research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
THE INFLUENCE OF AIR DISTRIBUTORS ON HEAT TRANSFER COEFFICIENT IN FLUIDIZED BED OF HEAT PIPE HEAT EXCHANGER

Author: Amer M. Al-Dabagh
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2006 Volume: 19 Issue: 2 Pages: 135-149
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

Heat exchanger made of heat pipes elements immersed in a fluidized bed represents one of the most economic devices used in recovery of waste heat energy. In the present work ten copper heat pipes (each 22.2mm diameter and 550 mm length), fixed in staggered arrangement with (175mm) static bed height, and (176,353,707μm sand mean particle diameter) were used . Two types of air distributors (bubble cap and perforated plate) were used with an open area of (21.6%, 6.36%, 3.97%). The study covers the air mass velocity from (0.31 to 0.57 Kg/m2 Sec), with hot bed temperature of 160Co. The results show that the overall heat transfer coefficient for the heat exchanger using bubble cap distributor is slightly higher than that for perforated plate, while the power consumption was greater by 30% for bubble cap distributor. Bubble cap distributors pressure drop was 90% greater than perforated plate distributor for the same operating conditions. At the same time , it shown that heat transfer coefficient is increased with open area increase, while opposite response was found for power consumption .

تمثل المبادلات الحرارية ذات الانابيب الحرارية المغمورة في وسط مميع أحدى الوسائل الفعالة لأسترداد الطاقة الضائعة. تناول البحث دراسة انتقال الحرارة في مبادل حراري مصنوع من عشرة أنابيب حرارية نحاسية بطول 550ملم وبقطر 22.2 ملم مغمورا في طبقة مميعة بالغاز ومرتبة بشكل متخالف . مستخدمين ثلاثة اقطار لحبيبات الرمل(176،353،707مايكروميتر) بمعدل أرتفاع للطبقة المميعة 175 ملم. تم حساب معامل انتقال الحرارة مع تغير النسبة المئوية للمساحة المفتوحة للهواء (21.6%،6.36%،3.97%) لنوعين من الموزعات الهواء (مثقب وفقاعي ) .أجريت التجارب عند درجة حرارة 160 مه للطبقة الساخنة ومعدل تدفق هواء ( 0.57 - 0.31 كغم/م2 ثا) . أظهرت النتائج أن معامل انتقال الحرارة للمبادل الذي يستخدم موزع الهواء الفقاعي كانت أكثر من موزع الهواء المثقب، فيما كان معدل استهلاك القدرة أكثر وبنسبة 30% لموزع الهواء الفقاعي . كما أن هبوط الضغط عبر الموزع الفقاعي يصل إلى 90% أكثر من موزع الهواء المثقب تحت نفسها الظروف التشغيلية . واخيراً يمكن القول أن معامل انتقال الحرارة يزداد بزيادة النسبة المئوية للمساحة المفتوحة لموزع الهواء ,بينما يقل معدل استهلاك القدرة .


Article
Thermal Performance of Film Cooling for Two Staggered Rows of Circular Jet
ألأداء الحراري لغشاء التبريد لصفين من النفاثات الدائرية المتعرجة

Authors: Assim H. Yousif --- Amer M. Al-Dabagh --- Muwafag Sh. Alwan
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 1 Part (A) Engineering Pages: 66-80
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The holes orientation and jet inclination angles are important parameters that control the development of the flow structures and the penetration and spreading of the jets. Experimental investigations that describe the film cooling performance for a two rows of staggered holes with opposite orientation angles are presented to determine the heat transfer coefficient and film effectiveness under different holes attitude. Experimentalin vestigations were done on a flat plate by using a single test transient IR thermograph technique. The attitude of the downstream row holes is fixed at inclination angle (θ=30°) and orientation angle of (Ɣ=0°), while the upstream row holes is fixed with opposite orientation angle (Ɣ=180°) and the inclination angles are changed three times as (θ=20°, 30°, and40°). Three different blowing ratios (BR) =0.5, 1.0, and 1.5 are used in experimental program at each case. Enhancements were observed, in which as theblowing ratio increased and the inclination angle of upstream row decreased, the film cooling effectiveness and heat transfer coefficient are increased.

أن زوايا الأتجاه والميل لثقوب النفث من المعالم المهمة المؤثره على بنية وتداخل وأنتشار النفاثات. لحساب معامل أنتقال الحراره وفعالية غشاء التبريد, تم أجراء تجارب عمليه لصفين من الفتحات المتعرجه الترتيب لزوايا أتجاه وميل مختلفه ولنسب نفخ متنوعه. وقد تم أجراء التجارب بأستخدام تقنية الصوره الحراريه دون الحمراءIR)) على صفيحه مستويه بألية الفحص الأنتقالي الواحد.حيث تم تثبيت زاوية الميل بمقدار 30º وزاوية الأتجاه بمقدار 0º بالنسبه للصف النازل(downstream) , بينما تم تثبيت زاوية الأتجاه للثقوب في صف الصاعد(upstream) بمقدار 180º وتغيير زاوية الميلان ثلاث مرات هي:40º, 30º, 20º ,ولكل حاله من الحالات تم أستخدام ثلاث قيملنسب النفخ وهي (BR=0.5, 1.0, 1.5).. أظهرت النتائج أن تقليل زاوية الميل للثقوب في الصف الصاعد وزيادة نسب النفخ أدت الى زيادة فعالية غشاء التبريد ومعامل أنتقال الحراره.

