Article
Effect of Additive of Expanded Polystyrene and Perlite on Some Mechanical Properties and Thermal Conductivity for Mass Concrete

Authors: Hamid H. Hussein --- Omar S. Saeed
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2016 Volume: 23 Issue: 1 Pages: 78-86
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

In this research, the major problem of mass concrete (Differences in Temperature) was studied. Expanded polystyrene and perlite were added in different percentages to investigate the effects on some mechanical properties and thermal conductivity of concrete. Two stages of work were performed.In first stage, reference mix was designed at proportion (1cement: 1.41sand: 2.72gravel) with (0.4) water cement ratio. Four tests were conducted, these tests including density, compressive strength, flexural strength and thermal conductivity through exponential equation depending on dry density. In the second stage, polystyrene beads and perlite were added as volumetric ratio with (10, 15, 20, 25, and 30) percentages to the original size of reference mix and conducted the tests and study their effects .The results showed a significant improvement in thermal insulation and reduced thermal conductivity (40 , 22) % by using (30) % of polystyrene and perlite respectively. The decreasing in some mechanical properties can be seen and this decreasing did not have serious effects on the design efficiency of the structure which conformed with the specifications.


Article
Evaluation of the local scour downstream untraditional bridge piers
تقويم النحر الموضعي مؤخر دعامات الجسور غير التقليدية

Authors: . Hamid H. Hussein --- Inam A. K. Juma --- Nashwan I. Hammo
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2012 Volume: 16 Issue: 3 Pages: 36-49
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The reduction of local scour downstream bridge piers got a massive concentration by several studies. In this study the D/S edge of the rectangular section semicircular bridge pier was reduced. This reduction was built to determine its influence on the local scour D/S these piers. Four models of the piers were manufactured from thermo-stone. The upstream semicircle diameter was fixed by a 10 cm, while the D/S diameter was changed to 4,6,8 and 10 cm . The experimental results provide evidence that the reduce of the D/S diameter of the pier leads to decrease the D/S scour depth and length . Moreover, in its place the sand was noticeably deposited D/S the pier. The experimental results was used to develop two liner empirical relations the first to estimate the ratio of maximum scour depth to U/S diameter of the pier ds/d1 . While the second to estimate the ratio of the length of scour to U/S diameter of the pier X/d1 , in terms of the ratio for D/S diameter of the pier to U/S diameter of the pier d2/d1 , length of the scour U/S the pier to D/S diameter Z1/d2, maximum width of scour to D/S diameter Z2/d2 , maximum height of sand deposition D/S of the pier to D/S diameter y/d2 and Froude number Fr. Furthermore, the two empirical relations were compared with the results of the artificial neural network (ANN). The utilize of ANN techniques yields superior results for predicting the maximum depth and length of scour D/S these piers

إن تقليل النحر الموضعي مؤخر دعامات الجسور قد اخذ اهتمام كبير من قبل العديد من الدراسات. في هذه الدراسة تم تصغير قطر نهاية الدعامة مستطيلة المقطع ذات النهايات نصف دائرية. أجري هذا التصغير لغرض قياس تأثيره على النحر الموضعي مؤخر الدعامات . تم اختيار أربعة نماذج صنعت من مادة الثرموستون. الجزء نصف دائري مقدم الدعامة وبقطر 10 سم لم يتم تغيره , بينما تم تغير أقطار مؤخر الدعامات وبأقطار 8,6,4 و10سم . أثبتت النتائج المختبرية بأن تصغير قطر مؤخر الدعامة أدى إلى تقليل عمق وطول النحر الموضعي . بالإضافة إلى ذلك , وبدلا عنه فأن الرمل قد ترسب وبوضوح مؤخر الدعامة. كما استخدمت النتائج المختبرية لاستنباط علاقتين وضعيتين خطيتين الأولى لنسبة العمق الأقصى للنحر إلى قطر مقدم الدعامة ds/d1 . بينما الثانية لنسبة طول النحر إلى قطر مقدم الدعامة X/d1 وبدلالة نسبة قطر مؤخر الدعامة إلى قطر مقدمهاd2/d1 , نسبة طول النحر مقدم الدعامة إلى قطر مؤخرها Z1/d2 , نسبة أقصى عرض للنحر إلى قطر مؤخرها Z2/d2 , نسبة أقصى ارتفاع لترسيب الرمل مؤخر الدعامة إلى قطر مؤخرها y/d2 و رقم فرود Fr . بالإضافة إلى ذلك فأنه تم مقارنة العلاقتين الوضعيتين مع نتائج الشبكة العصبية الاصطناعية ANN . أن استخدام تقنيات ANN أعطى تفوق بالنتائج للتنبوء بعمق وطول النحر مؤخر هذه الدعامات.


