Mixed Convection from Electronic Equipment Component at Different Position at Enclosure by Primitive Variables Method

Authors: Sattar J. Habeeb --- khalid A. Ismael --- Jalal M. Jalil
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2006 Volume: 12 Issue: 1 Pages: 37-52
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A numerical study of mixed convection cooling of heat dissipating electronic component, located in a rectangular enclosure, and cooled by an external through flow of air is carried out. A conjugate problem is solved by primitive variables method, describing the flow and thermal fields in air. The interaction between the components is of interest here, depending on their relative placement in the enclosure, and different configuration are considered. For Re=100 laminar, steady flow is predicted for up to Gr/Re2 =25 according to head source location in the enclosure. The mixed convection regime, where the buoyancy effects are comparable to the forced flow, occurs at values of Gr/Re2 between 0.01 and 25 . the results are of values in search for suitable placement of electronic components in an enclosed region for an effective heat removal. In general, it appears that the location of the source on the left vertical wall is the most favorable in terms of cooling. Laminar results are predicted up for up to Gr= 2.5 *105 for all configurations studied.

تم دراسة تشتيت الحرارة الناتجة من أداء الأجهزة الإلكترونية الموضوعة داخل تجويف مستطيل الشكل ، من اجل تبريدها بواسطة هواء خارجي يسلط عليها، مما يؤدي الى الاستفادة من انتقال الحرارة بالحمل المختلط الناتج عن ذلك. حيث تمت الدراسة باستخدام الحل العددي التقريبي لمعادلات الكتلة والزخم والطاقة عن طريق وصف الحركة الديناميكية والحرارية للمائع. أن عملية التداخل الناتجة من وجود اكثر من مصدر حراري داخل الحيز المدروس هي المسألة المهمة هنا، اعتمادا على موقع المصادر الحرارية نسبتا بعضها إلى البعض الأخر داخل التجويف المستطيل الشكل. كما تم أخذ تغير موقع المصادر الحرارية داخل الحيز بنظر الاعتبار،بالنسبة Re=100 ، جريان طباقي، مستقر، إلى رقم ريشاردسون Gr/Re2 بحدود 25 طبقا إلى موقع المصدر الحراري داخل الحيز. في منطقة الحمل المخلط فأن تأثير قوى الطفو قورنت نسبة إلى حالة الحمل القسري والتي تتكون لرقم ريشاردسون بين 25-0.01 . النتائج كانت لقيم البحث عن افضل موقع للمصدر الحراري داخل الحيز عن طريق تأثير إزالة الحرارة. بصورة عامة أتضح أن وضع المصدر الحراري على الجدار العلوي الأيسر للحيز المدروس يعطي أفضل أداة لعملية التبريد وإزالة الحرارة. كما كانت قيم رقم كراشوف بحدود Gr=2.5*105 لكل الحالات المدروسة.


Article
Experimental Investigation of Laminar Mixed Convection in an Inclined Annulus

Authors: Akeel A. Mohammed --- Ihsan Y. Hussain --- khalid A. Ismael
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2006 Volume: 12 Issue: 1 Pages: 181-198
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Experiments were carried out to study the local and average heat transfer by mixed conversation to a simultaneously developing air flow in horizontal, inclined, and vertical concentric cylindrical annulus. The experimental setup consists of an annulus has a radius ratio of 0.555 and inner cylinder with a heated length 1.2m subjected to the constant heat flux while the outer cylinder is subjected to the ambient temperature. The investigation covers Reynolds number range from 154 to 845 , heat flux varied from 96 W/m^2 to 845 W/m^2 , and annulus angles of inclinations α=0◦ (horizontal ) , 40◦ , 70◦ , and 90◦ ( vertical) . Results demonstrate the temperature variation along the inner cylinder surface and the local Nusselt number Nuz variation with the dimensionless axial distance , for all angles of inclinations which shows an increase in the Nuz values as the heat flux increases and as the angle of the inclination moves from the vertical to the horizontal position .

اجريت تجارب عملية لدراسة انتقال الحرارة الموقعي و المعدل بالحمل المختلط لجريان الهواء المشكل تراكبياً ( اي تزامن التشكيل الحراري مع التشكيل الهيدروديناميكي ) بتجويف حلقي بين اسطوانتين متحدي المركز , نسبة نصفة القطر لهما تعادل 0.555 وبطول 1.2 m , وبالوضع الافقي , المائل , والعمودي . سخنت الاسطوانة الداخلية تحت فيض حراري ثابت , بينما عرضت الاسطوانة الخارجية الى درجةحرارة الجو .يتراوح معدل رقم رينولدز Re في هذا البحث من 154 الى 845 أما الفيض الحراري فيتغير من 96 W/m2 الى 860 W/m2 وزوايا ميل التجويف الحلقي هي 0◦ ( افقي ) , 40◦ , 70◦ , 90◦ ( عمودي ) . وضحت النتائج العملية تغير درجة حرارة الاسطوانة الداخلية مع الاتجاه الطولي وكذلك تغير رقم نسلت الموقعي مع المسافة المحورية الغير بعدية , حيث اظهرت النتائج زيادة رقم نسلت مع زيادةة الفيض الحراري ومع انحراف زاوية الميل من الوضع العمودي الى الوضع الاففي .