research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
Experimental Comparison Between Conventional Coolants and (TiO2/Water) Nano fluid to select the best Coolant for Automobiles in Iraq's Summer Season

Author: Abdulmunem R. Abdulmunem
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 5 Part (A) Engineering Pages: 912-926
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This work, presentsnanofluids as a new coolant technology in automobile engines compared with other conventional coolants (Ethylene glycol/water(antifreeze), distilled water) experimentally.The increase in thermal conductivity of the base fluid (water) by adding nanoparticles in certain ratios led to more absorption of heat from engine block. The experimental results indicated that the drooping in exit engine coolant temperatures was about(18.5%) by using (0.3%TiO2/water)nanofluid, and about (9%) by using distilled water comparative with Ethylene glycol/water(50/50) at the test end. The increasing in radiator(heat exchanger) effectiveness was about (51%) with using nanofluid, and about (29%) with using distilled water comparative with Ethylene glycol/water(50/50) at the test end. The results indicated also that the increasing in Nusselt’s number at entrance of radiator hose was about (42.8%) with usingnanofluid and about (30.5%) with using distilled water compared with Ethylene glycol/water(50/50).This led to increase convection heat transfer coefficient at entrance of radiator hoseby about (65%) with using nanofluidand about (49.5%) with using distilled water compared with Ethylene glycol/water (50/50).


Article
NUMERICAL AND EXPERIMENTAL INVESTIGATION OF USING INNER LONGITUDINAL FINS IN A RECTANGULAR ENCAPSULATION ON THE PCM MELTING BEHAVIORS
تحقيق عددي وعملي لاستخدام الزعانف الطوليةً داخل التغليف المستطيل على سلوك الذوبان للمواد المتغيرة الطور

Authors: Jalal M. Jalil --- Abdulmunem R. Abdulmunem --- Akram H. Abed
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 3 Pages: 139-154
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

In this work, the effect of using inner longitudinal fins in a rectangular encapsulation on the PCM (paraffin wax) melting process was studied numerically and experimentally. An enthalpy transformation method was used in the numerical solution to transfer the equation of energy into a nonlinear equation with a single dependent variable H (enthalpy) by using FORTRAN (F90) program. The discretization of energy equation with phase change problem was solved in three dimensions by using the control-volume finite-difference. A comparative study was satisfactory made between the numerical results of the enthalpy method and the experimental results with approximation ratio (10%) along the test time (90) minute. The experimental results indicated that when using inner longitudinal fins in the same rectangular encapsulations led to decrease absorber surface temperature by 10 oC. This is because part of heat energy was injected deeply in the paraffin wax by the fins. This led to accelerate melting of PCM (paraffin wax) by about 12 min in section A which is under the effect of one fin, at a distance 3 cm from the heat absorber surface. While, at section B, where two longitudinal fins have effect, melting is decelerated by about 12 min.

: في هذا العمل تم دراسة تاثير استخدام الزعانف الداخلية الممتدة طوليا في التغليف المستطيل على سلوك الانصهار لمادة متغيرة الطور (شمع البرافين) عددياً وعملياً. استخدمت طريقة الانثالبي في الحل العددي لتحويل معادلة الطاقة الى معادلة لا خطية مع متغير واحد وهو الانثالبي(H) باستخدام برنامج فورتران (F90). تم حل معادلة الطاقة ثلاثية الابعاد مع تغير الطور باستخدام الحجوم المحددة و الفروقات المتناهية. كانت المقارنة مقبولة بين النتائج العددية لطريقة للانثالبي مع النتائج العملية بنسبة تقارب (10%) على طول مدة الفحص (90) دقيقة. بينت النتائج العملية انه عند استخدام الزعانف الداخلية الممتدة طوليا لنفس التغليف المستطيل ادى الى انخفاض في درجة حرارة السطح الممتص للحرارة حوالي (10 درجة سيليزية) وّلك بسبب ان جزء من هذه الطاقة الحرارية تحقن داخليا في شمع البرافين بواسطة الزعانف, وهذا يؤدي الى التعجيل في زمن الذوبان للمادة المتغيرة الطور (شمع البرافين) حوالي (12 دقيقة) في المقطع (A) على مسافة (3 سنتيمتر) من السطح الماص للحرارة مقارنة مع التغليف المستطيل بدون زعانف. لكن عند المقطع (B) الواقع تحت تاثير زعنفتان طوليتان زمن الذوبان ارتفع حوالي (12) دقيقة مقارنة مع المقطع (A) الواقع تحت تأثير زعنفة واحدة


