The Heat Transferred Reduction From Building Roof Which Exposed to Environmental by using Grasses and Water (Experimental Study)
تقليل كمية الحرارة المنتقلة من سقف المبنى المعرض للبيئة باستخدام تقنية المسطحات الخضراء أو المائية (دراسة تجريبية)

Author: Atif Ali Hasan عاطف علي حسن
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 6 Pages: 311-324
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The object of this paper, is to study the thermal behavior of building roofs which covered by grass (used 50 mm sand as a base for American grasses and watered weeds by 0.0004 L/sec.m2 for growth) or sprinkle the water (0.0004 L/sec.m2) on that roofs, therefore , a room of dimensions (4.5 x 4.5 x 3) m was build in 3rd floor in building at Baghdad city (33.2°N) with thermal insulation of 200 mm thickness for other room sides and using Air – conditioner 1.0 ton of refrigeration to afford the standard thermal comfort, and measured the roof surfaces temperature from 5:00 Am to 10:30 Pm (18 hr/Day) during May to September month, it was found that, the grasses in roofs building was saved 53% from electrical energy for cooling purpose, while sprinkle the water on roofs saved 38 % only

يهدف البحث الى دراسة السلوك (الأداء) الحراري للمبنى المشيد مسبقاً بعد تغطية سقفه المعرض للظروف الخارجية بالمسطحات الخضراء (استخدام تراب بسمك 50 ملم لزراعة الثيل الامريكي مع الرش بالماء بمعدل 0.0004 لتر/ثانية/م2). لذلك تم تشييد غرفة أبعادها (3 x 4.5 x 4.5) م ، تقع في الطابق الثالث لمبنى في مدينة بغداد (خط عرض 33.2 درجة شمالاً) مع استخدام عازل حراري نوع الستايربور سمك 200 ملم لتغطية الجدران والأرضية من الداخل لتقليل التسرب الحراري وتم تزويد الغرفة بمكيفة هواء سعة 1 طن تبريد لتوفير الظروف الحرارية القياسية، وتم قياس درجات الحرارة للسطح الخارجي والداخلي لسقف المبنى ودرجة حرارة الظل من الساعة 5:00 صباحاً الى 10:30 مساءاً (18 ساعة/يوم) وخلال أشهر الصيف (الشهر الخامس (ايار) ولغاية الشهر التاسع (أيلول))/ 2009 .تبين من خلال البحث أن استخدام المسطحات الخضراء ستوفر طاقة كهربائية تعادل 53% مما يستهلكه السقف الاعتيادي (بدون تغطية) بينما استخدام المسطحات المائية سيوفر 38.0 % مما يستهلكه السقف الاعتيادي وخلال فترة الصيف


Article
Available Ways For Energy Conservation in Iraqi Residence Sector.
الفرص الترشيدية المتاحة للطاقة المستهلكة في قطاع الأبنية السكنية في العراق

Author: Atif Ali Hasan عاطف علي حسن
Journal: Al-Rafidain University College For Sciences مجلة كلية الرافدين الجامعة للعلوم ISSN: 16816870 Year: 2012 Issue: 29 Pages: 32-50
Publisher: Rafidain University College كلية الرافدين الجامعة

Loading...
Loading...
Abstract

The object of this work is to determine available ways for energy conservation which it consumed in Iraqi residence sector .The study is took place in Baghdad city by selected one of residence building and deviation the all of requisite idea applicable that gives conservation, to three region as:-A: Building construction .B: Change the energy sources .C: Increase the Efficiency Value . (Decreases the losses )The result’s of this work can be reduced the consumed energy in that residence building from 71500 kw.hr to 26167 kw.hr and as conservation percentage is 63.4% from actual consumption and the quantity of fuel which enters to power station is reduced by 151.2 birrel of crow oil/ yearly/ family , the investment money is 9000000 ID which it required .

