research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Determination of caffeine content in Baghdad Soft Drinks Company products using HPLC technique
تقدير كمية الكافائين في المشروبات الغازية لمنتجات شركة بغداد باستخدام تقنية HPLC

Author: Nuha .A. j .Imran نهى عبد الجليل عمران
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2013 Volume: 9 Issue: 3 Pages: 83-96
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

A high- performance Liquid chromatography method was employed for the quantitative determination of Caffeine in several soft drinks produced in Baghdad company such as Pepsi, Pepsi diet, seven, seven diet, Miranda orange and Miranda apple .The chromatographic analysis of caffeine was carried out after their sequential elution with 50% (Acetonitrile: water) as mobile phase by reverse- phase HPLC technique C8 Column and UV detection was made at 273nm. Calculated (RSD%) values for retention time was obtained between (0.104-0.515%) and (RSD%) for Peak Area was (1.319-7.741%) .

تم استخدام تقنية الكروماتوغرافيا السائلة عالية الاداء (HPLC) لقياس كمية الكافائين في المشروبات الغازية لشركة بغداد وهي البيبسي، البيبسي دايت, السفن, السفن دايت, الميرندا تفاح والميرندا برتقال ، وتم انجاز التحليل الكروماتوغرافي لقياس الكافائين باستخدام ( اسيتونتريل : ماء ) كطور متحرك 50% وعمود C8 كطور ثابت وبتحسس مقداره 273 nm كطول موجي لمقياس طيف UV . وتم حساب قيم الانحراف القياسي النسبي (RSD%) وقد تراوحت هذه القيم لزمن الاحتجاز Retention time ما بين ( (0.104-0.515% اما قيم (RSD%) لمساحة القمة Peak Area فكانت تتراوح بحدود( %1.319-7.741) .


Article
Optimum conditions for ascorbic acid determination in three Iraqi citrus using HPLC technique
الظروف المثلى لقياس حامض الاسكوربيك في ثلاثة انواع من الحمضيات العراقية باستخدام تقنية HPLC

Loading...
Loading...
Abstract

A high-performance liquid chromatography method was employed for the quantitative determination of ascorbic acid (AA) which called vitamin C in three types of Iraqi citrus (orange mandarin and aurantium ) and to establish this goal , evaluation of ascorbic acid degradation is so important due to its significant criticality when exposure to ordinary atmospheric conditions. The chromatographic analysis of AA was carried out after their sequential elution with KH2PO4 ( as mobile phase) by reverse-phase HPLC technique with C8 column and UV detection at 214 nm. .Bad resolutions was appeared clearly for C8 column , so another alternative condition were carried out to improve the resolution by replacement of C8 by C18 column .Statistical treatments were used to calculate relative standard deviation (RSD%) for the results to gain acceptable confidence to the present work , so the linearity of calibration curve, accuracy, and repeatability of this method are all satisfactory.

تم استخدام تقنية (HPLC) لقياس كمية فيتامين C في ثلاث انواع من الحمضيات العراقية (البرثقال ، اللانكي والنارنج ) ، ولغرض تحقيق ذلك فلابد من تقييم حالة التكسر والتجزأ المهمة التي تحصل في حامض الاسكوربيك عند تعرضه للظروف الجوية الاعتيادية ، تم انجاز التحليل الكروماتغرافي لفيتامين C باستخدام KH2PO4 (كطور متحرك) والعمود C8 كطور ثابت وبتحسس مقداره 214 nm. كطول موجي لمقياس طيف . UVتداخل القمم كان واضحا باستخدام العمود C8 لذا كان التوجه لاستخدام ظروف بديلة تعززت باعتماد العمود C18 بغية الحصول على نتائج اكثر واقعية بازالة تداخل القمم .تم معاملة النتائج المستخرجة بالمعالجات الإحصائية لاحتساب نسبة الحيود النسبي (RSD%) وهي ضرورية لإضفاء مصداقية مقبولة على هذه النتائج والذي انعكس بدوره لبلوغ دقة مقبولة الى حد كبير على معاملة الخط المستقيم لمنحنى التوازن.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

English (1)


Year
From To Submit

2014 (1)

2013 (1)