Article
PASSIVE COOLING BY UTILIZING THECOMBINED PCM / ALUMINUM FOAM MATRIX TO IMPROVE SOLAR PANELS PERFORMANCE: INDOOR INVESTIGATION
التبريد السلبي من خلال الاستفادة من مدمج PCM / مصفوفة الالمنيوم الرغوي لتحسين اداء الالواح الشمسية : تحقيق مختبري

Loading...
Loading...
Abstract

In this study, utilizing the PCM latent heat of fusion to absorbing the heat energy from photovoltaic panels was done. This method works as a passive cooling to regulate the PV panel’s temperature in hot climate regions. To enhance the important effective physical properties such as thermal conductivities (keff) for this material, aluminum foam matrix was used with paraffin wax. This led to good temperature distribution inside PCM and more heat absorption from PV panel. The experimental results indicated that the PV panel temperature drooped from (61.39 oC) to (46.2 oC) by using PCM only, and to (39.58oC) by using PCM/Aluminum foam matrix at the test end, (i.e. the percentage drooping of PV panel temperature was (25.03%) by using PCM only, and it was (35.51%) by using PCM/Aluminum foam matrix). This droop in temperature enhances the electrical performance of PV panel such as maximum power generated, fill factor (FF), etc. The improving in electrical efficiency of PV panel at the test end was from (10.19%) to (12.37%) with using PCM only, and to about (13%) with using PCM/Aluminum foam matrix.

في هذه الدراسة, تم استثمار الحرارة الكامنة للانصهار للمواد المتغيرة الطور PCM لامتصاص الطاقة الحرارية من الالواح الكهروضوئية , هذه الطريقة تعمل كطريقة تبريد سلبي لتنظيم درجة حرارة الالواح الكهروضوئية في المناطق ذات المناخ الحار. لتحسين الخصائص الفيزيائية الفعالة المهمة كالموصلية الحرارية (keff) لهذه المادة, تم استخدام مصفوفة الالمنيوم الرغوي مع شمع البارافين, ادى هذا الى توزيع درجات حرارة جيد داخل المادة المتفيرة الطور PCM والى زيادة في امتصاص الحرارة من اللوح الكهروضوئي. بينت النتائج العملية ان درجة حرارة اللوح الكهروضوئي انخفضت من(61.39 oC) الى (46.2 oC) باستخدام المادة المتغيرة الطور PCM فقط, وانها انخفضت الى (39.58oC) باستخدام المادة المتغيرة الطور مع مصفوفة الالمنيوم الرغوي في نهاية الفحص,(بمعنى اخر, النسبة المئوية لانخفاض درجة حرارة اللوح الكهروضوئي كانت (25.03%) باستخدام ال PCM فقط, وكانت (35.51%) باستخدام المادة المتغيرة الطور مع مصفوفة الالمنيوم الرغوي). هذا الانخفاض بدرجات الحرارة ادى الى تحسين بالاداء الكهربائي للوح الكهروضوئي كاعلى قدرة كهربائية متولدة, عامل الاملاء(FF) , الخ. التحسين بالكفائة الكهربائية في نهاية الفحص كانت من (10.19%) الى (12.37%) باستخدام ال PCM فقط, والى حوالى (13%) باستخدام المادة المتغيرة الطور مع مصفوفة الالمنيوم الرغوي.


