research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Trans-oral penetrating pin
اصابه النخاع الشوكي العنقي بواسطه دبوس مخترق خلال الفم

Author: Emad S. Abbas عماد صادق عباس
Journal: Journal of the Faculty of Medicine مجلة كلية الطب ISSN: 00419419 Year: 2012 Volume: 54 Issue: 3 Pages: 163-165
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Aim: is to report a case of trans-oral pin, penetrating base of skull and upper cervical region, which is rarely reported in the literatures and to compare it with other studies reporting similar case.Patients Methods: the details, the presentation, both clinical and radiological finding, and surgical approach of such a case are presented.Results: the diagnosis was verified with plain x-rays and C.T. scan with bone study. Surgery was conducted under G.A., the patient was recovered well without neurological deficit.Conclusion: meticulous and close pre-operative care with safe operator and careful fellow up is mandatory. Surgery only offers the best chance of care.Keywords: cervical injury, craniocervical trauma, pin trauma, trans-oral trauma.

الهدف: هو تسجيل حالة دبوس اخترق الفم، اختراق قاعدة الجمجمة والمنطقة العنقية العليا، والتي نادرا ما تذكر في البحوث الطبيه، ومقارنتها مع الدراسات الأخرى التي تقدم تقارير مماثلة.ويسرد الباحث تفاصيل الحاله السريريه و الشعاعية, و نهج العمليات الجراحية في مثل هذه الحاله.تم التأكد من التشخيص بالأشعة السينية والتصوير المقطعي العادي مع دراسة العظم. و تم اجراء الجراحة تحت التخدير العام، تعافى المريض بشكل جيد من دون عجز عصبي, و اخرج بحاله متحسنه.الاستنتاج:ينتهي الباحث الى القول بأن التشخيص الدقيق والتحضير الجيد للعملية مع وجود فريق طبي امن اضافة الى رعاية ومتابعة المريض سلوك الزامي للخروج بنتائج جيدة ,التداخل الجراحي هو الفرصة الوحيدة للعلاجمفاتيح الكلمات: اصابة النخاع الشوكي العنقي اصابة منطقة اتصال الدماغ بالنخاع الشوكي اختراق دبوس اصابة خلال الفم للنخاع الشوكي


Article
Behavior of Reinforced Hybrid Concrete Corbel-Column Connection with Vertical Construction Joint

Authors: Ammar Yasir Ali --- Waseem Hamzah Mahdi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 1 Pages: 30-44
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper, shear behavior of reinforced hybrid concrete connection of corbel-column is experimentally investigated. Nine homogenous and hybrid concrete corbel-column connections subjected to vertical applied loads were constructed and tested within two test groups (A, B). The experimental program included the effect of several variables such as type of hybrid concrete;high strength concrete (HSC) or steel fiber reinforced concrete (SFRC), monolithic casting of hybrid concrete connection, and presence of construction joint at the interface of corbel-column. Experimental results showed significant effects of concrete hybridization on the structural behavior of connection specimens such as: ultimate strength, cracking loads, cracking patterns, and failure modes. Hybridization process in group (A) included hybrid connection of corbel-column with HSC or SFRC corbel instated of NSC. This process led to increase the capacity of connection by (26%, 38%) and shear cracking loads by (20%, 120%) respectively. Moreover, connections of hybrid concrete corbels cast monolithically improved the shear capacity of corbels by (19%, 42%) for HSC or SFRC respectively. In group (B), presence of construction joint at connection region reduced the shear capacity of connectionsby (10% to 22%) and cracking loads by (23%-62%) compared with connections cast monolithically.

تقدم هذه الدراسة تقصيا عمليا لسلوكمنطقة الاتصال بين العمود والكتف والمكونة من الخرسانة الهجينة. تضمنت الدراسة انشاء وفحص تسعة من نماذج الكتف الخرساني المرتبط بعمود الهجينة والمتجانسة تحت تأثير احمال عمودية ضمن مجموعتينA,B)).تضمن البرنامج العملي تأثير عدة متغيرات مثل نوع الخرسانة الهجينة;خرسانة عالية المقاومةHSC)) او الخرسانة الحاوية على الالياف الفولاذية (SFRC),الصب الموحد لمنطقة الاتصال الهجينة ,وجود مفصل انشائي في منطقة التداخل بين العمود والكتف. بينت نتائج الدراسة العملية وجود تأثيرات مهمة لتهجين الخرسانة على التصرف الانشائي لنماذج الاتصال من حيث: المقاومة القصوى ,احمال التشقق, نمط التشقق, شكل الفشل. عملية التهجين في المجموعةA)) تضمنت انشاء منطقة اتصال هجينة بين الكتف والعمود عن طريق صب الكتف بخرسانة عالية المقاومة او حاوية على الياف فولاذية بدلا من الخرسانة ذات التحمل الاعتياديNSC)).تؤدي هذه العمليةالى زيادة مقاومة منطقة الاتصال بحوالي26%, 38%)) واحمال تشققات القص بحوالي 20%, 120%)) على التوالي.اضافة الى ذلك , تزداد مقاومة القص في مناطق الاتصال ذات الاكتاف الخرسانية الهجينة التي تم صبها في وقت واحد بحوالي 19%-42%)) للأكتاف المهجنة بالخرسانة عالية المقاومة او الخرسانة الحاوية على الالياف الفولاذية على التوالي. في المجموعة B)),وجود مفصل انشائي في منطقة الاتصال يقلل من مقاومتها للقص بحوالي(10%-41%) واحمال التشقق بحوالي((23%- 62% مقارنة بمناطق الاتصال التي تم صبها في وقت واحد.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2017 (1)

2012 (1)