research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Implementation of Power System Stabilizer Based on Conventional and Fuzzy Logic Controllers
تطبيق منظومة مثبت القدرة اعتمادا على النظام التقليدي والمسيطرات المنطقية المضببة

Authors: Hanan Mikhael Habbi حنان ميخائيل حبي --- Ahmed Alhamadani احمد عبد الكاظم الحمداني
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 3 Pages: 97-113
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

To damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. A suitable PSS model was selected considering the low frequencies oscillation in the inter-area mode based on conventional PSS and Fuzzy Logic Controller. Two types of (FIS) Mamdani and suggeno were considered in this paper. The software of the methods was executed using MATLAB R2015a package.

من اجل اخماد تذبذبات الترددات المنخفضة التي تحدث في الشبكة الكهربائية نتيجة اضطرابات معينة. تم تزويد محطات التوليد بمنظومة مثبت القدرة وهذه المنظومة من شانها تغذية اشارات استرجاعية مستقرة ساندة . ان تذبذب الترددات المنخفضة في نظام القدرة يمكن تصنيفه الى تذبذبات موقعية, تذبذبات المناطق المتداخلة ,تذبذبات المناطق التداخلية.اختيار موديل منظومة مثبت القدرة مع الاخذ بنظر الاعتبار تذبذبات الترددات القليلة في المناطق التداخلية اعتمادا على النظام التقليدي والمسيطر المنطقي المضبب. وتم استخدام نوعان من نظام التداخل المضبب وهما مامداني وسوجينو. البرمجيات التي استخدمت بتنفيذ هذه الطرق هو برنامج ماتلاب 2015.


Article
Power System Stabilizer PSS4B Model for Iraqi National Grid using PSS/E Software
نظام مثبت القدرة متعدد المستويات PSS4B المطبق على الشبكة الوطنية العراقية باستخدام برنامج القدرة للمحاكاة PSS/E

Authors: Hanan Mikhael Habbi حنان ميخائيل داود --- Ahmed Alhamadani احمد عبد الكاظم الحمداني
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 5 Pages: 29-45
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

To damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. Double input multiband Power system stabilizers (PSSs) were used to damp out low-frequency oscillations in power system. Among dual-input PSSs, PSS4B offers superior transient performance. Power system simulator for engineering (PSS/E) software was adopted to test and evaluate the dynamic performance of PSS4B model on Iraqi national grid. The results showed that after installing the PSS in a specific plant the oscillation of rotor angle, bus frequency, speed, power flow is better than without PSS during the disturbances that occurred during the simulations. All the PSS/E simulation and tests were done in the National dispatch center (NDC) laboratory, Ministry of Electricity.

من اجل اخماد تذبذبات الترددات المنخفضة التي تحدث في الشبكة الكهربائية نتيجة اضطرابات معينة. تم تزويد محطات التوليد بمنظومة مثبت القدرة وهذه المنظومة من شانها تغذية اشارات استرجاعية مستقرة ساندة . ان تذبذب الترددات المنخفضة في نظام القدرة يمكن تصنيفه الى تذبذبات موقعية, تذبذبات المناطق المتداخلة ,تذبذبات المناطق التداخلية .تم اختيار نوع ثنائي المدخلات ومتعدد المستويات من اجل اخماد تذبذب الترددات المنخفضة للمستويات الثلاثة العالي والمتوسط والمنخفض وهذا النوع اللذي تم اختياره يعرف باسم PSS4B ويمتاز هذ النوع من انظمة مثبت القدرة بادائه الانتقالي العالي.تم اعتماد برنامج محاكاة نظام القدرة الهندسي لتقييم اداء نظام مثبت القدرة للنوع اللذي تم اختياره اعلاه على جزء من الشبكة الوطنية العراقية وقد اظهرت النتائج بعد تنصيب نظام مثبت القدرة في احد المحطات بان التذبذب في زاوية الدوار ,تردد القضيب, السرعة, والقدرة المنتقلة افضل مما في حالة بدون تنصيب نظام مثبت القدرة . تم اجراء هذه المحاكاه في الممختبر الحاسوبي في مركز التشغيل والتحكم , وزارة الكهرباء العراقية.