Article
Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat exchanger: An Experimental Study

Authors: Akram H. Abed --- Nassr F. Hussein --- Abdulmunem R. Abdulmunem
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 11 Part (A) Engineering Pages: 1158-1164
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The main purpose of the present investigation is enhancing heattransfer rate in a tube heat exchanger by using V-shape twisted Jaws. Theair is used as a working fluid and pumped through the test section withdifferent values of Reynolds number (6000 - 19500), while the heat flux hasbeen selected as a constant boundary condition around the tube section. Inthis study, two type of twisted jaw turbulators are used with two twistedratio (TR= 2 & 4) as well as, the effect of using different numbers ofturbulators (N= 6, 8 and 10) inside test section with equal distancesbetween pieces are studied. The results indicated that, using augmentationswith TR=2 gives better heat transfer rate and thermal performance factorcomparing with the other case TR=4. The maximum rate of heat transfer isachieved in case of N=10 by an increased 160.29% for TR=2 and 102% forTR=4 comparing with plain tube case. In addition, results show that thevalues of thermal performance factor exceed the unity and shows uptrendbehavior with rising numbers of turbulators indicating to feasibility of usingthese turbulators practically.


Article
INVESTIGATION OF COMBINATION BETWEEN LATENT AND SENSIBLE HEAT STORAGE MATERIALS ON THE PERFORMANCE OF FLAT PLATE SOLAR AIR HEATER
دراسة التاثير المشترك لمادة الخزن الحراري الكامن والمحسوس كمادة خزن حراري جديدة على اداء سخان الهواء الشمسي المستوي

Loading...
Loading...
Abstract

In this work, a combination between latent heat storage materials (LHSm) and sensible heat storage materials (SHSm) as new storage heat material in flat plate solar air heater was tested experimentally. PCM (paraffin wax) at a certain ratios (10%) and (20%) were used as LHSm with a pure cement (base material) as SHSm. The experimental tests was done indoor at irradiance of (1000W/m2) with forced convection, the mass flow rate of air are (0.5kg/min) and (1.13kg/min). The results indicated that the enhancing thermo-physical properties of adding pure cement by a certain ratios of paraffin wax led to enhancement in thermal energy stored. The percentage increasing in storage heat duration time was (29%) for compound cement with (10%PCM), (38.4%) for compound cement with (20%PCM), compared with pure cement at (0.5kg/min) air mass flow rate. And at (1.13kg/min) air mass flow rate, it was (33.3%) for compound cement with (10%PCM) and (52.6%) for compound cement with (20%PCM) compared with pure cement.

في هذا العمل, الجمع بين مادة الخزن الحراري الكامن و مادة الخزن الحراري المحسوس كمادة خزن حراري جديدة في سخان الهواء الشمسي مستوي الصفيحة حضرت وفحصت عملياً. استخدمت مادة متغيرة الطور(شمع البارافين) بنسب محددة (10%) و (20%) استخدمت كمادة خزن حراري كامن مع السمنت النقي (مادة اساسية) كمادة خزن حراري محسوس. الفحوصات العملية تمت مختبرياً تحت تعرض اشعاع ( 1000واطمتر مربع) مع حمل قسري (0.5 كغدقيقة) و ( 1.131كغدقيقة). بينت النتائج ان التحسين بالخصائص الفيزيائية-الحرارية للسمنت النقي بإضافة نسب محددة من شمع البارافين ادى الى تحسين بالطاقة الحرارية المخزونة. كانت النسبة المئوية للزيادة بزمن التخزين الحراري (29%) لمركب السمنت مع (10% مادة متغيرة الطور), ( 38.4 %) لمركب السمنت مع (20% مادة متغيرة الطور) مقارنة مع السمن النقي عند معدل تدفق هواء كتلي (0.5كغدقيقة). و عند معدل تدفق هواء كتلي (1.13 كغدقيقة), كانت (33.3%) لمركب السمنت مع (10% مادة متغيرة الطور) و (52.6%) لمركب السمنت مع (20% مادة متغيرة الطور) مقارنة مع السمن النقي.


