research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
Hydrogenation of Nitrobenzene in Trickle Bed Reactor over Ni/Sio2 Catalyst
هدرجة النتروبنزين في مفاعل سيحي باستخدام النيكل/سيليكا كعامل مساعد

Author: Majid I. Abdulwahab ماجد ابراهيم عبد الوهاب
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 10 Pages: 1314-1326
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Trickle bed reactor was used to study the hydrogenation of nitrobenzene over Ni/SiO2 catalyst. The catalyst was prepared using the Highly Dispersed Catalyst (HDC) technique. Porous silica particles (capped cylinders, 6x5.5 mm) were used as catalyst support. The catalyst was characterized by TPR, BET surface area and pore volume, X-ray diffraction, and Raman Spectra. The trickle bed reactor was packed with catalyst and diluted with fine glass beads in order to decrease the external effects such as mass transfer, heat transfer and wall effect. The catalyst bed dilution was found to double the liquid holdup, which increased the catalyst wetting and hence, the gas-liquid mass transfer rate. The main product of the hydrogenation reaction of nitrobenzene was aniline. Reaction operating conditions, i.e., temperature, liquid flow rate, and initial feed concentration were investigated to find their influences on the conversion and rate of nitrobenzene hydrogenation. Under normal conditions without bed dilution, the system was mass transfer controlled. In the diluted reactor, on the other hand, the resistance of mass transfer was nearly absent and the system became under surface kinetic control. The catalyst showed significant deactivation during the reaction period due to the adsorption of intermediate amine products on the surface of the catalyst. The kinetic study revealed that the reaction is zero order with respect to nitrobenzene concentration for the range of concentration between 0.58 to 1.17 mol/L while it was of positive order for the initial concentration less than 0.58 mol/L.

تم استخدام المفاعل السيحي لدراسة عملية هدرجة النتروبنزين على العامل المساعد نيكل/سيليكا. تم تحضير العامل المساعد باستخدام تكنيك الـ HDC. تم استعمال حبيبات السيليكا المسامية (شكل اسطواني 6x5.5) كمادة حاملة للعامل المساعد. تم ايجاد خواص العامل المساعد المحضر بفحص TPR و طريقة BETللمساحه السطحية و حجوم المسامات و التحليل الطيفي بطريقة انكسار اشعة اكس و كذلك التحليل الطيفي بجهاز رامان. تم شحن المفاعل بالعامل المساعد المخفف بكرات الزجاج الدقيقة و ذلك لخفض التأثيرات الخارجية كانتقال المادة و انتقال الحرارة و تأثير الجدار. و قد وجد ان استخدام الحبيبات الدقيقة مع العامل المساعد في المفاعل قد ادى الى مضاعفة محتوى السائل في المفاعل و الذي أدى بدوره الى زيادة درجة تبلل العامل المساعد و بالتالي زيادة معدل انتقال المادة للسائل و الغاز. كان المنتج الرئيسي من تفاعل هدرجة النترو بنزين هو الانيلين. تم ايجاد تأثير كل من الحرارة و معدل جريان السائل و التكيز الابتدائي للنتروبنزين على مقدار التحول للنتروبنزين و كذلك على سرعة التفاعل. في الظروف الطبيعية و بدون استخدام التخفيف بحبيبات الزجاج كان النظام تحت تأثير انتقال المادة. من جهه اخرى كانت مقاومة انتقال المادة في المفاعل المخفف بحبيبات الزجاج غائبة تقريبا و النظام تحت سيطرة التفاعل السطحي. كما لوحظ ان العامل المساعد يفقد فعاليته خلال فترة التفاعل بسبب بسبب امدصاص المواد الناتجه على السطح. بينت الدراسة ان تفاعل هدرجة النتروبنزين من الدرجه الصفر نسبة الى تركيز النتروبنزين في مدى التراكيز من 0.58 الى 1.17 مول/لتر بينما تصبح درجة التفاعل موجبة لمدى التراكيز اقل من 0.58 مول/لتر.


Article
Corrosion Inhibition of Low Carbon Steel in Sulfuric Acid Using Polyvinyl Alcohol

