research centers


Search results: Found 15

Listing 1 - 10 of 15 << page
of 2
>>
Sort by

Article
Effect of Molybdate Anions On Corrosion Behavior of Stainless Steel 304 In 0.1M Nacl Solution
تأثير أيونات المولبيدات على السلوك التأكلي للحديد المقاوم للصدأ ( ٣٠٤) في محلول ٠.١ مولاري كلوريد الصوديوم

Author: Rana A. Majed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 16 Pages: 2931-2945
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The research was aimed to study the effect of molybdate ions (MoO4=) on corrosion behavior of SS 304 in 0.1M NaCl solution with six different concentration of molybdate ion in the range (0.01 – 0.3 M) at room temperature. Corrosion parameters such as open circuit potential (Eocp), corrosion potentials (Ecorr), corrosion current density (icorr) and Tafel slops (bc & ba)were measured and discussed. The polarization resistance (Rp) and rate of the corrosion in (mpy) values were calculated, the protection efficiency (P%) in solution NaCl containing molybdate anions was also estimated. All these parameters indicated role of molybdate as inhibitor material of corrosion SS 304 in NaCl solution and exhibit that the 0.03M MoO4 -2 has the best values of Rp, rate (mpy) and P%. The inhibition by molybdate was observed through adsorption process and formation of oxide layer on surface of Stainless Steel.

يتضمن البحث محاولة لدراسة تأثير أيونات المولبيدات على سلوك التأكل لسبيكة ٣٠٤ في ٠.٣ مولاري) بدرجة – 0.1 ) بستة تراكيز من المولبيدات ضمن المدى ( ٠.٠١ M NaCl) محلول وكثافة تيار التاكل (Ecorr) حرارة الغرفة. تم قياس ومناقشة بعض متغيرات التأكل مثل جهد التاكل ومعدل (Rp) كما تم حساب مقاومة الاستقطاب .(bc & ba) وميول تافل الكاثودية والانودية (icorr)سرعة التاكل بوحدة (ميل / سنة)، بالاضافة الى تقدير كفاءة الحماية في محلول كلوريد الصوديوم الحاوي على ايونات المولبيدات. هذه البيانات بينت دور المولبيدات كمثبط لتأكل الفولاذ المقاوم للصدأ ٣٠٤ في محلول كلوريد الصوديوم ووضحت بان اضافة تركيز ٠.٠٣ مولاري من المثبط اعطى افضل قيم لمقاومة الاستقطاب ومعدل السرعة المقاسة وكفاءة الحماية. ان دور التثبيط كان واضحاً من خلال عملية الامتزاز وتكوين طبقة السلبية على السطح المعدني. ان جميع القياسات تمت في درجة حرارة الغرفة.


Article
Galvanic Corrosion of Dental Alloys and Amalgam in Artificial Saliva Containing Citric Acid
التأكل الكلفاني لسبائك طب الاسنان والحشوة الزئبقیة في اللعاب الصناعي الحاوي على حامضالستریك

Author: Rana A. Majed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 12 Part (A) Engineering Pages: 2200-2310
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this work galvanic corrosion potentials and currents were measured usingpolarization curves of some dental alloys (amalgam, Co-Cr-Mo, Ni-Cr-Mo, SS 316L, Ti-6Al-4V alloys) in artificial saliva containing citric acid with three concentrations 3,6 and9 g/l at 37oC. All galvanic corrosion data were measured to coupling of amalgam andother alloys to investigate the galvanic corrosion between filling and other dental devicessuch as partial-denture framework, crowns, bridges, and endodontic instruments.The results of galvanic corrosion show that the coupling between amalgam and Ni-Cr-Mo alloy gives higher galvanic corrosion current than other metallic contact, and thenthe contact between amalgam and Co-Cr-Mo alloy was heavier compared with couplingof SS 316L and Ti-6Al-4V alloy with amalgam. The increasing of corrosion for alloyscontaining chromium due to rapidly converting of Cr6+ to Cr3+ and this phenomenondecreases the concentration of chromium ions at surface and then increases thedissolution of metal atoms, while decreasing of galvanic corrosion of Ti-alloy coupledwith amalgam due to the passive oxide surface layer (TiO2).