يهدف البحث الى دراسة إمكانية تحقيق ترشيد الطاقة المستهلكة في الأبنية السكنية في مدينة بغداد. لذلك تم اختيار إحدى الأبنية السكنية في مدينة بغداد لتطبيق الأفكار المقترحة لتحقيق الترشيد المنشود والتي يمكن تقسيمها الى ثلاث محاور.أ-وسائل ترتبط ببناء الوحدة السكنية .ب- وسائل ترتبط بتغيير طبيعة الطاقة المطلوبة لتشغيل الأجهزة العاملة ضمن الوحدة السكنية .ج- وسائل ترتبط برفع كفاءة و استخدام الأجهزة العاملة داخل الوحدة السكنية وجد الباحث ان تطبيق الأفكار أعلاه في الوحدة السكنية المختارة قد حققت تخفيض لكمية الطاقة الكهربائية المستهلكة حيث تقلص الاستهلاك السنوي للعائلة الواحدة من 71500 kw.hr الى 26167 kw.hr وكانت نسبة ترشيد الطاقة 63.4% و بهذا سنحقق وفر في الوقود المستخدم لتوليد الطاقة الكهربائية بمقدار 151.2برميل نفط خام سنوياً ولكل عائلة واحدة مع توفير مبلغ استثماري قدره 9000000 دينار عراقي ، علما بان فترة استرداد رأس المال المستثمر كانت خمس سنوات و بسعر فائدة نصف السنوي للودائع الثابتة قدره 11%


Article
Thermal Behavior of Present and Future Iraqi Constructed Walls (An Experimental Study)
السلوك الحراري للجدران المحلية المنفذة حالياً وتلك المقترحة (دراسـة تجريبيـة)

Author: Atif Ali Hasan عاطف علي حسن
Journal: Anbar Journal of Engineering Sciences مجلة الأنبار للعلوم الهندسية ISSN: 19979428 Year: 2012 Volume: 5 Issue: 1 Pages: 140-164
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

The object of this paper was determined the thermal behavior of present and future constructs Iraqi walls at Baghdad climate region (Latitude 33.2 °N) with or without (40) mm insulating materials. The study was carried out at day (21) July for East Orientation.The obtained results were tabulated in terms of over all heat transfer coefficient, weight of the wall per unit area, wall thickness, temperature difference between outside and inside wall face and the temperature difference between inside of the room and it's inside wall surface through on. day hours and it's average values.

يهدف البحث الى دراسة السلوك الحراري للجدران (المنفذة حالياً وتلك المقترحة للتنفيذ) ضمن الظروف المناخية لمدينة بغداد (خط عرض 33.2 درجة شمالاً) بوجود وعدم وجود عازل حراري سمكه (40) ملم، وأجريت الدراسة خلال ساعات يوم واحد (اليوم 21) من شهر تموز ولجدار مواجه للشرق.تمكن الباحث من جدولة النتائج المستخلصة من البحث والتي تضمنت المعامل الكلي لانتقال الحرارة، وزن الجدار لكل وحدة مساحة، السمك، فروق درجات الحرارة عى طرفي مادتي إنهاء الجدار (المواجه للبيئة والمواجه للغرفة) وكذلك فرق درجات الحرارة بين مادة الانهاء الداخلية (للجدار) ودرجة حرارة الهواء (الغرفة) التصميمية وبتغير ساعات اليوم الواحد وكذلك المتوسط اليومي لها.


Article
TEMPERATURE DISTRIBUTION INSIDE GROUND IN BAGHDAD CITY (EXPERIMENTAL STUDY)
توزیع درجات الح ا ررة خلال التربة في مدینة بغداد (د ا رسة تجریبیة)

Author: Atif Ali Hasan عاطف علي حسن
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2012 Volume: 5 Issue: 2 Pages: 30-42
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The purpose of this paper is measured the temperature distribution insidemud-sand mix ground whose partly shaded through summer season (April – September) atBaghdad city (Latitude 33.2 N) at 1.6 m depth , and found that the average value at thatdepth and period is 24.11 °C.

یهدف البحث الى قیاس توزیع درجات حرارة داخل تربة المناطق المزیجیة (رملیة-طینیة) ذات التظلیل الجزئي خلالفترة الصیف (نیسان لغایة أیلول) لعمق یصل الى 1.6 م في مدینة بغداد (خط عرض 33.2 درجة شمالاً) فوجد أنمتوسط درجة الحرارة خلال هذا العمق والفترة الزمنیة هي 24.11 °م


Article
Covering Building Faced Effection & Energy Conservation (Experimental Study)
اقتراح نظام مبسط لتغليف واجهــات الأبنيــة وتأثيره على ترشيـد استهلاك الطاقـــة (دراســة تجريبيـــــة)

