research centers


Search results: Found 9

Listing 1 - 9 of 9
Sort by

Article
Experimental Investigation of Two-Phase Flow (Gas –Liquid) Around A Straight Hydrofoil In Rectangular channel

Author: Riyadh S. Al-Turaihi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2013 Volume: 21 Issue: 5 Pages: 1531-1545
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This paper includes experimental investigation to study the effects of air and water discharge for different angle of attacks for straight hydrofoil and built an experimental rig to study the two phase flow. In this work three different angle of attack (θ = 0°, 15° and 30°) are considered .The water discharge (Qw) at different quantities (Qw=12, 17, 27 and 37 L/min) and different air discharge (Qa=5, 15, 25 and 35 L/min) were taken. The maximum inlet velocity at the test section for air is (4.758 m/s) and for water is (1.217 m/s). The results show that when the angle of attack increase at constant amount of air and water discharge the pressure difference increased at inlet and outlet the rectangular channels. The results explain that when both water and air discharge at constant angle of attack the pressure difference increased at inlet and outlet the rectangular channels.

يتضمن البحث دراسة عملية لدراسة تأثير كل من معدل جريان الماء والهواء حول جناح مستقيم داخل قناة مستطيله شفافه لعدة زوايا ميلان للجناح و بناء منظومة للجريان ثنائي الطور.النتائج العملية تم أخذها باستخدام عدة زوايا هجوم (θ = 0°, 15° and 30°) و باستخدام عدة كميات من الماء (Qw=12,17,27and37) لتر/دقيقة و عدة كميات من الهواء (Qa=5, 15, 25 and 35) لتر/دقيقة و باستخدام أقصى سرعة جريان للهواء بمعدل 4.758 م/ثا و سرعة ماء 1.217 م/ثا.لقد بينت النتائج بان زياده كل من زاويه الهجوم للريشه بثبوت كل من كمية الماء والهواء او زيادة معدل جريان الهواء بثبوت كل من زاوية الهجوم و معدل جريان الماء او زبادة معدل جريان الماء( Qw) بثبوت كل من زاوية الهجوم و معدل جريان الهواء(Qa ) فان فرق الظغط على طرفي القناة الدقيقه يزداد.


Article
Experimental and Numerical Investigation of Four- Phase Flow (Water–Gasoline-Air-Solid) in a Fluidized Bed Column

Author: Riyadh S. Al-Turaihi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2016 Volume: 24 Issue: 1 Pages: 164-182
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper four phase fluidized bed is experimentally built and numerically modeled to study the bed characteristics such as ratio (the static bed height of solid particle / the bed diameter (H/D)), air, gasoline , and water superficial velocity. The test pipe for the experimental rig is Perspex pipe with 1 m long and 0.0254 m diameter. The 2D numerical model has been established with Ansys fluent 15.0. Pressure drop equation is found to relate the pressure drop with the bed parameters with deviation of 22%. The Four-phases was represented by air, water, gasoline and solid particle. The results show that the pressure of the bed increases as the ratio H/D increases and air, gasoline , and water superficial velocity increases. As well as the expansion of the bed increases as air, gasoline, and water superficial velocity increases.

في هذا البحث تمت دراسة خواص أنبوب التمييع رباعي الطور (نسبة ارتفاع الماده الصلبه / قطر الانبوب (H/D), سرعه الهواء والماء والكازولين) من خلال بناء أنبوب تمييع رباعي الطور عمليا و بناء نموذج نظريا. الأنبوب المستخدم عمليا من مادة (Perspex) بطول 1م وقطر 0.0254 م. تم أنشاء نموذج نظري ثنائي الأبعاد باستخدام برنامج (Ansys fluent 15.0). كذألك تم إيجاد معادلة تجريبيه لحساب فرق الضغط للأنبوب بالاعتماد على خواص الأنبوب وبنسبة حيود 22 %. الاطوار المستخدمه هي الهواء والماء والكازولين والحبيبات الصلبه. بينت النتائج بان ضغط الأنبوب يزداد بزيادة النسبة (H/D) وسرعة الهواء والكازولين والماء. بالإضافة إلى ذلك فان ارتفاع المادة الصلبة داخل الأنبوب يزداد بزيادة سرعة الهواء والكازولين والماء.