Article
Effect of Hybrid Fibers on the Mechanical Properties of High Strength Concrete
تأثير الألياف الهجينة على الخواص الميكانيكية للخرسانة عالية المقاومة

Author: Hamid H. Hussein*, Saeed K. Rejeb**, Hayder T. Abd***
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2014 Volume: 21 Issue: 1 Pages: 42-52
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

In this study, high strength concrete of 75 MPa compressive strength was investigated. The experimental program was designed to study the effect of fibers and hybrid fibers (steel and polypropylene fibers) on the fresh (workability and wet density) and hardened properties (compressive strength, splitting strength, flexural strength and dry density) of high strength concrete. Results show that decreases in slump flow of all concrete mixtures containing steel, polypropylene and hybrid fibers compared with control mix (0% fiber). Hybrid high strength concrete with steel and polypropylene fibers showed superior compressive, splitting, flexural strengths over the others concrete without or with single fibers content.The test results indicate that the maximum increase in compressive and flexural strengths are obtains with the hybridization ratio (70%steel + 30% polypropylene) and were equal to 14.54% and 23.34% respectively, compared with the control mix. While, the maximum increase in splitting tensile strength with (100% steel fiber + 0 polypropylene) is 21.19%.

في هذا البحث تم دراسة الخرسانة عالية المقاومة ذات مقاومة انضغاط (75 MPa). صمم البرنامج العملي لدراسة تأثير الألياف والألياف الهجينة (ألياف حديدية وألياف البولي بروبلين) على الخواص الطرية (قابلية التشغيل والكثافة الرطبة) والخواص المتصلبة (مقاومة الانضغاط, مقاومة الانشطار , مقاومة الانحناء والكثافة الجافة) للخرسانة عالية المقاومة. نتائج الفحوصات بينت نقصان في الهطول لكل الخلطات الحاوية على ألياف الحديد, ألياف البولي بروبلين والألياف الهجينة مقارنة مع الخلطة المرجعية غير الحاوية على ألياف. الخرسانة العالية المقاومة الهجينة بألياف الحديد وألياف البولي بروبلين أظهرت مقاومة عالية في الانضغاط, مقاومة الانشطار ومقاومة الانحناء أكثر من الخرسانة غير الحاوية على ألياف أو الحاوية على ألياف من نوعية واحدة. أظهرت نتائج الفحوصات بان أعلى نسب زيادة في مقاومة الانضغاط ومقاومة الانحناء كانت في الخلطة الحاوية على ألياف هجينة (%70 ألياف حديد + %30 ألياف بولي بروبلين) وكانت نسب الزيادة %14.54 و % 23.34 على التوالي, مقارنة مع الخلطة الخرسانية المرجعية الغير حاوية على ألياف. بينما أعلى نسبة زيادة في مقاومة الانشطار كانت في الخلطة الحاوية على (%100 ألياف حديد + %0 ألياف بولي بروبلين) وكانت نسبة الزيادة %21.19.