Author: Atif Ali Hasan عاطف علي حسن
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2013 Volume: 6 Issue: 3 Pages: 22-36
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The objective of this work is reduction the electrical energy consumption for cooling building by environmental effect reduction in summer seasons, by re-covering building faced principle, therefore was selected low weight, low cost and easy assembly materials (Hollow plastic decoration or Formica layer with fiber wood) which used with or without insulating materials.The study occurs at Baghdad city (latitude 33.2°N).The researcher found that, the using plastic finishing decorative with insulating materials saved 35% from annual electrical energy, but that saved become 41% when using fiber wood with Formica layer, but become 52% when used insulated reflective surfaces.

يهدف البحث الى تقليل كمية الطاقة الكهربائية المصروفة لأغراض تكييف المبنى نتيجة تقليل تأثير البيئة على المبنى صيفاً وذلك بإعادة تغليف جدار الواجهة بأسلوب مبسط يمتاز بخفة الوزن، انخفاض الكلفة الأولية وسهولة التجميع مع المبنى المشيد مسبقاً، لذلك تم استخدام ألواح بلاستك الديكور وألواح الفورمايكا المدعمة بخشب الفايبر ورتبت بإطار من الألمنيوم لسهولة التداول والتركيب وبوجود فجوة هوائية أو عازل حراري.تمت الدراسة ضمن الظروف المناخية لمنطقة بغداد (خط عرض 33.2 درجة شمالاً). تم التوصل الى أن استخدام ألواح البلاستك الديكور مع العازل الحراري سيوفر طاقة سنوية تعادل 35% بينما استخدام التغليف بألواح الفورمايكا المدعم بخشب الفايبر سيزيد من قيمة التوفير الى 41% بينما وجود سطح عاكس للعازل الحراري سيزيد التوفير الى 52%.


Article
Simple roofing system suitable for buildings in hot climate and it's effect on energy conservation (Experimental study)
نظام مبسط لتسطيح سقوف الأبنية ملائم للمناخ الحار وتأثيره على ترشيد استهلاك الطاقة (دراسـة عمليـة)

Author: Atif Ali Hasan عاطف علي حسن
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2016 Volume: 10 Issue: 1 Pages: 1-13
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

The objective of this paper is reduced the electrical energy which used in air-condition system by replaced the common roofing system by the another which more suitable for hot climate area.The researcher was build (1x1x3)m sample room at 3rd floor in building at Baghdad city (33.2 °N) for 200mm polystiran thermal insulation for other room surfaces and air-conditioner of 0.5 Ton of refrigeration capacity is used to maintain the standard thermal comfort, the roof thermal behavior study for 15 hr/day, at day 21 from five each months (Jan, March, June, July & September). It was found the suggested roofing system reduced the dead load by 300kg/m2 and the electrical energy which used in air-conditioning system reduced by 37% when used open air gap was used, and become 30% when has used closed air gap has used and became 27% relation to ordinary system.

يهدف البحث الى تقليل الطاقة الكهربائية المستهلكة لأغراض التكييف عن طريق استبدال نظام تسطيح الأبنية شبه التقليدي (قطع خرسانية رصاصية اللون والمعروفة محلياً بالشتايكر) بنظام آخر ملائم للمناطق ذات المناخ الحار . تم تشييد غرفة أبعادها (3x1x1) م ، تقع على سطح الطابق الثالث من مبنى في مدينة بغداد (خط عرض 33.2 درجة شمالاً) مع تغليف الأسطح الداخلية للغرفة (باستثناء السقف) بألواح الستايربور العازلة حرارياً (البولي ستايرين) سمك (200) ملم لغرض تجديد تلك الأسطح، وتم توفير المستوى القياسي للراحة الحرارية باستخدام مكيفة هواء جدارية سعة (0.5) طن تبريد. تم دراسة السلوك الحراري الساعي لكل من التسطيح التقليدي والمقترح خلال 15 ساعة/يوم، ولليوم الـ (21) من الأشهر (كانون الثاني – آذار – حزيران- تموز – أيلول)/2011-2012. تم التوصل الى ان استبدال نظام التسطيح يقلل من الأحمال الإنشائية الساكنة بمقدار 300 كغم/م2 ويوفر %37 من الطاقة الكهربائية المصروفة لأغراض التكييف عند وجود فجوة هوائية مفتوحة ويصل التوفير الى %30 عندما تكون الفجوة الهوائية مغلقة وعند رفع الفجوة ينخفض التوفير الى %27 .