Article
TRANSIENT THERMAL BEHAVIOR OF FLUIDIZED BED COLUMN

Author: Dr. Riyadh S. Al-Turaihi
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2012 Volume: 12 Issue: 1 Pages: 23-37
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The effect of the particle size (dp) and the fluidized velocity investigated Experimentally andtheoretically for different values of heat flux thermal behavior in gas-solid fluidized bed was donewith time. In this work three different particle size was employed (450,650 and 850mµ ). The fluidizingagent was air at different velocities in the range of (2-2.8 m/s). The rig provided with a horizontal heating tube with outer diameter of (3.175cm) was heated eclectically with different power supplies(80,240,350 Watt). Presented mathematical model one dimensional unsteady includes energy, continuity, andmomentum equations for each of two phases. In order to solve the foregoing equations in anumerical way, the discretization method based on control volume procedure has been used thecomputer code (FLBD) which is written with mathlab 2008. The results show that the temperature distribution along the packing height decreases withincrease particle size and the heat flux represents as the temperature increases as the air velocitiesincrease with time. Compared the experimental and theoretical results and the comparison is a goodagreement.

يتضمن البحث دراسة عملية ونظرية لتأثير كل من حجم الجسيمات الصلبة , وسرعة الجريان وكمية الحرارة المنتقلة على توزيع درجات الحرارة في الجريان ثنائي الطور (غاز - صلب) مع الزمن . لقد تم استخدام الرمل كمادة صلبة وبثلاثة اقطار مختلفة


Article
Experimental Investigation of Two-Phase GAS-Liquid Slug Flow Inclined Pipe

Authors: ESAM M. ABED --- RIYADH S. AL-TURAIHI
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2013 Volume: 21 Issue: 5 Pages: 1579-1591
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The experimental results of flow pattern and pressure drop of gas–liquid flow in inclined pipe are presented. The diameter of test section is 50 mm, and overall length of 4 m. The inclination angle of the test section is 30o. Air and water are used as working fluids. The gas superficial velocity and liquid superficial velocity are varied in a range of (1.358142-5.432568) m/s and (0.169764-1.527884) m/s, respectively. The pressure drop along the test section of the pipe is also measured. The characterization of flow patterns is achieved via visual observations and by analysis of local pressure measurements. The observed flow patterns are presented in terms of flow pattern maps for pipe inclination. The slug two-phase flow patterns are observed in the experiments. A video camera recording and pressure transducer sensor with interface are used to study flow regimes and pressure drop through test section. The following flow regimes, depending on the superficial liquid and gas velocities are observed. The flow regime and pressure fluctuating across pipe depending on superficial liquid and gas velocities. It noted that the pressure decreases with distance along pipe when gas superficial velocity increased and also increased liquid superficial velocity.

الغرض من البحث هو دراسة الجريان ثنائي الطور لنبوب بقطر 50 ملم و طول 4 متر و يميل بزاوية 30 درجة عن لأفق.هبوط الضغط على طول مقطع الاختبار تم قياسه. تم استخدام الهواء و الماء كمائع تشغيل. تم استخدام سرعة هواء و ماء مختلفة وبمعدل (1.358142-5.432568) م/ث و (0.169764-1.527884) م/ث على التوالي. تم ملاحظة الجريان نوع (slug) أثناء التجارب. تم استخدام كاميرة فيديو لتحليل الصور و كذلك استخدام متحسسات ضغط مثبتة على الأنبوب في 4 مواقع .تم الاستنتاج أن شكل الجريان يعتمد على سرعة الهواء و الماء وكذلك لوحظ أن الضغط يتناقص مع طول الأنبوب عند زيادة سرعة الهواء والماء.


Article
EXPERIMENTAL STUDY AND CFD SIMULATION OF TWO - PHASE FLOW (WATER – SOLID) IN FLUIDIZED BED COLUMN
دراسة عملية ومحاكاة لأبراج التمييع ثنائية الطور ( ماء- صلب)

Author: Dr. Riyadh S. Al-Turaihi Sarah Hassan Oleiwi
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2016 Volume: 16 Issue: 3 Pages: 297-314
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The static pressure of two phase ( liquid - Solid ) fluidized bed was investigated experimentally in this work for different values of the ratio static bed height over the diameter of the bed column (H/D) (0.59, 0.98, 1.38) and liquid phase velocity (0.16, 0.49, 0.82 m/s). As well as the expansion of the bed visualized experimentally has compared with the solid volume fraction found numerically. The fluidized system consists of glass test pipe of 1m height and 0.0254 m diameter inserted with stainless steel particles of 1.5 mm diameter fluidized by water. Pressure was measured by pressure sensor located at four tapes on the side of the fluidized bed pipe. High speed camera was used to photograph the flow in the test pipe. The experimental results compared with computational fluid dynamics model simulated by ANSYS FLUENT version 15.0. The results were in a good agreement with the experimental data.

