Optimal Size and Location of Distributed Generators using Intelligent Techniques
ألموقع والحجم ألامثلین للمولدات الموزعة بأستخدام التقنیات الذكیة

Authors: Rashid H. Al-Rubayi --- AzharM. Alrawi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 23 Pages: 6623-6633
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

One of the modern and important techniques in electrical distributionsystems is to solve the networks problem of service availability, high loss and low voltage stability by accommodating small scaled de-centralized generating units in these networks, which is known as distributed generation (DG). The Genetic Algorithm (GA) technique is dedicated in this work to find the optimal DG locations, and then optimally allocate units in order to maximize the penetrationlevel, minimize loss, and improve voltage stability

یعتبر اضافة الوحدات التولیدیة الصغیره غیر المركزیھ في انظمة توزیع الطاقة الكھربائیة من أھم وأحدث الستراتیجیات الحدیثة لحل مشاكل تلك الانظمة من نقص التولید وزیادة الخسائر وضعف استقراریة الفولتیة , وتعرف تلك الستراتیجیة بالمولدات الموزعة.نتیجة للتطور والنمو في شبكات التوزیع فأن دراسة عملیة أضافة المولدات الموزعة ھي دراسة معقده من الناحیتین التقنیة والریاضیة , ونتیجة لذلك تم استخدام تقنیة الخوارزمیة الجینیة لتحدید أمثل المواقع للاضافة ثم اختیار افضل الاحجام لتلك المولدات لامداد الشبكة باقصى قدرة تولیدیة ممكنة وتقلیل الخسائر لاقل مایمكن و تحسین استقراریة الفولتیة


Article
Damping of Power System Oscillations by Using Coordinated Control of PSS and STATCOM Devices
اخماد تذبذبات منظومة القدرة بتنسيق السيطرة PSS وجهاز STATCOM

Authors: Rashid H. Al- Rubayi --- Inaam Ibrahim Ali
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 23 Pages: 6814-6830
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The main objective of this paper is to investigate the power system stability enhancement via coordinated control of PSS and static synchronous compensator (STATCOM) based controllers. Also, investigate the effectiveness and dynamic interaction of STATCOM controllers in damping system oscillation. Proposed optimal pole shifting technique to design damping controller of excitation system (PSS) and STATCOM basedcontroller. The method is based on modern control theory for multi-input and multi-output system. Several control schemes are proposed. The effectiveness of the proposed control schemes in improving the power system is verified through eigenvalues and time domain simulations under nominal loading conditions. The analysis of cases under study show that, the STATCOM – based controller has good effect on improving system damping and the coordinated control of PSS and STATCOM – based controller provide the best means forstabilizing power system, more damping with less control effort than individual control


Article
Enhancing the Stability Performance of Iraqi National Super Grid System by Using UPFC Devices Based on Genetic Algorithm
تحسين اداء الاستقرارية للشبكة الوطنية العراقية بواسطة إستخدام أجهزة (UPFC)إستنادا على الخوارزمية الوراثية

Authors: Rashid H. Al-Rubayi --- Abdulrazzaq F. Noori
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 10 Part (A) Engineering Pages: 1837-1853
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The object of this work is to improve the stability of the Iraqi National Super Grid System (INSGS) by installing Unified Power Flow Controller (UPFC) devices in different optimal locations under fault condition and comparing the results with those of without FACTS under the same condition.The optimal location of the FACTS device was specified based on Genetic Algorithm (GA) optimization method, it was utilized to search for optimum FACT parameters setting and location based objective function that depends on the power and voltage as a fitness constraints.MATLAB was used for running both the GA program and Power System Analysis Toolbox (PSAT) as Graphical User Interface, Newton Raphson method also used for solving the load flow of the system and the Trapezoidal method for the non-linear differential equations.The system that has been implemented is INSGS 11-machine, 24-bus, 39 (400kV) overhead transmission lines.The GA program is applied for the Iraqi grid system which is complicated.The results obtained showed that the installation of UPFC devices at the optimal locations of the Iraqi grid gives an improvement in the stability by damping the voltage and rotor angle oscillations after subjected to the three phase fault to ground at different locations and different cases (temporary fault, permanent fault).A comparison has been made between these different cases based on the durations of the tested faults, and with the UPFC devices installed in the system, it can remain stable for longer time than without UPFC during fault condition.

