Design and Implementing A Heat Pipe Expperimantal System For Residential Heating

Authors: Zeina A. Al-Saadi --- Mikdam M. saleh
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2007 Volume: 13 Issue: 4 Pages: 2031-2052
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The design and construction of an instrumented heat pipe H.P for domestic heating that uses water as a working fluid was undertaken to investigate experimentally the performance of the H.P under various operating conditions of: Power levels, water inventories and angle of inclinations. A theoretical model to predict the temperature of the condenser surface (the temperature at which heat is rejected) and system pressure at steady state conditions was developed and used to compare these parameters with the experimental findings. The model utilizes the total heat supplied to the evaporator to predict system pressure and condenser temperature. The theoretical model is suitable for vertical H.P (i.e. θ =0º) and its predictions of condenser surface temperature is within ±16% and of system pressure is within ±21%. An acceptable H.P design may have a condenser heat flux of 1.16 k W/m2 with a corresponding system pressure of 1500 kPa.

تم تصميم و بناء منظومة أنبوب حراري للتدفئة المنزلية التي يستخدم الماء كمائع تشغيلي. أخذنا بنظر الاعتبار عند البحث التجريبي لأداء الأنبوب الحراري التغيرات في العوامل التشغيلية التالية:مختلف مستويات القدرة الداخلة إلى المسخن ومستويات مختلفة للمائع داخل المنظومة(Inventory) إضافة إلى زوايا ميل مختلفة (Inclination Angle ). النموذج النظري الذي تم تطويره يتمكن من حساب المعدل لدرجة الحرارة السطحية للمكثف tc) و ضغط المنظومة(P )في حالة الاستقرار.وتمت مقارنة النتائج العملية مع الحسابات النظرية ووجد أن النموذج النظري يستخدم الحرارة الكلية المسلطة على المسخن لتوقع ضغط المنظومة ودرجة حرارة المكثف ويعتبر هذا النموذج مناسب للأنبوب الحراري الوضع العمودي (0º =θ ) والنموذج الرياضي يعطي قيم بحدود (±15%) لدرجة الحرارة السطحية للمكثف و(±21%) لضغط المنظومة. نستنتج أن التصميم العملي المقبول لمنظومة التدفئة المنزلية يجب أن يكون ضمن حدود كثافة فيض حراري( 1.16kw/m2) خلال ضغط منظومة (1500 kpa) وزاوية ميل تتراوح بين(0-30º ).


Article
Design of a Percolator for Aqua-Ammonia Liquid

Authors: Ali S. Baqir --- Mikdam M. Saleh
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2005 Volume: 11 Issue: 1 Pages: 33-49
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A new design concept for a percolator is developed which combine the simultaneous production of ammonia vapor plus the pumping of weak aqua ammonia liquid. This steady state design was based on a balance between the hydrostatic driving head and the total signal and two-phase pressure losses in the percolator system. To accomplish this, the results from modeling of the driving pressure and pressure losses, using the separated flow and drift flux methods were compared with the experimental measurements. The Chisholm’s model was the best in predicting the measured flow rate versus water level for first stage with a maximum standard deviation of ± 10.1 % and was adopted for the theoretical calculations. Parametric design studies that include the cooling power and the strong solution level, inner tube diameter and height for each stage of the percolator were carried out to maximize suitable cost function. The results of the optimization gave a two stage percolator of length 280 mm, inner diameter 5.5 mm for first stage and length 520 mm, inner diameter 5.5 mm for second stage.

تم تطوير فكرة تصميم جديد لمبخر نفاث والذي يجمع بين انتاج بخار الامونيا وعملية الضخ لسائل امونيا ضعيف التركيز. ان تصميم الحالة الثابتة قام على اساس التوازن بين القوة الدافعة الهيدروستاتية وبين فقدان الضغط الناجم عن الجريان الاحادي والثنائي الطور في نظام المبخر. لغرض اتمام ذلك فان النتائج المستحصلة من عملية تمثيل للضغط الدافع وكذلك فقدان الضغط باستخدام الجريان المنفصل والجريان المنبثق الانحرافي تم مقارنة الحسابات النظرية بالقياسات العملية ياستخدام الماء كسائل العمل. لتحديد الموديل المناسب لفقدان الضغط تبين ان (موديل جزم ) يعتبر الافضل في التنبؤ بقياسات معدل الجريان مقابل مستوى الماء بالنسبة للمرحلة الاولى حيث ان الانحراف المعياري كان ± 10.1 % . ان استخدام التصميم البارامتري ( الذي يشمل على طاقة التبريد ، مستوى المحلول القوي، قطر الانبوب الداخلي وارتفاع كل مرحلة بالنسبة للمبخر) توصل الى ايجاد الابعاد المثلى للمبخر والمتمثلة بمبخر ذو مرحلتين بطول 280 ملم وبقطر 5.5 ملم بالنسبة للمرحلة الاولىوبطول قدره 520 ملم وقطر داخلي 5.5 ملم بالنسبة للمرحلة الثانية.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2007 (1)

2005 (1)