Article
Effect of Colored Filters on PV Panels Temperature and Performance under Baghdad Meteorological Condition
تأثير الفلاتر الملونة على حرارة واداء االلواح الكهروضوئية تحت الظروف الجوية لمدينة بغداد

Authors: Abdulmunem R. Abdulmunem --- Abdullateef A. Jadallah --- Hisham A. Hoshi --- Mohammed H. Jabal
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2018 Volume: 25 Issue: 4 Pages: 46-50
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

In this work, the influence of colors of filters upon the photovoltaic panels rising temperature and electrical performance was studied under Baghdad Meteorological Condition. Basing on the energy analysis of a photovoltaic solar system and by using the photonic theory, the available energy on the PV plane system has been evaluated. Seven colored filters each with (85W) PV modules were used in this case study, to reveal the impact of colored filters upon the electrical productivity of PV panel with the variation in the temperature caused by these filters. There is themain issue of this work is to show how the performance of PV module by imposing colored filter and hence how and to how much improve it by reducing the cell temperature in hot climate. Outcomes showed that the PV technology is affected by the color filters. In other words, red filter gives light have least photons energy, and violet filter gives light have the most photons energy and green is between the two. So, red colors filter gives highest PV panel temperature comparative with others filters, while violet color filter was the lowest. PV module with the lowest temperature colored filter gives the best electrical performance than others.

في هذا العمل، تمت دراسة تأثير ألوان الفالتر على ارتفاع درجة حرارة واألداء الكهربائي لأللواح الكهروضوئية تحت الظروف الجوية لمدينة بغداد . على أساس تحليل الطاقة لنظام الطاقة الشمسية الضوئية وباستخدام النظرية الفوتونية، تم تقييم الطاقة المتاحة على نظام اللوح الكهروضوئي .تم استخدام سبعة فالتر ملونة مع كل نموذج كهروضوئي )85 واط( في هذه الحالة الدراسية، للكشف عن تأثير الفالتر الملونة على إنتاجية األلواح الكهروضوئية الكهربائية مع التغير في درجة الحرارة التي تسببها هذه الفالتر. القضية الرئيسية لهذا العمل هو إظهار كيفية أداء النموذج الكهروضوئي عن طريق فرض الفلترة الملونة وبالتالي كيف وإلى اي مدى يتم التحسين عن طريق خفض درجة حرارة الخلية في المناخ الحار .أظهرت النتائج أن التكنولوجيا الكهروضوئية تتأثر بالفالتر الملونة . وبعبارة أخرى، الفلتر األحمر يعطي ضوء له أقل طاقة فوتونية، ويمنح الفلتر البنفسجي ضوء له اعلى طاقة فوتونية واالخضر بين االثنين. لذا ، الفلتر األحمر اللون يعطي أعلى درجة حرارة للوح الكهروضوئي مقارنة مع بقية الفالتر ، بينما كان الفلتر البنفسجي اللون هو األقل. النموذج الكهروضوئي مع الفلتر الملون االقل درجة حرارة يعطي أفضل أداء كهربائي من البقية.


Article
APPLICABLITY OF USING THERMAL STORAGE MATERIALS IN SOLAR AIR HEATER
امكانية استخدام المواد الخازنة للحرارة في السخان الشمسي الهوائي

Loading...
Loading...
Abstract

Solar air heater (SAH) is more suitable for residential space heating in winter season and in drying crops. This work presents thermal performance of flat plate SAH with and without thermal storages. A forced convection solar collector (FCSC) integrated with different sensible heat storage materials (sand, concrete, pure cement) has been developed and tested to evaluate its performance under meteorological conditions of Baghdad, Iraq. System consists of three flat plate solar air heaters with different heat storage materials, and the fourth without storage heat material. All collectors are supplied with centrifugal blower. The experimental results indicated that the pure cement gives better thermal performance than other storage heat materials (sand, concert), the pure cement gives heat along (240 min) after (6:30 PM), but the duration was (170 min) and (65 min) for concrete and sand respectively. The air flow rate is more affect on both outlet air temperature storage heat times, where studied the effect of three air velocities (0.8m/s, 1.4m/s and 2.1m/s) on SAH performance with best thermal storage heat material (pure cement), the increase in outlet air velocity leads to decrease in both outlet air temperature and storage time of thermal energy.