Article
EFFECT OF CHLORIDE IONS ON THE PASSIVE LAYER FORTHREE AL-ALLOYS AT PH=9

Authors: Rana A. Majed --- Ahlam M. Farhan --- Naema A. Hikmat
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2009 Volume: 12 Issue: 3 Pages: 23-32
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Abstract
This work involves the study of the effect of chloride ion on the passive layer
which is formed on the surface of three aluminium alloys (Al-Cu-Mg), (Al-Mg), and (Al-Zn). The
concentrations of chloride ion used were (1x10-3, 1x10-2, 0.1 mol.dm-3). The study was performed in
1x10-5 mol.dm-3 NaOH solution which was corresponded to pH value of (9). The data of
polarization behaviour were calculated by Tafel extrapolation method and the comparison of this
data in the absence and presence of chloride ions were discussed.


Article
Effect of Halogen Ions on The Corrosion of Brass In Na2SO4 Solution
تأثير أيونات الهالوجين على تأكل البراص في محلول كبريتات الصوديوم

Authors: Rana A. Majed --- Saad M. Elia --- Zahra`a Fadhel
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 7 Pages: 1386-1395
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research involves study effect of halogen ions presence in 0.2M sodiumsulphate on the corrosion of brass at room temperature (30oC). Three concentration ofhalogen ions (Fˉ, Clˉ, Brˉ, and Iˉ) were used 0.1, 0.2, and 0.3 M. The different incorrosion parameters before and after added the halogen ions interpreted anddiscussed which involves corrosion potentials (Ecorr), corrosion current densities(icorr), and Tafel slops (bc & ba) in addition to discuss the polarization curves.Polarization resistances (Rp) and the change in free energy (ΔG) werecalculated and interpreted, in addition to calculate the rate of corrosion (Rmpy).The results of this work indicates that the presence of halogen ions inexperimental solution increases the rate of corrosion, and the effect of halogen ionsfollows the sequence to increase the corrosion Iˉ > Clˉ > Fˉ > Brˉ.

يتضمن هذا البحث دراسة تأثير وجود ايونات الهالوجين في محلول 0.2 مولاري كبريتاتم). استخدمت ثلاثة تراكيز من ايونات o الصوديوم على تأكل البراص عند درجة حرارة الغرفة ( 30الهالوجينات (ايونات الفلوريد والكلوريد والبروميد واليوديد) وكانت 0.1 و 0.2 و 0.3 مولاري. تمتفسير ومناقشة متغيرات التاكل المقاسة والتي تضمنت جهود التأكل وكثافات تيار التأكل وميول تافلالكاثودية والانودية بالاضافة الى مناقشة منحنيات الاستقطاب.تم حساب قيم مقاومات الاستقطاب والتغير في الطاقة الحرة لكيبس وكذلك معدل سرعةالتاكل بوحدة المل لكل سنة. وقد بينت النتائج ان اضافة ايونات الهالوجين تؤدي الى زيادة معدلالتاكل والزيادة تتبع التسلسل التالي يوديد > كلوريد > فلوريد > بروميد.


Article
Effect of Deaeration on the Corrosion of Pure Aluminum and Its Three alloys in NaOH solution at pH=11
تأثير عدم التهوية على تأكل اللامنيوم النقي وثلاث من سبائكه في محلول هيدروكسيد ( الصوديوم عند أس هيدروجيني ( 11

Authors: Naema A. Hikmat --- Ahlam M. Farhan --- Rana A. Majed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 8 Pages: 1532-1543
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this work, the corrosion behaviour of pure Al and its three alloys (Al-Cu-Mg, Al-Mg, and Al-Zn-Mg) was studied in aerated and deaerated 1x10-3 mol.dm-3 NaOHsolutions to show the role of dissolved oxygen gas and its reduction at cathode. Also theaim of this study was to obtain the corrosion parameters such as the corrosion potential(Ecorr), corrosion current density (icorr), cathodic and anodic Tafel slopes (b), andpolarization resistance (Rp) besides the thermodynamic and kinetic functions were alsocalculated (ÄG, ÄS, and ÄH) and (Ea and log A) to comparison these values in thepresence and absence of the oxygen.From the general results for this study can be seen that the polarization resistances forpure Al and its alloys were higher in deaerated solutions and the values of (ÄG) wereless spontaneous in deaerated solution, also the activation energy (energy barrier) washigher in deaerated solution.

