research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Study of Failure of the Steam Tubes of Boiler Furnaces in Najebia Power Plant
دراسة فشل انابيب البخار لأفران المراجل في محطة النجيبية الحرارية

Authors: Haider M. Mohammed --- Saleh E. Najim
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2011 Volume: 11 Issue: 1 Pages: 72-81
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Failures in the steam tubes of boiler furnaces in Najebia power plant was studied experimentally. Visual examination, mechanical tests, microscopic test and chemical analyses were performed. Visual examination showed the types of failure in the tubes. Tensile and hardness tests were performed to estimate the variation in the mechanical properties of the tubes metal and compared with the new tubes. Microscopic test for the failed tubes used to recognize the difference in the microstructure to the metal of the tubes. Chemical analyses involved chemical composition of the tubes metal, river and feed water analyses, water treatment, fuel analyses and analysis of deposits and oxides on the external and internal sides. Overheating and wall thinning of the tubes resulted from oxygen escaping to the inner side of these tubes, and presence of deposits and oxides on the external and internal sides which led to failure was studied extensively. Engineering remedies were also given to confine the problem and to prevent it in future.

Keywords


Article
Effect of Operating Conditions on Co2 Absorption into Aqueous Alkanol amine Solutions in Packed Column
تأثیر الظروف التشغیلیة على عملیة امتصاص غاز ثاني أوكسید الكربون باستخدام المحالیل الأمینیة خلال الأبراج المحشوة

Authors: Adnan A. Ateik --- Saleh E. Najim --- C. K. Haweel
Journal: University of Thi-Qar Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 26645564/26645572 Year: 2011 Volume: 2 Issue: 1 Pages: 103-117
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

This paper highlights the importance of operating parameters to mass-transfer in CO2 absorption in columns with different packings. The study compares the performance of two packings, Gempak 4A and Raschig ring. Mass-transfer efficiency of these packings was determined by carrying out absorption experiments in a pilot-scale absorption unit with aqueous solutions of monoethanolamine (MEA), Diethanolamine (DEA),2-amino-2-methyl-1-propanol (AMP) and methyldiethanolamine (MDEA) as test solvent.The overall mass-transfer coefficient (KGav) can be considered to be indicative of the CO2 removal efficiency of the system and can be calculated from experimentally gas-phase CO2 concentration profiles within the test columns. The results of this study indicate that masstransfer coefficient of these packings tested varies significantly not only with operating parameters such as liquid load, liquid CO2 loading, solvent concentration, solvent type and feed CO2 concentration but also with packing arrangement.In absorption experiments the results show the typical behavior of liquid controlling system. Gas flow rate has no influence on overall mass transfer coefficient (KGav), and an increase in liquid flow rate yields a greater (KGav). CO2 loading lowers the (KGav) and anincrease in amine concentration induces a higher (KGav). Increasing the CO2 concentration within the feed gas was found to reduce the value of (KGav) within the system.Structured packing offers superior performance to random packings, structured packing provides almost twice greater (KGav) than random packings.

یسلط ھذا البحث الضوء على الاحداثیات المھمة في عملیات انتقال المادة عن طریق امتصاص غاز ثاني اوكسید الكربون في الابراج المحشوة كما یھدف البحث الى المقارنة بین الحشوات المنتظمة والحشوات العشوائیة للأبراج. تم بحثكفاءة انتقال المادة بأجراء تجارب عملیة في وحدة امتصاص ریادیة باستعمال محالیل أمینیة مختلفة ولكلا النوعین من الحشوات.أن معامل انتقال المادة الاجمالي یمكن ان یعد دلیل على كفاءة ازالة غاز ثاني اوكسید الكربون الذي یحسب من خلال التجارب العملیة باتباع تدرج التركیز لغاز ثاني اوكسید الكربون في جزء البرج المعد لذلك. دلت النتائج على ان معامل انتقال المادة یتغایر لیس فقط مع احداثیات التشغیل ( تركیز المذیب ونوعھ، تركیز غاز ثاني أوكسید الكربون في السائل والغاز الداخل ومعدل جریان السائل) ولكن أیضاً مع ترتیب الحشوات. تبین أن طور السائل ھو المسیطر على عملیة الامتصاص وأن معدل جریان الغاز لیس لھتأثیر على معامل انتقال المادة الاجمالي بینما ینتج زیادة معدل جریتان السائل وتركیزه زیادة في معامل انتقال المادة الاجمالي وان زیادة تركیز غاز ثاني اوكسید الكربون في الغاز الداخل یؤدي الى تقلیل معامل انتقال المادة الاجمالي. أن الحشوات المرتبة بانتظام تعطي اداء افضل بالمقارنة مع الحشوات العشوائیة حیثوجد ان ھذا الترتیب للحشوات یعطي تقریبا" ضعف قیمة معامل انتقال المادة الاجمالي بالمقارنة مع الحشوات العشوائیة.


Article
Experimental Study of Thermal Bubble Pump

Authors: Safaa H. Faisal --- Abdulwadood S. Shihab --- Saleh E. Najim
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2014 Volume: 14 Issue: 2 Pages: 77-90
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

In this study, a numerical investigation hasbeen carried out for single phase flow behavior for thirty sixinternally finned tubes to demonstrate the effect of axial pitchto fin height ratio (p/e) for 0.8≤p/e≤6.345, helix angle ofinternal fins (β) for 30°≤β≤70°, apex angle of internal fins (α)for 0°≤α≤53.13°, internal fin height (e) for 0.6mm≤e≤1.0mm,internal tube diameter (di) with 14 mm and Reynolds number(Re) of single phase flow for 10000≤Re≤50000 on enhancementof forced convection heat transfer and reduction of frictionfactor by using ANSYS CFX program. It solves the threedimensionalNavier-Stokes equations for steady state turbulentwith SST model and enhance wall treatment. The numericalanalysis provided at fully developed velocity and temperature.Numerical results showed that the smallest axial pitch to finheight ratio (p/e) =0.8 and with apex angle α=10 degreeprovided enhancement of heat transfer of 2.8 to 3.55 timeshigher than of smooth tube. Finally, present numerical resultsare seen to be in good agreement with literature experimentalcorrelations.


