research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
The Impact of Using heat Insulation in Reducing Operational Energy and LCA Emission in Local Building
أثر اضافة العازل الحراري في تخفيض طاقة التشغيل وحجم الانبعاثات الملوثة في المباني المحلية

Authors: Mohammad Salman Dawood محمد سلمان داود --- Younis Mahmoud M.Saleem يونس محمود محمد سليم
Journal: Iraqi Journal of Architecture & Planning المجلة العراقية لهندسة العمارة والتخطيط ISSN: 26179547 / 26179555 Year: 2017 Volume: 13 Issue: 4 Pages: 54-67
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The Building sector is one of the biggest sector in energy consumption and greenhouse gases emission, and the biggest phase of building life cycle that responsible of that consumption of energy and emission is operation phase (specially Heating and cooling) and it’s effected directly by building material thermal conductivity. There is a different ways to reduce operation consumption of energy and life cycle emission like using insulated wall and glazing. So the research problem will be “the need of applied research that compare the energy consumption of energy and emissions change in masonry building when using different thermal performance skins”. So the goal of the research is “measure and compare Building energy consumption in operation phase and emissions in life cycle of Masonry Building”.The conclusion of this research is that the possibility to reduce energy used in building to 44.8% and reducing emission to 56.4% using cavity wall and insulation in Masonry Building. Assessed by Life Cycle Assessment method.

يشكل قطاع العمارة احد اكبر القطاعات في استهلاك الطاقة و انبعاثات الغازات الملوثة و يكون الجزء الاكبر من استهلاك الطاقة و طرح الانبعاثات في مرحلة تشغيل المبنى. وتشكل طاقة التكييف الجزء الاكبر من طاقة التشغيل الكلية للمبنى. التي تتعلق بشكل مباشر بالخصائص الحرارية لمواد الانشاء و التي يمكن تحسينها من خلال استعمال مواد ذات كفاءة في العزل الحراري لقشرة المبنى.برزت المشكلة البحثية بـ " الحاجة لوجود بحوث علمية تطبيقية تقارن بين نسبة الانبعاثات الملوثة للبيئة ، و استهلاك الطاقة في المباني المحلية المبنية بالطابوق، عند تغيير خصائص العزل الحراري لمكونات غلافها الخارجي", ولذا اصبح هدف البحث "تقييم اثر تغيير سمك ونوع مكونات قشرة المبنى عند البناء بالطابوق في تقليل حجم الانبعاثات الملوثة و استهلاك الطاقة" . بالتالي تقليل الاثار السلبية على بيئة الارض.تتضمن خطة البحث تقييم مقدار التخفيض في استخدام طاقة التشغيل، و انبعاثات الغازات في المباني بأستعمال نظام تقييم معتمد من المنظمة الدولية للمعايير الايزو (ISO)، بأسم نظام تقييم دورة الحياة (LCA) فعند تغيير معامل العزل لقشرة المبنى تتغير قيم طاقة التشغيل للمبنى، و الانبعاثات الناتجة عنها. حيث توصل البحث لنتائج تخفيض طاقة التشغيل لتصل لـ 44.8% من الطاقة للمبنى المحلي و تخفيض الانبعاثات لـ 56.4% من انبعاثات المبنى المحلي عند البناء بالجدار المجوف و العازل الحراري.


Article
Employing natural lighting systems technology in raising environmental efficiency in educational buildings
توظيف تكنولوجيا انظمة الأنابيب الضوئية في رفع الكفاءة البيئية في الأبنية التعليمية

Authors: Saif Aldeen Saad Abdul-Hameed سيف الدين سعد عبد الحميد --- Younis Mahmoud M.Saleem يونس محمود محمد سليم
Journal: Iraqi Journal of Architecture & Planning المجلة العراقية لهندسة العمارة والتخطيط ISSN: 26179547 / 26179555 Year: 2017 Volume: 13 Issue: 3 Pages: 41-54
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Studies were carried out to increase dependence on day lighting to illuminate the buildings because of their psychological and health benefits ,and recent research has shown that exposure to artificial lighting for long periods cause health damage. As a result, many modern and sophisticated systems has emerged to introduce day lighting into the building to integrate with the traditional system (windows). These systems are based on advanced technology and can be available at relatively low cost, especially light tubes that integrated with traditional lighting (windows) to light deep spaces. Hence this research introduces new methodology added by using one of the modern lighting systems (light tubes) in the design process of buildings, and achieve coherence and efficiency in lighting levels inside the deep spaces by combining traditional and modern system, using computer. Hence the research problem consists in the lack of local studies that link traditional systems (Windows) and modern systems, particularly light tubes to light up the deep spaces. The goal of the research, is to integrate traditional systems (Windows) and modern systems, (light tubes), within a unified practical framework to employ light tubes locally in buildings. So this paper first dealt with day lighting technology systems and then chose the (light tubes) for its high efficiency, and distinctive characteristics apart from being inexpensive. Then the study adopted the rate of uniformity concluded from the application practical side to determine lighting levels and the efficiency of the merger between the two systems down to the final conclusions of the framework and the imposition of hypotheses.

يجري العمل بجدية لتقليل الاعتماد على الاضاءة الصناعية و استغلال الاضاءة الطبيعية لإضاءة المبنى لما لها من فوائد صحية و نفسية . وقد اثبتت الأبحاث الحديثة أن التعرض للإضاءة الصناعية لفترات طويلة يتسبب في أضرار صحية كثيرة. و نتيجة لذلك و للحاجة الى ضوء النهار داخل البناية بشكل يحقق الراحة للمستخدم ظهرت انظمه حديثة و متطورة كثيرة لادخال الاضاءة الطبيعية الى داخل المبنى لتتكامل في عملها مع الأنظمة التقليدية. ومن هنا تبرز المشكلة البحثية المتمثلة في غياب الدراسات المحلية التي تربط بين الانظمة التقليدية (الشبابيك) والانظمة الحديثة ، وخاصة الانابيب الضوئية، لاضاءة الفضاءات العميقة. يتم ذلك من خلال تحقيق التجانس و الكفاءة في مستويات الاضاءة داخل الفضاءات العميقة وتوفير ظروف بيئية ملائمة تسهم بدورها في الشعور بالراحة النفسية. بالتالي التوصل الى هدف البحث وهو التكامل بين توظيف الانظمة الاعتيادية (الشبابيك) والانظمة الحديثة (الانابيب الضوئية) لأنارة الفضاءات الداخلية في الأبنية محليا. لتحقيق هدف البحث اجرى البحث دراسة شملت نماذج افتراضية تم من خلالها اعتماد مستويات تجانس معينة في التطبيق العملي تقود الى تحديد مستويات الاضاءة وكفاءة الدمج بين النظامين في تصميم القاعات الدراسية للأبنية التعليمية. وتوصل البحث الى الاستنتاجات النهائية بتحديد علاقة معيارية بين عدد الأنابيب الضوئية المستخدمة واقطارها نسبة الى مساحة الشبابيك المستخدمة ولتوجيهات مختلفة ضمن ظروف الواقع المحلي، هذه العلاقة ستكون دليل للمصمم في توفير مستويات إضاءة كفوءة تحقق التجانس المطلوب داخل الفضاء بإستخدام الأنابيب الضوئية عند تصميم الابنية التعليمية.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (2)


Year
From To Submit

2017 (2)