research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Absorber Diameter Effect on the Thermal Performance of Solar Steam Generator
تاثير قطر الانبوب الماص على الاداء الحراري لمولد بخار شمسي

Authors: Karima Esmael Amori كريمه اسماعيل عموري --- Rand Ahmed Adeeb رند احمد اديب
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 4 Pages: 127-146
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this work, a convex lens concentrating solar collector is designed and manufactured locally by using 10 convex lenses (concentrator) of a diameter 10cm and one Copper absorber tube of a diameter 12.5mm and 1mm in thickness 1m length. Two axes manual Tracking system also constructed to track the sun continuously in two directions. The experiments are made on 17th of May 2015 in climatic conditions of Baghdad. The experimental data are fed to a computer program to solve the thermal performing equation, to find efficiency and actual useful energy. Then this data is used in numerical CFD software for three different absorber diameters (12.5 mm, 18.75 mm and 25 mm). From the results that obtained the maximum thermal efficiency for the collector of diameter 12.5mm equal to 82.3% is higher than that for the collector of 18.75 mm and 25 mm diameter. The maximum outlet temperature is found equal to (105ᵒC, 93.9ᵒC and 83.5ᵒC) for collector absorber diameter equal to (12.5 mm, 18.75mm and 25 mm) respectively. The maximum mass flow rate 0.53 kg/hr when the solar radiation intensity equal to 899 W/m2. The all-day collector efficiency varies with diameter and reaches to maximum value of (77.9%, 61.4% and 52.8) for collector diameter equal to (12.5 mm, 18.75mm and 25 mm) respectively.

في هذا العمل تم تصنيع المركز الشمسي محليا باستخدام ( 10 ) عدسات محدبه, قطر الواحده منها يساوي ( 10 سم) , وانبوب من النحاس قطره ( 12.5 سم) وطوله ( 1 م) وسُمكه ( 1 ملم) كمستلم للاشعاع الشمسي المركزبواسطه العدسات. كما تم استخدام نظام تتبع ثانئي المحور لتتبع الشمس يدويا بصوره مستمره خلال فتره القياس. سُجلت النتائج العمليه في اليوم السابع عشر من شهر نيسان , في الظروف الجويه لمدينة بغداد. تم ادخال القيم العمليه الى الحاسبه بواسطه(CFD software) لحل المعادلات وايجاد الايداء الحراري لاقطار مختلفه للانبوب المستلم تساو ( 25ملم , 18.75 ملم ,12.5 ملم) ,حيث تم حساب كل من الكفاءه, و الطاقه الحقيقه المفيده الكليه. من خلال النتائج تبين ان الكفاءه العظمى للمركز الشمسي ذو نصف القطر الذي يساوي 12.5 ملم تساوي 82.3% حيث كانت اعلى من الكفائه للحالتين ذات القطر الذي يساوي 18.75 ملم وكذلك 25 ملم. سجلت اعلى درجة حراره للماء بمقدار (105ᵒC, 93.9ᵒC, 83.5ᵒC). وكان اعظم معدل لتدفق المائع يساوي 0.53 kg/hr عند اشعاع شمسي مقداره 899 W/m2. وجد ان اعلى معدل للكفاءه الكليه لليوم الواحد تساوي61.4% and 52.8%) , (77.9%,بتغيير القطر للمستلم للشعاع بمقدار ( 25ملم , 18.75 ملم ,12.5 ملم) على التوالي.


Article
Modeling and Simulation of Thermal Performance of Solar-Assisted Air Conditioning System under Iraq Climate
تقييم الاداء الحراري لمنظومة تكييف هواء تعمل بمساعدة الطاقة الشمسية في العراق نظًرياً

Authors: Mohammed Abdulhassan Abid Mohammed Abdulhassan Abid محمد عبدالحسن عبد --- Najim Abid Jassim نجم عبد جاسم
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 8 Pages: 175-194
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of compressor and the performance of system. The results show that refrigeration capacity is increased from 2.7 kW to 4.4kW, as the evaporating temperature increased from 3 to 18 ºC. Also the power consumption is increased from 0.89 kW to 1.08 kW. So the COP of the system is increased from 3.068 to 4.117. The power consumption is increased from 0.897 kW to 1.031 kW as the condensing temperature increased from 35 ºC to 45 ºC. While the COP is decreased from 3.89 to 3.1. The power consumption is decreased from 1.05 kW to 0.7kW as the solar radiation intensity increased from 300 W/m2 to 1000 W/m2, while the COP is increased from 3.15 to 4.8. A comparison between the simulation and available experimental data showed acceptable agreement.

