research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Flow injection spectrophotometric determination of Tetracycline hydrochloride in pharmaceutical samples
التقدير الطيفي الحقن الجرياني للتتراسايكلين هيدروكلورايد في النماذج الصيدلانية

Loading...
Loading...
Abstract

AbstractTetracycline hydrochloride (TCH) was determined spectrophoto-metrically in the pure form and in the pharmaceutical formulations using flow injection analysis (FIA). The automated method is based on the reaction between TCH, sodium nitroprusside and hydroxylamine hydrochloride in alkaline medium. The product absorbed maximally at 529 nm. The calibration graph of TCH is linear from 25-1000 µg mL-1 with detection limit (S/N=3) of 7.589 µg mL-1 and sample through put of 69 h-1. The various chemical and physical variables were optimized and the proposed procedure was applied successfully for estimation of drug in different commercial forms.

الخلاصةتم تقدير التتراسايكلين هيدروكلورايد بشكله النقي وفي المستحضرات الصيدلانية طيفيا باستخدام تقنية التحليل بالحقن الجرياني.تعتمد الطريقة المؤتمتة على التفاعل بين التتراسايكلين وهيدروكسيل امين هيدروكلورايد في الوسط القاعدي.الناتج اعطى اعلى امتصاص عند 529 نانومترا وبلغ مدى الخطية من 25-1000 مايكروغرام من التتراسايكلين هيدروكلورايد لكل مللتر من المحلول وبحد كشف 7.589 مايكروغرام مل-1 وبمعدل نمذجة 69 نموذج بالساعة.تمت دراسة جميع التغيرات الفيزيائية والكيميائية وتم تطبيق الطريقة وبنجاح لتقدير الدواء بمختلف اشكاله التجارية.


Article
Spectrophotometric Determination of Chloramphenicol in Pharmaceutical Preparations
التقدير الطيفي للكلورامفنيكول في المستحضرات الصيدلانية

Loading...
Loading...
Abstract

Abstract Two simple, rapid and sensitive spectrophotometric methods have been developed for the determination of chloramphenicol (CAP) in pure form and in pharmaceutical preparations. The proposed methods are based on a coupling reaction between reduced chloramphenicol (by zinc powder and concentrated hydrochloric acid) with chromatropic acid or phenol in the presence of ammonium hydroxide to form an intense red violet or yellow color, water-soluble dyes that are stable and have a maximum absorption at 515 nm using chromatropic acid and 432 nm on using phenol. The calibration graphs were linear over the concentration ranges of 0.52 -12 µg mL-1 and 0.4- 18µg mL-1 with a limit of detection (LOD) of 0.1334 µg mL-1 and 0.0873 µg mL-1 for chromatropic acid and phenol, respectively. The proposed methods were successfully applied to the determination of CAP in ointment and eye drops.

الخلاصة تم تطوير طريقتين تحليليتين للتقدير البسيط و السريع و الحساس للكلورامفنيكول بصورته النقية وفي المستحضرات الصيدلانية. اعتمدت الطريقة الاولى على تفاعل الازدواج بين الكلورامفنيكول المختزل (باستخدام الزنك مع حامض الهيدروكلوريك المركز) والمؤزوت مع كاشف حامض الكروماتروبك والثانية على كاشف الفينول في الوسط القاعدي لتكوين صبغة حمراء بنفسجية او صفراء مستقرة وذائبة في الماء اعطت أقصى امتصاص عند طول موجي 515 نانومتر للكاشف حامض الكروماتروبك و432 نانومتر لكاشف الفينول0 يشير الرسم البياني للامتصاص مقابل التركيز بان قانون بير ينطبق ضمن المدى 52‚0 - 12 مكغم مل1- و 4‚0-18 مكغم مل1- وبحد كشف 1334‚0 مكغم مل1- و 0873‚0 مكغم مل1- للكاشفين حامض الكروماتروبك والفينول على التوالي. تم تطبيق الطرق المقترحة بنجاح في تقدير الكلورامفنيكول في المستحضرات الصيدلانية المرهم وقطرات العين.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2014 (2)