research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Experimental and Theoretical Behavior of Reinforced Concrete One Way Slabs Strengthened by Ferrocement Cover at Tension Face

Authors: Mazan D.Abdullah --- Alyaa Ali Hassen
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 4 Pages: 1134-1150
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This paper presents a study of the flexural behavior of strengthened reinforced concrete one slabs by ferrocement cover in tension. This study included testing 14 simply supported one way slabs, which include 3 control slabs,11 strengthened slabs. In the strengthened slabs, the effect of the using ferrocement cover on the specimens of avairable depth, the thickness of ferrocement cover, number of wire mesh layers on ferrocement and the compressive strength for mortar on the ultimate load, mid span deflection at ultimate load and cracks pattern were discussed. All reinforced concrete slab specimens were designed of dimensions (1800mm*300mm) with (70-100mm) thickness and reinforced identically to fail in flexure. All slabs have been tested in simply supported conditions subjected to two point loads. The experimental results show that the ultimate loads are increased by about (4.1-15.3%) for the slabs strengthened with ferrocement with respect to the unstrengthened reinforced concrete slab (control slab). Three-dimensional nonlinear finite element analysis has been used to conduct the analytical investigation, ANSYS (Version 14.0) computer program was used in this study. The analytical result from modeling in ANSYS program exhibited a good agreement with experimental results.

يتضمن البحث الحالي دراسة مقاومة الانثناء للبلاطات المقواة والمصلحة باستخدام طبقة الفيروسمنت في منطقه الشد تضمنت الدراسة تهيئة و فحص اربع عشر بلاطة، ثلاثه كبلاطة مرجعية واحدى عشر منها مقواة بالفيروسمنت، وبلاطة واحدة تم أخذهما كبلاطات مرجعية. إن المتغيرات التي تمت دراستها في عملية التقوية هي مدى فعالية الفيروسمنت في تقوية العينات ذات الاعماق المختلفة ، عدد طبقات المشبكات السلكية و مقاومة الانضغاط للفيرو سمنت على الحمل الأقصى والأود المقابل له بالإضافة إلى تأثيرها على انماط الشقوق.صممت جميع البلاطات الخرسانية المستخدمة في هذا البحث بالابعاد (1800*300 ملم)مع سمك(70-90ملم) وتم تسليحها بشكل يضمن فشلها بالانحناء. تم فحص جميع البلاطات في فضاء بسيط الاسناد وبتسليط نقطتين حمل . أظهرت النتائج العملية التي تم الحصول عليها من النتائج المختبرية أن عملية تقوية البلاطات الخرسانية باستخدام لفيروسمنت ادت الى زيادة في قيمة التحمل الاقصى للانحناء للبلاطات (Ultimate Loads) يصل مقدارها بين (4.1-15.3%) مقارنة بالبلاطات الخرسانية غير المقواة باستخدام لفيروسمنت. تم أستعمال التحليل اللاخطي بواسطة العناصر المحددة (Finite Elements) ثلاثية الأبعاد كوسيلة عددية للدراسة والتحري عن سلوك وتصرف هذه البلاطات باستخدام البرنامج (ANSYS الاصدار الرابع عشر). النتائج النظريه من البرنامج( ANSYS) اعطت نتائج جيده مع النتائج العملي .


Article
Experimental Study of Behavior of Reinforced Concrete One-Way Slabs Strengthened and Repaired by Ferrocement at Tension Zone
التقصي العملي لمقاومة الانثناء للبلاطات الخرسانية المسلحة ذات الاتجاه الواحد المقواة والمصلحة بغطاء من الفيروسمنت في منطقه الشد

Author: mazan D.Abdullah مازن ديوان عبد الله
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2017 Volume: 11 Issue: 3 Pages: 52-67
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

The principal objective of this paper is to investigation the experimental of the flexural behavior of strengthened and repaired reinforced concrete slabs with ferrocement tension zone. The result of tests on 10 simply supported one way slabs were presented, at which include 1control slab, 5strengthened slabs and 4repaired one way slabs. In the strengthened slabs, the cover of the control slab replacing with ferrocement cover, cold joint between ferrocement layer and the slab, connection type between the ferrocement layer and the slab, on the ultimate load, first crack load, the mid span-deflection, crack width and spacing were examined. In the repaired part the slabs were loaded to (55 %) of measured ultimate load of control slab, the effect of the thickness and number of wire mesh layers on crack pattern, mid span deflection and ultimate load was examined. In the repaired part the slabs were loaded to (55 %) of measured ultimate load of control slab, effect of the number of wire mesh layers of ferrocement on the mid span deflection, ultimate load and crack pattern was examined. The experimental results of strengthened and repaired slabs indicate that; the ultimate loads and mid span deflection were more effected by using ferrocement mortar at tension zone. The increase in ultimate load (8.2-18%) for strengthen slab and (9.1-17.3%) for repaired slab respect to the control slab.

ان الغرض من هذا البحث هو تقديم دراسة عملية عن مقاومة الانثناء للبلاطات المقواة والمصلحة باستخدام طبقة الفيروسمنت عند منطقه الشد.تعرض نتائج الاختبارات على 10 بلاطات بسيطه الاسناد تتضمن واحده منها كبلاطه مرجعيه وخمس منها مقواه اربع لدراسة فاعلية عملية الإصلاح. في عملية التقوية تم دراسة تأثير استبدال الغطاء الخرساني العادي من لوح التحكم بواسطة غطاء فيروسيمنت ، نوع الربط بين بلاطه وطبقه الفيروسمنت و تواجد المفصل البارد بين البلاطه وطبقه الفيروسمنت على الحمل الأقصى ,اول حمل تشقق,عرض التشقق و الحمل الأقصى والأود المقابل له. ، أما في حالة الإصلاح فقد تم تسليط ( % 55 ) من الحمل الأقصى للبلاطات المرجعية على البلاطات المراد إصلاحها ودراسة تأثير عدد طبقات المشبكات السلكية وسمك طبقه الفروسمنت على الحمل الأقصى والأود المقابل له بالإضافة إلى تأثيرها الشقوق.نتائج البلاطات المقواه والمصلحه ان االزياده بالحمل الاقصى قد ازدادت بمقدار (8.2-18%) و(9.1-17.3%) على التوالي %) مقارنة بالبلاطات الخرسانية غير المقواة باستخدام لفيروسمنت.

Keywords

: Concrete --- ferrocement --- repair --- slab --- strengthening

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (1)

English (1)


Year
From To Submit

2017 (2)