الغرض من هذا العمل هو تحسين استقرارية منظومة القدرة للشبكة العراقية عن طريق نصب أجهزة الـ(FACTS) في أماكن مثالية مختلفة تحت ظرف الخطأ ومقارنة النتائج مع تلك التي لاتسخدم هذه الاجهزة في نفس الظروف.تم تحديد الموقع الأمثل لهذه الأجهزة إعتماداً على الصيغة الامثلية العامة تعرف بالخوارزميات الجينية (Genetic Algorithm), وتم استخدامها للبحث عن الخصائص والمواقع المثلى على أساس الدالة الموضوعية(Objective Function) التي تعتمد على القدرة والفولتية كمحددات(Fitness Function).تم استخدام برنامج الـ MATLAB لتشغيل كل من برنامج الـ(GA) والـ(PSAT) كواجهة رسم للمستخدم, كما تم أستخدام طريقة (Newton Raphson) لحل تدفق الحمل للنظام وطريقة (Trapezoidal) للمعادلات التفاضلية غير الخطية. وقد تم تنفيذ البرنامح على منظومة الشبكة الوطنية العراقية.تم تنفيذ برنامج الـ(GA) على منظومة الشبكة الوطنية العراقية.أظهرت النتائج التي تم التوصل إليها أن تركيب أجهزة الـUPFC)) في المواقع المثلى للشبكة العراقية تؤدي إلى تحسين الأستقرارية عن طريق زيادة إخماد الترددات الحاصلة للفولتية وزاوية الدوار((Rotor Angle بعد التعرض لخطأ من نوع (Three phase to ground) لحالات ومواقع مختلفة (خطأ مؤقت و خطأ دائم), وقد تم إجراء مقارنة بين هذه الحالات المختلفة إستناداً إلى فترات الأخطاء التي تم أختبارها, بالأضافة إلى ذلك ومع وجود أجهزة الـ(FACTS) يمكن للنظام أن يبقى مستقراً لفترة أطول من حالته بدون هذه الأجهزة بإستخدام نفس نوع الخطأ.


Article
Protection Coordination with Distributed Generation in Electrical System of Iraqi Distribution Grid

Authors: Rashid H. Al-Rubayi --- Ammar Abbas Majeed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 6 Part (A) Engineering Pages: 1161-1181
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The nature characteristic in conventional distribution networks is radial by single source supplying a downstream network. The interest about the environmental impacts and development in technologies have led to increase distributed generation (DG) interconnected in distribution networks. Protective device coordination will be affected by adding DGs to the existing network through participating to the change in direction of power flow and fault current values and direction which cause loss in settings and mis-coordination for protective devices, especially over current relays. The effect of DG on coordination depend upon number, location and size of DG, so in this work, the Particle Swarm Optimization (PSO) technicality utilization to locate optimal location and sizeof DG to obtain minimum active power losses.The Time Current Characteristic (TCC) curves represented which depended on the over current protection relays parameters to find settings and limited any loss in it, in order to reset these relays to obtained the proper operation without intersections in time of operation and satisfy optimal coordination between primary and pack up over current protection relays.In this work two soft wares are used, the first is Matlab R2014a for implementation of the PSO algorithm while the second software is CYMDist program for load flow analysis, short circuit current calculation and protection coordination device analysis. To verify the developed algorithm parts from Iraqi distribution network (Baghdad Al-Rusafa 33KV distribution networks). So, used two DG units with total capacity 50MW distributed in 33kV of South Al-Rusafa distribution network which represented about 9.4% from the total load of this network 533.5MW, the total active power losses reduced from 11.597MW to 6.658MW with losses reduction 6.96MW about 43% from total losses.


