research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Simulation of Turbulent Flow and Heat Transfer Through a Duct with Baffle Plates
نمذجة انتقال الحرارة للجريان المضطرب خلال مجرى ذو عوائق

Authors: . Khudheyer S. Mushatet خضير مشتت --- Qasim S. Mehdi قاسم صالح مهدي
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2008 Volume: 12 Issue: 3 Pages: 142-156
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

In this paper, a numerical study of the turbulent air flow and heat transfer through a duct with baffle plates is performed. The effect of baffles arrangement baffles number, baffle height and baffle thickness on the flow and heat transfer characteristics is investigated. The fully elliptic differential equations that describe the flow and heat transfer are integrated using the finite volume approach. The standard k-є model with wall functions has been submitted to model the turbulence. The obtained computed results show that the boundary layer separation and recirculation regions are significantly affected with the height, thickness and arrangements of the baffle plates. Also the results demonstrate that in the presence of the baffle, the heat is significantly enhanced. The bulk temperature values along the duct are decreased with the increase of Reynolds number for all the studied cases

في هذا البحث أجريت دراسة عددية للجريان الاضطرابي وانتقال الحرارة داخل مجرى هوائي يحتوي على صفائح إعاقة. تم دراسة تأثير ترتيب الصفائح، عدد الصفائح، المسافة بين الصفائح وطول الصفيحة وسمكها على خصائص الجريان الاضطرابي وانتقال الحرارة. تم دراسة المعادلات التفاضلية التي تصف الجريان وانتقال الحرارة بأستحدام إسلوب الحجم المحدد.عولج تأثير الاضطراب بأستحدام نموذج (k-є) مع دالة الجدار. بينت النتائج المستحصلة من هذه الدراسة أن انفصال الطبقة المتاخمة ومناطق إعادة التدوير قد تأثرت بصورة ملحوظة بارتفاع الصفيحة، سمك الصفيحة وترتيب الصفائح. كما بينت النتائج إن انتقال الحرارة قد ازداد مع وجود هذه الصفائح. أيضا لوحظ أن قيم متوسط درجة الحرارة على طول المجرى قد قلت مع زيادة رقم رينولدز

Keywords


Article
Experimental And Theoretical Investigation Of Composit Materials As Thermal Insulation For Resident Building
دراسة نظرية وعملية لمواد مركبة كعازل حراري لبناية سكنية

Loading...
Loading...
Abstract

This work involves a theoretical and experimental investigation of three types of composite laminated materials as thermal insulations for roofs. The composite consist of three types fiberglass with polyester resin. The first is of; random fiberglass type-1, (density of 659.3 kg/m3).The second is random fiberglass type-2, (density of 731.8 kg/m3) and the last is matt fiberglass,( density 1010.5 kg/m3). The theoretical investigation involved a study of the solar radiation received by the walls and roof, heat gain reduction of roof for the three types of composite materials at different variables; these involved the (insulation thickness, number of layers of composite insulation, volume fraction, and the air gap between roof and the insulation. The experimental investigation is divided into two parts: the first part included measurement of thermal conductivity of composite materials using Lee's disc method with different volume fraction. The second part included manufacturing of two rigs (reference rig and test rig) with dimension (1m x 1m x 1m height). Theoretical results proovs that the heat gain for the roof is more than that of the walls. Also the heat gain is decreased with different percentages depending on the type of insulation. Obviously the heat gain is decreased with using air gap. The thermal conductivity is increased with volume fraction theoretically and experimentally. Experimental result proofs that using random fiberglass type-1 is best in the present work. Also the air gap increases the efficiency of thermal insulation.

تمت دراسة نظرية وعملية لاختبار ثلاثة انواع من المواد الركبة كعوازل حرارية للسقوف. تتكون هذه المواد من الالياف الزجاجية وراتنج البولستر. انواع الالياف المستخدمة هي الياف زجاجية عشوائية نوع-1 وتبلغ كثافتها 659.3kg/m3 , الياف زجاجية عشوائية نوع-2 وتبلغ كثافتها 731.8 kg/m3, والياف زجاجية (حصيرة) ذات كثافة kg/m3 1010.5.تضمن الجزء النظري حساب كمية الاشعاع الشمسي المستلم عبر الجدران والسقف , وتحديد نسبة تخفيض الكسب الحراري للسقف عند استخدام العوازل الثلاثة لعدة متغيرات هي (سمك العازل,عدد طبقات الالياف في العازل, الكسر الحجمي, وجود فجوة هوائية بين العازل والسقف). يتضمن الجزء العملي قسمين: يتضمن القسم الاول قياس الموصلية الحرارية للمواد المركبة لعدة كسور حجمية باستخدام تقنية ( اقراص – لي). في القسم الثاني تم بناء هيكلين ابعاد كل منهما (1مx1مx1م ) , الهيكل الاول يعتبر مصدر اساس لدرجات الحرارة المقاسة اما الهيكل الثاني فيستخدم لاختبار العوازل الحرارية. اثبتت النتائج النظرية ان الحرارة المكتسبة عبر السقف مقارنة بالجدران هي الاكبر. كما ان الكسب الحراري عند استخدام العوازل الحرارية الثلاثة يقل بنسب متفاوتة وحسب نوع العازل. كما يقل الكسب الحراري بشكل ملحوض عند استخدام فجوه هوائية بين العازل والسقف. لوحظ ان الموصلية الحرارية للمواد المركبة تزداد بزيادة الكسر الحجمي لهذه المواد نظريا وعمليا. برهنت النتائج العملية ان استخدام الالياف الزجاجية

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (2)


Year
From To Submit

2010 (1)

2008 (1)