Authors: Majid I. Abdulwahab --- Ayad B. Ahmed --- Aprael S. Yaro
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2016 Volume: 17 Issue: 1 Pages: 21-36
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The inhibitive power of Polyvinyl Alcohol (PVA) was investigated toward the corrosion of carbon steel in 0.2N H2SO4 solution in the temperature range of 30-60˚C and PVA concentration range of 150-2000 ppm. The corrosion rate was measured using both the weight loss and the electrochemical techniques. The weight loss results showed that PVA could serve as a corrosion inhibitor but its inhibition power was found to be low for the corrosion of carbon steel in the acidic media. Electrochemical analysis of the corrosion process of carbon steel in an electrochemical corrosion cell was investigated using 3-Electrode corrosion cell. Polarization technique was used for carbon steel corrosion in 0.2N H2SO4 solutions in presence and absence of the inhibitor investigated. Electrochemical runs were done in the PVA concentrations of 150, 1000, and 2000 ppm and temperatures of 30, 40, 50, and 60˚C. It was shown that the inhibition efficiency for PVA decreased with increasing temperature at a given PVA concentration. On the other hand it was shown that at given temperature the inhibition efficiency of PVA was increased with increasing of PVA concentration in the corrosive acid until a PVA concentration of 2000 ppm was reached. The Maximum inhibition efficiency reached was about 71 % at 30ºC and 2000 ppm concentration, calculated by the weight loss technique. It was indicated also that the corrosion of carbon steel in 0.2N H2SO4 is highly activation controlled and inhibition action is occurring at both anodic and cathodic sites on the metal surface.


Article
Experimental Study of Thermophysical Properties of TiO2 Nanofluid

Authors: Majid I. Abdulwahab --- S.M.Thahab --- Asmaa H.Dhiaa
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2016 Volume: 17 Issue: 2 Pages: 1-6
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Titanium-dioxide (TiO2) nanoparticles suspended in water, and ethanol based fluids have been prepared using one step method and characterized by scanning electron microscopy (SEM), and UV–visible spectrophotometer. The TiO2 nanoparticles were added to base fluids with different volume concentrations from 0.1% to1.5% by dispersing the synthesized nanoparticles in deionized water and ethanol solutions. The effective thermal conductivity, viscosity and pH of prepared nanofluids at different temperatures from 15 to 30 oC were carried out and investigated. It was observed that the thermal conductivity, pH, and viscosity of nanofluids increases with the increase in TiO2 nanoparticle volume fraction. The thermal conductivity of TiO2 nanofluids significantly increases linearly with increasing particle vol. fraction at different temperature values and also it was found that the viscosity increases with increasing particle vol. fraction and decreases with the increase in temperature.


Article
Study The Convective Heat Transfer of TiO2 /Water Nanofluid in Heat Exchanger System
دراسة نقل الحمل الحراري للمائع النانوي اوكسيد التيتانيوم/ ماء في نظام مبادل الحرارة

Authors: Asmaa H.Dhiaa --- Majid I. Abdulwahab --- S.M.Thahab
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 7 Part (B) Scientific Pages: 1319-1329
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The enhancements of heat transfer coefficient and Nusselt number in a heat exchanger system were achieved by using Titanium-dioxide (TiO2) nanoparticles with an average diameter of 10 nm. TiO2 nanoparticles/water has a better thermal conductivity compared to conventional working fluids (water). The heat transfer rate in a vertical shell and tube heat exchanger counter flow under laminar and turbulent flow conditions were investigated. The liquid flow rate has been varied in the range of 50-300 l/h whilethe inlet temperature was between 20 to 60ºC. The effects of factors such as the Reynolds number and the peclet number on the heat transfer and flow characteristics were carried out and investigated. It was observed that the convection heat transfer increased remarkably with the increment of the temperature under various values of the Reynolds number.As well as,the Nusselt number increased about 17% as compared to pure water;at a nanofluid velocity of 0.0192 m/s at inlet temperature of 600C.

وقد تم تحقيق تحسينات في معامل انتقال الحرارة و رقم نسلت في نظام المبادل الحراري باستخدام ثاني أكسيد التيتانيوم (TIO2) النانوية مع متوسط قطرهامن 10 نانومتر. TIO2 النانوية / الماء له الموصلية الحرارية بشكل أفضل مقارنة مع السوائل العمل التقليدية (المياه). وتتدفق في رأسي قذيفة وأنبوب مبادل حراري تدفق العداد تحت تدفق الطباقي وظروف التدفق المضطرب وتم التحقيق. وقد اختلفت معدل تدفق السائل في مجموعة من (50-300) لتر / ساعة داخل درجة حرارة مدخل من (20-60) درجة مئوية. أجريت آثار العوامل مثل عدد رينولدز وعدد peclet على نقل الحرارة وتدفق الخصائص من والتحقيق فيها. ولوحظ أن الانتقال الحراري زاد بشكل ملحوظ مع زيادة درجة الحرارة تحت قيم مختلفة من عدد رينولدز. وكذلك، ارتفع عدد نسلت حوالي 17٪ بالمقارنة مع المياه النقية؛ في حين تم زيادة معامل انتقال الحرارة حوالي 37٪ بالمقارنة مع الماء النقي الذي هو 0.0192 م / ث تحت 600C.