Article
Improving the hydraulic performance of single step broad-crested weirs

Authors: Saleh J. S. Shareef --- Inam A. K. Juma --- Hamid H. Hussein
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2011 Volume: 7 Issue: 1 Pages: 1-12
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Abstract

In this study the hydraulic performance of single step broad-crested weir was improved. Through analyzing the parameters that have effect on the shape of the step and its influence on the flow characteristics, and energy dissipation percent (E%) downstream (D/S) of the weir. The differential equation of gradually varied flow for the water surface profile over the weir was solved analytically .Furthermore, empirical relations for E% and discharge coefficient (Cd) due to the affecting factors were derived .The results showed that the weir model when the ratio of the length of D/S step to the length of the weir L2/L1=0.5 gives a higher E% in comparison with other weir models. Three types of flow regimes were observed, nappe flow below 350 cm3 /s/cm, transition flow 350-700 cm3/s/cm and skimming flow upper than 700 cm3/s/cm . The comparison between calculated values by the differential equation of gradually varied flow and experimental values gives a good agreement, the maximum difference is about 7%.Two empirical relations were obtained, the first to estimate Cd in terms of the ratio for upstream U/S water head to U/S weir height H/P1 and L2/L1. While the second relation to estimate E% in terms of the ratio for D/S water head to U/S weir height h/P1, L2/L1 and the Froude number Fr2 with a high correlation coefficient .
Key words: Hydraulics; weirs ; performance ; dissipation energy.

Keywords


Article
Mechanical, thermal and acoustical properties of concrete with fine Polyvinyl chloride (PVC)
الخصائص الميكانيكية والحرارية والصوتية للخرسانة باستخدام البولي فينيل كلوريد

Authors: Hamid H. Hussein حامد حسين --- Osama A. Eedan اسامة عيدان --- Mahmoud K. Ahmed محمود احمد
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2017 Volume: 11 Issue: 2 Pages: 81-91
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

This study addressed some important tests for concrete including thermal, acoustic insulation and some mechanical behaviour of concrete containing granular Polyvinyl Chloride (PVC) waste as a sand replacement. The PVC waste was collected from a plant of manufacturing PVC doors and windows, was used to replace some of fine aggregate at ratios of 2.5%, 5%, 7.5%, 10%, 12.5% and 15% by weight Properties that studied are thermal conductivity, acoustic insulation slump, fresh density, dry density, compressive strength, flexural strength, and splitting tensile strength. Curing ages of 7, 28, and 56 days for the concrete mixtures were applied in this work. From the results of this study, it is suggested that using of 12.5% fine PVC as a sand replacement by weight can improve thermal insulation to about 82.48% more than concrete without plastic waste Acoustic insulation is about 43.09% more than reference mix and it satisfies the requirement of ACI 213R 2014 for structural lightweight concrete.

تناولت هذه الدراسة بعض الفحوصات المهمة للخرسانة، السلوك الحراري والعزل الصوتي وبعض الفحوصات الميكانيكية للخرسانة التي تحتوي على حبيبات النفايات البولي فينيل كلوريد (PVC) كبديل للرمل الطبيعي، تم جمع النفايات البلاستيكية من معامل تصنيع الأبواب والشبابيك البلاستيكية، وكانت تستخدم لتحل محل الركام الناعم في نسب 2.5٪، 5٪، 7.5٪، 10٪، 12.5٪ و15٪ كنسبة وزنية. الخواص التي درست هي التوصيل الحراري والعزل الصوتي والهطول والكثافة الطرية والكثافة الجافة، مقاومة الانضغاط ومقاومة الانحناء ومقاومة الشد الغير مباشرة، اعمار المعالجة كانت 7 و28 و56 يوم للخلطات الخرسانية في هذا البحث. من خلال نتائج هذه الدراسة، نقترح استخدام 12.5% من فضلات (PVC) الناعم كنسبة مئوية وزنية لاستبدال الرمل يمكن تحسين العزل الحراري (%82.48 ) أكثر من الخرسانة التي لا تحتوي على النفايات البلاستيكية وكذلك يحسن العزل الصوتي (43.09%) أكثر من الخرسانة المرجعية وتلبي متطلبات ACI 213R 2014 للخرسانة الانشائية خفيفة الوزن حاملة.