Article
Optimal Location and Parameter Setting of STATCOM Device Based PSO for Iraqi Grid Voltage Profile Enhancement and Power Losses Minimizing

Authors: Rashid H. Al-Rubayi --- Mohammed B. Eesee
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2019 Volume: 37 Issue: 2 Part (A) Engineering Pages: 60-69
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The main goal of this work is to enhance the Voltage stability by usingoptimum location and parameters setting of STATCOM device. The parametersare the magnitude of the output voltage ��� and the angle ���, these parametersare taken to control the device performance. The simulation results have beendone by using power flow program solution by Newton-Raphson method (Matlabprogram / M-file) with Particle Swarm Optimization (PSO) technique, for powerlosses minimizing and improving voltage profile. Two systems have beenimplemented:- IEEE 5-bus test system and Iraqi (400 kV) National super GridSystem 27-bus. The MATLAB programs are Applied in the first step on IEEE 5-bus test system to examine the performance of the programs by comparing theresults with other references, then it is implemented on Iraqi (400 kV) Nationalsuper Grid System to find optimum location and parameter setting of STATCOMdevice. The results show that, the STATCOM has significant effect on improvingthe voltage profile and reducing apparent power losses, The STATCOM deviceperformance depends on its location and parameter settings, and The PSOalgorithm can easily find out the optimal location and parameters setting ofthe STATCOM for which the voltage deviation are minimum.


Article
Voltage Stability Study of the Iraqi Power Grid
دراسة أستقرارية الفولتية لشبكة القدرة العراقية

Authors: Rashid H. Al-Rubayi --- Humam A. Al-Baidhani
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 2 Pages: 312-324
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

It has become an important task for many voltage stability studies to find avoltage stability index. The voltage stability indices provide reliable informationabout proximity of voltage instability in a power system. In this paper, the Lindicator has been proposed, which aims to detect the weakest load buses in theelectrical power networks. The L indicator has been checked by its application tothe (WSCC 9-bus and IEEE 14-bus) test systems. Finally, the proposed indicatorhas been applied to the Iraqi power grid (400 kV) considering differentcontingencies, such as lines outage, generated power reduction and loadingincrease. The short computation time of this indicator and its efficient detection ofthe weakest load buses in the Iraqi power grid, allow the operators to apply it in onlinevoltage stability monitoring based on measurements.

أن أيجاد دليل لأستقرارية الفولتية في العديد من الدراسات المتعلقة في أستقرارية الفولتية قدأصبح من المهام الضرورية. أن هذه الدلائل تعطي معلومات وثيقة عن مدى اقتراب نظام القدرةوالذي يهدف إلى ،(L indicator) من عدم أستقرارية الفولتية. في هذا البحث، تم اقتراح الدليلL ) الكشف عن قضبان الأحمال الضعيفة في شبكات القدرة الكهربائية. لقد تم التحقق من الدليلأخيراً، تم .(IEEE 14-bus) و (WSCC 9-bus) بتطبيقه على منظومتي الاختبار (indicatorتطبيق الدليل المقترح على شبكة القدرة العراقية فائقة الفولتية ( 400 كيلو فولت) مع أخذ بعضالحالات الطارئة بنظر الاعتبار كخروج خط نقل من الخدمة وحدوث نقص في توليد القدرة وزيادة الأحمال. أن زمن الحساب القصير لهذا الدليل وكفاءته في تشخيص العقد الضعيفة لشبكةالقدرة الكهربائية العراقية تتيح للمشغلين بتطبيقه لمراقبة أستقرارية الفولتية آنيا ً إعتماداً علىالقياسات.PDF created


Article
Robust-Load Frequency Controller Design For Iraqi National Super Grid System

Authors: Rashid H. Al-Rubayi --- Lokman H. Hassan Al-Sharafany
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2008 Volume: 26 Issue: 3 Pages: 305-325
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This work is intended to design a new robust load-frequency controller forIraqi National Super Grid System with uncertain parameters. Riccati equationapproach to the stabilization of uncertain system is proposed. Robust controller thatensures stability of the closed-loop system for all admissible structured uncertaintiesis designed. ‘Matching conditions’ and Lyapunov stability theory are used toimplement a robust stabilizing controller. Participation factor is used to address theinteraction between the state variables and the modes in the power system. Thisproperty is used to choose weighting matrix of the state variables (Q). A linear, time,invariant mathematical model is derived for Iraqi National Super Grid Systemconsisting of six generating stations with various types of turbines. The proposedapproach is applied to this system and simulation program is built to evaluate itseffectiveness.

