research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
COMPARATIVE ANALYSIS BETWEEN MODERN AND CONVENTIONAL HVAC SYSTEMS FOR USE AT COMMERCIAL BUILDING IN BAGHDAD CITY / IRAQ
تحميل مقارن لمنظومات التبريد والتكييف الحديثة والتقليدية لبناية تجارية في مدينه بغداد / العراق

Authors: Dr. Nabil J. Yasin د.نبيل جميل ياسين --- Badran M. Salim بدران محمد سالم
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2017 Volume: 30 Issue: 6 Pages: E47-E63
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

This research use the life cycle cost analysis and a detailed cooling, heating and electrical load profiles to determine the initial, running and maintenance costs for evaluation the economic feasibilities of using three different types of central air conditioning systems in a commercial building located in Baghdad city / Iraq, so as to select the best air conditioning system. The systems were modern air conditioning system (variable refrigerant flow), all air conditioning system (package roof top unit) and all water air conditioning system (fan coil unit). The present-worth cost method for lifecycle cost period for fifteen years analysis is applied. The transfer function method was used with hourly analysis program (HAP v4.9) for estimation the cooling and heating loads in each space of the building with adopted the indoor air quality in the design as adequate fresh air per person, acceptable noise level and air quality. The comparison between the different methods for the total cost (during fifteen years) for air conditioning systems showed that the variable refrigerant flow system has lowest total cost compare with other methods used for the period operation, so as the variable refrigerant flow air conditioning system worked into variable cooling and heating load between 0% and 100% of total load.

يتضمن البحث الحالي اجراء تحميل لكمفة العمر الافتراضي وحسابات احمال التبريد والتدفئه بالاضافه الى الأحمال الكهربائية لتحديد الكلفه الاوليه وكلفه الصيانه وكلفة التشغيل لثلاث أنواع مختلفة من منظومات التكييف المركزيه التي تعمل في نموذج لبنايه تجاريه )مول( تقع في مدينه بغداد/العراق. المنظومات كانت عمى النحو التالي منظومة تبريد وتكييف هواء مركزية نوع هواء كمي ومنظومة تبريد وتكييف هواء مركزية نوع ماء كمي ومنظومة تبريد وتكييف هواء مركزية حديثة. تم اعتماد طريقة دالات التحويل مع برنامج ) HAP ( نسخة 4.9 لأيجاد احمال التبريد والتدفئة الخاصة بكل حيز من المول مع الاخذ بنظر الاعتبار توفير شروط جودة الهواء الداخلي ) IAQ ( التي تخص توفير هواء نقي لكل شخص ويكون الهواء المجهز ذو نقاوة جيدة بالاضافة الى توزيع الهواء بدون ضوضاء تؤثر عمى راحة الانسان في داخل الحيز المشغول ، من خلال مقارنة الكلفة الكمية لمنظومات التبريد والتكييف المركزية وخلال مدة تشغيلية قدرها خمسة عشر عام تبين ان الاختيار الامثل والمناسب لهذا المشروع هو منظومة تبريد وتكييف هواء مركزية حديثة ) VRF (لانها تعمل حفظ لمطاقة وبالتالي تكون صرفيات الطاقة أقل من المنظومات الاخرى فضلا عن عمل المنظومة بحمل جزئي للتبريد او التدفئة متغيير يترواح بين % 0 الى 100 % ..


Article
THEORATICAL ANALYSIS OF FLAT PLATE SOLAR COLLECTOR PLACED IN MOSUL CITY BY USING DIFFERENT ABSORBING MATERIALS AND FLUIDS
دراسة نظرية لمجمعات شمسية ذات صفائح مستوية موضوعة في مدينة الموصل باستخدام معادن وموائع مختلفة

Authors: Hasson S. Hamood حسون شعبان حمود --- Badran M. Salim بدران محمد سالم --- Nabeel M. Abdulrazzaq نبيل مخلف عبدالرزاق
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2015 Volume: 6 Issue: 2 Pages: 1-12
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

In this paper, a mathematical model and simulation of flat plate solar collector are developed. The weather data, which used in the calculations of the performance of the collector, is for Mosul city. Detailed energy analyses were carried out for evaluating the efficiency and useful heat gain of a typical flat plate solar collector under certain operation and design conditions. In this analysis, different fluids and different absorbing materials were used to indicate there affect on the performance of flat plate solar collector. Operating parameters, which considered as variables, are the mass flow rate, the inlet and the outlet temperature difference and the total solar radiation flux. The simulation program had written by using EES (Engineering Equation Solver) software program. The results of this analysis show that the copper and aluminum give a good efficiency up to 0.6 with value (ΔT/GT = 0.03) with water as a working fluid, while the plain carbon steel gives less than the number that stated previously. The results show also that the copper and the aluminum give the largest useful heat gain extracted from the collector as compared with plain carbon steel. It has been also show that the solar collector efficiency is higher in case of using water as working fluid than that of propylene glycol solution.

يتضمن البحث الحالي إنشاء نموذج رياضي لمجمعات شمسيه ذات صفائح مستوية بغرض محاكاة النموذج الواقع تحت تأثير أجواء مدينة الموصل من درجات الحرارة العظمى والصغرى بغرض تحديد كفاءة تلك المجمعات الشمسية. حيث تم اجراء تحليل مفصل للطاقة الشمسية بغرض تقييم كفاءة هذه المجمعات الشمسية و الحرارة النافعة المكتسبة تحت ظروف تشغيلية وتصميمية معينة. تم أستخدام الماء ومحلول البروبلين كلايكول كموائع تشغيل في المنظومة قيد الدراسة بينما أستخدم النحاس و الالمنيوم و الصلب الكاربوني كمعادن للصفائح الماصة للحرارة في المجمع الشمسي. تم أختبار معدل الجريان الكتلي للمائع والتغير في درجة حرارة المائع الداخل والخارج من المجمع الشمسي بالإضافة الى التغير في مقدار فيض الاشعاع الشمسي كظروف تشغيلية للمنظومة. تم بناء برنامج حسابي لمحاكاة المجمع الشمسي وذلك باستخدام الوسط )ولقد أظهرت النتائج المستحصل عليها من خلال البرنامج أن أستخدام النحاس EESالبرمجي لحل المعادلات الهندسية ( عندما تكون قيمة 0.6 والالمنيوم كصفائح ماصة للحرارة تعطي أعلى كفاءة يصل مقدارها إلى (ΔT/GT=0.03) كما أظهرت النتائج أ ، باستخدام الماء كمائع تشغيل في المنظومة ن النحاس والالمنيوم يعطون أعلى كمية من الطاقة ًأيضا النافعة بالمقارنة مع الصلب الكاربوني بالاضافة الى أستنتاج أن استخدام الماء كمائع للتثليج اعطى كفاءة اعلى مقارنة مع البروبلين كلايكول.