في هذا العمل تم دراسة السلوك التأكلي اللامنيوم النقي وثلاث من سبائكه (المنيوم-نحاس-مغنيسيومو المنيوم -مغنيسيوم و المنيوم-زنك-مغنيسيوم) في محلول هيدروكسيد الصوديوم في حالة التهويةوعدمها وذلك لمعرفة دور الاوكسجين المذاب وأختزاله الحاصل عند الكاثود . وقد تم حساب البياناتالخاصة بالسلوك الاستقطابي والممثلة بجهد التاكل وكثافة تيار التاكل وميول تافل ومقاومة الاستقطاب.كما تم حساب الدوال الثرموديناميكية والمتضمنة التغير في الطاقة الحرة لكيبس والتغير فيالانتروبي والانثالبي بالاضافة الى الدوال الحركية والتي تشمل حساب طاقة التنشيط ولوغاريتم ثابتارينيوس ومقارنة النتائج في حالة غياب ووجود الاوكسجين.وقد اظهرت ال نتائج عموماً، بان مقاومة الاستقطاب كانت اكبر في حالة المحاليل عديمة التهوية، كماوان قيم الطاقة الحرة لكيبس كانت اقل تلقائية بغياب الاوكسجين هذا بلاضافة الى ان قيم طاقة التنشيطوالتي تمثل حاجز الطاقة كانت اعلى في المحاليل عديمة التهوية.


Article
Effect of Different Coating Techniques with Aluminum on the Corrosion Behavior of Stainless Steel 316L in Seawater

Authors: Ali H. Ataiwi --- Abdul Khaliq F. Hamood --- Rana A. Majed
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2012 Volume: 15 Issue: 3 Pages: 112-122
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

This study involves effect of aluminum coating by using different techniques (Aluminizing, Flame spraying, and Hot dipping) on corrosion behavior of stainless steel 316L in seawater. Cathodic and anodic regions are studied by using potentiostat to measure the corrosion parameters through Tafel method which include open circuit potential (Eocp), corrosion potential (Ecorr), and corrosion current density (icorr) in addition to calculation of coating corrosion rates (R). The results indicate that the corrosion rate for coated specimens by aluminizing and flame spraying techniques were less than the values before coating but coating with hot dipping technique gives higher rate than the non coated samples, where the results take the following sequence:Corrosion coating sample < coating sample < coating sampleRate (μm/y) by using pack using flame spray using hot dipping cementation aluminizing The potentials with time were interpreted in order to study the evolution of the film chemistry as it came to equilibrium with solution where the results observed that the aluminum coating by aluminizing reaches to the steady – state faster than other samples. Also the galvanic current density with time were discussed where the results indicates, in general, the transients for specimens show an initial sharp decrease in galvanic current exhibited by all coated specimens followed by a more steady, but erratic decrease in the galvanic current

أن هذه الدراسة تضمنت أثر الطلاء بالألمنيوم باستخدام تقنيات مختلفة (الالمنة، الرش الحراري، التغطيس الساخن) على تصرف التآكل لسبيكة الفولاذ المقاوم للصدأ316L .تم دراسة المناطق الكاثودية والانودية باستخدام المجهاد الساكن لقياس متغيرات التآكل بطريقة تافل، والتي تضمنت جهد الدائرة المفتوحة (Eopc)،جهد التأكل (Ecorr)وكثافة تيار التأكل (icorr) إضافة إلى حسابات معدلات تأكل الطلاء (R).أوضحت النتائج أن معدل التآكل للعينات المطلية بتقنيات الالمنة والرش الحراري حقق قيما أقل من قيمه قبل الطلاء(للعينات غير المطلية)، ولكن الطلاء بتقنية التغطيس الساخن أعطت معدل أعلى حيث ان تسلسل حساب معدل تأكل الطلاء كان كما يلي:معدل التأكل(مايكرومتر/سنة) الطلاء باستخدام > الطلاء باستخدام > الطلاء باستخدام تقنية الالمنة الرش الحراري التغطيس الساخن لقد تم تفسير علاقة الجهود مع الزمن وذلك لدراسة الطبقة المتكونة على السطح في حالة التوازن مع المحلول وقد بينت النتائج ان السطوح المطلية بتقنية الالمنة تصل الى مرحلة التوازن اسرع من النماذج الاخرى المطلية بتقنيتي الرش الحراري والتغطيس الساخن. كما تم دراسة العلاقة بين كثافة التيار مع الزمن واظهرت النتائج عموماً حصول نقصان حاد في التيار يعقبه الوصول الى مرحلة التوازن مع حدوث نقصان شاذ في قيمة التيار ولجميع العينات المطلية.