Article
SPECIAL GYPSUM BOARD FOR USED AS INTERIOR WALL FINISH MATERIALS AT BAGHDAD CITY
اقتراح استخدام الالواح الجبسية غير التقليدية لإنهاء السطوح الداخلية للأبنية في مدينة بغداد

Author: Atif Ali Hasan عاطف علي حسن
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2016 Volume: 9 Issue: 2 Pages: 24-37
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The gypsum which use as a direct way for finishing wall surfaces have many defect, therefore a special gypsum board has been suggested. The thermal and constructional behavior of that board was investigated at Baghdad climate zone (33.2N°) during one year (2013) at 21th day of each month for 15 hour per day. The test results showed that, the suggested gypsum board which consist of rough dust saw or feathery palm trees gives energy saving about 36% yearly

لكون ان استخدام الجص كأسلوب مباشر لأكساء وتغليف الجدران له عدة عيوب , تم اقتراح استخدام الالواح الجبسية غير التقليدية , والسلوك الحراري والانشائي لتلك الالواح تم قياسها ضمن مناخ منطقة مدينة بغداد وخلال عام واحد (2013) لليوم الـ (21) من كل شهر وخلال 15 ساعة/ يوم .تم التوصل الى أن استخدام الالواح الجبسية المقترحة التي تحوي طبقة نشارة خشبية خشنة أو سعف نخيل تحقق توفير في الطاقة قدره36 % سنوياً مقارنة بأكساء الجدار بالجص .


Article
The Economic Feasibility of Using Solar Energy in Serving Housing Complexes in Rural Areas
الجدوى الاقتصادية من استخدام الطاقة الشمسية في التجمعات السكانية للمناطق النائية

Author: Atif Ali Hasan عاطف علي حسن
Journal: Al-Rafidain University College For Sciences مجلة كلية الرافدين الجامعة للعلوم ISSN: 16816870 Year: 2017 Issue: 40 Pages: 29-45
Publisher: Rafidain University College كلية الرافدين الجامعة

Loading...
Loading...
Abstract

In order to overcome the problems associated with the electrical power provision to the remote areas ( which is distributed mainly a long the western and the south western region in Iraq), as well as the problems associated with the petroleum fuel delivery which required for electrical generator a parathion, the population lives in these area should think really about using a new sources of energy for electrical production like solar and wind . As the solar energy is available at high rates during the daylight hours nearly all over Iraq unlike the wind energy which its availability differs from region to region, the solar energy is selected as main source of energy for this study.A typical civilian compound building consist of (50) similar houses were designed to be located in rural region. This building consist, in addition to the houses, of many service building such as (adminstration, meeting hall, mosque, water well, clinic center, six grades school and a shelter for the school and clinic staff ).The electrical power and the fuel consumption required for each of the individual building were calculated. Moreover the solar collector area were estimated taking into consideration the ability for storing energy for at least ( 7 ) hours.The results for this study shows that the required capital investment was about $60000 with a payback period less than (5) years knowing the cell ages as more than ( 20 ) years .