معظم المباني الصغيرة والمتوسطة في العراق تعتمد على انظمة التبريد ذات الضاغط الكهربائي والذي من عيوبه الاستهلاك العالي للطاقة الكهربائية عند حمل الذروة. في هذا العمل تم التحقق نظريا من الاداء الحراري لمنظومة تكييف الهواء المركبة مع مجمع شمسي. يتكون مكيف الهواء الهجين من ضاغط شبه مقفل، مكثف نوع الاسطوانة والانبوب المبرد بالماء، صمام تمدد حراري ومبخر نوع الخزان والملف. شمل التحليل النظري محاكاة لمنظومة تكييف الهواء التي تعمل بمساعدة الطاقة الشمسية باستخدام برنامج EES لتحليل تأثير عوامل مختلفة على استهلاك طاقة الضاغط وأداء المنظومة. بينت النتائج ان سعة التثليج قد زادت من 2,7 الى 4,4 كيلو واط مع زيادة درجة حرارة التبخير من 3 الى 18 درجة مئوية وكذلك فان الطاقة المستهلكة قد زادت من 0.89 الى 1.08 كيلو واط , والذي ادى الى زيادة معامل اداء المنظومة من 3,068 الى4,117. ان الطاقة المستهلكة قد ازدادت من 0,897 الى 1,031 كيلو واط مع زيادة درجة حرارة التكثيف من 35 الى 45 درجة مئوية. بينما معامل الاداء قد انخفض من من 3,89 الى 3,1. ان الطاقة المستهلكة قد انخفضت من 1,05 الى 0,7 كيلو واط عند زيادة الاشعاع الشمسي 300 الى 1000 واطم2, بينما معامل اداء المنظومة قد ازداد من 3,15 الى 4,8. واظهرت المقارنة بين النتائج التجريبية والنظرية اتفاق مقبول بينهما.


Article
Performance Enhancement of an Air Cooled Air Conditioner with Evaporative Water Mist Pre-cooling
تحسين الاداء الحراري لمكيف هواء مكثفه مبرد بالهواء مع تبريد مسبق بمرذاذ مائي تبخيري

Author: Najim Abid Jassim نجم عبد جاسم
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2017 Volume: 23 Issue: 1 Pages: 48-62
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water mist pre cooling; ECAC was compared to the performance of air cooled air conditioner, ACAC which tested under the same ambient condition that is ranged from 25oC to 52oC. Test results show that ECAC operating at EER of 10.5 BTV/W. The ECAC had an EER of 47 % higher than that of ACAC under the same and most serve hot and dry condition of 52oC and 10% relative humidity.

يتعامل البحث الحالي مع التحري التجريبي للاداء الحراري لمكيف هواء نوع منفصل مكثفه مبرد بالهواء مع مرذاذ مائي في عملية تبريد اولي للهواء الخارجي الداخل للمكثف لغرض زيادة السعة التبريدية وخفض الطاقة المستهلكة في جو حار وجاف. يوضح هذا التحقق التجريبي كيف يمكن تحسين الاداء الحراري عند استعمال مرذاذ مائي كمبرد اولي لخفض درجة حرارة الهواء الخارجي قبل الدخول الى المكثف بعملية تبريد اديباتي تعتمد على درجة حرارة البصلة الرطبة للهواء كذلك بموجبها يتم خفض درجة حرارة وضغط التكثيف وفقا لذلك. لذا ستزداد السعة التبريدية وستنخفض الطاقة المستهلاكة وبالتالي ستتحسن نسبة كفاءة الطاقة. تم مقارنة الاداء الحراري لمكيف هواء مكثفه مبرد بالهواء مع مرذاذ مائي مع الاداء الحراري لمكيف الهواء مكثفه مبرد بالهواء ACAC والتي اختبرت في نفس ظروف الجو الخارجي عند درجات حرارة هواء خارجي مداها بين 25 oم و 52 oم. بينت نتائج الاختبار عند الظروف الاساسية بان ECAC تعمل بنسبة كفاءة طاقة EER مقدارها 10.5. ان نسبة كفاءة الطاقة EER لمكيف الهواء ECAC في ظروف جو سائدة حارة وجافة عند درجة حرار 52 oم ورطوبة نسبية 10% اعلى بمقدار 47 % من مكيف الهواء ذو مكثف مبرد بالهواء في نفس الظروف.