تم دراسة الضغط في أبراج التمييع ثنائية الطور (سائل - صلب) عمليا في هذا البحث لكميات مختلفة من نسبة ارتفاع المادة الصلبة إلى قطر الأنبوب المستخدم للتمييع (H/D) (0.59, 0.98, 1.38) و سرعه الطور السائل (0.16, 0.49, 0.82 m/s). كذلك تمت مشاهده ارتفاع المادة الصلبة داخل الانبوب عمليا ومقارنتها مع النتائج النظرية للكسر الحجمي للمادة الصلب. النظام المستخدم للتمييع يتكون من انبوب شفاف بارتفاع ام و قطر 0.0254 م وبداخله حبيبات من مادة الفولاذ المقاوم للصدأ بقطر 1.5ملم والتي تم تمييعها باستخدام الماء. تم استخدام أربع متحسسات لقياس الضغط على طول انبوب التمييع. استخدمت كاميرا تصوير ذات سرعه عالية لتصوير الجريان داخل الأنبوب. تمت مقارنة النتائج العملية مع نتائج الموديل الرياضي ووجدت في حالة تطابق جيد ..


Article
Performance Assessment of LiBr-H2O Absorption Chiller for Air Conditioning Purposes
تقييم أداء مثلج ماء امتصاصي يعمل بمحلول )ماء + بروميد الليثيوم (لأغراض تكييف الهواء

Authors: Qusay Rasheed Al-Amir --- Hameed Kadhem Hamzah --- Riyadh S.Al-turaihi
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2017 Volume: 15 Issue: 3 Pages: 160-173
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The thermodynamic analysis of a 4TR single stage absorption chiller is executed numerically using Engineering Equation Solver (EES) software. In this chiller, water and lithium bromide mixture is used as a working fluid and supplies by hot water from electrical boiler at any temperature. The investigation is done to assess the effect of varying the exit temperatures of the absorber, evaporator, generator, and condenser on the absorption chiller cycle performance. The cycle simulation is based on the operating temperature ranges and fixed parameters which include as follows: evaporating exit temperature within a range of 2-11 °C, generator exit temperature within a range of 80-89°C, condenser exit temperature range from 30 to 48°C, absorber exit temperature range from 20 to 38°C, three magnitudes of effectiveness of heat exchanger (0.6, 0.65 and 0.7), strong solution flow rate 0.05 kg/s. The results depicted that the performance parameters are affected by the operation temperatures of main components and heat exchanger effectiveness

تم اجراء دراسة عددية ببرنامج EES على مثلج ماء امتصاصي بسعة تتراوح 4 طن تثليجي . هذا المثلج يعمل بمحلول ماء و بروميد الليثيوم كمائع تشغيلي ويجهز بالمائع الحار عن طريق غلاية كهربائية. الهدف من هذا البحث, دراسة تاثير تغير درجات الحرارة الخارجة من الماص و المبخر و المولد والمكثف على أداء مثلج الماء. المحاكاة العددية تمت عند معدلات درجات حرارية مختلفة وكانت كالآتي: درجات الحرارة الخارجة من المبخر بين 2 و11°م, درجات الحرارة الخارجة من المولد بين 80 و89°م , درجات الحرارة الخارجة من المكثف بين 30 و 48°م و درجات الحرارة الخارجة من الماص بين 20 و38°م. كذلك تم دراسة تأثير تغير قيم فعالية المبادل الحراري على أداء المثلج وكانت على التوالي 0,6 و 0,65 و0,7. النتائج المستحصلة بينت ان أداء المثلج يتأثر بتغير درجات الحرارة التشغيلية للمكونات الأساسية للنظام بالإضافة الى تأثره مع تغير قيم فعالية المبادل الحراري.