تم إجراء البحث لتصميم مسيطر محكم للتحكم في تردد الشبكة الوطنية العراقية الفائقةالفولتية المتكونة من عدة مناطق عند تعرضها إلى تغير مستمر في الحمل مع الأخذ بنظرفي قيم العناصر المختلفة. اقترحنا معادلة ريكاتي (Uncertainty) الاعتبارمبدأ عدم التًَاكدلتحقيق استقرارية المنظومات (Riccati)صمم مسيطر محكم يضمن استقرارية المنظومات المغلقة .(Uncertain systems) غيرالمؤكدةولما مسموح به من قيم غير المؤكدة للعناصر المختلفة. أستخدمت الشروط التوافقيةللاستقرارية في بناء المسيطر المحكم . Lyapunov و نظرية (Matching conditions)طريقة لإيجاد مدى تأثير متغيرات المنظومة في (Participation factor) استخدمتها معامل التوزيعلمتغيرات Weighting matrix كل جذر من جذور المنظومات. استخدمت هذه الخاصية في أختيارالمنظومة. اشتق النموذج الرياضي الخطي والغير معتمد على الزمن لمنظومة الشبكة العراقية الفائقةالفولتية والمؤلفة من ست وحدات توليد مع أنواع مختلفة من التوربينات. طبقت الطريقة المقترحةعلى هذه المنظومة لبيان فعاليتها

Keywords


Article
ROBUST-LOAD FREQUENCY CONTROLLER DESIGN FOR IRAQI NATIONAL SUPER GRID SYSTEM

Loading...
Loading...
Abstract

Abstract:This work is intended to design a new robust load-frequency controller for Iraqi NationalSuper Grid System with uncertain parameters. Riccati equation approach to thestabilization of uncertain system is proposed. Robust controller that ensures stability of theclosed-loop system for all admissible structured uncertainties is designed. ‘Matchingconditions’ and Lyapunov stability theory are used to implement a robust stabilizingcontroller. Participation factor used to address the interaction between the state variablesand the modes in the power system. This property is used to choose weighting matrix of thestate variables (Q). A linear, time, invariant mathematical model is derived for IraqiNational Super Grid System consisting of six generating stations with various types ofturbines. The proposed approach is applied on this system and simulation program is builtto evaluate its effectiveness.

الخلاصـــــة:تم إجراء البحث لتصميم مسيطر محكم للتحكم في تردد الشبكة الوطنية العراقية الفائقة الفولتية المتكونة من عدة مناطق عند تعرضها إلى تغير مستمر في الحمل مع الأخذ بنظر الاعتبارمبدأ عدم التاًَكد ((Uncertainty في قيم العناصر المختلفة. اقترحنا معادلة ريكاتي ((Riccati لتحقيق استقرارية المنظومات غيرالمؤكدة (Uncertain systems). صمم مسيطر محكم يضمن استقرارية المنظومات المغلقة ولما مسموح به من قيم غير المؤكدة للعناصر المختلفة. أستخدمت الشروط التوافقية ((Matching conditions و نظرية Lyapunov للاستقرارية في بناء المسيطر المحكم. يقترح معامل التوزيع (Participation factor) طريقة لإيجاد مدى تأثير متغيرات المنظومة في كل جذر من جذور المنظومات. استخدمت هذه الخاصية في أختيار Weighting matrix لمتغيرات المنظومة. اشتق النموذج الرياضي الخطي والغير معتمد على الزمن لمنظومة الشبكة العراقية الفائقة الفولتية والمؤلفة من ست وحدات توليد مع أنواع مختلفة من التوربينات. طبقت الطريقة المقترحة على هذه المنظومة لبيان فعاليتها

Keywords


Article
Stability Improvement Of the (400kV) Iraqi Grid using the best FACTS Devices
تحسين إستقرارية منظومة الشبكة العراقية (KV 400) بأستعمال افضل جهاز من اجهزة ال FACTS))