Article
Numerical Modelling and Experimental Verification of New Observations of the Two Phases Interaction in a Vertical and Inclined Closed Wickless Heat Pipe

Authors: Alaa A. B. Temimy1 --- Adnan A. Abdulrasool2
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2019 Volume: 27 Issue: 3 Pages: 345-362
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Heat pipes are one of the modern solutions for heat release from hot sources or for heat homogeneity in liquid or solid reservoirs. The interactions between the two phases of its working fluid are suggested classically by researchers and still not discovered deeply. In this study about 480 experimental and numerical tests are carried out to confirm the previous published observation of spatial flow patterns of the two phases inside a wickless copper Thermosyphon Heat Pipe THP partially filled with water. Numerical results are gotten from a three dimensional transient Computational Fluid Dynamics 3DCFD numerical solution. Different factors are included into 3DCFD model to reach reality in results and suffering from complex calculation procedures and increase simulation running time. The high agreement percentages between the experimental and 3DCFD for the temperatures distribution profile and magnitudes confirm the 3DCFD results. 3DCFD solution contours of steam volume fractions SVF show that both phases flow in a 3D spatial, non-steady and non-continues flow streams. Both phases suffering phase change and heat transfer from each to other during flow up (steam) and flow down (condensate). Thermal performance increase about (+ve. (10%)) due to inclination from vertical to 60º then falling to (-ve. (15%)) at 15º (for filling ratio 50% and heat supplied 200W). that’s because inclination lead the complex spatial flow to be a uniform circulation flow, hence it’s lead to non-homogeneity in evaporation and condensation processes and finally result in reduction of thermal performance.

الأنابيب الحرارية واحدة من الحلول الحديثة لتحرير الطاقة الحرارية من المصادر ذات درجات الحرارة العالية أو للحصول على توزيع منتظم للحرارة في المستودعات السائلة أو الصلبة. ان التداخل بين الطورين السائل والغازي في داخله قد تم فرضه بطريقة تقليدية من قبل الباحثين ولم يتم الكشف عنه بدقة. في هذه الدراسة تم اجراء تقريباً 480 حل رياضي وفحص تجريبي مختبري لتأكيد المشاهدات التي نشرناها سابقاً حول انماط الجريان الفضائية غير المنتظمة لكل من الطورين داخل انبوب حراري مصنوع من النحاس وبدون فتيلة يعتمد على التدوير الحراري ومملوء جزئيا بالماء. تم الحصول على النتائج الرياضية من موديل رياضي حسابي ديناميكي انتقالي بالابعاد الثلاثية تم تضمينه مختلف المتغيرات لتقريبه للحالة الواقعية على الرغم من التعقيد في طرق الحسابات وزيادة المدة اللازمة لاكمال التشغيل للمحاكاة الرياضية. ان نسبة التوافق العالية بين نتائج الموديل الرياضي والفحص المختبري لطريقة وقيم التوزيع الحراري تؤكد صحة نتائج الموديل الرياضي. ان المخططات الكنتورية المستحصلة من الموديل الرياضي والخاصة بنمط جريان وتوزيع الطورين داخل الأنبوب الحراري، تبين ان الطورين يجريان بنمط فضائي غير منتظم وغير مستقر وغير مستمر على شكل واحد. كلا الطورين يعانيان من انتقال للحرارة وتغير بالطور مع بعضهما خلال الجريان للاعلى (البخار) او الجريان للاسفل(السائل المتكثف). ازداد الاداء الحراري بنسبة (+10%) نتيجة الميلان من الوضع العمودي الى زاوية º60، ومن ثم انخفض الاداء الحراري بنسبة (-15%) بزاوية º15 (هذه القيم عند نسبة ملئ 50% وطاقة حرارية مسلطة 200 واط). هذا بسبب كون ميلان الانبوب الحراري يؤدي الى تنظيم نمط الجريان الفضائي وتقريبه الى الدوران المنتظم، كما أنه يؤدي الى عدم تجانس عمليتي التبخر والتكثف وبالتالي يؤدي الى انخفاض الاداء الحراري ككل.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (4)


Year
From To Submit

2019 (1)

2017 (1)

2016 (2)