Article
EXPERIMENTAL STUDY OF TWO-PHASE FLOW AROUND HYDROFOIL IN OPEN CHANNEL
دراسة عملية للجريان ثنائي الطور حول جنيح في قناة مفتوحة

Loading...
Loading...
Abstract

The purpose of this paper is to study the two-phase flow around hydrofoil. Experimental studies have been conducted in a channel with air-water flow for different angles of hydrofoil with different air and water discharges. The paper describes experiments carried out in the channel with the rectangular test section of 100 x 30 x 800 mm. The maximum inlet velocity at the test section for air is 1.115 m/s and for water is 0.022 m/s. These experiments have been aimed to visualize the two phase flow phenomena as well as to studies effect of pressure difference through channel with hydrofoil. All sets of flow data in this study were obtained using pressure transducer and visualization by video camera and recorded at multiple angles of attack (0o,15o and 25o) and different Water discharge (l/min) (20, 25, 35 and 45) and different air discharge (l/min) (10, 20, 30 and 40). When (α=0°) the flow is parallel to the hydrofoil surface and there is no vortex shedding behind the hydrofoil. When (α=15°) the flow separates from the upper-surface and the separation point moves towards the leading edge of the hydrofoil as the air water discharges increases. When the angle of hydrofoil (α=25°), the flow separates near the leading edge of the upper surface and large eddies are shed from both the upper and lower surfaces. For constant water discharge, the pressure difference increased with increased air discharge with the same angle of hydrofoil

الغرض من البحث هو دراسة الجريان ثنائي الطور حول جناح. تم إجراء دراسة عملية و بناء منظومة للجريان ثنائي الطور باستخدام قناة شفافة وتم وضع الجنح داخل القناة. وتم إجراء الاختبارات لعدة زوايا ميلان للجنح و لعدة معدلات جريان للماء والهواء. تم وصف التجارب المختبرية باستخدام نموذج اختبار بأبعاد (100 x 30 x 800) ملم و باستخدام أقصى سرعة جريان للهواء بمعدل 1.115 م/ثا و سرعة ماء 0.022 م/ثا. النتائج العملية تم أخذها عند عدة زوايا هجوم (α = 0°, 15° and 25°) و باستخداممعدلات جريان مختلفة للماء (20, 25, 35 and 45) لتر/دقيقة و للهواء (10, 20, 30 and 40) لتر/ دقيقة. يهدف الجزء العملي لدراسة الجريان ثنائي الطور على جنح و دراسة ظاهرة الجريان الثنائي التي تحصل عند الجريان و دراسة الاختلاف بالضغط عند مدخل و مخرج القناة بوجود الجناح و باستخدام التصوير الفديوي و كذلك حساب الضغط عند مدخل و مخرج القناة. تم الحصول على نتائج عملية و هي بزيادة زاوية الهجوم فان الجريان سوف ينفصل في النهاية الامامية لسطح الريشة المواجهة له مع تولد و دوامات كبيرة تنفصل من السطح العلوي و السفلي للريشة. كذلك لوحظ انه عند ثبوت كمية الماء يزداد الضغط مع زيادة كمية الهواء المجهزة عند ثبوت زاوية الهجوم .

Keywords

Two-Phase --- Hydrofoil --- Channel --- pressure drop


Article
Heat Transfer Enhancement in Vertical Channel for Two Phase Flow by using Compound Turbulater

Authors: Riyadh S.Al.Turaihi --- Mohammed W.Al-Jibory --- Hind Naji Al-Jibory
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 1 Pages: 60-71
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The mixture of air-water (gas-water) flow has many applications in chemical and mechanical industries and heating systems (heat exchangers and manifolds), fields of energy, petroleum, refrigeration, and air conditioning. The characteristics of the mixture (water, air) have been investigated experimentally in a rectangular channel placed vertically by using internal heated plate (compound turbulater ribs and groove) with different volume flow rates of water and air, and constant heat flux. The dimensions of the rectangular channel are (5 × 3 × 70 cm). The aim of these experiments is to display the two-phase flow phenomenon with heated plate (three compound turbulater) for different water and air discharges. Four different values of water flow rate (3, 6, 9, and 12 l/min), three different values of air flow rate (8.33, 16.67, and 25 l/m), and three different values of heat power (109.65, 150, and 235 watts) have been used. The temperature of the mixture has been measured at several locations along the channel, and the behavior for the mixture inside the channel has been visualized by using video camera. The results showed that when water and air flow rate increases, flow becomes turbulent, vortices develops around the heated plate, the exit temperature decreases and local heat transfer coefficient increases. The compound turbulater with relative groove position (g/p)=0.55 had a higher rate of heat transfer ,where the percentage difference from other model (g/p = 0.73 and 0.37) were 4% and 6% , respectively due to the fact that the flow mixing and sweeping surface in these types of compound turbulater are more than others type.