Keywords


Article
Heat Transfer and Flow Performance of Impingement and Impingement/Effusion Cooling Systems
اداء انتقال الحرارة والجريان لأنظمة التبريد التصادمية والتصادمية/التغلغلية

Authors: Assim H. Yousif --- Amer M. Al Dabagh --- Salah H. Abid Aun
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 6 Part (A) Engineering Pages: 1518-1536
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The current experimental study is made to investigate the heat transfer characteristics and pressure losses for both impingement and impingement/effusion cooling systems.The experiments are carried out on a metal test plate.The numerical work is made to analyze the flow behavior in the test section. The benefit of introducing the present experimental method is the capability of investigating and analyzing the performance of both impingement and impingement/effusion cooling systems by the same test rig. The impinging jet device configurations are designed as inline round multi-hole arrays with jet to jet spacing of 4 jet hole diameter. The effusion holes configurations are inline round multi-hole arrays. Staggered arrangement between jet and effusion holes is maintained. The Jet Reynolds numbers (Re_j) of 5000 to 15000 and jet height to diameter ratio ( H⁄D ) of 1.5, 2.0, and 3.0 are maintained. For impingement/effusion case, the best wall cooling effectiveness is obtained at(H⁄D =2), and maximum increment in the wall cooling effectiveness over that of impingement case is 23% at (Re_j= 5000), 16 % at (Re_j= 7500), and 14% at (Re_j= 15000). Jet spacing in impingement case and blowing ratio in impingement/effusion case show an evident effect on the discharge coefficients.

الدراسة الاختبارية الحاليةتبحثعن تحديد الخصائص الحرارية وخسائر الضغط لمنظومتي التبريد التصادمية والتصادمية/التغلغلية. الجانب النظري يشمل دراسة سلوك الجريان عند مقطع الاختبار. تم اجراء التجارب على صفيحة اختبار معدنية.ان الفائدة من تقديم المنهج العملي الحالي هو القدرة على اختبار وتحليل اداء منظومتي التبريد التصادمية والتصادمية/التغلغلية في منصة اختبار واحدة. تم ترتيب كل من ثقوب النفث وثقوب التغلغل خطيا مع اخذ المسافة بين مركزي فتحتي نفثبن متجاورتين مساوية الى اربعة أضعاف قطر الفتحة وتم الحفاظ على ترتيب متعرج عند تداخل ثقوب النفث والتغلغل في مقطع الفحص. اجريت الاختبارات عند أرقام رينولدز النفاث التي تتراوح بين 5000 الى 15000 وبنسبة مسافة فتحة النفث عن الهدف الى قطرالفتحة (H/D) هو 1.5, 2, 3. لحالة النظام التصادمي/التغلغلي, تم الحصول على افضل فعالية لتبريد الجدار عند (H/D=2) وان نسبة التحسن في فعالية التبريد بالمقارنة مع النظام التصادمي هي 23% عند (Re_j= 5000) ,16% عند (Re_j= 7500)و 14%عند (Re_j= 15000). كما اظهرت المسافة بين فتحة النفث و سطح الهدف في النظام التصادمي ونسبة النفخ للنظام التصادمي/التغلغلي تأثيرات واضحة على معاملات ضياعات التصريف.


Article
Experimental Study of Heat Transfer Parameters of Impingement Heating System Represented by Conductive Target Plate of Resistive film

Authors: Assim H. Yousif --- Amer M. Al Dabagh --- Salah H. Abid Aun
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 8 Part (A) Engineering Pages: 1588-1604
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The current experimental study focuses on the heat transfer characteristics and pressure losses for impingement systemwhich is used in cooling the liner of gas turbine combustor. Recent experiment method of conductive heat transfer technique with resistive film in the back side target plate is introduced. The present experimental model measured both the heat transfer coefficient for inner target surface and the wall cooling effectiveness for outer target surface. To physically explain the phenomena associated with interaction flow area, a computational fluid dynamic code (Fluent 14) is employed. The continuity, momentum and energy equations arecomputationally solved to analyze the flow field in the jet impingement area. The tests models of the impingement plate are made from round jet holes of inline and staggered arrays arrangement with jet to jet spacing of four-hole diameter. Jet Reynolds numbers of 4200 to 15000 and jet height to diameter ratio of 1.5, 2.0, and 3.0 are maintained. The inline array, as expected enhanced the wall cooling effectiveness over that of the staggered array by10.3%andboth jet spacing and Reynolds number have an evident effect on the discharge coefficient. Empirical correlations are obtained for both arrays arrangement to predict the area-averaged Nusselt number as a function of jet governing parameters.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (4)


Year
From To Submit

2016 (1)

2015 (1)

2013 (1)

2006 (1)