بسبب صعوبة إيصال الطاقة الكهربائية للتجمعات البشرية في المناطق النائية (المنتشرة في عموم العراق) والتي تتركز في المناطق الغربية والجنوبية الغربية بصورة خاصة وكذلك صعوبة توصيل المشتقات النفطية اليها لتشغيل مولدات الطاقة لتوفير ما تحتاج اليه الأبنية الخدمية بصورة خاصة والمواطن الذي يسكن تلك المناطق بصورة عامة، لذلك يتطلب أن تعتمد هذه التجمعات السكانية على توفير الطاقة المطلوبة مما يتوفر لديها من مصادر طبيعية و أهم تلك المصادر هي الطاقة الشمسية وطاقة الرياح، ولتوفر الطاقة الشمسية بمستويات عالية جداً خلال ساعات النهار الطويلة نسبياً وعلى مدار أيام العام تقريباً في عموم العراق على عكس طاقة الرياح التي تتوفر في مناطق دون غيرها، لذلك تم الاعتماد عليها باعتبارها المصدر الرئيسي للطاقة في تلك المواقع. تم تصميم مجمع مدني خدمي لقرية نموذجية مؤلفة من خمسين عائلة (دار) تقع في منطقة نائية وتحديد الأبنية الخدمية المطلوبة (مبنى اداري للقرية – قاعة اجتماع – مصلى – بئر ماء – مركز صحي – مدرسة (6) صفوف – مأوى صغير لسكن الكادر التعليمي والصحي ومركز تجاري بسيط) وتم حساب كمية الطاقة الكهربائية المطلوبة لكل مرفق وكمية الوقود المطلوبة مع حساب سعة مولدات الطاقة التقليدية وكذلك مقدار مساحة الألواح الشمسية الفولتائية المطلوبة مع الأخذ بالاعتبار امكانية خزن الطاقة لاستخدامها بعد مغيب الشمس لمدة (7) ساعات، واتضح من خلال دراسة الجدوى الاقتصادية، ان رأس المال المطلوب للاستثمار في حدود60000 $ وكانت فترة استرجاع المبلغ المستثمر أقل من خمس سنوات علماً بأن عمر الخلايا اعلى من (20) سنة


Article
Thermal Properties of New Insulated Non Bearing Walls Systems for Hot Climate Area
السلوك الحراري لعدة أنظمة جدران غير حاملة مناسبة للاستخدام في مناطق المناخ الحار

Author: Atif Ali Hasan عاطف علي حسن
Journal: Al-Rafidain University College For Sciences مجلة كلية الرافدين الجامعة للعلوم ISSN: 16816870 Year: 2017 Issue: 41 Pages: 86-107
Publisher: Rafidain University College كلية الرافدين الجامعة

Loading...
Loading...
Abstract

In order to reduce the using of brick as a primary material for nonbearing walls construction, many light weight system having a low heat transfer coefficient (consist by 100 mm thickness from limestone takers ) has been suggestedThese suggested samples of walls have been chosen according to the weather condition of Baghdad city (L= 33.2N0 ) at the day of (21) of each month (during the year of 2012), comparing their thermal performance with that of traditional classical walls which consist mainly from a 240 mm thickness brick. The results of study shows that using the combined system (consist of three layers from compressed wood, thermal insulation located between each layer, and an air gap of 50 mm thickness) will provide a saving in energy of 42%, 39%, and 41% for summer season, winter season and annual, respectively. Moreover the results shown that using the gypsum board instead of the compressed wood, the saving in energy will be reduced to 27%, and 6% at summer and winter season respectively. Using the rough ceramic layer for outside covering of the walls, will save energy about 35% and 6% at summer and winter season respectively with an annual saving about 22%. While using the smooth ceramic layer for covering the walls will save energy 17% , 9% and 31% at summer season , winter season and annual saving respectively .The weight of the suggested wall is reduced by range of (7% –13% ) as compared with the traditional wall ,in addition to the cost of construction was noticed to be less by 27% as compared with the cost of the traditional wall

المستخلصلتقليل الاعتماد على الطابوق كمادة أساسية في تشييد جدران غير حاملة في الأبنية الهيكلية، تم اقتراح عدة أنظمة خفيفة الوزن وذات معامل انتقال حراري منخفض مع استخدام الحجر الكلسي سمك (100) ملم لأغراض التقوية والجمالية، تم اختيار هذه النماذج ضمن الظروف المناخية لمدينة بغداد ]خط عرض 33.2 درجة شمالاً[ ولليوم الـ (21) من كل شهر (على مدار العام 2012) ومقارنة السلوك الحراري لها مع الجدار التقليدي المشيد من الطابوق سمك 240ملم.اتضح من خلال الدراسة ان استخدام النظام المصنع من ثلاث طبقات من الخشب المضغوط مثبت بينها عازل حراري سمك 50 ملم وفجوة هوائية سمك 50 ملم يوفر طاقة كهربائية حوالي %42 مما يستهلكه الجدار التقليدي صيفاً وخلال الشتاء يوفر %39 بينما يكون التوفير السنوي %41 وعند استخدام الألواح الجبسية بديلاً عن طبقة الخشب المضغوط الداخلية ينخفض التوفير الى %27 صيفاً، %6 شتاءاً وعلى مدار العام كان التخفيض %17 . أما التغليف من الخارج بالسيراميك ذو السطح الأملس أو الخشن، اتضح بأن استخدام السيراميك ذو السطح الخشن يوفر طاقة في حدود %35 صيفاً، %6 شتاءاً وعلى مدار العام يكون التوفير %22 . بينما استخدام السيراميك ذو السطح الأملس فيحقق توفير %17 صيفاً، %9 شتاءاً وعلى مدار العام يكون في حدود %13 ونسبة تقليل وزن الجدار المقترح تكون في حدود%(7-13) من وزن الجدار التقليدي وكذلك كلفة التشييد قد انخفضت بمقدار %27 من تكلفة إنشاء الجدار التقليدي.