الخليط من تدفق الماء والهواء (غاز – ماء) له العديد من التطبيقات في الصناعات الميكانيكية والكيمياوية و انظمة التسخين (المبادلات الحراريه والفتحات ),مجال الطاقة ,النفط,التبريد والتكيف.خصائص هذا الخليط (ماء – هواء) تم التحقق منه عمليا داخل قناة مستطيلة وضعت عموديا بواسطة استخدام لوحة مسخنة (معرقل مركب من الاضلاع وتجويف ) مع معدلات تدفق حجمية مختلفة من الماء والهواء وبثبوت الحرارة على وحدة المساحة .ابعاد القناة المستطيلة (5×3×70 سم) .الهدف من هذه التجارب هو لبيان ظاهرة الجريان ثنائي الطور بوجود لوحة المسخنة (المعرقل المركب بثلاث اشكال ) ولمختلف معدلات التدفق من الماء والهواء .اربع قيم مختلفة لتدفق الماء (3,6,9,و12)لتر/دقيقة,ثلاث قيم مختلفة لتدفق الهواء (8.33,16.67,و 25)لتر / دقيقة,و ثلاث قيم مختلفة من الطاقة الحرارية (109.65,150,و 235 واط) تم استخدامها.درجة حرارة الخليط تم قياسها في مواقع متعددة على طول القناة,و وتم تصور سلوك الخليط داخل القناة باستخدام كاميرا الفيديو.اظهرت النتائج بانه عند زيادة تدفق الماء والهواء الجريان يصبح مضطربا,وتتكون الدوامات حول اللوحة المسخنه ,درجة حرارة الخروج تقل ومعامل انتقال الحرارة سوف يزداد. المعرقل المركب مع موقع نسبي للتجويف = 0.55 له معدل اكبر في انتقال الحرارة , حيث ان النسبة المئوية للفرق عن الانواع الاخرى ( g/p = 0.73 و 0.37) كانت 4% و 6% بالتعاقب ويرجع ذلك إلى حقيقة أن الخلط والسطح الكاسح في هذه الأنواع من مثيرات الاضطراب المركبة هي أكثر من الانواع الاخرى.


Article
ENHANCEMENT THE HEAT TRANSFER FOR TWO-PHASE FLOW THROUGH A RECTANGULAR RIBBED VERTICAL CHANNEL
تحسين انتقال الحرارة لجريان ثنائي الطور خلال قناة مستطيلة عمودية مضلعة

Loading...
Loading...
Abstract

The heat transfer coefficient and temperature distribution of two phase flow (water, air) in rectangular ribbed vertical channel was investigated experimentally and numerically in this work for different values of water and air superficial velocities (0.0421, 0.0842, 0.1158, 0.1474 and 0.1684 m/s) and (1.0964, 1.425, 1.644, 1.864 and 2.193 m/s), respectively, at constant heat flux (120 W). The distribution of temperature along the channel was photographed using thermal camera and compared with images for the corresponding contours which found numerically. The experimental results of heat transfer coefficient compared with computational fluid dynamics model simulated by Ansys fluent 15.0. A good agreement has been found between the experimental and numerical data, where the percentage deviation between the experimental and the numerical results is (1% - 6% ). The results showed that, the local heat transfer coefficient increased by adding ribs, it also increased as the velocity of the flow increased.

يتضمن هذا العمل دراسة عملية و نظرية لتوزيع معامل انتقال الحرارة ودرجات الحرارة لجريان ثنائي الطور (ماء – هواء) في قناة عمودية مضلعة مستطيلة لقيم سرع متعددة للماء و الهواء عند فيض حراري ثابت(120 واط). تم تصوير توزيع درجة الحرارة على طول القناة باستخدام كاميرا حرارية وتم مقارنتها مع النتائج النظرية. تمت مقارنة النتائج العملية لمعامل انتقال الحرارة مع النتائج النظرية باستخدام برنامج) انسز-فلونت نسخة 15.0 .( تم ايجاد توافق جيد بين النتائج العملية والنظرية لمعامل انتقال الحرارة مع نسبة تفاوت تتراوح بين (6-1%).اظهرت النتائج ان معامل انتقال الحرارة يزداد عند اضافة العوائق ,وكذلك يزداد عند زيادة سرعة الجريان.

Listing 1 - 9 of 9
Sort by
Narrow your search

Resource type

article (9)


Language

English (9)


Year
From To Submit

2018 (2)

2017 (2)

2016 (2)

2013 (2)

2012 (1)