Article
Experimental and Numerical Study of CO2 Corrosion in Carbon Steel
دراسة نظریة وعملیة لتأكل الستیل الكاربوني بفعل غاز ثاني اوكسید الكاربون

Authors: Dalia M. Jomaa --- Ali H. Jawad --- Rana A.Majed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 15 Part (A) Engineering Pages: 2885-2904
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research involves study corrosion of low carbon steel under static and flowconditions at 200L/h in the absence and presence of CO2 at two rates 9 and 30 ml/minat four temperatures by electrochemical method using potentiostat. Numerical modelwas achieved to compare between the experimental and theoretical results to estimatecorrosion rate. The results show that the presence of CO2 under static conditionsshifts the Ecorr toward noble direction, while under flow condition the presence of CO2shift Ecorr toward active or noble direction at two rates of gas. The data of corrosionrate in mm/y indicate that the presence of CO2 with two flow rate increased the ratecompared with the case of absence of CO2 under static conditions except one case,while under flow conditions, the presence of 9 ml/min. CO2 increases the corrosionrate, while the presence of 30 ml/min. CO2 decreases the rate because of formationFeCO3 scale except at 298K. A Mathematical model was done which show thevolumetric flow rate of CO2 and finally the corrosion rate of CO2 correlated withdimensionless groups and independent parameters.


Article
Effect of Uric acid Level on the Corrosion Behavior of SS 316L and Co-Cr-Mo Used in Implant Applications
تأثیر مستوى حامض الیوریك على السلوك التأكلي للصلب المقاوم للصدأ 316L وسبیكة Co-Cr-Mo المستخدمة في تطبیقات الزروع الجراحیة

Authors: Kahtan K. Al-Khazraji --- Rana A. Majed --- Zina Noori Abdulhameed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 17 Part (A) Engineering Pages: 3382-3390
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this study electrochemical behaviors of SS 316L and Co-Cr-Mo alloys werestudied using electrochemical method by potentiostat in simulated body fluid (SBF) atpH=7.4 and 37oC in absence and presence of 7 and 12 g/dL uric acid which causesarthritis. Corrosion parameters for two implants were calculated which includecorrosion potentials (Ecorr), corrosion current densities (icorr), cathodic and anodic Tafelslops (bc & ba), polarization resistance (Rp) and corrosion rates (CR).Increases uric acid in human body gives decreasing in corrosion rate for SS 316Lbecause of formation organometallic complexes between acid molecules and releasedmetal ions, but an increase in corrosion rate for Co-Cr-Mo alloy because of low affinityof cobalt ions to formation organometallic complexes. General comparison betweentwo implants shows that the Co-Cr-Mo alloy has lower corrosion rate than SS 316L inthe same conditions due to Cr content. This means that using Co-Cr-Mo alloy betterthan SS 316L as bioimplant.


Article
Effect of Laser Surface Modification on the Corrosion Resistance of Dental Alloys in Artificial Saliva Containing Alcoholic Beverages
تأث رٍ المعاملة السطح ةٍ الل زٍر ةٌ على مقاومة التأكل لسثائك طة الاسىان ف اللعاب الاصطىاع الحاوي على المشروتات الكحول ةٍ

