرطوبة النسبية للهواء الخارج من المبردة المقترحة أقل.فكان لابد من دراسة تأثير تدفق الماء في الفاعلية التبريدية في المبردة المقترحة.تم تصميم وتصنيع مبردة هواء ذات أربعة أبواب وذات معدل تدفق ماء متغير،وتم اجراء دراسة واختبار عمليين وتم تحديد التدفق الأمثل للماء في المبردة وهو (1800 L/hr).تم إجراء دراسة واختبار عمليينآخرين لمقارنة أداءكل من المبردة المقترحة ذات التدفق الأمثل مع المبردة الاعتيادية وكانت النتائج أن المبردة المقترحة ذات التدفق الأمثل هي الأعلى فاعلية والأكثر خفضا لدرجة حرارة الهواء داخل المبردة في مختلف أوقات اليوم ومن الملاحظ أن الفرق بينهما يزداد في ساعات الجو الحار. إن الهواء الخارج من المبردة المقترحة ذات التدفق الأمثل كان أكثر رطوبة من المبردة الاعتيادية في مختلف أوقات اليوم، كماتشير النتائج إلى أن أداء المبردة المقترحة ذات التدفق الأمثل أفضل من أداء المبردة الاعتيادية في أغلب الظروف الجوية بالعراق.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

Arabic and English (1)


Year
From To Submit

2018 (2)