Article
Numerical Modeling for Novel Solar Air Heater Utilizing Wax Paraffin-PCM

Authors: Jalal M. Jalil --- Saleh E. Najim --- Salah M. Salih
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2019 Volume: 19 Issue: 2 Pages: 1-8
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

A mathematical model to analysis three–dimensional forced convection turbulent flow in a novel solar air heater integrated with multiple rectangular capsules filled by paraffin wax-based on phase change material PCM was implemented. The investigations were performed under three airflow speed of (0.6, 1.2, and 1.8) kg/min and average solar flux of 625 W/m2. The results revealed that the delaying melting time and also lower the melting temperature of PCM by increasing airflow speed during the charging process. As well as, the freezing period is dependent on the airflow speed by inverse relation. Also, the data results represent that the useful energy rate and thermal storage efficiency were a strong dependence on the airflow speed. Moreover, it can be detected that the optimal freezing time and the air temperature rise of the heater were reached about 210 minutes with (12 – 1.5 °C), 150 minutes with (7.5 – 1.4°C), and 120 minutes with (5.5 – 1.5 °C), at airflow speed of 0.6, 1.2, and 1.8 kg/min, respectively, which can be used at night to supply some applications by thermal energy such as heating buildings and drying agricultural crops.


Article
SIMULATION SOLAR ELECTRICAL GENERATION POWER PLANT BY USING PARABOLIC TROUGH IN BASRA CITY
محاكاةُ محطة توليد الطاقة الكهربائية باستخدام المجمعات الشمسية ذات القطع المكافئ الوعائي في مدينةِ البصرة

Loading...
Loading...
Abstract

ABSTRACT A simulation for a solar thermal electric generating system with parabolic trough collectors in Basra city is presented. This system consists of three parts: solar collector fields to heating the working fluid, a storage system to store the thermal energy, and power conversion system to convert the thermal energy to electrical. The simulation is presented for all parts. The energy conversion of solar radiation into thermal power along the absorber tube of the parabolic collector is studied. The coupling between the collector and the thermodynamic cycle is made up by heat exchangers, yielding the characteristic temperatures of the cycle. The conventional Rankine cycle is used as the thermodynamic cycle, whereby the electric power is calculated. All calculations are performed according to Basra climate’s conditions for 21st of each month in 2007.Engineering Equation solver (EES) software is used in this simulation. Good agreements are obtained when comparing the results of the collector outlet temperatures and gross power of the current model with experimental data belonging to the Solar Electric Generating Systems (SEGS) installed in the Mojave Desert in southern California, whose solar field is composed by parabolic trough collectors. The analytical model developed combines precision and flexibility, making it an attractive tool for simulation and design of solar power stations in Basra city.

الخلاصةيقدّمُ هذا البحث محاكاة لمنظومة توليد طاقة كهربائيةِ حراريِة شمسيِة تستخدم المجمعات الشمسية ذات القطعّ المكافئ الوعائي (parabolic trough) في مدينةِ البصرة. تَشْملُ هذه المنظومةِ ثلاثة أجزاءِ: المجمعِ الشمسي المستخدم لتَسْخين المائع الناقل للحرارةَ و منظومة لخزنِ الطاقةَ الحراريةَ ومنظومة تحويل الطاقة الحرارية إلى طاقة كهربائيةِ، تم عَمل المحاكاة لهذه الأجزاء الثلاثة. وقد تمت دراسة تحويلَ طاقةَ الإشعاعِ الشمسيِ إلى الطاقة الحراريةِ على طول الأنبوب الماصَ للمجمعِ الشمسي ذي القطع المكافئ الوعائي. إنّ الربط بين المجمعِ الشمسي والدورة الثرموديناميكية للمحطة (thermodynamic cycle) تم بواسطة المبادّلات الحراريةِ، للحصول على درجاتَ الحرارة المناسبة لعمل الدورةِ. وقد فَرض أن منظومة تحويل الطاقة مكونة من محطة بخارية كهربائية تعمل بدورة رانكن التقليدية (conventional Rankine cycle)، حيث تم حساب الطاقة الكهربائية لهذه المحطة. لعمل المحاكاة لهذه المحطة أُختيرَ يوم (21) من كل شهر لعام 2007 وافترض انه يوم صحو وخالي من الغيوم. كما تم تصميم وتحليل هذه المحطة وفقا لظروف مناخ مدينة البصرة. لعمل المحاكاة استعملت برمجيات Engineering Equation Solver (EES) . أوضحت المقارنة بين نَتائِجَ النموذجِ الحالي مع النَتائِجَ التجريبيةِ التي تَعُودُ إلى أنظمةِ توليد الطاقة الكهربائيةِ الشمسيةِ الموجودة في صحراءِ موييف في جنوب كاليفورنيا، التي يتكون حقلها الشمسي مِن مجمعات شمسية ذات القطعّ المكافىءِ الوعائي، توافقا كبيرا. أن الدقّةِ والمرونةِ للنتائج ِ التحليليةِ النموذجيةِ المتطورةِ التي تم الحصول عليها، تجعلها أداة جذّابة للمحاكاةِ وتشجع على تصميمِ محطاتِ الطاقة الكهربائية الشمسيةِ في مدينةِ البصرة.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (5)


Year
From To Submit

2019 (1)

2014 (2)

2011 (2)