Authors: Ali H. Ataiwi --- Rana A. Majed --- Ali A. Muhsin
Journal: Iraqi Journal of Laser المجلة العراقية لليزر ISSN: 18121195 Year: 2013 Volume: 12 Issue: A Pages: 43-52
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Abstract: The objective of this study is to demonstrate the corrosion behavior of dental alloys Co-Cr-Mo, Ni-Cr-Mo and Ti-Al-V in artificial saliva at pH=4 and 37oC enriched with ethyl alcohol at 8% percentage. The linear and cyclic polarizations were investigated by electrochemical measurements. Laser surface modification was achieved for the three dental alloys to improve corrosion resistance. The results show that corrosion resistance of Co-Cr-Mo and Ni-Cr-Mo alloys only were increased after laser treatment due to the fact that laser radiation has caused a smoother surface, in addition to the decrement in corrosion current densities (icorr) for Co-Cr-Mo and Ni-Cr-Mo alloys and the reverse scan in cyclic polarization became in the wider range of potentials compared with the reverse scan for untreated dental alloys, in addition to the obtainment of smaller hysteresis loop for Ti-Al-V alloy.

الخلاصة هَذف هذا اىجحث اى دراسة سيىك اىحأمو ىثلاثة سجبئل طت الاس بْ ) Co-Cr-Mo, Ni-Cr-Mo, Ti-Al-V ( ف اىيعبة الاصط بْع ع ذْ اص ه ذُروج 4 و 34 درجة ئٍى ةَ واىحبو عي 8% محىه الا ثَب ىّه. ج دراسة الاسحقطبة اىخط واىحيق ثبىطز قَة اىنهزوم بَُُئ ةُ واجز ثَ اى عَب يٍة اىسطح ةُ اىي شُر ةَ ىيسجبئل اىثلاثة ىححس قٍبو ةٍ اىحبمو ف اىيعبة اىحبو عي اى شَزوثبت اىنحىى ةُ. اظهزت اى حْبئج ا قٍبو ةٍ اىحأمو اسدادت ىسج نُة اىنىثيث مزو ىًٍى جُذ ىُّ و سج نُة نُّو مزو ىًٍى جُذ ىُّ فقط - - - -ثعذ اى عَب يٍة اىي شُر ةَ ثسجت الاشعبع اىي شُر اىذ سجت اى عْى ةٍ اىسطح ةُ، ثبلاضبفة اى قّصب مثبفبت ج بُر اىحأمو، وا اى سَحاىعنس ف الاسحقطبة اىحيق اصجح ث ذَي اوسع اىجهذ قٍبر ةّ عٍ الاسحقطبة اىحيق ىيع بُْت غ زُ اى عَب يٍة ثبىي شُر ىيسج نُح الاخ زُج ثبلاضبفة اى قّصب اىحيقة اىهسح زُ ةَ ىسج نُة اىح حُب ىُّ اًى ىَُْ فً بْد ىَ .ً

Keywords


Article
Effect of Some Anti-Inflammatory Drugs on The Corrosion Behavior of Implant Biomaterials in Human Body Fluid
تأثير بعض الادوية المضادة للالتهاب على سلوك تاكل المواد الحيوية المزروعة في محيط جسم الانسان

Authors: Kahtan K.Al-Khazraji --- Ali H. Ataiwi --- Rana A. Majed --- Zina Noori Abdulhameed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 6 Pages: 959-973
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The aim of this research is to compare the electrochemical behavior of two surgical implant biomaterials alloys, SS 316L and Co–Cr–Mo alloy in simulated body fluid. This comparison is focused on the influence of presence of three anti-inflammatory drugs, aspirin (C9H8O4), paracetamol (C8H9NO2), and mefenamic acid (C15H15NO2) with threeconcentrations of each drug (0.00303, 0.00606, and 0.01212), (0.0086, 0.0172, and 0.0344), and (0.00111, 0.00156, and 0.00201) g/300ml respectively at pH=7.4 and 37oC using electrochemical techniques, potentiodynamic curves and potentiostatic tests. Influence of these drugs on both biomaterials depends on the formation oforganometallic complexes between released metals ions from implant alloys and drugs molecules. The study shows that the drugs behave as inhibitors for SS 316L through the measured corrosion parameters, while gives irregular behavior in the case of Co – Cr – Mo alloy. However, difference between two alloys appear with different affinity ofreleased metal ions to binding with other molecules inside human body.

Listing 1 - 10 of 15 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (15)


Language

English (12)

Arabic and English (2)


Year
From To Submit

2014 (3)

2013 (5)

2012 (2)

2010 (1)

2009 (3)

More...