Article
Flow Characteristics and Energy Dissipation Over Single Step Broad – Crested Weirs
خصائص الجريان وتبديد الطاقة فوق الهدارات مفردة الدرجة ذات القمة العريضة

Loading...
Loading...
Abstract

ABSTRACT The main purpose of traditional broad - crested weir is to rise and control upstream (U/S) water level. In this study a new performance was added to this weir, by making it as an energy dissipater. In order to study the energy dissipation percent (E%), the downstream (D/S) height of the weir (12 cms U/S height) was reduced four times as 9.8,8,6and3.8cms.Thirty experiments were performed in a laboratory horizontal channel of 12 m length, 0.5 m width and 0.45 m depth for a wide range of discharge. A mathematical model to compute theoretical coefficient of discharge (Cdth) was modified depending upon momentum equations. Experimental results gave a high validity to the computed values of the proposed model. On the other hand, three empirical non dimensional relations were obtained. The first is liner relation to estimate the ratio for D/S water head to U/S weir height (h/P1) in terms of the ratio for U/S water head to U/S weir height (H/P1). The second relation is nonlinear relation to estimate the discharge coefficient (Cd) in terms of H/P1 and the ratio of D/S weir height to U/S weir height (P2/P1). While the third relation is to estimate E% in terms of h/P1and P2/P1 with high correlation coefficients. The experimental results of the study showed that E% increased up to 46%. Furthermore, Cd was improved and gets higher values in comparison with traditional weirs. Key words: Hydraulic structure; Broad crested weirs ; Energy dissipation.

ملخـــص إن الغرض الرئيسي من الهدار ذو القمة العريضة التقليدي هو رفع مستوى الماء والسيطرة عليه في مقدم الهدار . في هذه الدراسة تم أضافة أداء جديد لهذا الهدار من خلال تبديده لطاقة جريان الماء.ولدراسة نسبة تبديد طاقة الجريان (E% )تم تخفيض منسوب مؤخر سطح الهدار(والذي ارتفاعه في المقدم 12سم) أربعة مرات وبمناسيب3.8,6,8,9.8 سم. تم اختبار ثلاثين تجربة في قناة مختبرية افقية ذات طول 12م وعرض0.5 م وعمق 0.45 م ولمدى واسع من التصاريف. تم اشتقاق علاقة رياضية لحساب معامل التصريف النظري (Cdth) بالاعتماد على معادلات زخم الطاقة ، وأعطت النتائج المختبرية تطابق جيد مع القيم المحسوبة بهذه المعادلة . من جانب أخر تم أستنباط ثلاث علاقات وضعية لابعدية. الأولى علاقة خطية لحساب ( h/P1) بدلالة ( H/P1 ). أما العلاقة الثانية فكانت غير خطية لحساب Cd بدلالة نسبة عمق الماء مقدم الهدار الى ارتفاع الهدار في المقدم (H/P1 ) ونسبة ارتفاع مؤخر الهدار الى ارتفاع الهدار في المقدم (P2/P1 ). و كانت العلاقة الثالثة غير خطيه أيضا لحساب E% بدلالة نسبة عمق الماء مؤخر الهدار الى ارتفاع الهدار في المقدم (h/P1) ونسبة ارتفاع مؤخر الهدار الى ارتفاع الهدار في المقدم (P2/P1 ) وبمعاملات ارتباط عالية . أظهرت النتائج المختبرية لهذه الدراسة بأن E% أزدادت بنسبة 46% . بالاضافة الى ذلك تحسن أداء هذا النوع من الهدارات حيث أزدادت قيم معامل التصريف Cd مقارنة مع الهدار ذو القمة العريضة التقليدي .