Article
Thermal Behavior for Double Shell Thermostone Wall
السلوك الحراري لجدار من الثرمستون ثنائي القشرة نظرياً وعملياً

Author: Atif Ali Hasan عاطف علي حسن
Journal: Al-Rafidain University College For Sciences مجلة كلية الرافدين الجامعة للعلوم ISSN: 16816870 Year: 2018 Issue: 43 Pages: 106-125
Publisher: Rafidain University College كلية الرافدين الجامعة

Loading...
Loading...
Abstract

The thermal behavior of thermostone wall which used double shell system, will be compared theoretically and practically, by changing the material type which filled a space between wall parts (mud brick, fiber wood or asbestos sheet with air gap, sawdust, insulating materials, air gap, and thermostone).The researcher build a (1 x 1 x 2)m room sample at third story in building ((Baghdad city – Latitude 33.2° North)) and (1 x 2)m testing wall to east orientation, while the other surfaces were insulated by (200) mm styropor sheets and using Air – Conditioner (0.5) ton of refrigeration to provide the standard thermal comfort in that room. The wall and air Temperature, cooling load and electrical energy consumption for (15 hr/day) along summer season (May to September), and compared with the results from ASHRAE Guide .The researcher found, the value of results from theoretical calculation is more than the practically measured by (10 – 45) % .

يهدف البحث الى مقارنة الأداء الحراري للجدار المشيد من مادة الثرمستون باستخدام تقنيات الجدران ثنائية القشرة نظرياً وعملياً. لذلك تم تشييد نموذج لغرفة (في مدينة بغداد) أبعادها (2 × 1 × 1) م، الجدار (2 × 1) م، ذو التوجيه الشرقي قيد الدراسة، بينما الجدران الأخرى والأرضية والسقف تم عزلها باستخدام ألواح الستايربور ذي السمك (200) ملم، مع استخدام مكيفة هواء جدارية سعتها التبريدية 0.5 طن تبريد لتوفير الظروف الحرارية القياسية داخل الغرفة. تم تغيير مادة الحشوة لجدار الثرمستون ثنائي القشرة باستخدام عدة مواد متوفرة محلياً وغير شائعة الاستخدام في التشييد حالياً، (الطابوق الطيني – اللبن، الألواح القصبية، خشب فايبر مع فجوة هوائية، الواح الاسبست مع فجوة هوائية، نشارة خشب، عازل حراري، فجوة هوائية، الثرمستون). وتم قياس درجات الحرارة لطبقة الانهاء الخارجية والداخلية للجدار قيد الدراسة وكذلك درجة حرارة هواء البيئة (الظل) من الساعة 5:00 صباحاً ولغاية 7:30 مساءاً (15ساعة / يوم) وخلال أشهر الصيف (الشهر الخامس (أيار) ولغاية الشهر التاسع (أيلول) ورسم السلوك الحراري خلال تلك الفترة للجدار.تمت المقارنة بين ما تم التوصل إليه عملياً من أحمال تبريدية وكمية الطاقة الكهربائية المستهلكة لأغراض التكييف ولكل جدار مع ما تم حسابه من خلال البيانات المتوفرة في نشرات الجمعية الامريكية لمهندسي التكييف .توصل الباحث الى وجود فرق كبير وغير مقنع بين نتائج الحسابات النظرية والعملية وكان الاختلاف يتراوح ما بين (10 – 45) % باختلاف مادة التحشية .

Listing 1 - 10 of 12 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (12)


Language

Arabic (10)

Arabic and English (2)


Year
From To Submit

2018 (1)

2017 (4)

2016 (2)

2013 (1)

2012 (3)

More...