Article
Reuse of Spent Hydrotreating Catalyst of the Middle Petroleum Fractions
اعادة تدوير العامل المساعد المستهلك والمستخدم في هدرجة المستقطرات الوسطية

Authors: Safa Nabeel Abdulqahar --- Majid I. Abdulwahab --- Khalid K. Hummadi
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2019 Volume: 20 Issue: 1 Pages: 15-22
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Reuse of spent hydrodesulphurization (HDS) of middle petroleum fractions catalyst CoMo/γAl2O3 was accomplished via removal of coke and contaminants such as vanadium, Iron, Nickel, and sulfur. Three processes were adopted; extraction, leaching, decoking. Soluble and insoluble coke was removed. Leaching step used three different solvents (oxalic acid, ammonium peroxydisulfate and oxalic acid + H2O2) in separate in order to remove contaminant metals (V, S, Ni and Fe). The effect of soluble coke removal on leaching step was studied. It was found that the removal of soluble coke significantly enhances the leaching of contaminants and barely affected the removal of active metals (Co and Mo). It was found that the best route (sequence) was soluble coke extraction followed by contaminants leaching then decoking process and the best leaching solvent was oxalic acid. According to this determination, the removed contaminants were 79.9 % for sulfur, 13.69% for vanadium, 82.27 % for iron, and 76.34 % for nickel. The active components loss accompanied with this process were 5.08 % for cobalt and 6.88% for molybdenum. Leaching process conditions (leaching solvent concentration, temperature and leaching time) were studied to determine the best-operating conditions. The rejuvenated catalyst activity was examined by a pilot scale HDS unit of naphtha. Sulfur content removal of naphtha was found to be 85.56 % for single pass operation under typical operating conditions of refinery HDS unit of naphtha which are 1 ml/min feed flow rate, 200 H2/HC ratio, 32 bar operating pressure and 320 °C operating temperature.

اعادة استخدام العامل المساعد المستخدم في هدرجة المستقطرات الوسطية لازالة الكبيريت CoMo/ᵞAl2O3 انجزت بواسطة ازالة الكاربون والملوثات الاخرى كالفناديوم, الحديد, النيكل والكبريت. تم استخدام ثلاث عمليات في المعالجة وهي : الانتزاع , الاستخلاص, وازالة الكاربون. تمت ازالة كل من الكربون القابل للذوبان والكاربون الغير قابل للذوبان في خطوة الاستخلاص, وتم استخدام ثلاثة مذيبات بصورة منفصلة وهي حامض الاوكزالك, الامونيوم البيروكسي ثنائي السلفات, وحامض الاوكزالك + بيروكسيد الهيدروجين. تمت دراسة تاثير ازالة الكاربون الذائب ووجد ان ازالته مهمة في تعزيز عملية الانتزاع للملوثات وتاثيرها قليل بالنسبة للمعادن الفعالة للعامل المساعد ( الكوبلت والمولبدنيوم ). وجد ان افضل مسار هو ازالة الكاربون الذائب متبوعة بانتزاع الملوثات وازالة الكاربون الغير ذائب وافضل مذيب كان حامض الاوكزالك. وفقا لهذه العملية كانت نسبة ازالة الملوثات هي 79.9% للكبريت, 13.69% للفناديوم, 82.27% للحديد, و 76.34% للنيكل. كمية الفقدان في المادة الفعالة بسبب هذه العملية كانت 5.08% للكوبلت, و 6.88% للمولبدنيوم. تمت دراسة ظروف عملية الانتزاع ( تركيز المذيب المستخدم في الانتزاع, درجة الحرارة, وقت العملية ) من اجل تحديد افضل الظروف. تم اختبار فعالية العامل المساعد المنشط في وحدة نطاق تجريبي للهدرجة لازالة الكبريت للنفثا. نسبة الكبريت المزال من النفثا كانت 85.56% لعملية تمرير واحدة للنفثا تحت ظروف تشغيلية مثالية لوحدة ازالة الكبريت بالهدرجة للمصافي النفطية والمتمثلة بمعدل جريان 1 ملدقيقة, نسبة هيدروجنهيدروكاربونات =200, ضغط 32 بار, ورجة حرارة 320 درجة سليليزية.


Article
Study of the Performance of Paraffin Wax as a Phase Change Material in Packed Bed Thermal Energy Storage System

Loading...
Loading...
Abstract

The present work deals with an experimental investigation of charging and discharging processes in thermal storage system using a phase change material PCM. Paraffin wax was used as the PCM which is formed in spherical capsules and packed in a cylindrical packed column which acted as an energy storage system. Air was used as the heat transfer fluid HTF in thermal storage unit. The effect of flow rate and inlet temperature of HTF on the time of charging and discharging process were studied. The results showed that the faster storage of thermal energy can be made by high flow rate of heat transfer fluid HTF and high inlet temperature of heat transfer fluid. It was found that at 65°C HTF inlet temperature, the melting and solidification processes accelerated by 27.9% and 57.14% respectively, when the flow rate was increased from 9 to 24 L/s. Also, when the HTF inlet temperature changed from 65°C to 80°C, the time needed to complete melting process decreased by 38.8%.

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (6)


Year
From To Submit

2019 (1)

2016 (3)

2015 (1)

2013 (1)