السخان الشمسي الهوائي مناسب للتدفئة السكنية في فصل الشتاء و كذلك في تجفيف المحاصيل. يبين هذا العمل الاداء الحراري للسخان الشمسي الهوائي مستوي الصفيحة مع المواد الخازنة للحرارة وبدونها. دمج مجمع الطاقة الشمسية ذو انتقال الحرارة بالحمل القسري مع مواد الخزن الحراري المختلفة (رمل, خرسانة, سمنت نقي) وقد تم تطوير وتقييم ادائها عند الظروف الجوية لمدينة بغداد,العراق. يتكون النظام من ثلاثة سخانات شمسية للهواء مستوية الصفيحة مع مواد الخزن الحراري المختلفة, والرابع بدون مادة خزن حراري. جميع المجمعات جهزت بمروحة طاردة مركزية. بينت النتائج العملية ان السمنت النقي اعطى افضل اداء حراري من بقية المواد الخازنة للحرارة (رمل, كونكريت), اعطى السمنت النقي حرارة على طول (240 دقيقة) بعد ( 6:30 مساءاً), بينما كانت المدة ( 170 دقيقة) و (65 دقيقة) للكونكريت و الرمل على التعاقب. ان معدل جريان الهواء يؤثر على كل من درجة حرارة الهواء الخارج واوقات الخزن الحراري, حيث تم دراسة تاثير ثلاث سرع للهواء الخارج (0.8 مثا, 1.4 مثا و 2.1 مثا) على اداء السخان الشمسي الهوائي مع افضل مادة خزن حراري (سمنت نقي), ان زيادة سرعة الهواء الخارج من السخان الشمسي الهوائي يؤدي الى انخفاض كل من درجة حرارة الهواء الخارج و زمن التخزين للطاقة الحرارية.


Article
Effect of Using Combined Square Nozzle & winglet with Helical Tape on Thermal Characteristics in Tube Heat Exchanger
تأثير استخدام المركب لفوهة مربعة ذو جنيح مع شريط حلزوني على الخصائص الحرارية في أنبوب مبادل حراري

Loading...
Loading...
Abstract

Influence of combined square nozzle with helical tape inserted in a constant heat flux tube on heat transfer enhancement for turbulent airflow for Reynolds number ranging from 7000 to 14500 were investigated experimentally. Three different pitch ratios for square nozzle (PR = 5.8, 7.7 and 11.6) according to three different numbers of square nozzle (N = 3, 4 and 5) and constant pitch ratios for helical tape were used. The results observed that the Nusselt number and friction factor for combination with winglets were found to be up to 33.8 % and 21.4 %, respectively higher than nozzle alone for pitch ratio PR=5.8. The maximum value of thermal performance for using combination with winglets was about 1.351 for pitch ratio= 5.8. Nusselt number and friction factor correlations from experimental data were developed for turbulent flow.

تمت دراسة عملية تأثير اتحاد فوهة مربعة ذات جنيح مع شريط حلزوني مدرج في أنبوب ذي تدفق حراري ثابت على تحسين نقل الحرارة لتدفق هواء مضطرب ولعدد رينولدز يتراوح من 7000 إلى 14500.حيث تم استخدام ثلاث نسب خطوة مختلفة للفوهة المربعة وهي (5.8, 7.7 و11.6) على وفق ثلاثة أعداد مختلفة من الفوهات المربعة وهي (5, 4 و3) واستخدامت نسبة ثابتة واحدة للشريط الحلزونية. ولاحظت النتائج أن عدد ناسلت وعامل الاحتكاك للاتحاد مع الفوهة ذات الجنيح وجد أنه يصل إلى 33.8% و 21.4% على التوالي أعلى من الفوهة وحدها لنسبة خطوة هي (5.8). كانت القيمة القصوى للأداء الحراري لاستخدام الاتحاد مع الفوهة ذات الجنيح حوالي 1.351 لنسبة خطوة هي ( 5.8). تم تطويرعلاقات تجريبية لعدد ناسلت ومعامل الأحتكاك للنتائج التجريبية ولجريان مضطرب.

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (7)

Arabic and English (1)


Year
From To Submit

2018 (4)

2017 (1)

2016 (3)