Authors: Rashid H. Al-Rubayi --- Shaimaa Sh. Abd Alhalim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 7 Part (A) Engineering Pages: 1598-1618
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electrical power system has become large and complicated, so it is subjected to sudden changes in load levels. Stability is an important concept which determines the stable operation of the power system.The modern trend is to employ by installing Flexible Alternating Current Transmission System (FACTS) devices in the system for effective utilization of transmission resources.The FACTS devices contribute to the power flow improvement besides, they extend their services in transient stability improvement as well, study and analyze the stability of the system through rotor angle and voltage .The object of this work is to improve the stability of the Iraqi National Super Grid System (INSGS) by using optimal FACTS devices in different optimal locations under fault conditions.Two test systems are studied, the first system is IEEE or WSCC (9-bus bars), and the second system is the Iraqi (400 KV) electrical network 24-bus bars.The load flow program was implemented using the Newton-Raphson method and the numerical solutions of non-linear differential equations are solved using Trapezoidal method.A comparison has been made between five types of FACTS (UPFC, SSSC, TCSC, SVC, STATCOM) at optimal location of the Iraqi grid and (9-bus bars) to get optimal FACTS devices by (voltage stability, rotor angle ).The results obtained showed that the installation of Unified Power Flow Controller (UPFC) is optimal devices for an improvement of the stability by damping the voltage and rotor angle oscillations.

يعتبر نظام القدره الكهربائيه من الانظمه الضخمه والمعقده لاحتوائها على عدد كبير من محطات التوليد وخطوط النقل وأجهزة السيطرة لذلك فانه يخضع الى تغيرات مفاجئه في مستويات الحمل ، حيث اصبح من الصعب جداً الحفاظ على نظام مستقرمع التغيرات التي يشهدها النظام, لذلك فمن المهم جداً تحسين أستقرارية منظومة القدرة.التطور الحديث في نظام القدره الكهربائيه هو عن طريق تنصيب اجهزة ال(FACTS ) في اماكن مثاليه مختلفه حيث تساهم هذه الاجهزه الكهربائيه في تحسين تدفق القدره الكهربائيه الى جانب تحسين الاستقرارية العابره عن طريق الفولتية وزاوية الدوار الغرض من هذا العمل هو تحسين استقرارية منظومة القدرة للشبكة العراقية عن طريق استخدام افضل جهاز للـ(FACTS) ونصب هذه الاجهزه في اماكن مثاليه مختلفة تحت ظرف الخطأ تم دراسة منظومتان, المنظومة الأولى هي(IEEE or WSCC ) المكونة من (9) عقدة والمنظومة الثانية هي الشبكة الوطنية العراقية( 400 KV) المكونه من (24) عقدة ,في المنظومتان تم اختبار عطل ثلاثي الأطوار عند مواقع مختلفة و حالات مختلفة (عطل وقتي, عطل دائم) . تم في هذا البحث دراسة وتكوين برنامج لسريان الحمل(Load Flow) باستخدام طريقة (Newton-Raphson) وتم حل المعادلات التفاضلية الغير خــطـيــــة باســتــخــدام الطـرق العــدديــــــة وذلـك باســتــخــدامطــريـقــة (Trapezoidal) . البرامج المستخدمة في هذا البحث تم تطبـيـقــهــا باستخدام برنامج MATLAB (7.11.0.584 ) اصدار(R2010b) المبني على اساس برامجيات (PSAT version 2.1.6)( 2002-2010 (©. في هذا البحث تم المقارنه بين خمسة انواع من ال FACTS)) هي UPFC, SSSC, TCSC, SVC, STATCOM)) وتنصيبها في اماكن مثالية ومختلفه في الشبكه الوطنيه العراقية ومنظومة (9) عقدة للحصول على جهاز مثالي لتحسين القدره المنقوله والمقارنة تمت عن طريق الفولتية وزاوية الدوار.

Keywords

FACTS --- UPFC --- SSSC --- STATCOM --- TCSC --- SVC --- PSAT